• Title/Summary/Keyword: Humidifier modeling

Search Result 11, Processing Time 0.027 seconds

Nonlinear variation of performance for a NAFION membrane humidifier with inlet temperature elevation (입구 온도에 따른 나피온 막 가습기 성능의 비선형적 변화)

  • Hwang, J.Y.;Kang, K.;Kang, H.S.;Kim, J.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.78.2-78.2
    • /
    • 2010
  • Effect of temperature elevation of inlet air on performance of a membrane humidifier for PEMFC vehicle application was investigated both experimentally and numerically. A shell-and-tube typed gas-to-gas humidifier with Nafion membrane was tested. The experimental result showed that water transfer varies nonlinearly with the temperature elevation. Numerical analysis based on detailed modeling is also conducted on a single tube geometry to explain this nonlinear behavior. The simulation revealed that the local water flux varies nolineary and dramatically along the tube. Analysis is based on competing role of temperature increase and relative humidity decrease, both of which seriously affect water conductivity of the membrane.

  • PDF

Soft Sensor Development for Predicting the Relative Humidity of a Membrane Humidifier for PEM Fuel Cells (고분자 전해질 연료전지용 막가습기의 상대습도 추정을 위한 소프트센서 개발)

  • Han, In Su;Shin, Hyun Khil
    • Journal of Hydrogen and New Energy
    • /
    • v.25 no.5
    • /
    • pp.491-499
    • /
    • 2014
  • It is important to accurately measure and control the relative humidity of humidified gas entering a PEM (polymer electrolyte membrane) fuel cell stack because the level of humidification strongly affects the performance and durability of the stack. Humidity measurement devices can be used to directly measure the relative humidity, but they cost much to be equipped and occupy spaces in a fuel cell system. We present soft sensors for predicting the relative humidity without actual humidity measuring devices. By combining FIR (finite impulse response) model with PLS (partial least square) and SVM (support vector machine) regression models, DPLS (dynamic PLS) and DSVM (dynamic SVM) soft sensors were developed to correctly estimate the relative humidity of humidified gases exiting a planar-type membrane humidifier. The DSVM soft sensor showed a better prediction performance than the DPLS one because it is able to capture nonlinear correlations between the relative humidity and the input data of the soft sensors. Without actual humidity sensors, the soft sensors presented in this work can be used to monitor and control the humidity in operation of PEM fuel cell systems.

A STUDY ON DEVELOPING A DESIGN OF SUPERSONIC HUMIDIFIER FOR HOME USE. - With a focus on 3 domestic companys Household electric appliances - (가정용 초음파 가습기 디자인개발에 관한 연구 - 국내가전 3사를 중심으로 -)

  • 오성진
    • Archives of design research
    • /
    • v.6 no.1
    • /
    • pp.23-46
    • /
    • 1993
  • The development of technology in modern industrial world which grows and changes every day is shortening the cycle of life span of products, so there is a flood of products around us. It is enough to say that this phenomenon leads to further emphasis on the aspect of design for human being. It is not a new fact that to design for the rational function and the modeling from to make a combination and to satisfy consumers' desire is a short cut to gain competitive superiority in developing new products for MIS security. Therefore the design which plays a leading role in the activity of creating more convenient, more aesthetic, and more econemical products is called 'NEW CORPORATE WEAPON'. The amount of effort made for developing products is different in each company, but recently the plan to develope new products and its process arouse more interest. This thesis purports to improve objective understanding about the development of design by investigating products development research and the process of analysis and designing as a case study on developing a domestic supersonic humidifier. This thesis consists of five chapters in all. In chapter one as a preface, the purpose the method and the scope of the study is described. Chapter two contains my effort to grasp the background of study on the design and the basic structure of supersonic humidifier. Chapter three is an examination into the present conditions of supersonic humidifier used in domestic and foreign area, and the shape of design. In chapter four, a guide for the development of design is established. The idea sketch based on a fundamental shape and the drawing are added to this. In chapter five on the basis of the result of analysis in the preceding research I describe the development of design of products on the premise that marketing gives proof for them but the products oriented by manufacturer are not included in this case. In this thesis, I try to recognize the process of the develpment of design and the importance of the plan for design in developing products by examining an investigative and analytic study on the design of products.

  • PDF

A Study on the Interrelationship among Service Quality, Customer Satisfaction and Customer Loyalty by Distribution Channel, in the Dehumidifier Goods Industry (제습기산업의 유통경로별 서비스품질이 고객만족 및 고객충성에 미치는 상호관계에 대한 연구)

  • Kim, Kyusik;Ree, Sangbok
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.4
    • /
    • pp.665-684
    • /
    • 2014
  • Purpose: The purpose of this study was to test and verify on the interrelationship among Service Quality, and Customer Satisfaction and Customer Loyalty in the Humidifier Goods industry. Especially, we study on the relative importance of each CS variables by distribution channel. Nowadays, most of manufacturing companies are proceeding the product servitization, which is combined service contents with product characteristics in the field of manufacturing industries. Methods: We surveyed humidifier purchaser about the some of CS variables and analyzed it using SPSS 21.0 and AMOS 21.0 as a statistical analysis tool. We use the frequency analysis, confirmatory factor analysis, multi-regression analysis and structural equation modeling analysis for our empirical study. Results: As the result of study, we find that Service Quality(SQ) influence Customer Satisfaction(CS) and CS influence Customer Loyalty(CL). Also, we verify that CS works mediate interaction on the effects between SQ and CL. And there are the significant relative effect of SQ to Customer Satisfaction in some of distribution channel. Conclusion: Finally, we make certain that the market size of the Humidifier goods industry will be increased rapidly. And the distribution channe l is more important to medium and small-sized enterprise. So, we have to pay attention to the study on the distribution channel of the Humidifier goods industry. And then, we expect more researches and studies on Service Quality and Customer Satisfaction in the field of manufacturing industries.

Study on Effect of Increase in Inlet Temperature on Nafion Membrane Humidifier (입구온도 변화가 중공사형 나피온 막가습기의 성능에 미치는 영향에 대한 연구)

  • Hwang, Jun-Young;Chang, Hyo-Sun;Kang, Kyung-Tae;Kang, Heui-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.361-369
    • /
    • 2011
  • The effect of an increase in the temperature of inlet air on the performance of a membrane humidifier for a PEMFC (Polymer Electrolyte Membrane Fuel Cell) vehicle was investigated both experimentally and numerically. A shell-and-tube type gas-to-gas humidifier with Nafion membrane was tested. The experimental result showed that water transfer varies nonlinearly with the temperature elevation. Numerical analysis based on detailed modeling was also conducted in simplified geometry of a single tube to explain this nonlinear behavior. The simulation revealed that the local water flux varies nonlinearly and dramatically along the tube. The analysis was based on the inverse relationship between the increase in temperature and decrease in relative humidity, both of which seriously affect the water conductivity of the membrane.

Modeling of Water Transport in Porous Membrane for PEMFC Humidifer (PEMFC 가습기 용 다공성 중공사막의 물전달 모델링)

  • Hwang, Jun Y.;Park, J.Y.;Kang, K.;Kim, J.H.;Kim, K.J.;Lee, M.S.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.96.2-96.2
    • /
    • 2011
  • Water transport through the microporous membrane was modeled considering capillary condensation as well as capillary flow in porous media as a function of pore diameter and relative humidity at the surface. The present model was adopted by the numerical simulation of non-isothermal, non-homogenous flow in a shell and tube typed gas to gas membrane humidifier for PEMFC (proton exchange membrane fuel cell) and the result shows good agreement with experimental data.

  • PDF

Treatment of Malodorous Waste Air by a Biofilter Process Equipped with a Humidifier Composed of Fluidized Aerobic and Anoxic Reactor (폐가스 가습조(유동상호기 및 무산소조)를 포함한 바이오필터공정을 이용한 악취폐가스의 처리)

  • Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.85-95
    • /
    • 2018
  • In this research, a biofilter system equipped with a biofilter process and a humidifier composed of a fluidized aerobic and an anoxic reactor, was constructed to treat odorous waste air containing hydrogen sulfide, ammonia and VOC, frequently generated from pig and poultry housing facilities, compost manufacturing factories and publicly owned facilities. Its optimum operating condition was revealed and discussed. In the experiment of complex feed, the ammonia of fed-waste air was removed by ca. 75% and more than 20% at the stage of the humidifier and the biofilter, respectively. The toluene of the fed-waste air was removed by ca. 20% and more than 70% at the stage of the humidifier and the biofilter, respectively. Therefore the water-soluble ammonia and the water-insoluble toluene were treated mainly at the stage of the humidifier and the biofilter, respectively. In addition, hydrogen sulfide was almost absorbed at the stage of the humidifier so that it was not detected at the biofilter process. In the experiment of ammonia-containing feed, the ammonia of fed-waste air was removed by ca. 65% and 35% at the stage of the humidifier and the biofilter, respectively. Its removal efficiency of ammonia at the stage of the humidifier was 10% less than that in the experiment of complex feed, due to no supply of such carbon source as toluene required in the process of denitrification. In the experiments of complex feed, ammonia-containing feed with and without (instead, glucose) the addition of yeast extract, the absorption rates of ammonia-nitrogen were ca. 0.28 mg/min, 0.23 mg/min and 0.27 mg/min, respectively. The corresponding denitrification rates in the anoxic reactor were 0.42 mg/min, 0.55 mg/min and 0.27 mg/min, respectively. In addition, in the modeling of bubble column(the fluidized aerobic reactor of the humidifier) process, the value of specific surface area(a) of bubbles multiplied by enhanced mass transfer coefficient (E $K_y$) was evaluated to be 0.12/hr.

Humidification Characteristics & Modeling of The Membrane Humidifier for Operation of PEMFCs (고분자전해질 연료전직 운전용 막가습기의 가습특성 및 해석)

  • 박세규;신석재;하흥용;오인환;홍성안;이태희
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.115-119
    • /
    • 2002
  • 고분자 전해질 연료전지는 전해질로 고체고분자막을 사용하는 연료전지로 고분자막은 수소 이온의 활발한 전달을 위해 일정량의 수분이 존재해야 한다. 따라서 연료전지의 운전 중에 고분자막은 항상 수화되어 있어야 하며 수분이 부족하게 되면 수소이온 전도도가 떨어지고, 막의 수축으로 인해 전극과 막 계면의 저항이 증가한다. 반대로 수분이 많이 존재하면 촉매 표면에 반응기체의 확산이 어려워져 전지 성능이 감소하게 된다.(중략)

  • PDF

Dyamic Modeling and Analysis of Air Supply System for Vehicular PEM Fuel Cell (고분자 전해질형 연료전지 자동차의 급기 시스템의 동적 모델링 및 분석)

  • Jang, HyunTak
    • Journal of Hydrogen and New Energy
    • /
    • v.15 no.3
    • /
    • pp.175-186
    • /
    • 2004
  • In this paper, we developed the dynamic model of a fuel cell system suitable for controller design and system operation. The transient phenomena captured in the model include the flow characteristics and inertia dynamics of the compressor, the intake manifold filling dynamics, oxygen partial pressures and membrane humidity on the fuel cell voltage. In the simulations, we paid attention to the transient behavior of stack voltage and compressor pressure, stoichiometric ratio. Simulation results are presented to demonstrate the model capability. For load current following, stack voltage dynamic characteristics are plotted to understand the Electro-chemistry involved with the fuel cell system. Compressor pressure and stoichiometric ratio are strongly coupled, and independent parameters may interfere with each other, dynamic response, undershoot and overshoot.

Analysis of Part Load Performance of a Hybrid PEMFC System (하이브리드형 고분자전해질 연료전지 시스템의 부분부하 성능해석)

  • Ji, Seung-Won;You, Byung-June;Kim, Tong-Seop;Sohn, Jeong-Lak;Lee, Young-Duk;Ahn, Kook-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.11
    • /
    • pp.849-855
    • /
    • 2008
  • The paper addresses modeling and analysis of the part load performance of a hybrid fuel cell system integrating a polymer electrolyte membrane fuel cell(PEMFC) and a gas turbine(GT). The system is a pressurized one where the working pressure of the PEMFC is higher than the ambient pressure. In addition to the two major components, the system also includes auxiliary parts such as a steam reformer, a humidifier, and afterburner and so on. Based on design analysis, component off-design models are incorporated in the analysis program and part load operation is simulated. The mode for the part load operation of the PEMFC/GT hybrid system is a variable rotational speed operation. The operating characteristics and variations in the system efficiency and component performance parameters at part load are analyzed.