• Title/Summary/Keyword: Humidification Efficiency

Search Result 28, Processing Time 0.027 seconds

Performance Analysis of Water Direct Contact Air Conditioning System (물 직접접촉식 공기조화장치의 성능해석)

  • Yoo, S.Y.;Kwon, H.K.;Song, J.;Kim, K.Y.;Park, J.T.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.158-163
    • /
    • 2001
  • Performance of the water direct contact air conditioning system, in which heat and mass are transferred directly between air and water droplet, is simulated by semi-empirical method. This system improves transport efficiency compared to conventional indirect contact system and cooling, heating, dehumidification and humidification are attained with one unit. In this study, temperature and flowrate for air and water are measured in the various cooling and heating conditions, and correlations for $h_{c}A/c_{pm}$ are derived from these data. Cooling and heating characteristics of the water direct contact air conditioning system are investigated using correlations.

  • PDF

A Performance Analysis and Experiments on Plastic Film/Paper Humidifying Elements Consisting of Horizontal Air Channels and Vertical Water Channels (수평 공기 채널과 수직 물 채널로 구성된 플라스틱 필름/종이 가습 소자의 성능)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.1
    • /
    • pp.55-63
    • /
    • 2016
  • New materials and shapes for a humidifying element were developed which outperformed the widely used crisscross glass wool Glasdek media design. The new material consists of 50% cellulose and 50% PET. The parallel channel configuration was devised to reduce excessive pressure loss caused by the reduced height (from 7.0 mm to 5.0 mm) of the crisscross configuration. For the same crisscross configuration, the humidification efficiency of the cellulose/PET element was 26% higher than that of the glass wool element. For the same cellulose/PET material, humidification efficiency of the parallel channel configuration was 14% higher than that of the crisscross configuration. As for the pressure drops, the cellulose/PET element was 2-52% higher than those of the glass wool element. For the same cellulose/PET material, the pressure drop of the parallel channel configuration was 14% higher than that of the crisscross configuration. Data were compared against the predictions from existing correlations and those by the proposed model.

A study on Removal Method of Humidifier Particles Using Electrostatic Precipitation Technology

  • Inpyo Cha;Taekeon Jung;Hyunjun Yun;Chuljun Choi
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.239-245
    • /
    • 2023
  • In this research, our objective was to investigate the efficacy of electrostatic precipitation in capturing mist particles. We assumed that it could be helpful in multi-functional facilities and similar environments where both humidification and dehumidification are required. We derived the air density of the humidified air based on its properties using Dalton's law. The analysis was performed to evaluate the collection efficiency of capturing mist aerosols of various sizes. As a result, we revealed that under the conditions of a dry-bulb temperature of 26.0℃ and relative humidity of 8%, the system achieved a collection efficiency of 99.999% or more for aerosols larger than 2.5㎛. These results indicate that electrostatic precipitation technology shows great promise as an effective method for capturing mist particles.

A Study of Humidification Method in PEMFC (고분자전해질형 연료전지의 가습 방법에 대한 연구)

  • Hyun, Deok-Su;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.3
    • /
    • pp.212-216
    • /
    • 2003
  • The humidification measurement system designed in laboratory was used to measure relative humidity and temperature of reaction gases passing through internal or external humidifier which was used in proton exchange membrane fuel cell test station. The relative humidity of gases was stabilized after $10\~20$ minutes and thus credibility of data could be assured. The effect of relative humidity on fuel cell performance could be analyzed by humidity measurement system. Extreme caution was needed to avoid humidity sensor mal-function or failure which is probable in experiment of high humidity condition near $100\%$. The amount of water carried by gas through humidifier was increased along the flow rate of gas. However, the extent of increase was lowered at high gas flow rate. These phenomena could be analyzed as residence time effect of gas in humidifier.

Comparison of Spectroscopic Characteristics and Chemical Oxygen Demand Efficiencies for Dissolved Organic Matters from Diverse Sources (기원별 용존 유기물의 분광특성 및 COD 산화율 비교)

  • Jung, Ka-Young;Park, Min-Hye;Hur, Jin;Lee, Seungyoon;Shin, Jae-Ki
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.589-596
    • /
    • 2009
  • The spectroscopic characteristics and chemical oxygen demand (COD) oxidation efficiencies were investigated for dissolved organic matters (DOM) from diverse sources, which may indirectly affect the concentrations and the quality of DOM found in watersheds. The DOM investigated for this study showed a wide range of the percent distributions of refractory organic matter (R-OM) from 8 to 100%. Relatively high R-OM distributions were observed for the DOM with the source of head water, sediments, paddy soils, field soils, and treated sewage whereas the DOM from livestock waste, reed, weeds, algae, and attached algae exhibited lower R-OM percent distributions. The percent distribution of R-OM had positive correlations with specific UV absorbance (SUVA) and humidification indices (HIX) of DOM. The investigated DOM was classified into four different source groups (i.e., biota, vegetables, soils, sediments) by comparing the synchronous fluorescence spectra. The DOM group from biota source was characterized by a prominent presence of protein-like fluorescence (PLF) whereas fulvic-like fluorescence (FLF) was additionally observed for vegetable-source DOM. FLF became significant for the DOM from both soils and sediments although no PLF was found for soil-derived DOM. A range of COD oxidation efficiency was observed for the various DOM, ranging from 36 to 94% and from 65 to 125% for $COD_{Mn}$ and $COD_{Cr}$, respectively. The results indicate that $COD_{Cr}$ reflects the higher OM concentration than $COD_{Mn}$. However, 95% confidence intervals of the COD oxidation efficiencies were similar for the two types of COD, suggesting that $COD_{Cr}$ may not be the superior OM index to $COD_{Mn}$ in terms of the variability of the oxidation efficiency. No significant correlations were obtained between COD oxidation efficiencies and the spectroscopic characteristics of DOM for this study.

Development of Membrane Humidifier for Fuel Cell Bus (200kW) (연료전지 버스용 (200kW급) 막가습기 개발)

  • Lee, Moo-Seok;Kang, Chung-Seok;Yoon, Young-Seo;Kim, Kyoung-Ju;Yun, Joon-Khee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.471-473
    • /
    • 2006
  • An object of the present study is to provide a hollow fiber membrane humidifier capable of improving the humidification efficiency while lowering the pressure loss, and is suitably usable for PEMFC(Polymer Electrolyte Membrane Fuel Cell). The performance of PEMFC is decisively dependent on the humidity of the electrolyte membrane(fluorinated membrane) and a humidifier plays an important role in moisturizing electrolyte membrane. Especially this humidifier is adaptable for lower price to promote the commercialization of fuel cell vehicles and is passive type to be power free and to be volumetrically optimized. In this research, we propose the substitutes for the expensive fluorinated materials and the optimum dry-jet wet spinning conditions of hollow fiber membrane to get the fuel cell humidifier. In addition to that we established the standard method of evaluating the moisturizing performance of the humidifier of various materials.

  • PDF

Experimental study of the effect of the glass fibers on reducing collapse of a collapsible soil

  • Bakir, Nassima;Abbeche, Khelifa;Panczer, Gerard
    • Geomechanics and Engineering
    • /
    • v.12 no.1
    • /
    • pp.71-83
    • /
    • 2017
  • Collapsible soil presents a porous unsaturated structure, its sudden settlement after humidification, without supplementary charge, can be of a big nuisance for the foundations and therefore for the constructions built on it. To improve its structure and limit its instability, samples of laboratory reconstituted soil, with different percentages of water contents and compacted at different compaction energies, were treated with glass-fiber. The study of the mechanical behavior was performed by oedometer tests. The microstructure was explored by the Scanning Electron Microscope (SEM). The results obtained show clearly the efficiency of the treatment with glass fiber on reducing the collapsibility of such soil.

Development of Membrane Humidifier for FCEV (연료전지 자동차용 막 가습기 개발)

  • Kim, Kyoung-Ju;Lee, Moo-Seok;Yun, Joon-Khee;Shin, Yong-Cheol
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.177-179
    • /
    • 2007
  • An object of the present study is to provide a hollow fiber membrane humidifier capable of improving the humidification efficiency while lowering the pressure loss, and is suitably usable for PEMFC(Polymer Electrolyte Membrane Fuel Cell). The performance of PEMFC is decisively dependent on the humidity of the electrolyte membrane(fluorinated membrane) and a humidifier plays an important role in moisturizing electrolyte membrane. Especially, this humidifier is a passive type(power-free) item and is volumetrically optimized. In this research, we propose the substitutes for the expensive fluorinated humidifier materials and the optimum dry-jet wet spinning conditions of hollow fiber membrane. In addition to that, This study will present an performance of an humidifier and compare computational results with the experimental data.

  • PDF

Performance Test of Proton Exchange Membrane Fuel Cell with the Variation of Operation Condition (이온교환막 연료전지용 막 가습기의 운전 조건에 따른 성능 실험)

  • Bae, Ho-June;Kim, Yong-Mo;Lee, Young-Duk;Yu, Sang-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.6-9
    • /
    • 2008
  • The efficiency and life time of the proton exchange membrane (PEM) fuel cell system is critically changed with its humidity which should be maintained properly during dynamic operation. Membrane humidifier is required to regulate proper humidity level for the design point of the PEMFC system. In this study, we presented the performance of the cylindrical membrane humidifier which is operated as water-to-gas. Dry air pressure, liquid water flow temperature, and air flow rate were chosen as the operating parameters. Humidity level is expressed with dew point.

  • PDF

Performance Analysis of Water/Air Direct Contact Air Conditioning System (물-공기 직접접촉식 공기조화장치의 성능해석)

  • 유성연;권화길;김광영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.175-183
    • /
    • 2004
  • Performance of the water/air direct contact air conditioning system, in which heat and mass are directly transferred between air and water droplet, is simulated using semi-empirical method. Direct contact system improves transport efficiency compared to conventional indirect contact system. In this study, correlations for h$_{c}$A / c$_{pm}$ which represent the capacity of direct contact system are derived as a function of air and water flowrate from the experimental data. Cooling and heating performance of the water/air direct contact air conditioning system are evaluated using these correlations.ons.