• Title/Summary/Keyword: Humerus Bone

Search Result 138, Processing Time 0.019 seconds

Chondroblastoma of the Talus Mimicking an Aneurysmal Bone Cyst: A Case Report (동맥류성 골낭종으로 오인된 거골에 발생한 연골모세포종: 증례 보고)

  • Park, Ji Soo;Suh, Jin Soo;Choi, Jun Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.1
    • /
    • pp.31-34
    • /
    • 2019
  • Chondroblastoma is a rare benign tumor that produces giant cells and cartilage matrix. The tumor occurs in people between 10 and 25 years with slightly higher incidence in males. The condition occurs in the proximal epiphysis of the tibia and humerus, distal epiphysis of the femur, but its occurrence in the talus is relatively rare, accounting for 4% of the total number of chondroblastoma cases. Chondroblastoma is often misdiagnosed as a primary aneurysmal bone cyst, giant cell tumor, chondromyxoid, and lesion of a secondary aneurysmal bone cyst by fibrous dysplasia. The most commonly used surgical method for chondroblastoma is broad curettage with bone grafting. In general, an aneurysmal bone cyst is associated with a second degree chondroblastoma, which is approximately 20%. Chondroblastoma of the talus and secondary aneurysmal bone cysts can be misdiagnosed as primary aneurysmal bone cysts. This paper reports a case of a young male patient with chondroblastoma of the talus, which was initially misdiagnosed as an aneurysmal bone cyst with involvement of the talo-navicular joint.

Osteogenic Sarcoma with Osseous, Pulmonary, and Pericardial Metastases Simultaneously Demonstrated on Bone Scintigraphy at Initial Presentation (초기 골스캔에서 뼈, 폐와 심낭으로의 전이를 보인 골육종)

  • Lim, Seok-Tae;Kim, Min-Woo;Sohn, Myung-Hee;Hwang, Pyoung-Han
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.5
    • /
    • pp.336-339
    • /
    • 2003
  • Purpose: A 6-year-old boy with osteogenic sarcoma of the left humerus underwent bone scintigraphy. Tc-99m MDP was accumulated not only in the primary tumor but also in the osseous and extraosseous (pulmonary and pericardial) metastases. Osteogenic sarcoma directly produces osteoid, both in the primary and metastatic lesions. Tc-99m MDP is avidly taken up by tumor osteoid. At initial presentation, only 2% of cases have both pulmonary and osseous metastases. The patient had osseous, pulmonary, and pericardial metastases at presentation. This case presents that increased uptakes of Tc-99m MDP by the primary and metastatic tumor were demonstrated on bone scintigraphy at presentation.

Hemiarthroplasty in Comminuted Fracture and Dislocation of the Proximal Humerus (상완골 근위부 분쇄성 골절 및 탈구에서 시행한 견관절 반치환술)

  • Hwang Sung-Kwan;Kim Yong-Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.205-211
    • /
    • 1998
  • The comminuted fracture and dislocation of the proximal humerus occur more frequently in older patient group and operative treatment is difficult due to poor bone quality. Based on Neer's work, hemiarthroplasty has now become widly accepted for the management of the three-part fracture and four-part fracture-dislocation of the proximal humerus in old age group. The purpose of this study is to evaluate function, pain relief, and patient satisfaction after hemiarthroplasty for proximal humerus fractures and dislocations. Authors reviewed and analyzed 14 prosthetic replacement in comminuted proximal humeral fracture and dislocation at the Department of Orthopaedic Surgery, Yonsei University Wonju College of Medicine from March, 1988 to May, 1997. The results were as follows the average age was 58.9years and the ratio of males and females was 5:9. The most common cause of injury was traffic accident(43%). According to the classification of Neer, three part fracture were three(21%), four-part fracture and four-part fracture-dislocation were eleven(79%). The prosthetic replacement was performed within two weeks in eight patient and six were performed after two weeks. The results were analysed according to Neer's criteria and five cases showed satisfactory results. We concluded that hemiarthroplasty for fracture and dislocation of the proximal humerus facilitated the restoration of humerus length and pain relief, thereby allowing earlier motion to prevent the development of painful shoulder: stiffness.

  • PDF

Elbow Arthrodesis with bone Autograft for the Management of Gunshot Fracture in a Dog (총상 골절 개에서 자가골 이식과 주관절 고정술)

  • Lee Jong Il;Alam Md. Rafiqul;Kim Nam soo
    • Journal of Veterinary Clinics
    • /
    • v.22 no.1
    • /
    • pp.60-64
    • /
    • 2005
  • A 6year-old intact male hound cross dog, weighing 23 kg, was presented to the Teaching Animal Hospital, Chonbuk National University with the history of gunshot wound at the left elbow joint. Survey radiographs of the affected elbow revealed the presence of a metallic bullet caudal to the olecranon processes and comminuted fracture of the proximal radius and ulna. The first treatment strategy included removal of the bullet and fixation of the radius and ulna using separate bone plates, bone screw, K-wire and surgical wire, was failed. The second treatment strategy included olecranon osteotomy and rigid immobilization of the elbow joint with a bone plate applied to the caudal aspect of the humerus and ulna along with autogenous bone grafts collected from the 13th rib. The optimal angle of the joint following arthrodesis of this case appeared to be 130°. This resulted in improving the case but after 60 weeks the plate was bent and there was exudation from the wound. The third treatment strategy was the same with the second except for that the bone autografts were collected from the proximal metaphyses of the ipsilateral humerus. This resulted in a successful arthrodesis 6 weeks after the surgery. Elbow arthrodesis with bone autograft resulted in acceptable function, but abnormal gait remained in the dog due to mechanical interference with the movement of the joint.

Internal Fixation with a Locking T-Plate for Proximal Humeral Fractures in Patients Aged 65 Years and Older

  • Yum, Jae-Kwang;Seong, Min-Kyu;Hong, Chi-Woon
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.217-221
    • /
    • 2017
  • Background: The purpose of this study was to evaluate the clinical and radiographic outcomes of internal fixation with locking T-plates for osteoporotic fractures of the proximal humerus in patients aged 65 years and older. Methods: From January 2007 through to December 2015, we recruited 47 patients aged 65 years and older with osteoporotic fractures of the proximal humerus. All fractures had been treated using open reduction and internal fixation with a locking T-plate. We classified the fractures in accordance to the Neer classification system; At the final follow-up, the indicators of clinical outcome-the range of motion of the shoulder (flexion, internal rotation, and external rotation) and the presence of postoperative complications-and the indicators of radiographic outcome-the time-to-union and the neck-shaft angle of the proximal humerus-were evaluated. The Paavolainen method was used to grade the level of radiological outcome in the patients. Results: The mean flexion was $155.0^{\circ}$ (range, $90^{\circ}-180^{\circ}$), the mean internal rotation was T8 (range, T6-L2), and the mean external rotation was $66.8^{\circ}$ (range, $30^{\circ}-80^{\circ}$). Postoperative complications, such as plate impingement, screw loosening, and varus malunion were observed in five patient. We found that all patients achieved bone union, and the mean time-to-union was 13.5 weeks of the treatment. The mean neck-shaft angle was $131.4^{\circ}$ at the 6-month follow-up. According to the Paavolainen method, "good" and "fair" radiographic results each accounted for 38 and 9 of the total patients, respectively. Conclusions: We concluded that locking T-plate fixation leads to satisfactory clinical and radiological outcomes in elderly patients with proximal humeral fractures by providing a larger surface area of contact with the fracture and a more rigid fixation.

Hook Plate Fixation for Isolated Greater Tuberosity Fractures of the Humerus

  • Lee, Kyoung-Rak;Bae, Ki-Cheor;Yon, Chang-Jin;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.222-229
    • /
    • 2017
  • Background: The purpose of this study was to investigate the outcomes after fixation using a 3.5-mm locking compression plate (LCP) hook plate for isolated greater tuberosity (GT) fractures of the proximal humerus. Methods: We evaluated the postoperative radiological and clinical outcomes in nine patients who were followed up at least 1 year with isolated GT fractures. Using the deltopectoral approach, we fixed the displaced GT fragments with a 3.5-mm LCP hook plate (Synthes, West Chester, PA, USA). Depending on the fracture patterns, the hook plate was fixed with or without augmentation using either tension suture or suture anchor fixation. Results: All the patient showed successful bone union. The mean time-to-union was 11 weeks. The radiological and clinical outcomes at the final follow-up were generally satisfactory. The mean visual analogue scale for pain, the University of California at Los Angeles score, the American Shoulder and Elbow Surgeons score, and the subjective shoulder value were 1.4, 30.3, 84.3, and 82.2%, respectively. The mean active forward flexion, abduction, external rotation, and internal rotation of the shoulder were $156.7^{\circ}$, $152.2^{\circ}$, $61.1^{\circ}$, and the 10th thoracic vertebral level, respectively. Only one patient presented with a postoperative complication of shoulder stiffness. The patient was treated through arthroscopic capsular release on the 5th postoperative month. Conclusions: We conclude that fixation using 3.5-mm LCP hook plates for isolated GT fractures of the proximal humerus is a useful treatment method that provides satisfactory clinical and radiological outcomes.

Anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study

  • Lim, Joon-Ryul;Yoon, Tae-Hwan;Lee, Hwan-Mo;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.66-71
    • /
    • 2021
  • Background: Extra-articular distal humerus locking plates (EADHPs) are precontoured anatomical plates widely used to repair distal humeral extra-articular diaphyseal fractures. However, EADHPs frequently cause distal protrusion and resulting skin discomfort. The purpose of this study was to predict the occurrence of anatomic fit mismatch. We hypothesized that the smaller the humerus size, the greater the anatomic fit mismatch with EADHP. Methods: Twenty humeri were analyzed in this study. Humeral length and distal humeral width were used as parameters of humeral size. Plate protrusion was measured between the EADHP distal tip and the distal humerus. We set the level of unacceptable EADHP anatomic fit mismatch as ≥10 mm plate protrusion. Results: A significant negative linear correlation was also confirmed between humeral size and plate protrusion, with a coefficient of determination of 0.477 for humeral length and 0.814 for distal humeral width. The cutoff value of humeral length to avoid ≥10 mm plate protrusion was 293.6 mm (sensitivity, 88.9%; specificity, 81.8%) and for distal humeral width was 60.5 mm (sensitivity, 100%; specificity, 81.8%). Conclusions: Anatomic fit mismatch in distal humeral fractures after EADHP fixation has a negative linear correlation with humeral length and distal humeral width. For patients with a distal humeral width <60.5 mm, ≥10 mm plate protrusion will occur when an EADHP is used, and an alternative implant or approach should be considered.

Stabilization of Recurrent Medial Shoulder Luxation by Use of Three Bone Anchors in a Dog (재발성 내측 어깨 탈구를 보이는 개에서 본 앵커를 이용한 외과적 치료 증례)

  • Yoon, Hun-Young;Roh, Mi-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.30 no.1
    • /
    • pp.45-48
    • /
    • 2013
  • A 12-year-old male poodle weighing 2.0 kg presented for evaluation of right thoracic limb lameness. The owner reported that the dog showed recurrent bilateral shoulder joint luxation after a car accident for a year. Recently, the left shoulder joint appeared well maintained, but right shoulder joint luxation was exacerbated. On physical examination, the dog showed non-weight bearing lameness on the right thoracic limb. Craniocaudal radiographic views revealed medial displacement of the right humerus. Mediolateral radiographic views revealed overlap of the glenoid cavity and humeral head. Muscle atrophy of the right thoracic limb, reduced biceps brachii muscle tendon tone, a tear of the medial glenohumeral ligament, and a rupture of the subscapularis tendon were identified intraoperatively. Transposition of the biceps muscle tendon was performed. However, at 7 days, there was evidence of right shoulder reluxation on radiographs. The second surgery was performed with two $2mm{\times}6mm$ cortical bone anchors and a $4mm{\times}6mm$ cancellous bone anchor placed in the cortical bone of the distal scapula and the cancellous bone of the proximal humerus respectively. Two scapular bone anchors were then connected with a humeral bone anchor using heavy nylon suture to minimize shoulder abduction range of motion. On radiographs right after surgery and 6 weeks after surgery, the affected limb revealed no evidence of medial shoulder luxation. At 6 months, no evidence of lameness was noted on the right thoracic limb.

Surgical treatment of Giant Cell Tumor in Knee Joint (슬관절 주위 거대세포종의 치료)

  • Bae, Dae-Kyung
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.1
    • /
    • pp.1-6
    • /
    • 1995
  • Giant cell tumors are primary bone tumors originating from non-osteoblastic connective tissue. The sites of involvement were commonly distal femur, proximal tibia, proximal humerus, distal radius and others (including os calcis, ilium and sacrum). Giant cell tumor located around knee joint has been difficult to treat because of local recurrence following curettage with or without bone graft. Although primary resections reduce recurrence of the lesion, the joint function will be markedly impaired. Marginal excision was very often complicated by a loss of joint integrity since all the giant cell tumors occupy juxtaarticular positions. Techniques involving physical adjuncts(high speed burr and electric cauterization) have been used in the hope of decreasing the rate of local recurrence and avoiding the morbidity of primary resection. A meticulous clinical, radiological and histological evaluation is needed to choose the correct treatment, keeping in mind the possibility of recurrence after each treatment modality.

  • PDF

Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty

  • Jo, Young-Hoon;Lee, Seung Gun;Kook, Incheol;Lee, Bong Gun
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.152-155
    • /
    • 2020
  • Periprosthetic fracture after total elbow replacement surgery is a difficult complication to manage, especially when it comes together with implant loosening. If stem revision and internal fixation of the periprosthetic fracture are performed simultaneously, this would be a very challenging procedure. Most of total elbow replacement implants are cemented type. Cement usage at periprosthetic fracture site may interfere healing of fractured site. Authors underwent internal fixation with use of locking plate and cerclage wire for periprosthetic fracture, allogenous fibular strut bone inserted into the humerus intramedullary canal allowing the fractured site to be more stable without cement usage. At 10-month follow-up, the complete union and good clinical outcome was achieved. We present a novel technique for treating periprosthetic fracture with implant loosening after total elbow replacement surgery, using intramedullary allogenous fibula strut bone graft.