• Title/Summary/Keyword: Humeral shaft fracture

Search Result 28, Processing Time 0.024 seconds

Results of the Autogenous Sural Nerve Graft for Ruptured Radial Nerve in the Closed Humerus Shaft Fracture (상완골 골절과 동반된 요골 신경 손상에서 자가 비복 신경 이식술의 결과)

  • Lee, Jun-Mo;Lim, Young-Jin;Park, Jong-Hyuk
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.2
    • /
    • pp.138-143
    • /
    • 2005
  • In the high radial nerve palsy caused by displaced humeral shaft fracture, radial nerve have to be explored in the fracture site. 5 cases of the ruptured radial nerve at the fracture site of the humerus from January 1993 through January 2005 were treated at first by open reduction and internal fixation with plates and screws fixation and then defective radial nerves were grafted with autogenous sural nerves by microsurgical epineurial and or perineurial neurorrhaphy. At average 30.4 months follow-up, 5 cases were recovered from motor and sensory deficit with solid bony union of the humerus shaft fracture. Authors have confirmed that ruptured radial nerve in the humerus shaft fracture grafted with autogenous sural nerve with microsurgical epineurial and or perineurial neurorrhaphy would be expected good motor and sensory recovery.

  • PDF

Open Intramedullary Nail with Tension Band Sutures on Proximal Humeral Fracture (상완골 근위부 골절에 시행한 긴장 대 봉합을 동반한 관혈적 골수강내 고정술)

  • Park, Jin-Young;An, Jin-Woo;Lee, Sung-Churl
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.2
    • /
    • pp.149-160
    • /
    • 2003
  • Purpose: to determine the results after open intramedullary nailing and tension band suture technique in proximal humerus fracture for improving the stability and decreasing the complications. Materials and Method: Authors reviewed 27 patients treated by open intramedullary nailing and tension band suture technique. Mean follow-up period was 39 months (24-59months). Surgical neck fracture were 6 cases, surgical neck fracture with shaft fracture were 3 cases, three part fracture with greater tuberosity fracture were 17 cases, four part fracture was 1 case and fracture and dislocation were 2 cases Results: We got the bony union in 26 cases. Average pain scale was 1 point (0-6), Neer score was 86 point(45-99) and ASES score was 85 point(40-100). We separate all cases in two groups based on age (65 years), L-spine t-score (-2.5) and Neer classification (2 and 3 part). There is no significance in pain scale, Neer score and ASES score between each group. Conclusion: As a method of surgical treatment on severe proximal humeral fractures, we recommend intramedullary nailing and tension band suture technique and it may have particular advantages in early exercise and satisfactory functional outcome.

Shoulder Function after antegrade intramedullary interlocking nailing for humeral shaft fracture (상완골 간부 골절에 대한 선행성 교합 골수강내 금속정 고정술 후 견관절 기능)

  • Park, Jin-Young;Chun, Ji-Yong;Kim, Myung-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.1
    • /
    • pp.27-36
    • /
    • 2003
  • Antegrade interlocking intramedullary nailing (AIIN) for the humeral shaft fracture can induce shoulder pain and decrease of shoulder function postoperatively. The purpose of this study was to estimate the outcome of the shoulder functions after AIIN through the rotator interval between the subscapularis and the supraspinatus to decrease the shoulder pain. Out of consecutive 43 cases that underwent AIIN 42 had been followed for two years or more. Among them we analysized 40 cases of 39 Patients excluding two cases of Pathologic fractures. The average was 47 years. There were 17 men and 23 women. The average follow-up was 34 months. Open nailing was performed in 26 fractures and closed nailing in 14. Bone graft was done in 7 fractures with open nailing. With a single operation, all but two patients achieved osseous union. Average pain score with visual analog scale was one (range; 0∼4) postoperatively By the Neer's score 37 patients received a excellent or satisfactory results while 3 patients' unsatisfactory or failed results. By the functional score of ASES (American Shoulder and Elbow Society) 6 cases received the fair or poor results. Except three cases with persistent nerve palsy and one case of technique failure with protruded nail over humeral head, all patients could achieved satisfactory results with Neer's score and 35 cases (94%) satisfactory results with functional score of ASES. An insertion of antegrade nail to the rotator interval was recommended for better shoulder functions and less pain postoperatively.

Efficacy of Additive Trans-cuff Augmentation Sutures for Proximal Humeral Fractures Stabilized by Locking Plates in Elderly Patients

  • Cho, Nam Su;Shim, Hee Seok;Lee, Sang Hyeon;Jeon, Jong Wook;Rhee, Yong Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.2
    • /
    • pp.68-74
    • /
    • 2015
  • Background: The purpose of our study was to evaluate the functional and radiologic outcomes of additive augmentation sutures through rotator cuff for proximal humeral fractures stabilized locking plate in elderly patients. Methods: We enrolled 74 patients over the age of 60 years who received internal fixation using locking plates for proximal humeral fractures. Of these, 50 patients had additive augmentation sutures through rotator cuff. The mean age at the time of surgery was 72.1 years (range, 60-89 years), and the mean follow-up period was 17.5 months (range, 12-62 months). The humeral neck-shaft angle and humeral head height were used as radiological markers to assess the effect of additive augmentation sutures through rotator cuff. We allocated the patients who received additive augmentation sutures into group A and those who did not into group B. Results: At the final follow-up, the mean Korean Showlder Society score and Constant scores were $88.96{\pm}12.1$ and $86.6{\pm}11.9$, respectively, in group A and $86.21{\pm}11.8$ and $85.3{\pm}11.7$, respectively, in group B (p=0.368, 0.271). At the final follow-up, the mean loss in humeral neck-shaft angle from the time of immediate postoperative measurement was $1.6^{\circ}$ in group A and $4.8^{\circ}$ in group B, whereas the mean loss in humeral head height was 0.82 mm in group A and 0.52 mm in group B (p=0.029, 0.178). Conclusions: The surgical outcomes of internal fixation using locking plates for proximal humeral fractures were clinically and radiologically good in elderly patients over the age of 60 years without any observable complications. Further, the loss of humeral head shaft angle at the final follow-up from its initial postoperative measurement was significantly smaller in patients who received an additive augmentation suture than in those who did not. Thus, we conclude that augmentation sutures are a beneficial option for elderly patients that clinicians can consider at the time of surgical decision making.

Comparison of Radiologic and Clinical Results between Locking Compression Plate and Unlocked Plate in Proximal Humerus Fractures (근위 상완골 골절에서 잠김 압박 금속판과 비잠김 금속판 고정의 방사선학적 임상적 추시 결과 비교)

  • Kim, Jae-Hwa;Lee, Yun-Seok;Ahn, Tae-Keun;Choi, Jung-Pil
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.143-149
    • /
    • 2008
  • Purpose: The purpose of this study is to compare the results of using a locking compression plate and an unlocked plate for treating proximal humeral fractures. Materials and Methods: This study was based on 20 patients who underwent plate fixation for proximal humeral fractures out of the 87 patients with proximal humeral fractures and who were admitted from 2003 to 2007 in our hospital. Of the 20 patients, 10 were treated with a locking compression plate and the other 10 were treated with an unlocked plate. Each group was evaluated according to the humeral neck shaft angle, the period until bony union, the complications and the Constant score. The humeral neck shaft angle was based on plain x-rays taken immediately after the operation and at 6 months postoperatively. The Constant score was evaluated on the last visit to our clinic. Results: There was no significant statistical difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. Yet, there were three cases of screw migration in the unlocked plate group. Conclusion: There was no significant difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. The locking compression plate is considered to achieve more effective fixation for proximal humerus fractures because there were less complications such as screw migration.

Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty

  • Jo, Young-Hoon;Lee, Seung Gun;Kook, Incheol;Lee, Bong Gun
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.152-155
    • /
    • 2020
  • Periprosthetic fracture after total elbow replacement surgery is a difficult complication to manage, especially when it comes together with implant loosening. If stem revision and internal fixation of the periprosthetic fracture are performed simultaneously, this would be a very challenging procedure. Most of total elbow replacement implants are cemented type. Cement usage at periprosthetic fracture site may interfere healing of fractured site. Authors underwent internal fixation with use of locking plate and cerclage wire for periprosthetic fracture, allogenous fibular strut bone inserted into the humerus intramedullary canal allowing the fractured site to be more stable without cement usage. At 10-month follow-up, the complete union and good clinical outcome was achieved. We present a novel technique for treating periprosthetic fracture with implant loosening after total elbow replacement surgery, using intramedullary allogenous fibula strut bone graft.

Tension Band Sutures Using a Washer for a Proximal Humerus Fracture

  • Kim, Kyung-Cheon;Rhee, Kwang-Jin;Shin, Hyun-Dae;Byun, Ki-Yong;Yang, Jae-Hoon;Kim, Dong-Kyu;Kim, Joung-Hun
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2009.03a
    • /
    • pp.161-161
    • /
    • 2009
  • To prevent distraction and varus deformity between the humeral head and shaft, tension band sutures placed between the head of the interlocking screw and the rotator cuff, and we recommend using nonabsorbable sutures. We describe our simple procedure to overcome these difficulties in tension band suturing after reducing a proximal humerus fracture to maintain the reduction.

  • PDF

Antegrade Interlocking Intramedullary Nailing in Humeral Shaft Fractures (상완골 간부 골절에서의 전향적 교합성 골수강내 금속정 고정술)

  • Cho, Chul-Hyun;Song, Kwang-Soon;Kim, Sin-Ki
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • Purpose: To evaluate the results and complications of antegrade intramedullary interlocking nailing in humerus shaft fractures. Materials and Methods: We evaluated the clinical outcomes, radiologic results and complications in 47 patients with humerus shaft fracture treated with antegrade intramedullary interlocking nailing, and followed up until bony union. Bony union was confirmed by serial plain radiographs and the clinical outcomes were assessed according to the ASES scoring system. Results: Bony union was confirmed in 41 (87.2%) out of a total 47 patients, and the mean union period was 14.5 weeks. Major complications were as follows: 6 non-union, 3 delayed union, 2 intraoperative posterior cortex fracture in the distal humerus and 2 permanent shoulder pain, including 1 case of adhesive capsulitis. The clinical outcomes were as follows: 29 excellent, 11 good, 4 fair and 3 poor. Satisfactory outcomes were demonstrated in 40 patients (85.1%). Conclusion: Anterograde intramedullary interlocking nailing as treatment for humerus shaft fracture showed satisfactory bony union and clinical outcomes. It is considered an efficacious treatment, especially in patients with associated injury, such as multiple fractures and segmental fracture.

Internal Fixation with a Locking T-Plate for Proximal Humeral Fractures in Patients Aged 65 Years and Older

  • Yum, Jae-Kwang;Seong, Min-Kyu;Hong, Chi-Woon
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.217-221
    • /
    • 2017
  • Background: The purpose of this study was to evaluate the clinical and radiographic outcomes of internal fixation with locking T-plates for osteoporotic fractures of the proximal humerus in patients aged 65 years and older. Methods: From January 2007 through to December 2015, we recruited 47 patients aged 65 years and older with osteoporotic fractures of the proximal humerus. All fractures had been treated using open reduction and internal fixation with a locking T-plate. We classified the fractures in accordance to the Neer classification system; At the final follow-up, the indicators of clinical outcome-the range of motion of the shoulder (flexion, internal rotation, and external rotation) and the presence of postoperative complications-and the indicators of radiographic outcome-the time-to-union and the neck-shaft angle of the proximal humerus-were evaluated. The Paavolainen method was used to grade the level of radiological outcome in the patients. Results: The mean flexion was $155.0^{\circ}$ (range, $90^{\circ}-180^{\circ}$), the mean internal rotation was T8 (range, T6-L2), and the mean external rotation was $66.8^{\circ}$ (range, $30^{\circ}-80^{\circ}$). Postoperative complications, such as plate impingement, screw loosening, and varus malunion were observed in five patient. We found that all patients achieved bone union, and the mean time-to-union was 13.5 weeks of the treatment. The mean neck-shaft angle was $131.4^{\circ}$ at the 6-month follow-up. According to the Paavolainen method, "good" and "fair" radiographic results each accounted for 38 and 9 of the total patients, respectively. Conclusions: We concluded that locking T-plate fixation leads to satisfactory clinical and radiological outcomes in elderly patients with proximal humeral fractures by providing a larger surface area of contact with the fracture and a more rigid fixation.