• 제목/요약/키워드: Human mock circulation system

검색결과 3건 처리시간 0.014초

혈관 삽입용 초소형 작동형 내시경의 개발(II) - 시스템 설계, 제작 및 체외 성능 분석 - (Development of Intravascular Micro Active Endoscope(II) -System Design, Fabrication and In-vitro Evaluation-)

  • 장준근;정석;이용구
    • Tribology and Lubricants
    • /
    • 제15권3호
    • /
    • pp.278-286
    • /
    • 1999
  • To predict the behavior of the intravascular micro active endoscope in the real human vascular system, a human mock circulation system was developed. The intravascular micro active endoscope which consists of micro active bending catheter and micro drug infusion catheter was driven in the velocity, Re number and temperature controlled flow. The three SMA (Shape Memory Alloy) zigzag type spring in the micro active bending catheter was heated by the electric current generated by PWM controller, and the shape memory effect made the actuator bend to any direction. The micro drug infusion catheter was driven through the inner hole of the micro active bending catheter. A mock circulation system is shaped from Ascending Arota to Femoral artery according to a human data (the data contains many vascular sizes and hydrographs of many control points). We developed a vascular model with glass and silicone tubes, and set the flow system with circulation parts, flow settling parts, and lots of valves. The heater and heat-controller was added to the How system to centre! the temperature of the How at 36.5$^{\circ}C$. The result showed that the developed intravascular micro active endoscope could be induced to any point in the vascular model.

인조신경망을 이용한 좌심실보조장치의 동적 모델링

  • 김훈모
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.346-350
    • /
    • 1996
  • This paper presents a Neural Network Identification (NNI) method for modeling of highly complicated nonlinear and time varing human system with a pneumatically driven mock circulation system of Left Ventricular Assist Device(LVD). This system consists of electronic circuits and pneumatic driving circuits. The initation of systole and the pumping duration can be determined by the computer program. The line pressure from a pressure transducer inserted in the pneumatic line was recorded. System modeling is completed using the adaptively trained backpropagation learning algorithms with input variables, Heart Rate(HR), Systole-Diastole Rate(SDR), which can vary state of system, and preload, afterload, which indicate the systemic dynamic characteristics and output parameters are preload, afterload.

  • PDF

좌심실 전동순환 보조장치에 관한 연구 (Study on Electrically Powered Left Ventricular Circulation Assist Device)

  • 김명남;이정우;장봉현;조진호
    • 센서학회지
    • /
    • 제9권1호
    • /
    • pp.51-60
    • /
    • 2000
  • 본 논문에서는 정상류형 혈액 펌프의 일종인 축류형 혈액 펌프를 이용하여 혈액 펌프 시스템을 설계하였다. 이 시스템은 혈액 펌프, 신호 획득부, 인터페이스부, 신호 처리부로 구성되어 있고, 혈압과 심박수를 이용하여 혈압과 혈류량을 적절히 제어함으로써 좌심실의 기능을 보조할 목적으로 연구되었다. 전동 펌프가 회전할 때 생체내의 순환조건에 알맞도록 혈액 펌프의 회전수, 혈액 펌프에 걸리는 부하와 압력 정보를 적용하여 실험식을 만들어 제어에 이용하였으며 설계 제작된 모의 순환장치로써 실험한 결과 모의 혈관 내에서 적절한 혈압과 혈류의 제어가 가능하였고, 혈구의 변화량 실험 결과는 임시의 목적으로 사용가능 함을 알 수 있었다.

  • PDF