• Title/Summary/Keyword: Human gait motion

Search Result 91, Processing Time 0.035 seconds

Comparison of Three-Dimensional Dynamic Simulation with Falling Gait Analysis (헛디딤 보행특성과 3 차원 모의해석결과 비교)

  • 명성식;금영광;황성재;김한성;김영호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.359-363
    • /
    • 2004
  • Numerous studies have been performed to analyze various phenomena of human's walking, gait. In the present study, unrecognized walking and recognized walking were analyzed by three dimensional motion capture system(VICON motion system Ltd., England) and simulated by computer program. Two normal males participated in measuring the motion of unrecognized and recognized walking. Six infrared cameras and four force plates were used and sixteen reflective markers were attached to the subject to capture the motion. A musculoskeletal model was generated anatomically by using ADAMS(MSC software corp., USA) and LifeMOD(Biomechanics Research Group Inc, USA). The inverse dynamic simulation and forward dynamic simulation were also performed. The result of simulation was similar to the experimental result. This study provides the base line for dynamic simulation of the falling walking. It will be useful to simulate various another pathologic gaits for old peoples.

  • PDF

Statistical Modeling Methods for Analyzing Human Gait Structure (휴먼 보행 동작 구조 분석을 위한 통계적 모델링 방법)

  • Sin, Bong Kee
    • Smart Media Journal
    • /
    • v.1 no.2
    • /
    • pp.12-22
    • /
    • 2012
  • Today we are witnessing an increasingly widespread use of cameras in our lives for video surveillance, robot vision, and mobile phones. This has led to a renewed interest in computer vision in general and an on-going boom in human activity recognition in particular. Although not particularly fancy per se, human gait is inarguably the most common and frequent action. Early on this decade there has been a passing interest in human gait recognition, but it soon declined before we came up with a systematic analysis and understanding of walking motion. This paper presents a set of DBN-based models for the analysis of human gait in sequence of increasing complexity and modeling power. The discussion centers around HMM-based statistical methods capable of modeling the variability and incompleteness of input video signals. Finally a novel idea of extending the discrete state Markov chain with a continuous density function is proposed in order to better characterize the gait direction. The proposed modeling framework allows us to recognize pedestrian up to 91.67% and to elegantly decode out two independent gait components of direction and posture through a sequence of experiments.

  • PDF

Gait Implementation of a Biped Robot with Smooth Walking Pattern (유연한 보행 형태를 갖는 이족보행로봇의 걸음새 구현)

  • No, Gyeong-Gon;Gong, Jeong-Sik;Kim, Jin-Geol;Kim, Gi-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.7
    • /
    • pp.43-50
    • /
    • 2002
  • This paper presents the new gait implementation of a biped robot with smooth walking using 3-dimensional continuous trunk motion and kick action of ankle joints. Trajectory generation ova trunk is performed not on a unit gait but on a whole walking interval. In applying kick action such as heel-touch or toe-off, varying coordinate system was employed for the simplification of the kinematic analysis. Desired ZMP (zero moment point) is also changed to implement the efficient kick action. As a result, balancing motion of the proposed gait was much more decreased than that of conventional one. Moreover, robot\\`s walking behavior is very smooth, natural and similar to the pace of a human. The walking experiment system is composed of eight AC servo motors and a DSP controller. The walking simulation and the experimental results are shown using the proposed new walking algorithm.

Changes of Lower Limb Joints Stiffness with Gait Speed in Knee Osteoarthritis (무릎 골관절염 환자의 보행속도에 따른 하지 관절 강성 변화)

  • Park, Hee-Won;Park, Su-Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.7
    • /
    • pp.723-729
    • /
    • 2012
  • Spring-like leg models have been employed to explain various dynamic characteristics in human walking. However, this leg stiffness model has limitations to represent complex motion of actual human gait, especially the behaviors of each lower limb joint. The purpose of this research was to determine changes of total leg stiffness and lower limb joint stiffness with gait speed in knee osteoarthritis. Joint stiffness defined as the ratio of the joint torque change to the angular displacement change. Eight subjects with knee osteoarthritis participated to this study. The subject walked on a 12 m long and 1 m wide walkway with three sets of four different randomly ordered gait speeds, ranging from their self-selected speed to maximum speed. Kinetic and kinematic data were measured using three force plates and an optical marker system, respectively. Joint torques of lower limb joints calculated by a multi-segment inverse dynamics model. Total leg and each lower limb joint had constant stiffness during single support phase. The leg and hip joint stiffness increased with gait speed. The correlation between knee joint angles and torques had significant changed by the degree of severity of knee osteoarthritis.

Effect of a Elderly Walker on Joint Kinematics and Muscle Activities of Lower Extremities Using a Human Model (인체 모델을 이용한 노인 보행기의 하지관절 기구학과 근활성에 미치는 영향)

  • Shin, Jun-Ho;Kim, Yoon-Hyuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1243-1248
    • /
    • 2011
  • The purposes of this study were to develop a dynamic model of a human and to investigate the effect of a walker on an elderly subject's motions, such as sit-to-stand (STS) motion and normal gait, by using this model. A human model consisting of 15 segments and 14 joints was developed, embedded in $RecurDyn^{TM}$, and connected through a Simulink$^{(R)}$ interface with collected motion data. The model was validated by comparisons between joint kinematic results from inverse dynamics (Matlab$^{(R)}$-based in-house program) and from $RecurDyn^{TM}$ simulation during walking. The results indicate that the elderly walker induced a longer movement time in walking, such that the speed of joint flexion/extension was slower than that during a normal gait. The results showed that the muscle activities of parts of the ankle and hamstring were altered by use of the elderly walker. The technique used in this study could be very helpful in applications to biomechanical fields.

A Novel System with EMG-controlled FES Enhanced Gait Function and Energy Expenditure for Older Adults

  • Jang-hoon Shin;Hye-Kang Park;Joonyoung Jung;Dong-Woo Lee;Hyung cheol Shin;Hwang-Jae Lee;Wan-hee Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.2
    • /
    • pp.152-162
    • /
    • 2024
  • Objective: This study was conducted to analyze the effect of wearable Electromyography-controlled functional electrical stimulation (EMG-controlled FES) System on Gait Function and cardiopulmonary metabolic efficiency during walking in older adults. Design: Cross-section study Methods: Total 22 older adult participants suitable to selection criteria of this study participated in this study. The EMG-controlled FES System, which functions as a wearable physical activity assist FES system was used. All participations performed randomly assigned two conditions (Non-FES assist [NFA], FES assist [FA]) of walking. In all conditions, spatio-temporal parameters and kinematics and kinetics parameters during walking was collected via 3D motion capture system and 6 minutes walking test (6MWT) and metabolic cost during walking and stairs climbing was collected via a portable metabolic device (COSMED K5, COSMED Srl, Roma, Italy). Results: In Spatio-temporal parameters aspects, The EMG-controlled FES system significantly improved gait functions measurements of older adults with sarcopenia at walking in comparison to the NFA condition (P<0.05). Hip, knee and ankle joint range of motion increased at walking in FA condition compared to the NFA condition (P<0.05). In the FA condition, moment and ground reaction force was changed like normal gait during walking of older adults in comparison to the NFA condition (P<0.05). The EMG-controlled FES system significantly reduced net cardiopulmonary metabolic energy cost, net energy expenditure measurement at stairs climbing (P<0.05). Conclusions: This study demonstrated that EMG-controlled FES is a potentially useful gait-assist system for improving gait function by making joint range of motion and moment properly.

Gait Recognition Using Multiple Feature detection (다중 특징점 검출을 이용한 보행인식)

  • Cho, Woon;Kim, Dong-Hyeon;Paik, Joon-Ki
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.6
    • /
    • pp.84-92
    • /
    • 2007
  • The gait recognition is presented for human identification from a sequence of noisy silhouettes segmented from video by capturing at a distance. The proposed gait recognition algorithm gives better performance than the baseline algorithm because of segmentation of the object by using multiple modules; i) motion detection, ii) object region detection, iii) head detection, and iv) active shape models, which solve the baseline algorithm#s problems to make background, to remove shadow, and to be better recognition rates. For the experiment, we used the HumanID Gait Challenge data set, which is the largest gait benchmarking data set with 122 objects, For realistic simulation we use various values for the following parameters; i) viewpoint, ii) shoe, iii) surface, iv) carrying condition, and v) time.

Seafarers Walking on an Unstable Platform: Comparisons of Time and Frequency Domain Analyses for Gait Event Detection

  • Youn, Ik-Hyun;Choi, Jungyeon;Youn, Jong-Hoon
    • Journal of information and communication convergence engineering
    • /
    • v.15 no.4
    • /
    • pp.244-249
    • /
    • 2017
  • Wearable sensor-based gait analysis has been widely conducted to analyze various aspects of human ambulation abilities under the free-living condition. However, there have been few research efforts on using wearable sensors to analyze human walking on an unstable surface such as on a ship during a sea voyage. Since the motion of a ship on the unstable sea surface imposes significant differences in walking strategies, investigation is suggested to find better performing wearable sensor-based gait analysis algorithms on this unstable environment. This study aimed to compare two representative gait event algorithms including time domain and frequency domain analyses for detecting heel strike on an unstable platform. As results, although two methods did not miss any heel strike, the frequency domain analysis method perform better when comparing heel strike timing. The finding suggests that the frequency analysis is recommended to efficiently detect gait event in the unstable walking environment.

Vertical Limb Stiffness Increased with Gait Speed in the Elderly (노인군 보행 속도 증가에 따른 하지 강성 증가)

  • Hong, Hyun-Hwa;Park, Su-Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.6
    • /
    • pp.687-693
    • /
    • 2011
  • Spring-mass models have been widely accepted to explain the basic dynamics of human gait. Researchers found that the leg stiffness increased with gait speed to increase energy efficiency. However, the difference of leg stiffness change with gait speed between the young and the elderly has not been verified yet. In this study, we calculated the lower limb stiffness of the elderly using walking model with an axial spring. Vertical stiffness was defined as the ratio of the vertical force change to the vertical displacement change. Seven young and eight elderly subjects participated to the test. The subjects walked on a 12 meter long, 1 meter wide walkway at four different gait speeds, ranging from their self-selected speed to maximum speed randomly. Kinetic and kinematic data were collected using three force plates and motion capture cameras, respectively. The vertical stiffness of the two groups increased as a function of walking speed. Maximum walking speed of the elderly was slower than that of the young, yet the walking speed correlated well with the optimal stiffness that maximizes propulsion energy in both groups. The results may imply that human may use apparent limb stiffness to optimize energy based on spring-like leg mechanics.