• Title/Summary/Keyword: Human Pulse

검색결과 338건 처리시간 0.028초

대장정격 및 승격 자침이 정상 성인의 맥파에 미치는 영향 비교 연구 (The Effects of Sa-Am Acupuncture on Radial Pulse in Healthy Subjects: A Comparative Study of Large Intestine Tonifying and Sedating)

  • 조은;이현
    • Journal of Acupuncture Research
    • /
    • 제31권3호
    • /
    • pp.7-18
    • /
    • 2014
  • Objectives : The purpose of this study is to find parameters to compare the effects of Sa-Am acupuncture with large intestine tonifying and sedating on radial pulse in healthy subjects. Methods : Sixty healthy subjects participated in this study, divided into large intestine tonifying acupuncture group, large intestine sedating acupuncture group and control group. Radial pulse was measured by 3 dimensional pulse imaging system(DMP-3000) before, right after, 30 minutes after and 60 minutes after acupuncture at Cun, Guan, and Chi in the acupuncture group and in the control group at the same time points. Results : 1. Angle of main peak and magnitude of fourier component significantly changed by integrated analysis of Cun, Guan and Chi. 2. Amplitude of H1, Pulse Power volume / min, elasticity, AIx / HR, Frequency and magnitude of fourier component significantly changed by analysis of Cun, Guan, and Chi. Conclusions : The effect of Sa-Am acupuncture with large intestine tonifying and sedating in healthy human may be observed on time, amplitude, pulse area, augmentation index and fourier components parameters. The parameters analysed in this study may be used to differentiate the effects between Sa-Am acupuncture with large intestine tonifying and sedating on radial pulse. Further studies on the effects of Sa-Am acupuncture using radial pulse are needed.

8체질(體質) 설문지(說問紙)의 타당도(妥當度), 신뢰도(信賴度)에 관한 연구(硏究) (A Study on the Validity and Reliability of the Eight-Constitution Questionnaire)

  • 민재영;김민용;박영재;박영배
    • 대한한의진단학회지
    • /
    • 제11권2호
    • /
    • pp.27-44
    • /
    • 2007
  • Background: Eight-Constitution Medicine (ECM) classifies the human body into eight constitutions. Diagnosis of discrimination of the eight constitutions depends on a unique pulse diagnosis. However, pulse diagnosis is subjective and requires vigorous training. Objectives: This study aims to analyze the validity and reliability of the Eight-Constitution Questionnaire as a diagnostic method. Methods: Participants of this study were outpatients in six ECM clinics located in Seoul. The resources were collected from 409 patients who were classified into one of the eightconstitutions according to their pulse types and their responses to constitution-acupuncture therapy. SPSS 13.0 for Windows was used for statistical analysis: factor analysis, reliability analysis, independent sample t-test, and multinomial logistic regression were used to verify the results. Results and Conclusions: 1. The proportion of participants' constitutions is in the order of Pancreotonia (23.7%), Colonotonia (19.8%), Pulmotonia (18.1%), Hepatonia (16.9%), Vesicotonia (8.1%), Cholecystotonia (7.3%), Renotonia (5.3%) and Gastrotonia (0.7%). 2. Sevencomponents and 74 items were selected through factor factor and relaibility analysis performed on about 251 items. 3. The firstcomponent's mean is significantly higher in Pancreotonia than that in other constitutions (p<0.05). The second is in Pulmotonia and Colonotonia, whereas the third is in Hepatonia and Cholecystotonia. Fifth is in Vesicotonia, the sixth is in Colonotonia, and the fourth and seventh are not significant in specific constitutions. 4. The percentage that Pancreotonia is correctly predicted is 96.9%, Pulmotonia is 91.9%, Colonotonia is 91.4%, Hepatonia is 88.4%, Vesicotonia is 81.8%, Gastrotonia is 66.7%, Renotonia is 66.7%, Choleeystotonia is 30.0%, and the total percentage is 85.3%.

  • PDF

조합형 광섬유 트랜스듀서에 의한 요골맥파의 검출 (Detection of Radial Pulse by Combinational Fiber-optic Transducer)

  • 박승환;홍승홍
    • 센서학회지
    • /
    • 제7권3호
    • /
    • pp.197-202
    • /
    • 1998
  • 맥파신호는 심장과 심혈관계에 관련된 중요한 정보를 포함하고 있는 중요한 생체신호이다. 본 연구에서는 맥파신호를 비관혈적으로 검출하기 위해 기존의 기계적 변환방식의 개념에 근거하여 광섬유를 이용하는 맥파 검출용 트랜스듀서를 새로이 개발하여 사용하였다. 기계적 변환방식에서 발생될 수 있는 맥동전달 효율을 개선시키기 위해 본 연구에서는 맥동하는 피부와 접촉하여 센서에 전달하는 검출부(detecting part)와, 전달받은 변위운동을 광 출력 변화에 따른 전기 신호로 변환하는 감지부(sensing part)의 두 부분이 조합된 구조를 갖는 설계방식을 제안하였다. 우리는 이러한 조합형 구조의 설계방식을 이용한 결과로 기존의 트랜스듀서로 검출이 어려운 맥파의 C점(절흔)과 T파를 검출할 수 있음을 확인하였다.

  • PDF

맥진 객관화를 위한 디지탈 맥진기의 진단 파라메터 연구 (A Study of Digital EPG Diagnosis Parameter for EPG Standardization)

  • 이준영;김정훈;서현우;이정환;이병채;이명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3243-3244
    • /
    • 2000
  • From ancient times, the diagnosis method of the oriental medicine has been performed by curing diseases by means of rectifying and adjusting the unbalance in the physiological function of the five viscera and the six bowels of a human body. Diseases have been diagnosed by the condition of blood circulation that cycles a human body through blood vessels by dint of the vitality of the heart. Based on such a systematic pulse diagnosis method, the article presents parameters that will be beneficial to clinical application on the basis of its analysis of the filtering for eliminating noises from pulse signals inputted from sensor group, the digital hardware dealing with signals necessary for recognition algorithm, and the structure of diagnosis algorithm and components of pulse waveform.

  • PDF

폐정격(肺正格) 자침이 촌관척(寸關尺) 맥파 변화에 미치는 영향 (The Effect of Sa-Am Lung Tonifying Acupuncture on Radial Pulse in Healthy Human Subjects)

  • 김나연;강재희;이현
    • Journal of Acupuncture Research
    • /
    • 제29권5호
    • /
    • pp.17-29
    • /
    • 2012
  • Objectives : The purpose of this study is to find the effects of Sa-Am lung tonifying acupuncture on radial pulse through the parameters difference. Methods : Forty healthy subjects participated in this study, acupuncture group and control group were divided. Compared various parameters of radial pulse between two groups, and the significantly changed 16 parameters ware measured using 3 dimensional pulse imaging system(DMP-3000) before, right after, 30 minutes after, and 60 minutes after acupuncture at Chon, Gwan, Cheok in acupucture group. Results : After lung tonifying acupuncture, radial pulse 16 parameters were showed changes significantly according to the time at each measuring location. 1. Heart rate, T2/T, T5, T5/T and W/T significantly decreased, W significantly increased. 2. Modulus of elasticity significantly decreased in left Cheok. 3. Amplitude of H4 significantly increased in left Gwan and right Cheok. 4. AIx, AIxHR significantly decreased in left Gwan and significantly increased in right Chon. 5. Area of pulse, area of W significantly increased in right Cheok. 6. Pulse energy, energy/min, EIx significantly decreased in left Cheok. 7. Maximum variation time of each parameter is showed different according to the parameter. Conclusions : Lung tonifying acupuncture exerts an influence on radial purse parameters. Further radial pulse change study on various acupuncture treatment is required.

마왕퇴(馬王堆) 발굴(發掘) 경맥서(經脈書) 비음경(臂陰經) 연구(硏究) : 경맥(經脈)의 직접(直接) 지각(知覺) (Hand-Yin Meridians of Unearthed Mawangdui Medical Texts Were Described by the Haptic Exploration)

  • 송석모
    • 한국의사학회지
    • /
    • 제35권1호
    • /
    • pp.87-99
    • /
    • 2022
  • The purpose of this paper is to test the hypothesis that some early Chinese meridians were described by haptic exploration of the arterial pulse. The method is as follows: First, the relevant passages of the Mawangdui medical texts, the oldest meridian monographs, are translated based on perceptual anatomy. Second, the pulse is haptically searched for in the palm, lower arm, upper arm, armpit, and torso of the human body. Finally, their locations are compared with the translation. As a result, It was confirmed that the pulse locations detected on the body were mostly consistent with the routes of the meridians described in the texts. So meridians were haptically detectable pulse routes. What is known today as the flow direction of hand-yin meridians is actually the direction of searching the pulse. Our result runs counter to Huang Longxiang's claim that the route of the meridians are virtual routes set by speculation. Our findings also dispute Vivien Shaw's claim that the meridians of Mawangdui medical texts were discovered by anatomical dissection. They also refute the claim that meridians were discovered by the extrasensory perception of the inner sight (內觀) and the subjective experience of the meridian sensitive person. The hand-yin meridians of Mawangdui medical texts are well described so that anyone can find them by touching them with their fingers.

인간의 시각특성을 고려한 Sub-Band 부호화에서 MRF 비교에 관한 연구 (On the Comparison of MTF in Sub-Band Coding Technique Employing the Human Visual System)

  • 김용관;박섭형;이상욱
    • 대한전자공학회논문지
    • /
    • 제27권5호
    • /
    • pp.784-792
    • /
    • 1990
  • In this paper, attempts have been made to compare the subjective performance of sub-band coding (SBC) techniques incorporating four representative modulation transfer functions (MTF's) of th human visual system(HVS): Sakrison, Nill, Ngan, and Rao. In SBC, the frequency band of input signal is split into 16 equal sub-bands. In addition, 28 sub-band splitting schemd which splits more sub-bands in low spatial frequency is considered to compare the 4 MTF's effectively. In encoding of each sub-band, the weight of each sub-band obtained from the MTF of HVS is applied to bit allocation process which minimize the weighted mean square error (WMSE). The differential pulse code modulation(DPCM) coder is used to encode the lowest sub-band and the pulse code modulation(PCM) coder is used for the rest of sub-bands. It is found that the images incorporating the MTF of Rao yields the best results in subjective criteria, followed by Ngan, Nill, Sakrison, and the images not employing the HVS.

  • PDF

동적 상태에서 주관적 착용감에 영향을 미치는 직물의 수증기상태의 수분전달 특성 (Moisture Vapor Management Properties of Fabrics Determining Human Sensorial Comfort in Transient Conditions)

  • 유신정
    • 한국의류학회지
    • /
    • 제24권7호
    • /
    • pp.1073-1080
    • /
    • 2000
  • Moisture transfer property of fabrics has known as one of the most important factors deciding wearer's subjective comfort not only thermally but also of sensorial. As a decisive property of fabric materials in determining human sensorial comfort, moisture vapor management property of heat resistant workwear material was examined in terms of increasing and decreasing rate and maximum value of relative humidity in the microclimate under the sweat pulse situation. An unique moisture regulation index, B$_{d}$, was calculated from the measurements using a novel dynamic sweating hot plate apparatus and was used to assess the buffering capacity of fabrics against a moisture vapor sweat pulse.e.

  • PDF

"난경회주전정(難經滙注箋正)"중(中) 맥진(脈診)에 관한 연구(硏究) (Research about pulse diagnostic technique out of "Nan Jing hoeju jeonjung")

  • 박근정;윤창열
    • 혜화의학회지
    • /
    • 제15권2호
    • /
    • pp.39-52
    • /
    • 2006
  • We came to the conclusion as follows from the research about pulse diagnostic technique (脈診) out of "Nan Jinghoeju jeonjung" (難經滙注箋正). 1. "Nan Jing" is practical medical book for clinician and holds different opinions about three portions and nine takings(三部九候脈法) from Huang Di Nei Jing's Taking the pulse of Bu Jung Chim Chon Kwan Chuk((浮中沈 寸關尺) is a quite creative means which has been a important role to future generation. 2. We pointed the differences between western medical science and traditional medical science. And can explain the pulse in western medicine divided from twelve channels of Oriental Medicine. We can explain special connection between heart and lungs using the theory of systemic & pulmonary circulation in western medicine. And this can be a basement of Lung controls every pulse theory in oriental medicine. 3. We have negative assertion about viewing the human body using theory of Yin and Yang-Five Elements. And have poor opinion of explaining about the matching internal organs to Chon Kwan Chuk using the theory of Yin and Yang-Five Elements. 4. We pointed out the mistake that Porak & Sang hwa act for heart. We took pulses considering heart is a real actual internal organ as others. 5. We denied the theory of Man's Chuk pulse is always weak(男子尺脈恒弱) & Woman's Chuk pulse is always strong(女子尺脈恒盛). The physical form of man and woman is not different from each other considering their inheritances from forefather & same shape of organs. So, we cannot insist on the theory.

  • PDF

Chopper Application for Magnetic Stimulation

  • Choi, Sun-Seob;Lee, Sun-Min;Kim, Jun-Hyoung;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • 제15권4호
    • /
    • pp.213-220
    • /
    • 2010
  • Since the hypothalamus immediately reacts to a nerve by processing all the information from the human body and the external stimulus being conducted, it performs a significant role in internal secretion; thus, a diverse and rapid stimulus pulse is required. By detecting Zero Detector accurately via the application of AVR on-Chip (ATMEL) using commercial electricity, chopping generates a stimulus pulse to the brain using an IGBT gate to designate a new magnetic stimulation following treatment and diagnosis. To simplify and generate a diverse range of stimuli for the brain, chopping can be used as a free magnetic stimulator. Then, commercial frequency (60Hz) is chopped precisely at the first level of the leakage transformer to deliver an appropriate stimulus pulse towards the hypothalamus when necessary. Discharge becomes stable, and the chopping frequency and duty-ratio provide variety after authorizing a high-pressure chopping voltage at the second level of the magnetic stimulator. These methods have several aims. The first is to apply a variable stimulus pulse via accurate switching frequency control by a voltaic pulse or a pulse repetition rate, according to the diagnostic purpose for a given hypothalamus. Consequently, the efficiency tends to increase. This experiment was conducted at a maximum of 210 W, a magnetic induced amplitude of 0.1~2.5 Tesla, a pulse duration of $200{\sim}350\;{\mu}s$, magnetic inducement of 5 Hz, stimulus frequency of 0.1~60 Hz, and a duration of stimulus train of 1~10 sec.