• 제목/요약/키워드: Human Impedance

검색결과 201건 처리시간 0.02초

TN-C-S 접지계통에서 외부 루프 임피던스의 실측 및 기준값 설정에 관한 연구 (A Study on the Measurement and Determination of External Loop Impedance on TN-C-S System)

  • 이건호;정진수;문현욱;김선구
    • 전기학회논문지
    • /
    • 제62권8호
    • /
    • pp.1163-1168
    • /
    • 2013
  • The maximum allowable value of loop impedance($Z_s$) to secure the operation of overcurrent protective devices and the safety for indirect contact is a very important in TN-C-S system. The loop impedance is divided into inner loop impedance which consumer can adjust and external loop impedance($Z_e$) which only electric operator can adjust. Thus, an external loop impedance which limits to less than a certain value is a very important factor for human body protection against electric shock in TN-C-S system. The concept of loop impedance($Z_s$) is recently introduced to the domestic, the study about external loop impedance is yet insufficient. However, the study about the reference impedance as specified by the IEC 60725 standard to improve the quality and reliability of the power supply is being made. In this paper, reference value of external loop impedance($Z_e$) to meet domestic environment will be proposed by the nationwide measurement and statistical analysis.

개인차 보상을 고려한 팔운동감의 정량화 방법 (Quantification Method of Kinesthetic Sense of Arm with Compensation for Individual Difference)

  • 정웅철;송재복;김용일
    • 한국정밀공학회지
    • /
    • 제17권2호
    • /
    • pp.227-234
    • /
    • 2000
  • The human sensibility caused by the motion of an object grasped by a human operator is defined as kinesthetic sense of arm. Due to nonlinearity and ambiguity of human sense, there is no absolute standard for quantification of kinesthetic sense. In this research, a so-called 2-dimensional arm motion generator is developed to present various mechanical impedance (i.e., stiffness or damping) characteristics to a human arm. The kinesthetic words representing arm kinesthetic sense are selected and then the subject's satisfaction levels on these words for given impedance values are measured and processed by the SD method and factor analysis. In addition, the quantification method using neural network is proposed to take into account the individual difference between the mean sensibility and each subject's sensibility. Through this proposed algorithm, the sensibility of human motion described qualitatively can be converted into engineering data ensuring objectivity, reproducibility, and universality.

  • PDF

Design and Stability Analysis of Impedance Controller for Bilateral Teleoperation under a Time Delay

  • Cho, Hyun-Chul;Park, Jong-Hyeon
    • Journal of Mechanical Science and Technology
    • /
    • 제18권7호
    • /
    • pp.1131-1139
    • /
    • 2004
  • A new impedance controller is proposed for bilateral teleoperation under a time delay. The proposed controller does not need to measure or estimate the time delay in the communication channel using the force loop-back. In designing a stable impedance controller, absolute stability is used as a stability analysis tool, which results in a less conservative controller than the passivity concept. Moreover, in order to remove the conservatism associated with the assumption of infinite port impedances, the boundaries of human and environment impedance are set to finite values. Based on this, this paper proposes a parameter design procedure for stable impedance controllers. The validity of the proposed control scheme is demonstrated by experiments with a 1-dof master/slave system.

Bioelectrical Impedance Analysis at Popliteal Regions of Human Body using BIMS

  • Kim, J.H.;Kim, S.S.;Kim, S.H.;Baik, S.W.;Jeon, G.R.
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.1-7
    • /
    • 2016
  • Bioelectrical impedance (BI) at popliteal regions was measured using a bioelectrical impedance measurement system (BIMS), which employs the multi-frequency and the two-electrode method. Experiments were performed as follows. First, a constant AC current of $800{\mu}A$ was applied to the popliteal regions (left and right) and the BI was measured at eight different frequencies from 10 to 500 kHz. When the applied frequency greater than 50 kHz was applied to human's popliteal regions, the BI was decreased significantly. Logarithmic plot of impedance vs. frequency indicated two different mechanisms in the impedance phenomena before and after 50 kHz. Second, the relationship between resistance and reactance was obtained with respect to the applied frequency using BI (resistance and reactance) acquired from the popliteal regions. The phase angle (PA) was found to be strongly dependent on frequency. At 50 kHz, the PA at the right popliteal region was $7.8^{\circ}$ slightly larger than $7.6^{\circ}$ at the left popliteal region. Third, BI values of extracellular fluid (ECF) and intracellular fluid (ICF) were calculated using BIMS. At 10 kHz, the BI values of ECF at the left and right popliteal regions were $1664.14{\Omega}$ and $1614.08{\Omega}$, respectively. The BI values of ECF and ICF decreased sharply in the frequency range of 10 to 50 kHz, and gradually decreased up to 500 kHz. Logarithmic plot of BI vs. frequency shows that the BI of ICF decreased noticeably at high frequency above 300 kHz because of a large decrease in the capacitance of the cell membrane.

Comparison of Infiltration Induced in Veins of Rabbit's Ear and Human's Forearm by Using Bioelectrical Impedance: Pilot Study

  • Kim, Jae-Hyung;Hwang, Young-Jun;Kim, Gun-Ho;Shin, Beum-Joo;Kim, Yong-Jin;Lee, Eun-Joo;Jeon, Gye-Rok
    • 센서학회지
    • /
    • 제26권5호
    • /
    • pp.306-313
    • /
    • 2017
  • An early detection of infiltration in veins is essential to minimize the injuries caused during infusion therapy, which is one of the most important tasks for nurses in clinical settings. We report that bioelectrical impedance analysis is useful in the early detection of infiltration at puncture sites. When infiltration was intentionally induced in the vein of a rabbit's ear, impedance parameters showed significant difference before and after infiltration. In particular, the relative resistance at 20 kHz in the vein of rabbit's ear reduced largely at infiltration, decreased slowly, and then stayed at a constant value. This indicates that the vein in the ear of the rabbit is small, and hence the infiltrated intravenous (IV) solution no longer accumulates after 3 minutes of infiltration. However, when infiltration was induced in the vein of a human's forearm, the relative resistance at 20 kHz decreased gradually over time. In the $R-X_c$ graph, the positions in infiltration induced in the rabbit's ear rapidly shifted before and after infiltration whereas the positions in infiltration induced in the human's forearm changed gradually during infiltration. Our findings suggest that bioelectrical impedance analysis is an effective method to detect the infiltration early in a noninvasive and quantitative manners.

Human Arm Posture Control Using the Impedance Controllability of the Musculo-Skeletal System Against the Alteration of the Environments

  • Kim, Jaehyo;Makoto Sato;Yasuharu Koike
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제4권1호
    • /
    • pp.43-48
    • /
    • 2002
  • We show that humans execute the postural control ingeniously by regulating the impedance properties of the musculo-skeletal system as the motor command against the alteration of the environment. Adjusting muscle activity can control the impedance properties of the musculo-skeletal system. To quantify the changes in human arm viscoelasticity on the vertical plane during interaction with the environment, we asked our subject to hold an object. By utilizing surface electromyographic(EMG) studies, we determined a relationship between the perturbation and a time-varying muscle co-activation. Our study showed when the subject lifts the object by himself the muscle stiffness increases while the torque remains the same just before the lift-off. These results suggest that the central nervous system(CNS) simultaneously controls not only the equilibrium point(EP) and the torque, but also the muscle stiffness as themotor command in posture control during the contact task.

Enhanced Common-Mode Noise Rejection Method Based on Impedance Mismatching Compensation for Wireless Capsule Endoscopy Systems

  • Hwang, Won-Jun;Kim, Ki-Yun;Choi, Hyung-Jin
    • ETRI Journal
    • /
    • 제37권3호
    • /
    • pp.637-645
    • /
    • 2015
  • Common-mode noise (CMN) is an unresolved problem in wireless capsule endoscopy (WCE) systems. In a WCE system, CMN originates from various electric currents found within the human body or external interference sources and causes critical demodulation performance degradation. The differential operation, a typical method for the removal of CMN rejection, can remove CMN by subtracting two signals simultaneously received by two reception sensors attached to a human body. However, when there is impedance mismatching between the two reception sensors, the differential operation method cannot completely remove CMN. Therefore, to overcome this problem, we propose an enhanced CMN rejection method. The proposed method performs not only subtraction but also addition between two received signals. Then a CMN ratio can be estimated by sufficient accumulation of division operation outcomes between the subtraction and addition outputs during the guard period. Finally, we can reject the residual CMN by combining the subtraction and addition outputs.

휴대용 체지방계의 개발 (The Development of Portable Body Fat Meter)

  • 박종찬;임응춘;박수홍;한운동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.34-37
    • /
    • 2003
  • The purpose of this paper is the development of portable body fat meter. Bioelectrical impedance method for measuring human body composition is based upon the principle that the electrical conductivity of the fat mass is far greater than that of the fat. Finally measurement of percent body fat was made possible using a developed impedance measuring device which measure impedance between the thumb and ring finger.

  • PDF

양방향 제어를 이용한 가상환경에서의 팔운동감 제시 (Reproduction of Arm Kinesthetic Sense in Virtual Environment Using Bilateral Control)

  • 정웅철;민두기;송재복;김용일
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1999년도 추계학술대회 논문집
    • /
    • pp.97-100
    • /
    • 1999
  • Human feels kinesthetic sense in response to the force acted on him. In order to represent kinesthetic sense, a force is analyzed as mechanical impedance (i.e., stiffness or damping) and implemented by active impedance control. In this research, a 3-dimensional arm motion generator is developed to present various mechanical impedance characteristics to an operator. An introduction of virtual reality provides not only a visual effect in virtual environment but also the change in force synchronized with the visual effect in real time.

  • PDF

음향 매질의 추가질량 효과를 고려한 광음향 영상용 초소형 압전 기반 초음파 트랜스듀서의 개발 (Development of a Piezoelectric Micro-machined Ultrasonic Transducer for Photoacoustic Imaging that Accounts for the Added Mass Effect of the Acoustic Medium)

  • 안홍민;문원규
    • 센서학회지
    • /
    • 제29권1호
    • /
    • pp.33-39
    • /
    • 2020
  • Typically, photoacoustic images are obtained in water or gelatin because the impedance of these mediums is similar to that of the human body. However, these acoustic mediums can have an additional mass effect that changes the resonance frequency of the transducer. The acoustic radiation impedance in air is negligible because it is very small compared to that of the transducer. However, the high acoustic impedance of mediums such as the human body and water is quite large compared to that of air, making it difficult to ignore. Specifically, in a case where the equivalent mass is very small, such as with a micro-machined ultrasound transducer, the additional mass effects of the acoustic medium should be considered for an accurate resonance frequency design. In this study, a piezoelectric micro-machined ultrasonic transducer (pMUT) was designed to have a resonance frequency of 10 MHz in the acoustic medium of water, which has similar impedance as the human body. At that time, the resonance frequency of the pMUT in air was calculated at 15.2 MHz. When measuring the center displacement of the manufactured pMUT using a laser vibrometer, the resonance frequencies were measured as 14.3-15.1 MHz, which is consistent with the finite element method (FEM) simulation results. Finally, photoacoustic images of human hair samples were successfully obtained using the fabricated pMUT.