• 제목/요약/키워드: Human Body Information

검색결과 966건 처리시간 0.025초

한국 소방용 방화복에 대한 만족도 조사 (A Survey of Korean Firefighters Regarding their Satisfaction with Protective Clothing)

  • 한설아;남윤자;최영림
    • 복식
    • /
    • 제58권9호
    • /
    • pp.166-175
    • /
    • 2008
  • For the structural firefighting protective clothing, it can show a synergy effect when it satisfies smart fabric to block off a harmful environmental element and ergonomics design that apply range of motion of human body and appropriate size system. There are various standards about the structural firefighting protective clothing, but it's difficult to find a rule about movement suitability because the performance of the material holds a lot of the rules. Therefore, the purpose of this study is to propose a scheme to evaluate the current structural firefighting protective clothing and to improve movement suitability by research on the actual condition. For this, the survey about wearer acceptability scale on design and size and about improvement requirements was executed gathering firefighters' opinion. Questionnaire was composed with 23 items about satisfaction on current structural firefighting protective clothing, body suitability, movement suitability, improvement requirement and subjective information. As a results, Korean firefighters demand ergonomics design of structural firefighting protective clothing which to minimize restriction of body movement and to maximize body suitability.

침상의 인체감지를 위한 원격 스마트 제어 시스템에 관한 연구 (Study on Remote Smart Control System for Human Detection on Bed)

  • 박승환;심우정;정진택;김영서
    • 한국융합학회논문지
    • /
    • 제8권12호
    • /
    • pp.63-69
    • /
    • 2017
  • 본 연구는 침상의 인체 위치와 생체신호를 검출할 수 있는 스마트 침상제어시스템의 개발에 관한 것이다. 침상제어 시스템의 메인 제어보드는 인체 감지부, 모터 구동부, MCU로 구성된다. 여기서, 침상의 인체존재 확인의 신뢰성을 높이기 위해 맴브레인 센서에 의한 인체위치 검출부와 EMFI 센서의 생체신호 검출부를 인체감지부로 결합하였다. 또한 검출된 두 신호를 원격으로 앱 모드의 응용 프로그램에 연결하여, 침상위 인체정보를 모니터링할 수 있는 앱모드의 활용이 가능하도록 하였다. 본 연구에서 블루투스 통신에 의해 침상 인체 정보를 모니터링하는 원격 기능은 병원 및 요양기관의 낙상 및 침상부재사고 예방기법으로 활용될 수 있을 것이다.

Heart Rate Variability 신호의 시간 및 주파수 영역 분석 (Analysis of Heart Rate Variability Signals in Time-Domain and Frequency-Domain)

  • 길정수;권호열
    • 산업기술연구
    • /
    • 제22권B호
    • /
    • pp.163-167
    • /
    • 2002
  • Autonomic nervous system play an important role of keeping our health as balancing homeostasis. But the abnormality of these abilities makes our presence be feeble. To obtain these information of body which helps for us to decide whether one is healthy or not, based on the study of Heart Rate Variability. In this paper, we presented HRV model and its processing steps to extract some information of human body. After that, some experimental results are presented in time-domain and frequency-domain.

  • PDF

인체모형의 효과적 활용을 위한 자세 함수의 개발 (Development of a Postural Evaluation Function for Effective Use of an Ergonomic Human Model)

  • 박성준;김호
    • 대한산업공학회지
    • /
    • 제28권2호
    • /
    • pp.216-222
    • /
    • 2002
  • The ergonomic human model can be considered as a tool for the evaluation of ergonomic factors in vehicle design process. The proper anthropometric data on driver's postures are needed in order to apply a human model to vehicle design. Although studies on driver's posture have been carried out for the last few decades, there are still some problems for the posture data to be applied directly to the human model due to the lack of fitness because such studies were not carried out under the conditions for the human model application. In the traditional researches, the joint angles were evaluated by the categorized data, which are not appropriate for the human model application because it is so extensive that it can not explain the posture evaluation data in detail. And the human models require whole-body posture evaluation data rather than joint evaluation data. In this study a postural evaluation function was developed not by category data but by the concept of the loss function in quality engineering. The loss was defined as the discomfort in driver's posture and measured by the magnitude estimation technique in the experiment using a seating buck. Four loss functions for the each joint - knee, hip, shoulder, and elbow were developed and a whole-body postural evaluation function was constructed by the regression analysis using these loss functions as independent factors. The developed postural evaluation function shows a good prediction power for the driver's posture discomfort in validation test. It is expected that the driver's postural evaluation function based on the loss function can be used in the human model application to the vehicle design process.

Ergonomic Design of Necklace Type Wearable Device

  • Lee, Jinsil;Ban, Kimin;Choe, Jaeho;Jung, Eui S.
    • 대한인간공학회지
    • /
    • 제36권4호
    • /
    • pp.281-292
    • /
    • 2017
  • Objective: This study aims to identify important physical design variables in designing a necklace type wearable device, and to present design guidelines to maximize comfort that a user feels upon wearing the device. Background: Interests in fitness culture and personal health are on the rise recently. In such a situation, demand for necklace type wearable devices is projected to increase a lot, as the devices enable users to use their hands freely and to enjoy various contents through connection with mobile devices. However, the necklace type wearable device's comfort was assessed to have the lowest comfort in a running situation, where human body moves up and down and left and right more than other devices wearable on other human body parts. Therefore, the usability of a necklace type wearable device was low. In this regard, studies on identification of the variables affecting user comfort upon wearing a necklace type wearable device and on physical design direction maximizing comfort and usability are needed. Method: A pretest and a main test were carried out to draw the direction of necklace type wearable device design. In the pretest, wearing evaluation on the diverse types of devices released in the market was conducted to draw physical design variables of the devices affecting comfort. Furthermore, variables significantly affecting the comfort of a device were selected through an analysis of variance (ANOVA). In the main test, anthropometry was performed, and information on anthropometric items corresponding to the design variables selected in the pretest was acquired. Based on the pretest results and the anthropometric information in the main test, the present study produced design guidelines maximizing the comfort of a necklace type wearable device with regard to major design variables upon dynamic tasks. Results: According to the pretest results, the variables having effects on comfort were the angle of side points, width, and height. Due to interactions between variables, those need to be simultaneously considered upon designing a device. Upon dynamic tasks, the angle of side points and width of a device was designed to be smaller than mean angle of the trapezius muscle and neck width, and thus attachment to human body was high. As height was designed to be larger than mean neck front and rear point width, comfort was higher due to feeling of stability. Conclusion: Because user sensitivity to comfort was high at human body's inflection points, a device needs to be designed for users not to feel high pressure on specific body parts with the device fitting human body shape well. A design considering user's situation is also required in further studies.

A Multi-Stage Convolution Machine with Scaling and Dilation for Human Pose Estimation

  • Nie, Yali;Lee, Jaehwan;Yoon, Sook;Park, Dong Sun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권6호
    • /
    • pp.3182-3198
    • /
    • 2019
  • Vision-based Human Pose Estimation has been considered as one of challenging research subjects due to problems including confounding background clutter, diversity of human appearances and illumination changes in scenes. To tackle these problems, we propose to use a new multi-stage convolution machine for estimating human pose. To provide better heatmap prediction of body joints, the proposed machine repeatedly produces multiple predictions according to stages with receptive field large enough for learning the long-range spatial relationship. And stages are composed of various modules according to their strategic purposes. Pyramid stacking module and dilation module are used to handle problem of human pose at multiple scales. Their multi-scale information from different receptive fields are fused with concatenation, which can catch more contextual information from different features. And spatial and channel information of a given input are converted to gating factors by squeezing the feature maps to a single numeric value based on its importance in order to give each of the network channels different weights. Compared with other ConvNet-based architectures, we demonstrated that our proposed architecture achieved higher accuracy on experiments using standard benchmarks of LSP and MPII pose datasets.

모핑 기법을 활용한 40대 남성 하반신 가상모델 생성에 관한 연구 (A Study of 3D Virtual Fitting Model of Men's Lower Bodies in Forties by Morphing Technique.)

  • 박선미;남윤자;최경미
    • 한국의류학회지
    • /
    • 제31권3호
    • /
    • pp.463-474
    • /
    • 2007
  • With rapid expansion in e-retailing of apparel business, personalized fitting model service shows the possibility as the differentiated marketing strategy in cyber shopping. According as necessity of personalized fitting model construction rises, it is tried personalized fitting model creation in several fields such as computer engineering, mechanical engineering, information engineering. But, because existent study was concentrated only on human body modeling, it does not reflect average morphological characteristics of human body properly. In this study, we wish to examine if morphing is fit for expressing characteristic of average human body shape and suggest desirable morphing. We used 3-D scan data of 254 Korean middle aged men collected by Size Korea 2004. The result of this study are as follows: Lower body types were categorized by height hip girth and lower drop(hip girth-navel girth) which were main factors of lower body shape. Then each factor was divided into 3 groups respectively, 30% in the middle, over 30%, under 30%. In 27 groups, the group which belonged to 30% in the middle of height, 30% in the middle of hip girth, 30% in the middle of lower drop was selected as a representative group. We tested geometrical figure by differ volume, tilt, position of point. And we created a representative type of men's lower bodies by morphing the representative group and analyzed it's horizontal, vertical sections. A representative type which was created by morphing reflected a real body and changed realistically at the part of hip, crotch, calf muscle and so on. A cross sections of a representative type were similar to average cross sections of the representative group in size and shape. So it was proved that morphing was successful.

인간-컴퓨터 상호 작용을 위한 인간 팔의 3차원 자세 추정 - 기계요소 모델링 기법을 컴퓨터 비전에 적용 (3D Pose Estimation of a Human Arm for Human-Computer Interaction - Application of Mechanical Modeling Techniques to Computer Vision)

  • 한영모
    • 전자공학회논문지SC
    • /
    • 제42권4호
    • /
    • pp.11-18
    • /
    • 2005
  • 인간은 의사 표현을 위해 음성언어 뿐 아니라 몸짓 언어(body languages)를 많이 사용한다 이 몸짓 언어 중 대표적인 것은, 물론 손과 팔의 사용이다. 따라서 인간 팔의 운동 해석은 인간과 기계의 상호 작용(human-computer interaction)에 있어 매우 중요하다고 할 수 있다. 이러한 견지에서 본 논문에서는 다음과 같은 방법으로 컴퓨터비전을 이용한 인간팔의 3차원 자세 추정 방법을 제안하다. 먼저 팔의 운동이 대부분 회전 관절(revolute-joint)에 의해 이루어진다는 점에 착안하여, 컴퓨터 비전 시스템을 활용한 회전 관절의 3차원 운동 해석 기법을 제안한다. 이를 위해 회전 관절의 기구학적 모델링 기법(kinematic modeling techniques)과 컴퓨터 비전의 경사 투영 모델(perspective projection model)을 결합한다. 다음으로, 회전 관절의 3차원 운동해석 기법을 컴퓨터 비전을 이용한 인간 팔의 3차원 자세 추정 문제에 웅용한다. 그 기본 발상은 회전 관절의 3차원 운동 복원 알고리즘을 인간 팔의 각 관절에 순서 데로 적용하는 것이다. 본 알고리즘은 특히 유비쿼터스 컴퓨팅(ubiquitous computing)과 가상현실(virtual reality)를 위한 인간-컴퓨터 상호작용(human-computer interaction)이라는 응용을 목표로, 고수준의 정확도를 갖는 폐쇄구조 형태(closed-form)의 해를 구하는데 주력한다.

중년 여성용 3D 프린팅 토르소 더미를 사용한 시판 바디쉐이퍼 제품의 의복압 분석 (Analysis of Clothing Pressure of Commercial Body Shapers using 3D Printed Torso Dummy for Middle-aged Women)

  • 도월희;이정은
    • 한국의류산업학회지
    • /
    • 제23권6호
    • /
    • pp.810-825
    • /
    • 2021
  • This study measured and analyzed clothing pressure at each measurement part of commercial body shapers to provide basic information for product design and clothing pressure standard and level. This study used five body shaper. Clothing pressure measurements were taken at 18points: Anterior area 8points, lateral area 5points, posterior area 5points. The findings of this study were as follows. As a result of measuring the clothing pressure, the body shaper 1 showed the highest pressure, and body shaper 5 showed the lowest pressure at almost of the measurement points of the three body types. In some cases, body shapers 2, 3, and 4 showed different orders of pressure depending on the measurement point. The highest measured values in most body shapers were the P1 shoulder area and the P2 bust area. The lowest measurement area differed by body type, but mainly P3 underbust area, P4 thorax area and P9 axillary area, P11 waist lateral area, P13 hip lateral area. These body shapers showed different results depending on the the manufacturers and body type of middle-aged women, and because there was no standard for the pressure value. Therefore, it is necessary to design a body shaper sizing system after accurately setting the clothing pressure value for each body part of the consumer.