• 제목/요약/키워드: Housings

검색결과 297건 처리시간 0.027초

에어모터 하우징 양산용 다이캐스팅 금형의 불량과 대책에 관한 연구 (A study on the defects of die casting mold for air-motor housings and on problem-solving measures)

  • 김세환;최계광
    • Design & Manufacturing
    • /
    • 제6권1호
    • /
    • pp.18-23
    • /
    • 2012
  • HI-WORTH T-32, a non-powered plasma cutter, is a portable cutter that utilizes compressor-plasma inverter. With a special air-pressure piston, the cutter is semiautomatic. When they were produced by die casting dies, the bodies or housings of the cutter have defects about 100 percent of defect rate due to blisters and thermal deformation. Therefore, they are produced by mechanical machining, which leads to a hike in material and machining costs and to the loss of productivity. And companies are left with insignificant profit margins. Besides mechanical machining, this study proposes to modify defective mold and cut down defective rate and boost productivity.

  • PDF

제2차 신재생 기본계획과 태양열 보급목표 - 태양열 100만 호 달성 과연 가능한가 - (Solar Thermal Deployment During the 2nd Basic Renewable Period - The Prospect of Million Solar Roof Program : 2003-2012 in Korea -)

  • 김종선;박근성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.168-171
    • /
    • 2006
  • The Korean Solar Thermal Industry hopes to realize 1 Million Solar Thermal Roofs. According to the 2nd Renewable Basic Plan : 2003-2012 the Government showed a very aggressive Solar Thermal Deployment Plan including Solar Thermal Apartment Housings Program. Owing to the Vision Statement such as Million Solar Thermal Roofs Program Korean Solar thermal Industry also can bring another shinny days Especially the more solar thermal applications such as to the Apartment Housings and Green Villages could bring a sustainable Solar Society Korea The RPA Program by the 9 Major Non-Private Energy Corporal ions and the RPS Program for the Solar Thermal Energy shall be another useful policy for the realization of Million Solar Korea era.

  • PDF

Radiation Analysis of Communications and Broadcasting Satellite

  • Park, Jae-Woo;Chung, Tae-Jin;Lee, Seong-Pal;Seon, Jong-Ho;Jeong, Yun-Whang
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제3권2호
    • /
    • pp.40-45
    • /
    • 2002
  • A radiation analysis is performed for the Ka and Ku-band transponder of the Communications and Broadcasting Satellite (CBS) that is planned for launch into the geo-synchronous orbit. A particular attention is given to calculation of Total Ionizing Dose (TID) for the mission life time of 15 + 3 years. A numerical modeling of the charged particles at the geo-synchronous orbit is undertaken. The charged particles from the modeling are then transported through the mechanical structure and component housings of the transponder. A set of locations are selected for the detailed calculation of TID. The results from the present calculation show that three-dimensional modeling of the component housings as well as the mechanical structure of the spacecraft is requisite in order to acquire a reliable calculation of TID.

아파트 각 실의 비중변화와 내부공간 개조요구에 관한 연구 (A Study of the Changes of Areal Share of Rooms and Residents' Demand for Internal Space Remodeling of Apartment Housing)

  • 김한수;김재홍
    • 한국주거학회논문집
    • /
    • 제10권4호
    • /
    • pp.31-40
    • /
    • 1999
  • This study examines changes of internal structure and the ratios of room sizes of flat-type apartment housing and residents' demand of housing alteration. The main results are follows: First, the auxiliary space, such as multi-purpose room, storage & receiving space, becomes an important component of flat-type apartment housing. Second, apartment housings should be supplied to residents focusing on functions of space rather than the number of rooms. Third, the ratios of living room and storage space sizes have been increased as living space increases. Since the current apartment housings do not meet residents' needs, we suggest that residents' age, number of family, and economic status must be considered when apartment space are planned.

  • PDF

공동주택 지하주차장의 자연채광 실태 및 채광성능 평가 (Daylighting of Underground Parking Lots in Apartment Housings by Field Survey and Performance Evaluation)

  • 정유근;김정태
    • KIEAE Journal
    • /
    • 제2권2호
    • /
    • pp.39-44
    • /
    • 2002
  • Recently, underground spaces can be usually applied to the alternative of land use for parking. However, lack of window and natural light are among the most cited drawbacks associated with dark image of underground. If underground parking lots are designed to be positive and safe environment for people, openings for daylighting will play a significant role. The natural light and unobstructed view to outdoor are main elements to create optimal underground parking lots. This paper focuses on investigating the actual day lighting conditions and evaluating the day lighting performance of openings as potential lighting resources. For the study, the field measurements and Questionnaire surveys are conducted. And then, the day lighting performance of underground parking lots based on opening geometry and orientation are evaluated by scaled model experiments. As results, the feelings of safety and orientation of underground parking lots are improved by openings for day lighting regardless of the sizes. The required illuminances (daylight factor 0.5%) for underground parking lots can be satisfied in the skylight opening ratio of 4% or more.

중국 동북부 제민족의 주거형태 및 주생활 특성 (Housing and Living Pattern of the Five Tribes in Northeastern China)

  • 신수영;윤정숙
    • 한국주거학회논문집
    • /
    • 제15권6호
    • /
    • pp.47-56
    • /
    • 2004
  • In the North-eastern districts of China, Northern races inherited and developed their own cultural traditions. The housing of northeastern China has been changed under the influence of environment. Some tribes' housings has been developed, keeping their own peculiar style, while others have divested of their ethnic flavor. To understand these aspects of development, this study focused on the housings in Heilongjiang and Nei Monggol. As for the procedure, this study referred to the literature and carried out a field trip at the same time. The housing of northeastern China has undergone the process to fix their residence after the life of migration in common. In this process, northeastern hosing has changed variously and can be grouped into the several types by shape and material. From the point of view about living pattern, some important living features are extracted by the types.

국민주택 규모 아파트의 발코니 이용실태에 관한 연구 (A Study on the Actual Condition on the Utilization of Apartment Balcony in Economically Sized Housings)

  • 정미란;임소연;안옥희
    • 한국농촌생활과학회지
    • /
    • 제10권2호
    • /
    • pp.52-59
    • /
    • 1999
  • The purpose of this study is to find the current problems of using balcony in apartment. For this study, 255 subjects who are resided in economically sized apartment housings were selected. The major results of this study were ; 1) The front balcony was used as arrangement space a laundry drier and a flowerpot table. On the other hand, the rear balcony was used as storage space for a kind of washing powder and receptacle, kim-chi jar and storage container for food etc. 2) The most dissatisfactory respect on the balcony is the width of space. 3) The shelves were often used as storage facilities.

  • PDF

패시브 디자인을 적용한 주택의 기밀성에 관한 실측 사례 연구 (The measurement study on the airtightness of dwellings based on the passive design)

  • 이태구;윤두영
    • KIEAE Journal
    • /
    • 제13권2호
    • /
    • pp.13-20
    • /
    • 2013
  • Today, the world energy consumption in buildings occupies more than 30%. In our country, the energy consumption in buildings also occupies 25% of the entire national energy consumption. With the increasing demand of energy saving in architectural fields, there is a more interest in low-energy construction. For these low-energy housings, our country is planning to apply the energy-saving design standards at the level of passive houses in 2017. However, there is still a limitation in energy saving only with the standards on the performance of envelope in buildings. This means that unless a building is airtight even though it was well-insulated, cooling and heating energy consumption will increase due to the infiltration and leakage. Therefore, this study aims to make a comparative analysis of airtight performance by conducting a blower door test on the housings applied with passive designs, analyze the reasons why most houses fall short of the airtightness standards, and complement the airtightness problems in the inadequate parts of the buildings in order to save building energy.