• Title/Summary/Keyword: Housing damage

Search Result 167, Processing Time 0.029 seconds

Longitudinale Study on the Psychological Trauma of Victims of Housing Damage (주택파손 피해자의 심리적 충격 변화에 관한 추적조사 연구)

  • Son, Hee Joo;Choi, Yeol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.119-129
    • /
    • 2023
  • In many cases, trauma is overcome in a short periodtime, but for some, trauma results in long-term mental health issues such as in the form of post-traumatic stress disorder (PTSD). Natural disasters cause different types and extent of damage, meaning the degree of stress experienced also varies. In the case of damage to a house, the impact can be considerable. Therefore, this study examined the trauma experienced by households whose homes were damaged by natural disasters and to confirm the characteristics of psychological trauma. It was confirmed that traumas was greater when a house was damaged, compared with damage to other types of items. In addition, even in the case of trauma occurring, factors that affect the pattern of change to someone's mental state vary depending on the state's classification. And In addition, health services is significantly analyzed in all variables, and it was considered that the provision of basic services related to safety after a disaster is paramount. However, while psychological counseling has a positive effect on short-term traumas that manifests as anxiety and depression, it has an adverse effect on PTSD because of the depth and complexity of the suffering in PTSD, meaning the type of psychological support needs changing.

A Study on the Management of Precipitation for the Environmental Friendly Housing Complex -focused on the Contemporary Planning and Example Performed by Berlin- (주거단지의 친환경적 우수처리 실태에 관한 연구 -베를린의 현행 계획 및 사례를 중심으로-)

  • 이태구
    • Journal of the Korean housing association
    • /
    • v.11 no.2
    • /
    • pp.117-127
    • /
    • 2000
  • As urbanization proceeds and therefore impervious surface coverage increases, the amount of runoff goes up and the hydrological cycle is also changed. The surface retention and interception of precipitation in the urban area are reduced because the surface area is now slick and solid. Increasing runoff in building areas of the city causes flood damage, water pollution, reduction of ground water recharge, and the other environmental problems. This paper investigates various techniques of increasing rates in a site development performed by Berlin. The techniques offered in this paper improve sit water balance, and thus keep the site ecosystem much healthier.

  • PDF

Analysis of the Breakdown repair time of the Building Components in Public Rental-Housing Types (공공임대주택 유형별 부재의 사후보전 수선시기 설정연구)

  • Lee, KangHee;Ahn, YoungHan;Chae, ChangU
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.129-136
    • /
    • 2013
  • The rental housing has played a key role to supply a decent living space for the low-income households. The owner of the rental housing should maintain and manage the building physical condition. On the other hand, rents should use the housing without any damage and pay a certain fare for the rent. A rent is classified into two types : private and public. The public rent is mainly to supply a living space for non-available home owner with a low-rent fare. Many of public rent are built and supplied by the public institution or local government. The supplier would take a responsibility to maintain the building and components, reflected by the maintenance plan and repair scope. In this paper, it aimed at providing the repair time in building components of the public rental housing such as lighting, electrical cable, paintings and etc.. The repair time is analyzed with three calculation methods which are solved by the probability and empirical approach. Results are as follows : First, the repair time of the electrical facilities are maintained with 11yr, 10yr and 7 in permanent, public and redevelopment rent respectively. The roof proof has a repair time with 14yr, 11yr and 8 in permanent, public and redevelopment rent housing respectively. Second, Most of the components has a prior length of the repair time in permanent, public and redevelopment rent sequently. There is a difference in repair time according to the rental types. Therefore, it would continue to research the difference in aspect of the living style, building physics, living consciousness and etc.

Development and Evaluation of Potential Flood Damage Index for Public Facilities (공공시설물 잠재홍수피해지수 체계 개발 및 평가)

  • Kim, Gilho;Baeck, Seung Hyub;Jung, Younghun;Kim, Kyungtak
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.4
    • /
    • pp.97-106
    • /
    • 2016
  • Since public facilities have high property values and are directly exposed to the flood hazard, they account for the highest share of disaster damages compared to other assets such as housing, industry, vehicle and agriculture in case of floods. Therefore, this study was conducted to develop and suggest the potential flood damage index for public facilities to evaluate potential flood damage of specific local government directly or indirectly as a tool for decision-making related to flood prevention, maintenance, management, and budget allocation. The flood damage assessment system proposed in this study was evaluated in 231 local governments nationwide. Evaluation results showed that higher values were obtained in Seoul metropolitan government, Gyeonggi-do (province), coastal areas in Gyeongsangnam-do (province), and Jeju island.

A Study on Sowhajang's Present Condition and Plan Transformation Characteristics (소화장(昭和莊)의 현황과 평면변용 특성 연구)

  • Jung, Mi-Jung;Yoo, Jae-Woo;Chang, You-Kyoung
    • Journal of the Korean housing association
    • /
    • v.22 no.3
    • /
    • pp.123-134
    • /
    • 2011
  • 'Sohawjang' is the first apartment house built in Busan the modern period, 1944. 'Sohawjang' needs to be apprised its value as an very important object of study with architectural and dwelling historic meaning because multi-family houses built in Japanese Rule Era that now exist in Korea are very rare. Thus, this study attempted to leave records to archive by conducting face to face interviews and surveying on 'Sohawjang' which is seriously in danger of extinction and its original form damage as the first step. Especially, around Korea's Liberation, this study tried to extract transformation characteristics of residential space and cultural differences appeared on differences of occupants having different nationality. Through these results, this study attempted to examine the era of apartment house and transformation characteristics and values of modern dwelling historic dimension according to changes of users appeared in Busan modern period. Through this study, it offers basic data about introduction and transition processes of an apartment house in Korea. It has an meaning of suggestion reference data for original form preservations or regenerations.

The Causes and Countermeasures for failures of Distribution Polymer Surge Arresters (배전용 폴리머 피뢰기의 고장원인 및 대책)

  • Kim, Ju-Yong;Lee, Jae-Bong;Kim, Dong-Myung;Jang, Sang-Ok;Hwang, Gwang-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1159-1162
    • /
    • 2003
  • Recently we suffered lot of failures of polymer surge arresters made by same manufacture after one year field operation. In order to set up countermeasures we investigated the causes of failures. We extracted faulted arresters and sound ones which were installed in same pole with faulted ones for the electrical test and dissection. 44 arresters were removed from 8 branch offices. Almost all of faulted arresters hadtracking damage on the interface between inner module and housing and the surface of inner module was very rough and irregular. It was possible to occur moisture ingress into the interface between inner module and housing due to the void of the interface and non tight sealing caps. Lots of sound arresters were failed during the moisture ingress test. This result must relate with tracking damage of faulted arresters. Therefore we can say that arresters had poor interface and sealing system. But we could not found aging and defects of ZnO elements because the electrical performance except moisture ingress test of arresters showed good.

  • PDF

A Study on Improvement of Relief System in Disaster (재해구호시스템 개선에 관한 연구)

  • Park, Dae-woo
    • Journal of the Society of Disaster Information
    • /
    • v.3 no.2
    • /
    • pp.39-53
    • /
    • 2007
  • In modern society, the natural disaster damage is increasing by unusual weather conditions such as global warming. Many disaster victims in the disaster spot suffered from the heavy damages. In these conditions, this paper aims to improve of relief system in disaster. To achieve our aims, we analyzed the present disaster relief system in a legal, institutional aspect and disaster relief on the conceptual content, and look at the contents of the damage I have seen. And we are look at the issue of disaster relief, disaster relief measures to improve the present. In conclusion, this research suggests the improvements of the disaster relief system. First, Donations to secure transparency of the scheme passes. Second, the reality of actual expenses paid farmland. Third, recovery estimate by the reality. Fourth, when the disaster occurred, and the disaster of the itemized information. Finally, the degree of damage to the housing relief material support systems need improvement.

  • PDF

Effects of Tsunami and Disaster Response System (뉴스초점 - 지진해일의 영향과 방재대책)

  • Kang, Young-Seung
    • Journal of the Korean Professional Engineers Association
    • /
    • v.45 no.1
    • /
    • pp.45-48
    • /
    • 2012
  • The 2011 Japan Tsunami caused tremendous damage to coastal areas. Because of their drastic propagation speed and large run-up height, nearshore tsunami can cause catastrophic damages on coastal communities within a short time. It is necessary to establish the tsunami hazard mitigation to reduce human injury housing damage. The construction of Tsunami warning system and production of hazard map are needed for minimizing damage by tsunami.

  • PDF

A Study on the Change Characteristics of the Kookmin Housing Complex in Suyu 1-dong, Seoul (서울시 수유1동 국민주택단지의 변화특성에 관한 연구)

  • Lee, Seong-Woon;Kim, Kyuong-Yon;Jun, Byung-Kweon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.5
    • /
    • pp.21-28
    • /
    • 2018
  • This study analyzed the physical characteristics and change characteristics of urban detached residential area. In the reality of South Korea in which the history of modern urbanization is not long, the densification that progressed together with sudden population growth without any consideration of city plans became to reveal many problems. Thereafter, apartment-centered large scaled development plans have been implemented until now as an alternative for the foregoing. As the residential environments of old downtown areas that were excluded from the development have been gradually deteriorated, large scaled re-development and reconstruction projects have been adopted as ways to solve the problems of the old downtown areas. On one hand, the development methods that damage the history of the detached housing areas have been resisted. With such a background, this study attempted the analysis of the change characteristics of the Kookmin Housing Complex in Suyu 1-dong, Seoul with a view to playing the role of evidentiary materials for the disappearing urban detached housing areas or those urban detached housing areas that may be revived. This author hopes and the results of this study will lead to careful development that presents measures to maintain and develop modern urban residential areas where the history of past residential areas and culture are disappearing due to full-scale redevelopment.

A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type (하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.