• Title/Summary/Keyword: Housing damage

Search Result 165, Processing Time 0.031 seconds

Investigation on Electrochemical Characteristics of Battery Housing Material for Electric Vehicles in Solution Simulating an Acid Rain Environment with Chloride Concentrations (산성비 환경을 모사한 수용액에서 염화물 농도에 따른 전기자동차 배터리 하우징용 재료의 전기화학적 특성 연구)

  • Shin, Dong-Ho;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.147-157
    • /
    • 2022
  • Electrochemical characteristics and damage behavior of 6061-T6 aluminum alloy used as a battery housing material for electric vehicles were investigated in solution simulating the acid rain environment with chloride concentrations. Potentiodynamic polarization test was performed to analyze electrochemical characteristics. Damage behavior was analyzed through Tafel analysis, measurement of damage area, weight loss, and surface observation. Results described that corrosion current density was increased rapidly when chloride concentration excceded 600 PPM, and it was increased about 7.7 times in the case of 1000 PPM compared with 0 PPM. Potentiodynamic polarization experiment revealed that corrosion damage area and mass loss of specimen increased with chloride concentrations. When chloride concentration was further increased, the corrosion damage area extended to the entire surface. To determine damage tendency of pitting corrosion according to chloride concentration, the ratio of damage depth to width was calculated. It was found that the damage tendency decreased with chloride concentrations. Thus, 6061-T6 aluminum alloy damage becomes larger in the width direction than in the depth direction when a small amount of chloride is contained in an acid rain environment.

A Study on Module Design and Performance of Polymer Arrester (폴리머 피뢰기의 모듈 설계 및 성능에 관한 연구)

  • Cho, Han-Goo;Chun, Jong-Uk;Kang, Yeong-Kil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.108-111
    • /
    • 2003
  • The main objective of this paper is to module design and pressure relief test a new type of polymer gapless surge arrester for power distribution line. Metal oxide surge arrester for most electric power system applications, power distribution line and electric train are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of gapless elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion.

  • PDF

Relief Performance of Fault Current and Design/Manufacturing of Polymer Arresters for Power Distribution (배전선로용 폴리머 피뢰기의 모듈 설계/제조 및 성능)

  • Cho, Han-Goo;Yun, Han-Su;Jang, Tae-Bong;Chie, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.175-179
    • /
    • 2005
  • The main objective of this paper is to module design and pressure relief test a new type of polymer gapless surge arrester for power distribution line. Metal oxide surge arrester for most electric power system applications, power distribution line and electric train are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of gapless elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion.

  • PDF

Assessment of the level and identification of airborne molds by the type of water damage in housing in Korea (국내 주택에서 물 피해 유형에 따른 부유곰팡이 농도 수준 평가 및 동정 분석)

  • Lee, Ju Yeong;Hwang, Eun Seol;Lee, Jeong-Sub;Kwon, Myunghee;Chung, Hyen Mi;Seo, SungChul
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.355-361
    • /
    • 2018
  • Mold grows more easily when humidity is higher in indoor spaces, and as such is found more often on wetted areas in housing such as walls, toilets, kitchens, and poorly managed spaces. However, there have been few studies that have specifically assessed the level of mold in the indoor spaces of water-damaged housing in the Republic of Korea. We investigated the levels of airborne mold according to the characteristics of water damage types and explored the correlation between the distribution of mold genera and the characteristics of households. Samplings were performed from January 2016 to June 2018 in 97 housing units with water leakage or condensation, or a history of flooding, and in 61 general housing units in the metropolitan and Busan area, respectively. Airborne mold was collected on MEA (Malt extract agar) at flow rate of 100 L/min for 1 min. After collection, the samples were incubated at $25^{\circ}C$ for 120 hours. The cultured samples were counted and corrected using a positive hole conversion table. The samples were then analyzed by single colony culture, DNA extraction, gene amplification, and sequencing. By type of housing, concentrations of airborne mold were highest in flooded housing, followed by water-leaked or highly condensed housings, and then general housing. In more than 50% of water-damaged housing, the level of airborne mold exceeded the guideline of Korea's Ministry of Environment ($500CFU/m^3$). Of particular concern was the fact that the I/O ratio of water-damaged housing was greater than 1, which could indicate that mold damage may occur indoors. The distribution patterns of the fungal species were as follows: Penicillium spp., Cladosporium spp. (14%), Aspergillus spp. (13%) and Alternaria spp. (3%), but significant differences of their levels in indoor spaces were not found. Our findings indicate that high levels of mold damage were found in housing with water damage, and Aspergillus flavus and Penicillium brevicompactum were more dominant in housing with high water activity. Comprehensive management of flooded or water-damaged housing is necessary to reduce fungal exposure.

Fatigue Damage Analysis of the Caliper Housing under ABS Mode (ABS 작동에 의한 캘리퍼하우징에 미치는 피로손상평가)

  • 김정엽;모종운
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.4
    • /
    • pp.156-163
    • /
    • 1996
  • The brakes are the most important safety-critical accident avoidance components of a motor vehicle. They must perform safely under a variety of operating conditions and must have enough strength not to fail during the life of a vehicle. Recently, anti-lock brake systems are used on more and more passenger cars. The ABS brakes modulate brake line pressure to prevent brakes from locking during braking. In this study, finite element analysis, material test for FCD45, measurement of stress and cumulative fatigue damage analysis were performed to evaluate fatigue damage of the caliper housing under ABS mode.

  • PDF

A Study of renovation for the cultural resourceful utilization of traditional high-class housing designated as a cultural property - Focusing n the No.27 National Folklore Resource Kongdukguiga - (문화재 지정 전통 상류주택의 문화자원적 활용을 위한 전시기념관으로의 리노베이션 계획 연구 - 민속자료 27호 공덕귀가를중심으로 -)

  • 안주영;최상헌
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 1999.04a
    • /
    • pp.118-121
    • /
    • 1999
  • Traditional housing must be conserved simultaneously with not only the building itself, but the circumstances of the surroundings. Hence, traditional housing should be developed as a product of a culture environment. However, most cultural properties have recently been treated as only a piece of property by irresponsible maintenance practices and damage placed on private traditional housing. Apparently, it has not always been a result of dweller's negligence. Thus, various policies must be needed to effectively preserve traditional housing. To do so, this study will indicate a new direction for the circumstance of preservation through cultural employment of traditional high-class housing as well as reduce maintenance and damage for dweller's convenience. Furthermore, this study will propose a renovation for popularization of Korean cultural assets through the gradual implementation of both economic value and public worth.

  • PDF

Effects of Changing in Wind Environment of Typhoon Approaching to a Building (태풍 접근에 의한 바람 환경 변화가 건물에 미치는 영향)

  • Park, Jong-Kil;Jung, Woo-Sik;Choi, Hyoj-In
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.561-564
    • /
    • 2009
  • In order to reduce damage from natural disasters, prevention activities through analysis and predicting based on meteorological factor and damage data is required. Other countries already have continuously studied on natural disasters and developed reducing disasters damage. But the risk assessment model for natural disaster is not to Korea. Therefore, a previous model of hurricane, Florida Public Hurricane Loss Model(FPHLM), is the basis and is applying to domestic situation. Accordingly, this study introduces the variables selecting process because input variables should be selected under Korea present state and be used. The estimating representative damage method would be necessary along with selecting housing types representing relevant areas because estimating damage amount of all over relevant areas housing was very hard during damage estimating process. But there is no exact representative housing types in the Korea. Therefore, we select housing types applicable to risk assessment model for natural disasters representing the Korea through previous studies and literature reviews. We using ASCE 7-98(Minimum Design Loads for Buildings and Other Structures, 1998) standard which estimated wind load using 3-second gust. ASCE 7-98 divided Main Wind Force Resistance System(MWFRS) and Component and Cladding(C&C) and it estimated wind load. Therefore, we estimate wind load affected by 3-second gust of a typhoon Maemi through calculating wind load process using selected representative detached house types in the process of selecting input variables for previous disaster predict model. The result of houses damage amount is about 230 hundred million won. This values are limit the 1-story detached dwelling, 19~29pyeong(62.81~95.56 $m^2$) of total area and flat roof. Therefore, this process is possible application to other type houses.

  • PDF

A study of renovation for the cultural resourceful utilization of building designated as the cultural properties - Focusing on the No. 27 Folklore Materials Angukdongyounboseonga- (문화재 지정 건축물의 문화자원적 활용을 위한 리노베이션 계획 연구 - 시도민속자료 27호 안국동윤보선가를 중심으로 -)

  • 안주영;최상헌
    • Korean Institute of Interior Design Journal
    • /
    • no.29
    • /
    • pp.58-66
    • /
    • 2001
  • Traditional housing must be conserved simultaneous1y with not only the building itself, but the circumstances of the surroundings. Hence, traditional housing should be developed as a product of a culture environment. However, most cultural properties have recently been treated as only a piece of property by irresponsible maintenance practices and damage placed on private traditional housing. Apparently, it has not always been a result of dweller's negligence. Thus, various policies must be needed to effectively preserve traditional housing. To do so, this study will indicate a new direction for the circumstance of preservation through cultural employment of traditional high-class housing as well as reduce maintenance and damage for dweller's convenience. Furthermore, this study will propose a renovation for popularization of Korean cultural assets through the gradual implementation of both economic vague and public worth.

  • PDF

Module Design and Performance Evaluation of Surge Arrester for Loading In Railway Rolling Stock (전철 탑재형 피뢰기의 모듈설계 및 성능평가기술)

  • Cho, H.G.;Kim, S.S.;Han, S.W.;Lee, U.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2038-2040
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and subway are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrestor and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise. etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

Recognition and Reading Experience of the Rental Housing Law in Rental Housing Residents (임대주택 입주자의 임대주택법대 대한 인식 및 읽은 경험 분석)

  • 김숙향
    • Journal of the Korean Home Economics Association
    • /
    • v.40 no.7
    • /
    • pp.41-52
    • /
    • 2002
  • The purpose of this study was to examine the degree of recognition and reading experience of the rental housing law in rental housing residents. The subjects of this study were 359 residents who lived in Gwang-Ju and who were surveyed by questionnaire in 2000. Data was analyzed with the statistical methods of frequency, percentage, mean and chi-square. The main results of this study were as follows: 1) About 64% of the residents knew the rental housing law 2) Degree of recognition about the rental housing law was significant on age, apartment size, housing rental deposit, and monthly rental fee. 3) About 92% of the residents didn't read the rental housing law. 4) Degree of reading about the rental housing law was not significant on the level of housing characteristics. If the residents knew about rental housing law, it might be prevented the damage from housing rental deposit refund debate, contract termination and rental housing company dishonor.