• Title/Summary/Keyword: Housing Performance

Search Result 875, Processing Time 0.024 seconds

Shear performance of green timber wall panels (그린팀버월 패널의 전단성능)

  • Kim, Yun-Hui;Shin, Il-Joong;Jang, Sang-Sik
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.541-547
    • /
    • 2011
  • Korean building industry was developed by concrete and steel construction. However, concrete and steel have some problems which low carbon storage capability and difficulty of recycling. According to many studies, timber has high carbon storage capability, high recycling capability and sustainable supporting capability. Focus on this factors of timber, make new wall structure as Green Timber Wall panels and check the shear performance to use wall system in housing construction such as light-weight timber construction and nondearing wall on other construction. In the results, B-4-B and B-4-S show similar modulus of shear stiffness on the table. GH-4-GH has slip shape failure mode between Green Timber Wall boards. GH-4-GV has most stable characteristic curve than other specimens.

Performance Evaluation of a Lubrication Seal for Freight Cars (화물열차 차축용 저 마찰 오일실의 성능 평가)

  • Kim, Jae-Hoon;Shin, Kong-Soon;Kim, Jun-Ho;Goo, Byeong-Choon
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.6 s.37
    • /
    • pp.630-634
    • /
    • 2006
  • Rail car axles are very important parts for safety of passengers and structural integrity of vehicles. The axles are supported by bearings. To seal grease lubricating the bearings of freight cars, an oil seal has been developed. The developed oil seal is composed of an inner plate, an outer plate and a seal rubber. The friction between axle and housing with the developed oil seal is very low. The seals are designed for a minimum life expectancy of 800,000 kilometers service. In this study, an accelerated durability tests according to AAR Specification M-934-82 were carried out. In addition, various performance tests according to KS B 2804 were conducted.

Insulation Performance Evaluation of Apartment Housing Bying a Three-Dimensional Steady State Simulation (3차원 정상상태 해석에 의한 공동주택 단열성능 평가 - TDR(온도상대비)을 중심으로 -)

  • Choi, Bo-Hye;Choi, Gyoung-Seok;Kang, Jae-Sik;Lee, Seung-Eon;Lee, Yong-Jun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.730-735
    • /
    • 2009
  • The purpose of this study is to consider improvement performance to prevent condensation and draw the optimum insulation design method for building using simulation tool. In this study, the three corners, weak part in condensation, were conducted by three-dimensional steady state simulation. From the results, it is required to strengthen insulation design, and it is founded that existing insulation system typically applied to most Korean apartment buildings has serious insulation defect that insulation is disconnected by structural components at the joints of wall-slab and wall-wall in envelope. So, it is considerate to need a concrete technology improvement.

  • PDF

A study for noise properties of Sirroco fan blades (시로코팬 블레이드의 소음특성연구)

  • 최한림;곽지호;송기선;이덕주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.257-263
    • /
    • 2001
  • The purpose of this study is to find the amount of contributions of each Sirroco fan parameter to noise and performance using experimental and numerical approaches. We made several fans and structures related to fan housing and fan for parameter study like inlet blade angle, outlet blade angle, inlet diameter, outlet diameter, blade shape. etc.. Numerical analysis was performed using commercial code (FANNOISE) for the part not to be possible to do experiment. Using these parameter study, We have found the way to reduce noise and improve performance of fan and had some useful data for designing low noise and high performance fan.

  • PDF

An Experimental Study on Performance and Flow Characteristics of Automotive Sirocco Fan (자동차용 시로코팬의 성능 및 유동특성에 관한 실험적 연구)

  • 유성연;이대웅
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.954-963
    • /
    • 2002
  • For the optimal design of an automotive blower system, effects of the scroll cut-off starting angle, the clearance between blade tip and bellmouth, and the scroll expansion angle on the performance of sirocco fan are investigated experimentally. Best performance is achieved at fan exposure ratio $\Deltae/r_c$,/TEX> =1.0, and clearance ratio $\DeltaeC/C=0.62. Flow characteristics inside sirocco fan are also studied by using LDV. Flow patterns in the inside of fan can be classified into three regions. Velocity vector has the same direction as rotational direction of fan at 0~$120^{\circ}$, toward the fan blades at 150~$180^{\circ}$, and opposite direction at 210~$330^{\circ}$. Turbulent intensity is relatively high near the cut-off edge in the scroll housing.

Performance Evaluation of Water Vapour Adsorption & Desorption Properties of Low-Priced Generic Ceramic Panel Materials for Humidity Control - Focuses on analyzed measurements of temperature and humidity obtained from the housing units - (저가보급형 습도조절용 세라믹패널의 조습성능 평가 - 리빙랩 온·습도 모니터링 분석을 통한 실측결과를 중심으로 -)

  • Jang, Kun-Young;Ryu, Dong-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.39-40
    • /
    • 2017
  • This study aims to evaluate the humidity control performance of low-priced generic ceramic panels that are used to control humidity. Temperature and humidity are monitored by using 'Living Lab' and the change of indoor relative humidity is measured and analyzed. According to the results of the study, the indoor relative humidity of rooms installed with ceramic panels was found to be low compared to that of living rooms by 2.2%RH (test period) and 3.2%RH (daily). In the case of maximum relative humidity, rooms installed with ceramic panels were found to be low by 6.9%RH. The results are attributable to the humidity absorption of ceramic panels. Accordingly, future ceramic panels need the improvement of performance and an appropriate construction area should be derived depending on indoor space.

  • PDF

Consumer Attitude and Satisfaction with Well-being Products: A Focus on the Expectation-disconfirmation Paradigm (소비자의 웰빙태도 및 웰빙상품에 대한 만족도 : 기대-불일치 패러다임을 중심으로)

  • Nam, Su-Jung;Yoo, Hyun-Jung
    • Journal of the Korean Home Economics Association
    • /
    • v.45 no.5
    • /
    • pp.1-13
    • /
    • 2007
  • The purpose of this study was to explore the well-being attitude and use the expectation-disconfirmation model to assess consumer satisfaction with well-being products. The consumer expectations, performance and disconfirmation scales were composed of 7 items of 5-likert scales. Consumer satisfaction with well-being products was measured with one-item-measurement scale. The results of this study are as follows. 1. The well-being attitude consists of 4 factors. : consumption of the well-being products, pursuit of mental well-being, criticism of commercial fashion, and pursuit of harmony with natural life. 2. Well-being attitude influences the consumers' expectation, performance, and satisfaction with well-being products. 3. Consumer expectation for well-being products has no influence on satisfaction, but performance and disconfirmation have a high degree of influence on satisfaction.

Retrofit Production and Field Evaluation for Use of Safeguards Equipment in Extreme Temperature Environments (극한 온도환경에서의 안전조치 검증장비 사용을 위한 리트로핏 제작 및 현장 평가)

  • Heekyun Baek;Jinwon Lee;Jung-Ki Shin
    • Journal of Radiation Industry
    • /
    • v.18 no.1
    • /
    • pp.79-87
    • /
    • 2024
  • In a previous study, the suitability for use of inspection equipment was evaluated at temperatures outside the quality assurance range. The quality assurance operating temperature of the safeguards equipment is 0~+40℃, and previous studies have confirmed the performance of the safeguards equipment for temperatures ranging from -40~+70℃. The scintillator-based verification equipment showed a shift in the centroid channel and a change in the count rate in all temperature ranges, and the semiconductor-based safeguards equipment generated Leakage Current and equipment failure. In this study, a retrofit was performed applying a vacuum housing to the safeguards equipment (Inspector-2000-based inspection equipment), and performance evaluation was performed at a low temperature and snowy site, and it was confirmed that the same performance was observed as the measurement results at room temperature.

A Study of Measurement on Airtightness and Air-Flow Performance of Apartment Housing Adopting Window Frame-Type Natural Ventilation (자연환기장치가 적용된 공동주택의 기밀 및 공기유동 성능 실측 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Kim, Sun-Dong
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.325-332
    • /
    • 2014
  • The purpose of this study was to measure the airtightness and Air-Flow Performance for 7th house of small apartment houses adopted window frame-type natural ventilation. All window and living room door is provide with window frame-type natural ventilation, and there is provide with manual controller. As the object of measurement, the 6th type small apartment houses with area of $33m^2$ to $51m^2$ was selected. airtightness performance was measured at the front door using Blower door system. We measured ventilation rate per hour on 50Pa pressure different between inside and outside by the 1st to 6th cases. As a result, when the natural ventilation frame was closed, average amounts are shown as the ventilation rate per hour were 2.27ACH (CASE1). and the result is similar to general apartment house (1.65~4.28ACH). When the natural ventilation frame was open, average amounts are shown as the ventilation rate per hour were 5.87ACH (CASE6). In addition, that's a 3.6ACH increased more than CASE1.

Business ethics education, employee perceptions of corporate business ethics, and organizational performance of apparel companies

  • Kim, Soo-Kyung;Yoh, Eunah;Shin, Eonyou
    • The Research Journal of the Costume Culture
    • /
    • v.30 no.3
    • /
    • pp.477-493
    • /
    • 2022
  • The purpose of this study is to explore relationships between company's characteristics, the status of business ethics education, employee perceptions of corporate business ethics, and organizational performance. A total of 161 small- and medium-sized apparel companies participated in a survey and data was analyzed using cross-tabulation, ANOVA, and SPSS PROCESS. The results show that, larger companies involved with export are more likely to implement business ethics education, whereas no company characteristic is associated with perceptions of corporate business ethics. Furthermore, apparel companies that implemented or planned to implement business ethics education, have employees with more positive perceptions of corporate business ethics and better organizational performance than fashion companies that have no plan to implement such education. In addition, companies in the apparel sector with higher employee perceptions of corporate business ethics had greater organizational performance than apparel companies with lower employee perceptions of corporate business ethics. This study emphasizes the need to implement business ethics education to enhance employee perceptions of company business ethics, which in turn promotes organizational performance. It is expected that the results of this study will positively affect the development and expansion of business ethics education programs and contribute to the foundation of knowledge for business ethics education for fashion companies.