• Title/Summary/Keyword: Housing Performance

Search Result 875, Processing Time 0.031 seconds

Evaluation of Lateral Load Resistance and Heating/Cooling/Lighting Energy Performance of a Post-disaster Refugees Housing Using Lightweight composite Panels (경량 복합패널을 활용한 구호주거의 횡하중 저항성능 및 냉난방조명 에너지성능 평가)

  • Hwang, Moon-Young;Lee, Byung-Yun;Kang, Su-Min;Kim, Sung-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.252-262
    • /
    • 2019
  • Following the earthquake in Gyeongju (2016) and Pohang (2017), South Korea is no longer a safe place for earthquakes. Accordingly, the need for shelters suitable for disaster environments is increasing. In this study, a lightweight composite panel was used to produce post-disaster housing for refugees to compensate for the disadvantages of existing evacuation facilities. For this purpose, an evaluation of structural performance and thermal environment for post-disaster housing for refugees composed of lightweight composite panels was performed. To assess the structural performance, a lateral loading test was conducted on a system made of lightweight composite panels. The specimens consisted of two types, which differed according to the bonding method, as a variable. In addition, the seismic and wind loads were calculated in accordance with KBC 2016 and compared with the experimental results. Regarding the energy performance, optimization of south-facing window planning and window-wall ratio and solar heat gain coefficient were analyzed to minimize heating, cooling, and lighting energy. As a result, the specimens composed of lightweight composite panels will perform sufficiently safely for lateral loads and the optimized window planning will lead to a low-energy operation.

A Study on the Development of Rolled Dry Floor Heating System for Improving Workability (현장 시공성 개선을 위한 롤타입 건식바닥난방시스템 개발)

  • Lee, Gyu-Dong;Kim, Jun-Ho;Jeong, Chang-Ho;Kim, Dong-Woo;Ogawa, Keiichiro
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.177-180
    • /
    • 2012
  • Korea residential housing generally use wet floor heating system 'Ondol' which consist of insulation cushioning, lightweight foamed concrete, hot water pipe and mortar on top of reinforced concrete slab. Wet floor heating system's installation process is too complicate and difficult to supervise field for continuing assurance quality. Also, this method has a huge impact on the progress of construction because it take a long time to cure finishing mortar and lightweight foamed concrete. Therefore, it is considered a disturbance factor of reduction of construction duration for enhancing competitiveness. In this study, we conducted an experiment about the radiant heat performance and temperature difference on upper panel of rolled dry floor heating systems which is jointly developed by Kolon global and Sumisho Metalex for remodeling housing, studio apartment and the urban-life housing.

  • PDF

Development of Environmental Control Systems for Windowless Pig-housing (I) - Assessment of Control Performance - (무창돈사의 환경제어 시스템 개발 (I) - 제어성능의 평가 -)

  • 장홍희;장동일;임영일
    • Journal of Biosystems Engineering
    • /
    • v.24 no.5
    • /
    • pp.415-424
    • /
    • 1999
  • This study was conducted to assess performances of the developed environmental control systems under various seasons of Korea. In all trials for the environmental control systems, the manure pit ventilation system in the windowless pig-housing with partly slatted floor was used. Consequently, under all seasons of Korea, the complex environmental control systems could comfortably maintain the indoor temperature (14.8~27.2$^{\circ}C$) , concentrations of noxious gases (CO2 gas : 631~1,874ppm, NH3 gas : 0.3~3.2ppm), air velocity (0.11~0.23m/s), air movement, and so on. Therefore, the performances of the complex environmental control systems were evaluated as proper as the intended.

  • PDF

Development of a Measurement System for Ammonia Gas in Swine Housing (돈사내 암모니아가스 계측시스템 개발)

  • 방승훈;장동일;장홍희;임영일
    • Journal of Biosystems Engineering
    • /
    • v.23 no.4
    • /
    • pp.359-364
    • /
    • 1998
  • A PC based measurement system was developed and it consisted of ammonia sensor(TS-1000), AMP & MUX Board, A/D Converter, and personal computer. The results obtained from the study are summarized as follows : 1. The relationship of outputs(V) of ammonia sensor(AS) and concentrations(ppm) of ammonia gas was analyzed by the linear regression analysis and the output values were very accurate when compared with standard ammonia gas. 2. The test results showed that the performance of ammonia gas sensor was not 31B3c1e4 by temperatures and humidities 3. The developed ammonia gas measurement system was proved to be practically uesful for measuring concentrations of ammonia gas in pig housing.

  • PDF

Development of Polymer Bushing for Overhead Line Switch (가공개폐기용 폴리머 부싱 개발)

  • 최경선;주종민;이철호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.787-790
    • /
    • 2001
  • Polymer bushing used for overhead line switch was designed and investigated. Requirements of electrical ratings such as partial discharge, ac withstand voltage, impulse voltage and material properties were proposed in accordance with IEEE 386 and pre-standard (PS) 151-146∼147, 170∼180 of KEPCO. The polymer bushing consists of an internal epoxy bushing and external housing made of EPDM rubber. The rubber housing was molded with mold cone. Therefore, the polymer bushing offers several advantages like light weight, good sealing properties, easy installation and excellent performance in contamination. Electric field analysis was also introduced in order to verify the reliability of the design.

  • PDF

A Numerical Analysis of the Elastohydrodynamic Lubrication of Connecting Rod Bearings (커넥팅 로드 베어링의 EHL에 관한 수치해석)

  • 김병직;김경웅
    • Tribology and Lubricants
    • /
    • v.12 no.3
    • /
    • pp.63-71
    • /
    • 1996
  • The connecting rod bearing, which is subjected to periodical dynamic loading, is an impoRant component of the reciprocating engine. In the operation of this bearing, significant parameters are the oil film thickness and the film pressure. Peak film pressures of 20-30 MPa are not uncommon. So the elastic deformation of the bearing housing can have a significant effect on the bearing performance. In this study, a numerical analysis of connecting rod bearing is investigated. Elastic deformation of the bearing housing is considered in the analysis. Separate hydrodynamic and structural analysis are coupled through a direct iterative process. It is shown that as the result of the elastic deformation of the bearing housing, the eccentricity ratio is increased, and the minimum value of the minimum film thickness and the maximum value of the maximum film pressure are decreased. The variations of rotational speed and cylinder pressure affect the minimum film thickness and the maximum film pressure variations of the connecting rod bearing.

Post Evaluation on the Constructibility of the Lightweight Wall in Long Life Housing through Interview Survey (설문조사를 통한 장수명주택의 경량벽체 시공성 사후평가)

  • Lee, Hak-Ju
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.188-189
    • /
    • 2014
  • Recently, structural system of apartment building is changing from wall type to column type to accommodate various life styles of residents in Korea. Reinforced-concrete bearing wall structures have been mainly used in apartment construction since 1980's. It is impossible to remove the bearing wall in case of remodeling a house, so that the lightweight wall is needed to apply to the column type structure of the Long Life Housing. Therefore, the purpose of this study is to evaluate the construction performance of the wall. Constructibility reviews are performed throughout interview survey from builders who charge with managing the construction of the lightweight wall in field. This paper present that constructor prefer the bearing wall rather than the lightweight wall because of the schedule delay, difficulty of management, and lack of skilled labor. The results indicate what we should improve on the lightweight wall from now on.

  • PDF

Effect of elevated temperature on physico-mechanical properties of metakaolin blended cement mortar

  • Morsy, M.S.;Rashad, A.M.;El-Nouhy, H.A.
    • Structural Engineering and Mechanics
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2009
  • An experimental investigation was conducted to evaluate the performance of mortars with and without Metakaolin (MK) exposed to elevated temperatures $200^{\circ}C$, $400^{\circ}C$, $600^{\circ}C$ and $800^{\circ}C$ for two hours. The binder to sand ratio was kept constant (1:5.23). The ordinary Portland cement (OPC) was replaced with MK at 0%, 5%, 10% 20% and 30%. All mixtures were designed to have a flow of $94{\pm}5%$. The compressive strength of mortars before and after exposure to elevated temperature was determined. The formation of various decomposition phases were identified using X-ray diffractometry (XRD) and differential thermal analysis (DTA). The microstructure of the mortars was examined using scanning electron microscope (SEM). Test results indicated that MK improves the compressive strength before and after exposure to elevated temperature and that the 20% cement replacement of MK is the optimum percentage.

Microstrip Directional Coupler Design with High Performance Using Optimization based on Evolution Strategy

  • Joung, Myoung-Sub;Park, Jun-Seok;Kim, Hyeong-Seok;Lim, Jae-Bong;Cho, Hong-Goo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.6
    • /
    • pp.276-281
    • /
    • 2004
  • In this paper, the optimal design of a novel microstrip directional coupler with a grooved housing for high directivity characteristic is presented. It will be shown that the high directivity of the microstrip coupler can be achieved simply by attaching an optimized housing structure. over the microstrip, which is much easier to fabricate than other conventional types. The dimensions of the proposed structure are maximized by using (1+1) evolution strategy (ES) combined with the deterministic algorithm. To improve the effectiveness of the results, efficient optimization procedures suitable for the model are proposed. From these results, it is determined that the proposed structure indicates an improved directivity. The optimized results are verified by full wave analysis at the center frequency of 850MHz.

A Study on the Pattern of Price Variation for the Remodeled Multi-Family Housing (리모델링 사업에 따른 공동주택의 가격변화에 관한 연구)

  • Kim, Jaesung;Cho, Kyuman;Kim, Taehoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.257-258
    • /
    • 2016
  • Construction of Multi-Family Housing(MFH) was rapidly spread in the 1990s, it has been mostly passed more than 20 years and it is faced to aging time. Remodeling has emerged a major issue in the construction industry as an alternative of improvement and recovery the initial performance of the deteriorated MFH. But, Many decision-makers are struggling to determine whether to conduct a remodeling because of profitability. In this context, this research was conducted as the following steps to achieve this research goal, i) remodeled MFH cases and comparative cases were collected, ii) the price information based on three time frames (i.e., before remodeling, after remodeling, and present) was collected, and iii) the relative price variation of the remodeled cases was analyzed and finally it is revealed that there are four patterns of price variation.

  • PDF