• Title/Summary/Keyword: Housing Energy Consumption

Search Result 173, Processing Time 0.021 seconds

Calibration and Verification of Detailed Prototypical Apartment Building Energy Models for Estimation of Green Remodeling Feasibility (그린리모델링 효과평가를 위한 표준공동주택 정밀에너지해석모델 보정과 검증)

  • Donghyun Seo
    • Land and Housing Review
    • /
    • v.15 no.2
    • /
    • pp.9-17
    • /
    • 2024
  • The prototypical building energy model is very useful in building energy policies, research, and technology development. A prototypical apartment model for detailed energy analysis was proposed by Seo et al. in 2014, but sufficient verification was not possible due to the lack of reliable measurement data in predicting the model's energy consumption. However, verification is now possible thanks to a recent study that analyzed the Household Energy Panel Survey (HEPS) data that is released annually by the Korea Energy Economics Institute (KEEI) and published apartment complex benchmark data. The data was used to calibrate the prototypical apartment energy model located in the central region and constructed between 1990 and 1999. The calibrated model was used to verify the other apartment building groups with respect to region and year of completion. Meteorological data for five representative cities each in the central and southern regions were used for the simulation. A majority of the 18 groups produced results that satisfied the MBE and cv(RMSE) criteria.

Properties of lightweight matrix for inorganic insulation by cement types (시멘트 종류별 무기단열재용 경량 경화체의 특성)

  • Lim, Jeong-Jun;Pyeon, Su-Jeong;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.222-223
    • /
    • 2018
  • Recent government policies are increasing interest in zero-energy housing, a building that minimizes energy consumption (90% reduction). As the importance of building passive performance is emphasized, the role of insulation is increasing as a way to reduce indoor heat loss in order to minimize the use of cooling and heating energy. There are two main types of insulation. Organic insulation is widely used for various construction structures such as construction and industrial due to some merits such as the convenience of construction and construction cost. However, it has been pointed out as a main cause every time a fire accident occurs, Jecheon Sports Center', the fire damage of buildings caused by the use of organic insulation materials is expanding to social problems, so it is urgent to research on nonflammable inorganic insulation materials.

  • PDF

Exploring Residents' Attitudes in Multifamily Housing Toward Food Waste Zero-Emission System with Fermentation and Extinction Technology (발효·소멸 기술을 이용한 음식물 쓰레기 무배출 시스템에 대한 공동주택 거주자의 태도에 관한 분석)

  • Oh, Jeongik;Lee, Hyunjeong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.321-333
    • /
    • 2013
  • As environmental sustainability becomes a key consideration in policy-making, more responsible consumption and utilization in daily life concern both health and quality of life. To address inequities in health in relation to environments, waste management has taken more progressive ways, and one of them is biomass-to-energy conversion that utilizes energy recovery from food waste. By extension, a food waste zero-emission system using fermentation and extinction technology gains much attention, so that this study is designed to examine residents' attitudes toward recycling food waste produced at home and toward food waste zero-emission system. Utilizing a survey questionnaire, this research collected data from 400 individual units of multifamily housing estates nationwide, and the data were analyzed using descriptive and inferential statistics. The findings indicate that food waste generated at home was highly water-contained and produced in the stage of food preparation before cooking while respondents viewed that food waste collection and treatment needed to be improved. It's noted that respondents strongly supported the use of food waste as a energy source and would have the use of the food waste zero-emission system built in kitchen sink. Regression analysis showed that educational attainment of housewives, cooking style, and planning food purchase were statistically significant factors in the attitude of the responded residents toward recycling food waste while none of the factors were in the attitude toward the food waste zero-emission system.

The Analysis on Energy Performance Index of the Green Building Certified Apartment Buildings in Korea (공동주택 친환경인증단지의 에너지성능지표 비교분석 연구)

  • Kim, Jong-Yeob;Jung, Yoon-Hye;Paik, Hae-Sun
    • Land and Housing Review
    • /
    • v.4 no.4
    • /
    • pp.407-415
    • /
    • 2013
  • Although many certification works have been carried out since Green Building Certification was enforced in 2002, analyses of the effects and efforts to improve this system are still poor. In the certification system, the energy performance was usually assessed by Energy Performance Index(EPI) of the Energy Saving Design Standards for Buildings. However, due to the inadequacy of analyses on current situation of the Index, there are difficulties to reform it. In this research of green-certified apartments, the author examined correlations between energy performance indexes and aimed to improve the Index by analyzing the scores based on point distribution of respective fields. The average EPI score of green-certified apartments was 74.68, and there was wide variations in min 63.4 and max 90. Furthermore, the average score of energy consumption, which was allotted the most points, was 7.04 out of 12. Therefore, betterments in the Index such as reinforcement in grade ranges and adjustment of the calculation method are necessary.

Evaluation on Heating Effects of Geothermal Heat Pump System in Farrowing House (지열 난방시스템을 이용한 분만돈사의 난방효과 분석)

  • Choi, H.C.;Park, Jae-Hong;Song, J.I.;Na, J.C.;Kim, M.J.;Bang, H.T.;Kang, H.G.;Park, S.B.;Chae, H.S.;Suh, O.S.;Yoo, Y.S.;Kim, T.W.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.205-215
    • /
    • 2010
  • Geothermal heat pump system (GHPS) is an energy-efficient technology that use the relatively constant and renewable energy stored in the earth to provide heating and cooling. With the aim of using GHPS as a heating source, it's possibilities of application in farrowing house were examined by measuring environmental assessment and sow's performance. A total of 96 sows were assigned to 2 pig housings (GHPS and conventional housing) with 48 for four weeks in winter season. During the experimental period, indoor maximum temperature in GHPS-housing was measured up to $26.7^{\circ}C$, average temperature could maintain $21.2^{\circ}C$. The mean value of dust levels and $CO_2$, $NH_3$ and $H_2S$ gas emissions were decreased in GHPS-housing compare with those of conventional housing. Litter size, birth weight, parity and weaning weight did not differ between housings. However, feed intake of sow in GHPS-housing was lower than that of conventional housing. In energy consumption for heating, electric power consumption increased in GHPS-housing than the conventional housing, a 2,250 kwh increase, whereas there is no fuel usage for heater in GHPS-housing. Amount of ground water circulated for heating in cold weather for earth heat exchanger was 8.4-12.9 ton per day. In conclusion, GHPS may have environmental benefits and effectiveness of heating in farrowing housing and affect the performance in sows.

Insulation Performance Evaluation of Apartment Housing Using Infra-red Camera (적외선 열화상을 이용한 공동주택 단열성능 평가 - TDR(온도상대비)을 중심으로 -)

  • Choi, Bo-Hye;Choi, Gyoung-Seok;Kang, Jae-Sik;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.718-723
    • /
    • 2009
  • The purpose of this study is to present an in-site evaluation method for building insulation performance using Infra-red camera. The research contents of this study are to evaluate validity and suitability of building insulation defect survey using Infra-red camera for apartment housing with temperature & heat flow pattern analyze method. By establishing the in-site evaluation method building insulation performance using infra-red camera, it is expected that 1) building envelope repair market will be activated by using developed method in ESCO and remodeling companies, 2) the method developed in this research will contribute to reduce national energy consumption by promoting old building insulation remodeling.

  • PDF

Improvement of Compressor EER Based on Shape of Gap Flow Passage (압축기 갭 유로 형상에 따른 압축기 EER 향상)

  • Han, Sang-Hyeok;Lee, Young Lim
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.3
    • /
    • pp.63-69
    • /
    • 2022
  • Compressor efficiency must be improved to reduce refrigerator power consumption. In this study, the heat dissipation rate through the compressor housing is increased via gap flow passages between the compressor body and housing. Four types of gap flow passages are considered for achieving the maximum heat-dissipation rate. In addition, thermal analysis is performed to examine the effect of increased heat dissipation rate on the energy efficiency ratio (EER). The results show that the heat dissipation rate, compressor superheat, and compressor EER increased by up to approximately 52%, 3 ℃, and approximately 1%, respectively.

A Basic Study on the Method of Building Energy Management Based on Digital Space Modeling and Ubiquitous IT Technology (디지털 공간모델링 기법과 유비쿼터스 IT 기술을 접목한 빌딩 에너지 관리방법에 관한 기초연구)

  • Park, Yong-Jun;Park, Nam-Hee;Choi, Jin-Won
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.181-186
    • /
    • 2009
  • Recently, the consuming efficiency of energy and natural resources has been a hot issue because of the continuous increasing of energy consumption and soaring of international oil prices. We tried to seek an action plan for the government's new paradigm 'Low-Carbon, Green Growth' by consuming energy efficiently and improving in energy management based on ubiquitous IT technologies. In this study, the library survey method is adopted for this study and IP-USN(internet protocol based ubiquitous sensor network) is considered as a core technology among various ubiquitous IT technologies. The purpose of this study is to deliver a method of energy management through integrating the context information gathered from sensors with digital space models and visualizing them together. The details are to survey the technologies of digital space modeling, USN based monitoring, building energy management and to integrate these technologies all together. This study will contribute to the enhancement of efficient building energy management by grasping the accurate situation of energy consuming in the building in realtime and minimizing unnecessary energy wastes.

  • PDF

Local Agenda Actural Condition and Direction of Architecture (건축분야의 지방의제 현황과 방향)

  • Ahn, Tae-Kyung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.5 no.2
    • /
    • pp.1-9
    • /
    • 2003
  • Local Agenda 21 insists Local National role for earth environmental preservation. It is effect in earth environment important code that each local government promotos Local Agenda 21. Local agenda requires changes in lifestyle from everyone, such as limiting use of energy.Local agenda is difficult to define. But the goal of agenda development can guide furure policy. In this study, investigated local agenda actural condition and housing present condition, energy consumption. It is analyzed practice item of city and architecture local agenda. It is also proposed data of architecture and presented direction of architecture local agenda.

  • PDF

A Study on the Adaptable Long Life Multi-dwelling Housing Design in Korea (융통성을 고려한 장수명 공동주택 디자인에 관한 연구)

  • Kim, Jin-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.6 s.59
    • /
    • pp.172-177
    • /
    • 2006
  • Most of the Korean multi-dwelling houses have less than 20 years of lifespan. Because the environmental issues such as energy consumption, limited resources, and demolition waste problems became been more and more critical, we now need to focus on long lasting and adaptable buildings. Korean wall bearing apartment buildings are constructed with site cast concrete for core, exterior, and interior together with pipes varied, so when the buildings are old and life style of the users changes, it is difficult to maintain and renovate these buildings. In this study, to resolve the problems described above, two types of Korean long life multi-dwelling housing models which represent improved durability and adaptability responding user's needs and life style changes were proposed with various methods as follows: Either column and beam structure or flat slab structure was used to utilize space better. To make maintenance easier and renovation economical for both public space and each unit, plumbing pipes, ducts, and conduits were clustered at the cores and public corridors with access doors and light weight partitions with steel studs and raised floors or above-ceiling spaces were used in lieu of site cast concrete walls and floor slabs with varied pipes.