• 제목/요약/키워드: House dust particles

검색결과 6건 처리시간 0.033초

생쥐에서 가정분진 입자로 인한 항원관련 호산구성 기도 염증과 기도 과민성의 증대 (Enhancement of Allergen-related Eosinophilic Airway Inflammation and Airway Hyperresponsiveness by House Dust Particles in Mice)

  • 임흥빈;김승형
    • 한국대기환경학회지
    • /
    • 제24권3호
    • /
    • pp.321-328
    • /
    • 2008
  • The number of patient with allergic asthma and atopy have increased in the cities of Korea steadily. In order to elucidate the primary factor, we investigated whether the house dust particles collected from an apartment of the middle classes has promoting effects of allergen-related airway inflammation and airway hyperresponsiveness. Mice were treated with 0.1 mL of 1 mg/mL of house dust particles suspension by intratracheal instillation once weekly for 10 weeks combined with ovalalbumin (OVA) sensitization. Intratracheal instillation of house dust particles and OVA sensitization caused an increase in the level of serum L-lactate dehydrogenase (LDH), immunoglobulun-E (IgE) and histamine, and an elevation in respiratory resistance. It also enhanced infiltration of eosinophils in the bronchoalveolar lavage fluid (BALF) of mice, IgE and eotaxin expression in blood, and T helper type 2 cell derived cytokine levels such as of interleukin (IL)-4, IL-13 and IL-5 in the BALF. However, it did not influence T helper type 1 cytokine such as interferon-gamma in the BALF. These results indicate that house dust particles elevate allergen-related airway inflammation and airway hyperresponsiveness in mice and may play an important role in the aggravation of asthma and atopy in Korea.

실내환경 중 집먼지 및 유기필름에서 기인한 프탈레이트 노출평가 (Exposure Assessment of Phthalates from House Dust and Organic Films in the Indoor Environment)

  • 전정인;이혜원;이승현;이정일;이철민
    • 한국환경보건학회지
    • /
    • 제48권2호
    • /
    • pp.75-85
    • /
    • 2022
  • Background: Various types of semi-volatile organic compounds (SVOCs) exist in the public's living environment. They occur in different forms in terms of their physical and chemical properties and partition coefficients. As a consequence, indoor exposure to SVOCs occurs via various routes, including inhalation of air and airborne particles, skin contact, and dust intake. Objectives: To propose a method for assessing human exposure to the SVOCs occurring in the air of an indoor environment, the concentrations of SVOCs in house dust and organic films measured in a real residential environment were estimated in terms of gas-phase concentration using the partition coefficient. Assessment of inhalation exposure to SVOCs was performed using this method. Methods: Phthalates were collected from samples of house dust and organic films from 110 households in a real residential environment. To perform an exposures assessment of the phthalates present in organic films, gas-phase concentration was calculated using the partition coefficient. The airborne gas-phase concentrations of phthalates from the house dust and organic films were estimated and exposure assessment was performed based on the assumption of inhalation exposure from air. Results: As a result of the exposure assessment for gas-phase phthalates from house dust and organic films, preschool children showed the highest level of inhalation of phthalates, followed by school children, adults, and adolescents. Conclusions: This study includes the limitation of not considering different SVOCs exposure pathways in the health impact assessment, including those of phthalates in the indoor living environment. However, this study has the significance of performing exposure assessment based on exposure to SVOCs present in indoor air that originated from organic films in the indoor residential environment. Therefore, the results of this study should be useful as basic data for exposure and health risk assessments of SVOCs associated with organic films in the indoor environment.

유우사 내부 위치 및 작업 형태에 따른 분진 모니터링 및 분석 (Analysis of Dust Concentration in Dairy Farm according to Sampling Location and Working Activities)

  • 박관용;권경석;이인복;하태환;김락우;이민형
    • 한국농공학회논문집
    • /
    • 제59권3호
    • /
    • pp.71-81
    • /
    • 2017
  • Organic dust generated inside livestock facilities includes toxic organic matters such as bacteria and endotoxin. Dust can cause respiratory disease for worker and livestock, and consequently, degradation of welfare and productivity. Influence of dust on livestock workers has been studied since the 1970s. However, exposure limit for cattle farmer has not been established, unlike exposure limit for pig and poultry farmer. Furthermore, study on air quality inside livestock facility, especially inside dairy farm has been rarely conducted in Korea. In this study, dust concentration of TSP, PM10, inhalable and respirable dust has been monitored in the commercial dairy house according to location and working activities. Bedding material inside the stall was one of the major sources of dust. The amount of dust was related to water content level of the bedding material. Dust concentration was relatively high in leeward location, and the highest concentration was measured during TMR mixing process. The maximum value of inhalable dust concentration was 29.1 times higher than the reference value as fine particles drop to the TMR mixer. Dust generated by TMR mixing was presumed to decrease by adjusting moisture and drop height of feed.

일부지역 양돈장 및 양계장 공기중 박테리아, 진균, 내독소 농도 (Evaluation of Environmental Circumstance Within Swine and Chicken Houses in South Korea for the Production of Safe and Hygienic Animal Food Products)

  • 김영환;서형주;김진만;정연훈;문경환
    • 한국축산식품학회지
    • /
    • 제28권5호
    • /
    • pp.623-628
    • /
    • 2008
  • This study was undertaken to determine the concentrations of airborne bacteria, fungi, particles, and endotoxin in swine and chicken houses. Six swine buildings and seven chicken houses were randomly selected in southern Gyonggi Province, South Korea. The geometric mean concentrations of airborne bacteria in swine and chicken houses were $2.7{\times}10^5\;CFU/m^3$ and $5.6{\times}10^7\;CFU/m^3$, respectively. The airborne bacteria concentrations in chicken houses were significantly higher than those of swine houses (p<0.05). The geometric mean concentration of airborne fungi in swine houses was $4.9{\times}10^3\;CFU/m^3$, which was higher than the value of $2.1{\times}10^3\;CFU/m^3$ found in chicken houses. The mean concentrations of airborne particles and endotoxin in swine houses were $3.48\;mg/m^3$ and $943.1\;EU/m^3$, and they were $15.43\;mg/m^3$ and $1,430.5\;EU/m^3$ in chicken houses, respectively. A significant difference between swine and chicken houses was found for total dust (p<0.05), but not for endotoxin. In this study, the concentrations of endotoxin in both swine and chicken houses as well as particles in chicken houses were high, and in about 50% of the samples exceeded the worker health safety levels of $614\;EU/m^3$ suggested in previous studies. These results may indicate a considerable respiratory hazard for workers in these environments.

패시브 공동주택 계획을 위한 설계 중점항목 및 관련 기준 연구 (A Study of Critical Items and Related Standards on Designing for Passive Apartments)

  • 이명주
    • 대한건축학회논문집:계획계
    • /
    • 제34권7호
    • /
    • pp.21-29
    • /
    • 2018
  • This study aimed to find and suggest the purpose of future plans, critical items on designing and Related standards to amend construction standards for domestic energy saving and environmentally friendly housings. It would also activate and increase the supplies of passive house minimizing the problems on current apartment housings in winter and reducing heating energy which brings fine dust pollution. After defining the standard model of Korean apartment housings(reference model), this study calculated the amount of heating energy demand per unit area annually as applying the yearly changed standards from 2008 to 2017 to existing standard model. It turned out that applying 2017 construction standards of energy saving and eco-friendly housings to reference model has saved up to 75% of heating energy demand comparing to the one applied 2008's. However, it still could not solve the fundamental problems such as winter fungus, condensation, freezing, freeze and burst, and insulation weakness space, and could not be free from fine dust particles. To solve them, this study suggested improved standards adding critical items on design related to outside insulation, cut off the heat-bridge, enforce air-tightness and heat change efficiency on heat recovery ventilator. As a result, it has reduced more than 10% of heat demand from 2017. It would be more than 90% of savings from 2008 if we make the amount of heat loss be zero on heat bridge on designing stage in the future.

무창 육계사의 계절별 먼지 농도와 특성 연구 (Seasonal Dust Concentration and Characteristics of Windowless Broiler Building)

  • 최희철;연규영;송준익;강희설;권두중;유용희;바로가;양창범;천상석;김용국
    • 한국축산시설환경학회지
    • /
    • 제11권3로
    • /
    • pp.197-206
    • /
    • 2005
  • 본 연구는 무창육계사의 계절별 먼지 농도와 계사 먼지의 특성을 알아보고자 경기 화성 소재 육계농장의 무창계사에서 시험을 수행하였으며 결과는 다음과 같다. 1 여름철 무창육계사의 주령별 먼지농도는 TSP의 경우 1주령 1,229, 2주령 904.5, 3주령 558.8 그리고 4주령시 $1,053{\mu}g/m^3$이었다. 2. 겨울철에는 주령이 경과함에 따라 급격히 증가하는 경향이었으며, TSP의 경우 1주령시 465.4, 2주령시 1,401, 3주령시 4,497, 4주령시 5,097 그리고 5주령시 $6,873{\mu}g/m^3$이었다. 3. 겨울철 5주령시 최대 TSP량은 $11,132{\mu}g/m^3$을 보여 노출기준에 비하여 매우 높게 검출되었다. 4. 하루중의 먼지 분포는 여름철의 경우 이른 아침에 높게 나타났으며 환기량이 많은 오후에 최소량이 검출되었다 그러나 겨울철에는 이른 아침에 낮은 량이 검출되고 닭의 활동이 많은 오후에 먼지농도가 높게 검출되었다. 5. 먼지 입자 크기 분포에 있어서 숫자 기준으로 하였을 경우에는 $0.05\~0.35{\mu}m$ 크기의 먼지 분포가 높게 나타났으나 용적을 기준으로 하였을 경우에는 $16\~99{\mu}m$의 큰 먼지가 높은 분포를 보였다. 6. 먼지의 조단백질 함량은 DM기준으로 $42.8\~65.2\%$를 보여 급여사료의 조단백질 함량 $20.5\~24.5\%$에 비하여 높았으며 중금속의 경우에도 급여사료에 비하여 높은 농도를 보였다

  • PDF