• Title/Summary/Keyword: Hounsfield

Search Result 165, Processing Time 0.032 seconds

Biomedical evaluation of the vertebra based on bone density (골밀도를 고려한 척추의 생체역학적 평가)

  • Kim D.R.;Chae S.W.;Choi K.W.;Lee T.S.;Park J.Y.;Suh J.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1921-1924
    • /
    • 2005
  • In this paper, three-dimensional finite element analysis have been performed to investigate the biomechanics of vertebroplasty in patient. In order to apply various properties of the spine, the functional relation between the well-known apparent density and HU(Hounsfield unit) from CT image were employed and thus real material property can be assigned to each element of FE model. The FE analysis showed similar results with the experiments. With this approach accurate analysis of the spine and the clinical application can be expected.

  • PDF

A Case Report of Lipomatosis in the Pleura (흉막에 발생한 다발성 지방종의 치험 1례)

  • Kim, Jun-U;Kim, Su-Cheol;Jo, Gyu-Seok
    • Journal of Chest Surgery
    • /
    • v.27 no.10
    • /
    • pp.885-887
    • /
    • 1994
  • Lipomatosis is a condition containing multiple lipomatous masses.Lipoma is a benign neoplasm composed of adult adipose tissue, and occur most often in the fifth or sixth decade and rarely in the pleura. Pleural lipomas are usually asymptomatic and revealed as an incidental roentgenographic findings. The patient was 59 year-old male and admitted because of dyspnea-on-exertion for 30 years. Chest CT revealed right pleural mass abutting on the chest wall, measuring minus 80 hounsfield units. The mass was resected with calcified pleural plaque and confirmed to be lipomatosis with collagenous fibrosis arising from viserai pleura.

  • PDF

The methods of distinguishing between HCC and HH in Liver CT scan (Liver CT 영상에서 간세포암과 간혈관종 구별에 대한 연구)

  • Hwang, In-gil;Ko, Seong-Jin;Choi, Seok-Yoon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.173-174
    • /
    • 2015
  • 간에서 발생하는 악성종양과 양성종양의 대표적 질환 으로는 간세포암(Hepatocelluar carci- noma, HCC)과 간혈관종(Hepatic hemangioma, HH)이다. CT검사를 이용한 진단에 있어서 두 질환은 시간변화에 따른 조영증강양상 차이가 나타난다. Liver 3-phase computed tomography검사를 시행하여 시간별 조영증강 양상을 알아보았다. 본 연구는 조영제 주입전, 동맥기(35sec), 문맥기(70sec), 지연기(180sec)에 대한 Enhan -cement Pattern 변화와 HU(Hounsfield unit)값 변화, pixel값 변화의 관찰로서 검증하였다. 실험결과 HU를 사용한 방법에서 의미있게 구분되었고 임상적용 시 판독에 도움을 줄 것으로 생각한다.

  • PDF

Imaging diagnosis of hepatic lipidosis in a cat

  • Heo, Seong-Hun;Yoon, Young-Min;Hwang, Tae-Sung;Jung, Dong-In;Lee, Hee-Chun
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.2
    • /
    • pp.99-101
    • /
    • 2018
  • A 5-year-old intact female Persian cat was referred with anorexia and vomiting. Physical examination revealed icterus in the pinna, oral mucosa, and sclera. Ultrasonography revealed several findings including uniformly hyperechoic hepatic parenchyma compared to adjacent falciform fat, increased attenuation of the ultrasound beam, and poor visualization of intrahepatic vessel borders. Computed tomography revealed hypoattenuation of the hepatic parenchyma with a radiodensity value of -60 Hounsfield units. The adjacent intrahepatic vessels appeared hyperattenuated relative to the hepatic parenchyma as if the vessels were contrast-enhanced. Based on ultrasonography and computed tomography results, the cat was tentatively diagnosed as feline hepatic lipidosis.

Biomechanical Evaluation of the Vertebroplasty Based on Bone Density (골밀도를 고려한 척추성형술의 생체역학적 평가)

  • Kim Dong-Ryul;Lee Tae-Soo;Park Jung-Yul;Suh Jung-Gun;Choi Kui-Won;Chae Soo-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.8 s.185
    • /
    • pp.185-194
    • /
    • 2006
  • In this paper, three dimensional finite element analyses have been performed to investigate the biomechanics of vertebroplasty in patient accurate FE models have been constructed from CT images of a PMMA injected vertebra. In order to apply various material properties of the spine(T12), the functional relation between the well known apparent density and HU(Hounsfield unit) from CT image were employed and thus real material properties can be assigned to each element of FE model. The FE analysis showed similar results with the experiments. With this approach accurate analysis of the vertebroplasty and its clinical applications can be expected.

CT in Penetrating Wooden Foreign Bodies of Head and Neck (공기음영으로 오인될 수 있는 두경부 영역의 관통성 나무이물에 대한 컴퓨터 전산화 단층촬영의 의의)

  • 오승철;김찬우;박병훈;강인봉;김선태;장일환;차흥억;이선규
    • Korean Journal of Bronchoesophagology
    • /
    • v.4 no.1
    • /
    • pp.142-147
    • /
    • 1998
  • Retained wooden foreign bodies following penetrating trauma are a difficult diagnostic problem. However, penetrating wooden foreign bodies of head and neck have the potential for misinterpretation or failure to detect such foreign bodies on CT. Given the likelihood that such a miss will result in an abscess or neurovascular injury, we present the method with higher window settings, they had a higher attenuation with a unique striated internal architecture and different Hounsfield numbers readily differentiate air and non-air hypodense material such as fat, or possibly wood. Being aware of the potential appearance of wood, we may also find CT useful in excluding small retained fragments in postoperative patients with persistent symptoms. This article presents two cases in which wooden foreign bodies of head and neck were present with CT evaluation.

  • PDF

Computed Tomographic Features of Canine Ovarian Masses

  • Hong, Sae-Byel;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.39 no.3
    • /
    • pp.107-113
    • /
    • 2022
  • This paper describes the computed tomographic features of ovarian masses in dogs. The CT images of female dogs with a confirmed histological diagnosis of ovarian tumors or ovarian cystic diseases were studied retrospectively. Seven dogs met the inclusion criteria. The morphological features of ovarian tumors and ovarian cystic diseases coincided to a certain degree, but ovarian tumors tended to be predominantly solid. Objective measurements of Hounsfield units (HU) suggest that benign lesions may show lower HU values than malignant tumors and mild contrast enhancement because of the small soft tissue composition. CT is useful for a differential diagnosis of ovarian masses by providing additional information on the imaging features of the masses and an evaluation of metastases.

Spectral CT Analysis of Hounsfield Unit (HU) according to MonoE (keV) and Dilution Ratio of the Contrast Agent: Use of Spectral CT (단색에너지(keV)와 조영제 희석비율 변화에 따른 HU(Hounsfield Unit)값 분석: Spectral CT 이용)

  • Jung, Hee-Ra;Kang, Jin-woo;Kwon, Oh-Jun;Kim, Ho-Jin;Jung, Dabin;Lee, Jae-Hyun;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.669-676
    • /
    • 2020
  • The purpose of this study was to analyze the changes in the values of Hounsfield Unit (HU) according to the changes in monoenergy (keV) and dilution ratio of the contrast agent, using the spectral CT. Spectral CT was used as the testing device, while 20 cc syringe phantom was used to set a total of six dilution ratios of the contrast agent: 8:2, 7:3, 6:4, 5:5, 4:6, and 3:7. Here, the non-ionic iodine solution (350 mg/ml) was used as a contrast agent. The syringe axial image was reconstructed by adjusting the obtained data on nine MonoE levels; 40 keV, 45 keV, 50 keV, 55 keV, 60 keV, 65 keV, 70 keV, 75 keV, and 80 keV. The HU values were measured at the three points of the reconstructed syringe axial image. The measurements were taken 1,620 times in total. In the analysis of the HU values according to the changes in keV and dilution ratio of the contrast agent, the highest and lowest HU values were obtained from dilution ratio 8:2 and dilution ratio 3:7, respectively, across every MonoE in the comparison of HU according to dilution ratio per MonoE (p<0.05), while the highest and lowest HU values were obtained from 40 keV and 80 keV, respectively, across all dilution ratios in the comparison of HU according to MonoE per dilution ratio (p<0.05). For the correlation per each parameter, a negative correlation of -15.014 ± 0.298 was found for HU per keV (R2=0.519) and a negative correlation of -61.372 ± 3.608 was found for HU per dilution ratio (R2=0.152) (p<0.05). To conclude, an increase in keV or dilution ratio of the contrast agent was shown to decrease the HU, and the findings in this study are anticipated to serve as the basic data in the research of HU-related parameters in Spectral CT.

Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System (전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가)

  • Yu, Minsun;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.455-464
    • /
    • 2012
  • This study suggested evaluation of approximately exposure to low-dose ionization radiation from medical images using a computed radiography (CR) system in standard X-ray examination and experimental model can compare diagnostic reference level (DRL) will suggest on optimization condition of guard about medical radiation of low dose space. Entrance surface dose (ESD) cross-measuring by standard dosimeter and optically stimulated luminescence dosimeters (OSLDs) in experiment condition about tube voltage and current of X-ray generator. Also, Hounsfield unit (HU) scale measured about each experiment condition in CR system and after character relationship table and graph tabulate about ESD and HU scale, approximately radiation dose about head, neck, thoracic, abdomen, and pelvis draw a measurement. In result measuring head, neck, thoracic, abdomen, and pelvis, average of ESD is 2.10, 2.01, 1.13, 2.97, and 1.95 mGy, respectively. HU scale is $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, and $2,318{\pm}4.64$, respectively, in CR image. At this moment, using characteristic relationship table and graph, ESD measured approximately 2.16, 2.06, 1.19, 3.05, and 2.07 mGy, respectively. Average error of measuring value and ESD measured approximately smaller than 3%, this have credibility cover all the bases radiology area of measurement 5%. In its final analysis, this study suggest new experimental model approximately can assess radiation dose of patient in standard X-ray examination and can apply to CR examination, digital radiography and even film-cassette system.

CT Scan Findings of Rabbit Brain Infection Model and Changes in Hounsfield Unit of Arterial Blood after Injecting Contrast Medium (토끼 뇌감염 모델의 CT 소견과 조영제 주입 후 동맥혈의 Hounsfield Unit의 변화)

  • Ha, Bon-Chul;Kwak, Byung-Kook;Jung, Ji-Sung
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.270-279
    • /
    • 2012
  • This paper explores CT findings of a rabbit brain infection model injected with Escherichia coli and investigates the changes in Hounsfield unit (HU) of arterial blood over time. The brain infection model was produced by injecting E. coli $1{\times}10^7$ CFU/ml, 0.1 ml through the burr hole in the calvarium; 2~3 mm in depth from the dura mater, and contrast-enhanced CT, dynamic CT and arterial blood CT images were gained. It was found that various brain infections such as brain abscess, ventriculitis and meningitis. The CT image of brain abscess showed a typical pattern which the peripheral area was strongly contrast-enhanced while the center was weakly contrast-enhanced. The CT image of ventriculitis showed a strong contrast-enhancement along the lateral ventricle wall, and the CT image of meningitis showed a strong contrast-enhancement in the area between the telencephalon and the diencephalon. In dynamic CT images, the HU value of the infection core before injecting contrast medium was $31.01{\pm}3.55$. By 10 minutes after the injection, the value increased gradually to $40.36{\pm}3.76$. The HU value in the areas of the marginal rim where was hyper-enhanced showed $47.23{\pm}3.12$ before contrast injection, and it increased to $63.59{\pm}3.31$ about 45 seconds after the injection. In addition, the HU value of the normal brain tissue opposite to the E. coli. injected brain was $39.01{\pm}3.24$ before the injection, but after the contrast injection, the value increased to $49.01{\pm}4.29$ in about 30 seconds, and then it showed a gradual decline. In the arterial blood CT, the HU value before the contrast injection was $87.78{\pm}6.88$, and it increased dramatically between 10 to 30 seconds until it reached a maximum value of $749.13{\pm}98.48$. Then it fell sharply to $467.85{\pm}62.98$ between 30 seconds to 45 seconds and reached a plateau by 60 seconds. Later, the value showed a steady decrease and indicated $188.28{\pm}25.03$ at 20 minutes. Through this experiment, it was demonstrated that the brain infection model can be produced by injecting E. coli., and the characteristic of the infection model can be well observed with contrast-enhanced CT scan. The dynamic CT scan showed that the center of the infection was gradually contrast-enhanced, whereases the peripheral area was rapidly contrast-enhanced and then slowly decreased. As for arterial blood, it increased significantly between 10 seconds to 30 seconds after the contrast medium injection and decreased gradually after reaching a plateau.