• 제목/요약/키워드: Hot-fire Test

검색결과 69건 처리시간 0.022초

화재사례 및 재현실험을 통한 온도조절장치 고장 및 오동작으로 인한 전자제품 화재 메커니즘 분석 (A Study on the Analysis of Fire Mechanisms in Electronic Products due to Failure and Malfunction of Thermostats Through Fire Cases and Reproduction Experiments)

  • 이정일;임종화
    • 대한안전경영과학회지
    • /
    • 제26권1호
    • /
    • pp.31-38
    • /
    • 2024
  • In this paper, as there are many cases of fires occurring due to the failure or inoperability of the thermostat of electronic products, the purpose is to test and analyze the risks and probabilities through fire cases and reproduction experiments, and suggest countermeasures. Among electronic products, water purifiers are composed of a refrigerant system with a compressor to make cold water, a heating device to make hot water, and an electric device used as an energy source. Due to the nature of the water purifier manufacturing, these devices are subject to a lot of moisture and dust. etc. exist in large quantities and use electrical energy, so there is a possibility of fire due to short circuit in the wire, electrical abnormal overheating (tracking phenomenon) in the thermostat, electronic board, starting relay, etc., and overheating of the heating device (Band Heater). there is. Therefore, in order to prevent fires from these devices, a system to remove foreign substances inside the water purifier is necessary, the use of heat-resistant (fire-resistant) wires for electrical devices is essential, and the use of non-combustible materials (semi-combustible materials) for each part is necessary to prevent fire. The risk must be eliminated through prevention and combustion expansion prevention devices.

F-O-O-F 충돌형 injector의 분무특성 및 혼합성능에 관한 실험적 연구 (An Experimental Study on the Characteristics of Spray Pattern and the Mixing Performance of Unlike-impinging Split Triplet Injector(F-O-O-F))

  • 이광진;문덕용;김유
    • 한국추진공학회지
    • /
    • 제3권3호
    • /
    • pp.1-8
    • /
    • 1999
  • $H_2$O/Kerosene을 사용하여 Unlike 충돌형 인젝터(FOOF형)에서 산화제와 연료의 운동량비 변화에 따른 혼합효율을 측정하였다. 모의 추진제의 운동량비 1.5(총혼합비 1.89)에서 혼합성능은 최대 값을 나타내었으며 모의 추진제의 실험결과는 실제 추진제인 LOX/Kerosene에 적용하여 혼합특성속도 효율을 예측하였다 연구 결과 혼합특성속도 효율은 운동량비 2.0에서 최대 값을 나타내었다. 이러한 예측은 실제 연소실험을 통하여 얻어진 연소효율과 약간의 차이는 있으나 초기설계자료로서 충분한 가치가 있는 것으로 판단된다.

  • PDF

Combustion Stability Characteristics of the Model Chamber with Various Configurations of Triplet Impinging-Jet Injectors

  • Sohn Chae-Hoon;Seol Woo-Seok;Shibanov Alexander A.
    • Journal of Mechanical Science and Technology
    • /
    • 제20권6호
    • /
    • pp.874-881
    • /
    • 2006
  • Combustion stability characteristics in actual full-scale combustion chamber of a rocket engine are investigated by experimental tests with the model (sub-scale) chamber. The present hot-fire tests adopt the combustion chamber with three configurations of triplet impinging-jet injectors such as F-O-O-F, F-O-F, and O-F-O configurations. Combustion stability bound-aries are obtained and presented by the parameters of combustion-chamber pressure and mixture (oxidizer/fuel) ratio. From the experimental tests, two instability regions are observed and the pressure oscillations have the similar patterns irrespective of injector configuration. But, the O-F-O injector configuration shows broader upper-instability region than the other configurations. To verify the instability mechanism for the lower and upper instability regions, air-purge acoustic test is conducted and the photograph or the flames is taken. As a result, it is found that the pressure oscillations in the two regions can be characterized by the first impinging point of hydraulic jets and pre-blowout combustion, respectively.

용융형 스프링클러 헤드의 응답시간 지수 및 작동시간에 관한 연구 (A Study on Response Time Index and Operating Time for Fusible Link Sprinkler Head)

  • 이병곤;태순호
    • 한국안전학회지
    • /
    • 제6권4호
    • /
    • pp.34-44
    • /
    • 1991
  • In this study, the general solution of heat balance equation including conductive heat loss were suggested and were determined the constants with the results of experiment in hot tunnel in order to derive the general equation for the response time and to investigate the response time index which represent the characteristics of response of sprinkler head in actual fires. Two types of test were considered, the plunge test, in which the air temperature is represented by a step function, and the ramp test, in which the air temperature increases at a constant rate. As a result, simple equations were derived, which can be predicted the response time for the ramp type fire with the rate of temperature rise and gas velocity, for the plunge type fire with temperature and gas velocity. Also other useful data, such as the effective temperature, time constant, response time index and conduction parameter were obtained.

  • PDF

합판(合板)의 내화처리(耐火處理)에 관(關)한 연구(硏究) - III. 제1인산(第一燐酸)암모늄처리합판(處理合板)의 내화도(耐火度) (Studies on Plywood Treated Fire-Retardant - III. The Fire-Retardant Degree of Monoammonium Phosphate Treated Plywood)

  • 김종만
    • Journal of the Korean Wood Science and Technology
    • /
    • 제14권4호
    • /
    • pp.21-28
    • /
    • 1986
  • Plywood used for construction as a decorative inner material is inflammable and can fire accident, causing destruction of human life and property. In this study, 3.5mm Kapur plywoods were soaked in the 23% monoammonium phosphate solutions by cold soaking method 3, 6, 9hrs and hot-cold bath method for 3/3hrs, and redrying was carried out by press-drying at the platen temperature of 110, 130, 160, 180$^{\circ}C$, and then fire test was carried out to investigate burning point, flame exhausted length, frame spread length, back side carbonized area and weight loss. The results are as follows; 1. In cold soaking method for 3, 6, 9hrs. retentions of monoammonium phosphate were 0.377, 0.448, 0.498kg/(30cm)$^3$ respectively, and in hot-cold bath method for 3/3hrs, the retention was 1.331kg(30cm)$^3$ that exceeded the minimum retention 1.124kg/(30cm)$^3$. 2. Correlation coefficients among the variable were shown in table 2. From the table, it could be recognized that there were close negative correlations between the treatment and burning point, flame spread length, back side carbonized area, flame exhausted time and weight loss, and there was negative correlation between treating time and back side carbonized area, but there was positive correlation between platen temperature and burning point. 3. From table 3, it can be observed that there were highly significant differences for burning point, flame spread length, flame exhausted time, back side carhonized area, weight loss between treatments. And in 2-way interactions, there were also highly significant for burning point, flame spread length, flame exhausted time, weight loss between time x treatment. 4. It was observed that burning point, flame exhausted time, flame spread length, back side carbonized area, and weight loss in fire-retardant treated plywood were the best effects in fire-retardant treated plywood, water treated plywood and nontreated plywood. In conclusion, I can estimate that absorbed chemical contents by hot-cold bath method for 3/3hrs, have a lot of effects on fire-retardant factors such as burning point, flame spread length, flame exhausted time, backside carbonized area and weight loss, but platen temperatures have a little effects on the fire factors.

  • PDF

열전대에 의한 화재유동의 온도측정에 관한 검토 - 측정오차 (A Review of Temperature Measurement of Fire Driven Flow Using Thermocouple - Measurement Bias)

  • 김성찬
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.98-103
    • /
    • 2010
  • 본 연구는 화재실험에서 널리 이용되고 있는 노출비드형 열전대의 신뢰성을 평가하기 위해 화재실험을 수행하고 흡입식 열전대와 노출비드형 열전대에 의해 측정된 온도를 비교 분석한다. 화재실의 고온의 상층부에서는 노출비드형 열전대의 측정온도가 흡입식 열전대에 비해 상대적으로 낮게 나타났고 측정오차는 크지 않은 반면 저온의 하층부에서는 노출비드형 열전대의 온도가 높게 나타났으며 측정오차 또한 크게 증가하였다. 본 연구에서 측정된 노출비드형 열전대의 최대 상대오차는 최대 250% 이상까지 나타났으며 노출비드형 열전대를 이용하여 화재유동장을 정량화 할 때 측정 신뢰성 향상을 위해 적절한 보정과정이 필요함을 보여준다.

페놀수지로 몰딩된 바이메탈식 서모스탯의 발화위험성 (The Hazard of Ignition on the Bimetal Type Thermostat Molded by Phenol Resin)

  • 박영국;이승훈
    • 한국화재조사학회지
    • /
    • 제11권1호
    • /
    • pp.63-73
    • /
    • 2007
  • 페놀수지로 몰딩된 바이메탈식 서모스탯의 반복적인 동작에 의한 발화위험성을 검토하기 위하여 발화된 것으로 판정된 사례의 연구와 동작 횟수를 가속시킨 실험을 행하였다. 사례연구 및 실험결과, 페놀수지로 몰딩된 바이메탈식 서모스탯(이하 '바이메탈식 서모스탯'이라 칭함)은 반복적인 동작에 의하여 내측의 고정접점과 가동접점 부분 사이에서 몰딩재료인 페놀수지가 국부적으로 탄화되는 트래킹 현상이 발생되며, 이로 인한 전기적인 발열 및 용융 등에 의하여 내측으로부터 발화될 수 있다는 사실을 입증하였다.

  • PDF

모형 연소실에서 분사기 연소 안정성 평가에 관한 실험적 연구 (A Experimental Study on Combustion-Stability Rating in a Subscale Chamber)

  • 김철진;손채훈
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.77-78
    • /
    • 2012
  • To predict combustion instability in actual full-scale combustion chamber of rocket engines, air-injection test is proposed with scaling techniques. From the data, damping factors have been obtained as a function of hydraulic parameter and the data give us instability map. Two instability regions are presented and it is found that they coincide reasonably with them from hot-fire test with full-scale flow rates. Accordingly, the proposed approach can be applied cost-effectively to stability rating of jet injectors when mixing of fuel and oxidizer jets is the dominant process in instability triggering.

  • PDF

질소흡착법을 사용한 고온 가열 시멘트의 세공구조 측정 (Measurement of the construction structure of hot-heated cement using nitrogen adsorption method)

  • 김민혁;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.140-141
    • /
    • 2020
  • Concrete has a lower thermal conductivity or thermal diffusion coefficient compared to other building materials, so it is widely used as fireproof compartment material or refractory material for structures. However, in the event of thermal damage such as fire, cement curing agents and aggregates act differently, resulting in heat generation or deterioration of tissue due to dehydration, resulting in deterioration of physical properties and fire resistance. Therefore, in this study, the processing structure of cement paste is measured through nitrogen absorption method. The test specimen is a cement paste of 40% W/C and is set at 1000 ℃ under heating temperature conditions. As the temperature rose, the micro-pore mass below was reduced based on about 0.01 감소m, but the air gap above that was increased.Thus, in the range of pores measured in nitrogen adsorption, the air mass tended to decrease under high temperature conditions.

  • PDF

액체추진제 분해촉매 장기성능시험장치 개발 및 평가방안 (Development of Long-Life Performance Test Equipment & Evaluation Plan for Hydrazine Decomposition Catalyst)

  • 김인태;김정훈;이재원;장기원;유명종;김수겸;이균호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.407-412
    • /
    • 2006
  • 하이드라진을 이용한 단일추진제 추력기에서 촉매의 성능은 추력기 및 전체 시스템의 임무수명시간을 결정하는 가장 중요한 요소 중의 하나이다. 이러한 촉매의 개발과정에 필수적으로 요구되는 것이 추력기의 연소시험을 통한 성능평가 과정으로 특히, 촉매의 수명시험에 해당하는 장기성능 검증시험을 통해 그 적용가능성을 판단하게 된다. 본 연구에서는 이를 위한 시험장치의 개발 및 시험/평가방안에 대해 기술하였다.

  • PDF