• 제목/요약/키워드: Hot-Spot Temperature

검색결과 133건 처리시간 0.023초

A Study on the Hot Spot Temperature in 154kV Power Transformers

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Woo, Jung-Wook;Kwak, Joo-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.312-319
    • /
    • 2012
  • The life of a power transformer is dependent on the life of the cellulose paper, which influenced by the hot spot temperature. Thus, the determination of the cellulose paper's life requires identifying the hot spot temperature of the transformer. Currently, however, the power transformer uses a heat run test is used in the factory test to measure top liquid temperature rise and average winding temperature rise, which is specified in its specification. The hot spot temperature is calculated by the winding resistance detected during the heat run test. This paper measures the hot spot temperature in the single-phase, 154kV, 15/20MVA power transformer by the optical fiber sensors and compares the value with the hot spot temperature calculated by the conventional heat run test in the factory test. To measure the hot spot temperature, ten optical fiber sensors were installed on both the high and low voltage winding; and the temperature distribution during the heat run test, three thermocouples were installed. The hot spot temperature shown in the heat run test was $92.6^{\circ}C$ on the low voltage winding. However, the hot spot temperature as measured by the optical fiber sensor appeared between turn 2 and turn 3 on the upper side of the low voltage winding, recording $105.9^{\circ}C$. The hot spot temperature of the low voltage winding as measured by the optical fiber sensor was $13.3^{\circ}C$ higher than the hot spot temperature calculated by the heat run test. Therefore, the hot spot factor (H) in IEC 60076-2 appeared to be 2.0.

Winding Temperature Measurement in a 154 kV Transformer Filled with Natural Ester Fluid

  • Kweon, Dongjin;Koo, Kyosun
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.156-162
    • /
    • 2013
  • This paper measures the hot spot temperatures in a single-phase, 154 kV, 15/20 MVA power transformer filled with natural ester fluid using optical fiber sensors and compares them with those calculated by conventional heat run tests. A total of 14 optical fiber sensors were installed on the high-voltage and low-voltage windings to measure the hot spot temperatures. In addition, three thermocouples were installed in the transformer to measure the temperature distribution during the heat run tests. In the low-voltage winding, the hot spot temperature was $108.4^{\circ}C$, calculated by the conventional heat run test. However, the hot spot temperature measured using the optical fiber sensor was $129.4^{\circ}C$ between turns 2 and 3 on the upper side of the low-voltage winding. Therefore, the hot spot temperature of the low-voltage winding measured using the optical fiber sensor was $21.0^{\circ}C$ higher than that calculated by the conventional heat run test.

디스크 브레이크에서 접촉 마찰 진동이 열섬에 미치는 영향 연구 (A Study of Frictional Contact Vibration Influence on Hot Spot in Automotive Disk Brake)

  • 조후준;김명구;조종두
    • 한국자동차공학회논문집
    • /
    • 제15권1호
    • /
    • pp.154-161
    • /
    • 2007
  • Hot spot phenomenon that occurs, during judder vibration, is locally concentrated heat due to friction between brake disk and pad. It is important to understand the reason behind hot spot phenomenon, for reduction of judder vibration. In this experimental study, experiments were performed in accordance with rotation speed of brake disk, pressure of master cylinder and pad length for achieving different aspects of hot spot phenomenon. Temperature distribution of hot spot was obtained by using the infrared camera. As the hot spot occurred, vibration was measured and frequency analysis was performed. Finite element analysis of thermal deformation of disk was performed by using temperature distribution that was achieved by experimental results. And mode shapes of disk was analyzed by finite element analysis and compared with experimental results. It was observed that the excitation frequency band of frictional contact and frictional force mainly affects the hot spot phenomenon.

마찰식 브레이크의 미세 접촉면에 발생된 적열점 현상의 수치적 연구 (Numerical Study of Miro-Contact Surface Induced Hot Spots in Friction Brakes)

  • 김청균;조승현
    • Tribology and Lubricants
    • /
    • 제19권5호
    • /
    • pp.268-273
    • /
    • 2003
  • This paper presents hot spot behaviors on the rubbing surface of disk-pad type brake by using coupled thermal-mechanical analysis technique. The height of micro-asperity on the rubbing surface is usually 2∼3 ${\mu}$m in practical disk brakes. Non-uniform micro-contacts between the disk and the rigid friction pads lead to high local temperature distributions, which may cause the material degradation, and develop hot spots, thermal cracks, and brake system failure at the end for a braking period. The friction temperatures on the rubbing surface of disk brakes in which are strongly related to the hot spot and thermal related wears are rapidly concentrated on the micro-contact asperities during braking. The computed FEM results show that the contact stress, friction induced temperature and thermal strain are highly concentrated on the rubbing micro-contact asperities even though the braking speed and force are small during the braking period. This hot spot may directly produce the slippage and various thermal wears on the brake-rubbing surface.

FEM을 이용한 24MVA 몰드변압기의 Hot-spot 위치 분석 연구 (Analysis on the Hot-spot Temperature Location of a 24MVA Cast Resin Transformer by FEM)

  • 김영배;하정우;신판석
    • 조명전기설비학회논문지
    • /
    • 제26권9호
    • /
    • pp.26-32
    • /
    • 2012
  • This paper calculates the core and copper losses as heating sources of a 24MVA cast resin transformer, and analyzes the thermal distribution of the transformer to find out its hot-spot area by FEM program. Since the winding of the transformer is composed with many series and parallel circuits, the analyzing model of the winding is simplified and modelled by axi-symmetric domain. As the results, the maximum temperature is estimated by $137^{\circ}C$ in the upper part of the low-voltage winding. The maximum temperature has discrepancy of approximately $10^{\circ}C$, which is able to be considered as an acceptable error range in the design stage of power transformers. For the overall pattern of the temperature distribution is almost same as test results, the analyzing method can be a useful tool to find out a hot-spot area of the winding.

Computer Modeling of Hot Spot Phenomena in Ventilated Disk Brake Rubbing Surface

  • Kim, Chung-Kyun;Cho, Seung-Hyun;Ko, Young-Bae
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.229-230
    • /
    • 2002
  • This paper presents the hot spot behaviors on the rubbing surface of ventilated disk brake by using finite element method. The depth of asperities on the rubbing surface is usually $2-3\;{\mu}m$ so the real contact area is microscopically. Non-uniform contacts between the disk and the pads lead to high local temperatures, which may cause the material degradation, and develops hot spots, thermal cracking, and brake system failures at the end. High contact asperity flash temperatures in rubbing systems, which is strongly related to the hot spot. It was generally known that high temperature over about $700^{\circ}C$ may form martensite on the cast iron which is material for automotive disk brakes. In this paper, the contact stress, temperature distribution and strain have been presented for the specific asperities of real contact area microscopically by using coupled thermal-mechanical analysis technique.

  • PDF

The Effect of Thermal Concentration in Thermal Chips

  • Choo, Kyo-Sung;Han, Il-Young;Kim, Sung-Jin
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2449-2452
    • /
    • 2007
  • Hot spots on thin wafers of IC packages are becoming important issues in thermal and electrical engineering fields. To investigate these hot spots, we developed a Diode Temperature Sensor Array (DTSA) that consists of an array of 32 ${\times}$32 diodes (1,024 diodes) in a 8 mm ${\times}$ 8 mm surface area. To know specifically the hot spot temperature which is affected by the chip thickness and a generated power, we made the DTSA chips, which have 21.5 ${\mu}m$, 31 ${\mu}m$, 42 ${\mu}m$, 100 ${\mu}m$, 200 ${\mu}m$, and 400 ${\mu}m$ thickness using the CMP process. And we conducted the experiment using various heater power conditions (0.2 W, 0.3 W, 0.4 W, 0.5 W). In order to validate experimental results, we performed a numerical simulation. Errors between experimental results and numerical data are less than 4%. Finally, we proposed a correlation for the hot spot temperature as a function of the generated power and the wafer thickness based on the results of the experiment. This correlation can give an easy estimate of the hot spot temperature for flip chip packaging when the wafer thickness and the generated power are given.

  • PDF

PV모듈에서 태양전지와 Interconnect회로의 구성이 I-V특성과 Hot Spot에 미치는 영향 (The effect of I-V characteristic and hot-spot by solar cell and interconnection circuit in PV module)

  • 이진섭;강기환;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.241-246
    • /
    • 2008
  • In this paper, we analyze the I-V curve and hot-spot phenomenon caused by solar cells' serial and parallel connected circuit. The mis-match loss of parallel interconnection with low Isc string decrease lower than serially interconnected one and temperature caused by hot-spot does. Also, mis-match loss of parallel interconnection with low Voc string increase more than serially interconnected one. The string having low Voc happened hot-spot phenomenon when open circuit. The bad solar cell in string gives revere bias to good solar cell and make hot-spot phenomenon. If we consider the mis-match loss, when designing PV module and array. the efficiency of PV system might increase.

  • PDF

적층판으로 제작된 고온초전도 한류기에 발생한 국부적 열폭주 점에 대한 열응력 해석 (Thermal Stress Due to a Hot - Spot on the Laminated Plate in High Temperature Superconducting Fault Current Limiter)

  • 양경진;강기주
    • 대한기계학회논문집A
    • /
    • 제27권5호
    • /
    • pp.705-712
    • /
    • 2003
  • Analysis for the thermal stress distribution in the laminated plates containing a hot-spot(local heating region) is performed. It is assumed that the local heating region induces only mechanical stress by the thermal expansion but effect of the thermal conduction is neglected. The region is regarded equivalent to a homogeneous inclusion expanding in a laminated medium. As an example, Au/YBCO/Al$_2$O$_3$laminate which is often employed for High Temperature Superconducting Fault Current Limiter(HTS FCL) has been analyzed. Effects of heat input, thickness of each layer and the got spot size upon the stress distribution in the hot-spot have been investigated. For a constant heat generation into the hot-spot, as the thickness of the Al$_2$O$_3$substrate increases, the stress in the YBCO layer is peculiarly oscillated, and the curvature of laminate has a maximum at a certain thickness of the Al$_2$O$_3$.

메탄올 자열 개질 반응기에서의 온도제어 (Temperature Control in Autothermal Reforming Reactor)

  • 김송주;남지훈;이지태;김동현
    • Korean Chemical Engineering Research
    • /
    • 제45권1호
    • /
    • pp.12-16
    • /
    • 2007
  • Copper-Zinc Oxide를 촉매로 사용하는 메탄올 자열 개질 반응기의 온도제어 연구를 하였다. 반응기 hot-spot에서 1 cm 벗어난 지점의 반응기 내부 온도를 피제어변수로, 공기 유량을 조작변수로 사용하였다. 일차 시간 지연 모델을 얻었으며, 이로부터 IMC-PI 법을 적용하여 제어기 값을 구할 수 있었다. 이 제어기로 100시간 이상 개질 반응기 내부의 온도를 ${\pm}5^{\circ}C$ 내에서 제어할 수 있었다. 촉매활성의 저하로 인한 hot-spot 지점의 변화를 조사하여, 적응 제어의 설계에 이용할 수 있게 하였다.