• 제목/요약/키워드: Hot water energy consumption

검색결과 125건 처리시간 0.023초

태양열 온수 및 난방 일체형 복합시스템의 성능예측 (Performance Prediction of a Hot Water Supply and Panel Heating System with Solar Energy)

  • 한유리;박윤철
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.11-17
    • /
    • 2012
  • In this study, a simulation program was developed with heat transfer model in the thermal storage tank for a solar collector and burner combined heating and hot water supply system. Analysis was conducted with variation of operating condition and schedule to analyze performance of a hot water supply and panel heating system with a solar collector and burner combined thermal storage tank. The simulation program is divided two sections. One part is calculation of temperature variation of water which flows through the panel in the floor for heating of the residential house during 24 hours, and the other part is heat transfer calculation for the reaction time to get desired water temperature in the thermal storage tank. As results, light oil consumption and system performance during operation period were analyzed with variation of climate condition and with or without solar collector. Most of the case, oil could be saved about from 24 to 41% with installing the solar collector. The performance of the system is more dependent on radiation time of the solar collector rather than the intensity of the solar radiation which was adopted for the climate analysis.

저온온수 모세유관 바닥복사 난방시스템의 성능에 관한 실험적 연구 (Experimental Study on a Low-Temperature Hot Water Capillary Radiant Floor Heating System)

  • 조진균;박병용;이용준;정원호
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.68-82
    • /
    • 2018
  • Radiant floor heating systems with capillary tubes are energy saving systems in which hot water is circulated into capillary tube with a small diameter. In this study, the heating performance of capillary tube system is investigated in an experimental study and a simulation model. The results of the study showed that, the capillary tube radiant floor heating system maintains a more stable floor surface temperature in comparison a PB pipe system. In terms of energy consumption, the capillary tube radiant floor heating system proved to be more efficient than the PB pipe heating system at $40^{\circ}C$ of low temperature hot water supply. The difference between water temperature and room temperature can be held low for heating which saves energy. Low temperature radiant floor heating system with capillary tubes have significant advantages such as health improvement, low energy cost, optimum use of heat source(boiler) and higher operational efficiency.

업무용 건물의 에너지 부하 모델 (Building Energy Demand Models for Offices in Korea)

  • 박화춘;정모
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.1-7
    • /
    • 2009
  • Energy demands for offices in Korea are surveyed and analyzed to generate communicational models for simulations. Daily energy loads of 13 office buildings scattered in the 6 largest cities in the country are surveyed and analyzed based on energy consumption log sheets. Detailed hourly loads that are frequently required when a detailed operation simulation is performed are measured using remote data acquisition processes for 3 offices. The complete load demand models of electricity, cooling, heating and hot water are established by combining the daily and hourly patterns based on the statistical behavior of the hourly patterns.

친환경 농촌마을계획을 위한 재생에너지 활용방안 연구 - 태양에너지 자원분석 - (A Study on Application of New & Renewable Energy for Environmental-friendly Planning of Rural Villages - Analysis of Solar Energy Resources -)

  • 남상운;김대식
    • 한국농공학회논문집
    • /
    • 제50권3호
    • /
    • pp.105-112
    • /
    • 2008
  • Solar energy, which is one of renewable energy, would be the most useful resources that can be applied to making energy recycling villages without using fossil energy. This study analyzed energy potential on solar energy considering weather condition in three traditional villages and compared with energy consumption surveyed. A photovoltaic system having 3.0kWp capacity of unit module can generate 182.5%, 96.1% and 170.9% of the yearly mean consumption of electric power in Makhyun, Boojang, and Soso, respectively. A flat-plate solar collector having $2.64m^2$ area of unit module can generate warm water of $142{\ell}$/day, $89{\ell}$/day, and $173{\ell}$/day, respectively in three study villages. In Makhyun and Soso, photovoltaic power and warm water produced by solar energy were sufficient to supply required amount of electric power and warm water. However, both electric power and warm water produced by unit solar module were not sufficient in Boojang area, and so it is required to increase the module area by more than 50%. According to the results of this study, the appropriate combination of energy resources can be applied to rural green-village planning if the characteristic of energy potential for each local area is considered.

임대아파트 난방방식별 에너지소비와 만족도 조사에 관한 연구 (A Study on the Energy Consumption and the Degree of Satisfaction by Heating System in Rental Apartment)

  • 박민용;장승재
    • 한국주거학회논문집
    • /
    • 제14권3호
    • /
    • pp.85-92
    • /
    • 2003
  • Considering the present development situation of rental apartment since 1982, the supply of homeless housing for low-income dwellers has contributed a amount of quantities, but has been deficient qualities in housing policy. To propose the energy policy for low-income dwellers, this study investigated the energy consumption and the degree of heating satisfaction by heating system through questionaries in permanent rental apartment and 50 year period rental apartment complexes. The results of this study were as follows; The annual energy consumption of heating and hot water supply is 267.2 Mca1/$\textrm{m}^2$ㆍyr in central heating system, is 163.9 Mca1/$\textrm{m}^2$ㆍyr in unit heating system. But from the view of annual energy cost and the degree of heating satisfaction, central heating system were better than unit heating system in rental apartment.

국의 온도가 공복감, 열량 및 영양소 섭취량에 미치는 영향 (Effects of Soup Temperature on Hunger, Energy and Nutrient Intake)

  • 김석영;장희애;김주영;박경민
    • Journal of Nutrition and Health
    • /
    • 제36권8호
    • /
    • pp.859-869
    • /
    • 2003
  • The purpose of this study was to compare the effects of soup temperature on hunger, energy, and nutrient intake. The hot meal consisted of 400 g of hot beef-vegetable soup (75$^{\circ}C$), Yubu Chobap, Bulgogi, cucumber pickle and radish pickle. The cold meal component were the same as the hot meal except 300 g of water (8$^{\circ}C$) and boiled vegctables (100 g), instead of the hot beef-vegetable soup ot the hot meal. Thirst, core temperature and blood pressure were also measured before and after consumption the test meals in a within-subjects, repeated measures design. 30 women consumed 17% more kilocalories, 13% more protein and lipid and 16% more carbohydrate in the cold meal than in the hot meal. The core temperature at the end of the test meal was higher in the hot meal than in the cold meal. Energy and nutrient intake were inversely correlated with the hunger scores within 1 hour after the hot meal, however those are not related with each other in the cold meal. So hunger feeling might be disturbed in the cold meal. It is concluded that energy and nutrient consumptions were higher in the cold meal, partly because of the distrubed hunger feeling in the cold meal.

지붕대체형 집광집열기를 이용한 태양열 난방시스템의 동절기 성능 평가 (A Study on the Field Test of the Solar Heating System with Parabolic Solar Collectors Integrated the Roof of a Residential Building)

  • 김용기;이태원;윤광은
    • 한국태양에너지학회 논문집
    • /
    • 제27권2호
    • /
    • pp.61-69
    • /
    • 2007
  • The final energy consumption in the building sector in Korea represents almost 20% of the total energy consumption. Besides, Space heating and hot water generation in Korea are based on fossil fuels, with a serious environmental impact. Despite the popularity of simple solar domestic hot water systems, active solar space heating remains, for various reasons, marginal. And thus, the aim of this paper is to demonstrate potentialities of solar assisted space heating systems, both technically and economically. From this study found that the solar heating system with CPC solar collectors integrated the roof of a single-story residential building shares $50{\sim}55%$ of the annual heating load.

Should Workers Avoid Consumption of Chilled Fluids in a Hot and Humid Climate?

  • Brearley, Matt B.
    • Safety and Health at Work
    • /
    • 제8권4호
    • /
    • pp.327-328
    • /
    • 2017
  • Despite provision of drinking water as the most common method of occupational heat stress prevention, there remains confusion in hydration messaging to workers. During work site interactions in a hot and humid climate, workers commonly report being informed to consume tepid fluids to accelerate rehydration. When questioned on the evidence supporting such advice, workers typically cite that fluid absorption is delayed by ingestion of chilled beverages. Presumably, delayed absorption would be a product of fluid delivery from the gut to the intestines, otherwise known as gastric emptying. Regulation of gastric emptying is multifactorial, with gastric volume and beverage energy density the primary factors. If gastric emptying is temperature dependent, the impact of cooling is modest in both magnitude and duration (${\leq}5$ minutes) due to the warming of fluids upon ingestion, particularly where workers have elevated core temperature. Given that chilled beverages are most preferred by workers, and result in greater consumption than warm fluids during and following physical activity, the resultant increased consumption of chilled fluids would promote gastric emptying through superior gastric volume. Hence, advising workers to avoid cool/cold fluids during rehydration appears to be a misinterpretation of the research. More appropriate messaging to workers would include the thermal benefits of cool/cold fluid consumption in hot and humid conditions, thereby promoting autonomy to trial chilled beverages and determine personal preference. In doing so, temperature-based palatability would be maximized and increase the likelihood of workers maintaining or restoring hydration status during and after their work shift.

TRNSYS 프로그램을 이용한 대형쇼핑매장 에너지성능해석 및 지열시스템을 도입하는 경우 에너지절약 특성분석 (Analysis of Energy Performance & Energy Saving with Geothermal Heat Pump System Using TRNSYS Program in a Large Scale Shopping Store)

  • 홍원표
    • 조명전기설비학회논문지
    • /
    • 제29권1호
    • /
    • pp.47-56
    • /
    • 2015
  • Energy consumption in buildings is currently a real problem. That is why both assessment of energy performance and effective energy management including renewable energy system are essential. Thus, this paper focuses on a case study to analyze the energy performance and cooling & heating energy saving of a large scale shopping store in Daejeon city. The reference building is simulated by using TRNSYS dynamic simulation tool to examine its annual energy consumption. For annual energy analysis of building, one year energy consumption is surveyed in the field. The related study is carried out in large scale shopping store to investigate the energy consumption and energy use trend of heating, cooling, hot water, lighting, ventilation, equipments and other. The evaluation of energy performance of the geothermal heat pump system installed in a large scale shopping store is also analyzed by TRNSYS tool. From simulation results, it evaluated that the geothermal heat pump system is effective energy savings method in large scale shopping store.

친환경주택평가기법개발 및 지원방안에 관한 연구 (Development of an Evaluation Method and Support Policy for the Green Home Project)

  • 이종성;유정현;임주호;김효진
    • 토지주택연구
    • /
    • 제1권1호
    • /
    • pp.27-34
    • /
    • 2010
  • 본 연구에서는 그린 홈의 보급확대와 평가기법 개발을 목적으로 하고 있다. 구체적으로는 기 조사된 실측 데이터를 기본으로 시뮬레이션 결과 값의 보간 및 설비시스템의 교체에 따른 효과 검토를 통하여 에너지 절감량 및 이산화탄소 배출 삭감량 평가 프로그램을 개발하였다. 또한, 그린 홈의 보급확대에 따른 비용 검토를 통하여 그린홈을 건설하는 사업자에게는 지방세법 개정에 따른 취등록세 감면 등의 지원대책을 수립하였다.