• Title/Summary/Keyword: Hot plate

Search Result 690, Processing Time 0.03 seconds

Inhibitory Effects of Poturaca oleracea L. Extract on the Mutagenicity of Various Mutagen (각종 변이원에 대한 쇠비름 추출물의 돌연변이 억제 효과)

  • 최근표;정성원;김은정;함승시
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.7 no.4
    • /
    • pp.527-537
    • /
    • 1997
  • This study was performed to determine the effects of antimutagenicity of Porturaca oleracea L. in Korea. In Ames test, the ethanol extract of Poturaca oleracea L. inhibited mutagenic activity of N-methyl-N'-nitro-N-nitrosoguanidine(MNNG), , 4-nitroquinoline-1-oxide(4NQO), benzo($\alpha$)pyrene (B($\alpha$)P) and 3-amino-1,4-dimethyl-5H-pyrido-(4,3-b)indole (Trp-P-1) in Salmonella typhimurium TA98 and TA100. But hot-water extract Poturaca oleracea L. only Inhibited mutagenic activity of MNNG in Salmonella typhimurium TA100, On 4NQO, the ethanol extract 100-1,600$\mu\textrm{g}$/plate of Porturaca oleracea L. showed a slight inhibitory effect of 13-48%, 4-47% in TA98 and TA100, respectively, but on MNNG, it showed higher inhibitory effect of 6-86% in TA100, And the treatment of 1,600$\mu\textrm{g}$/plate of ethanol extract of Porturacea L. had strong antimutagenicity with 74-87% inhibition against TA98 and TA100 induced by B(a)P and with 85-93% inhibition against TA98 and TA100 induced by Trp-P-1. The ethanol extract was fractionated with ether. chloroform, ethylacetate, butanol and water. Among them, most of the fraction except water fraction showed strong antimutagenicity effects against mutation induced by 4-NQO, MNNG, B(a)P and Trp-P-1. Chloroform fraction had strong antimutagenicity with 91% inhibition against TA100 induced by MNNG, diethyl etherfraction had strong antimutagenicity with 92%, 98% inhibition against TA98 and TA100 induced by 4NQO, Chloroform fraction had strong antimutagenicity with 97% inhibition against TA100 induced by B (a)P and diethyl etherfraction had strong antimutagenicity with 98% inhibition against both strain Induced by Trp-P-1, respectively.

  • PDF

A Study on the Flow Characteristics of the Catalytic Combustor for the Gas Turbine (가스터빈용 촉매 연소기의 유동 특성에 관한 연구)

  • Hong, Dong-Jin;Kim, Chong-Min;Kim, Man-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.9
    • /
    • pp.792-798
    • /
    • 2007
  • catalytic combustion is accomplished by the chemical reaction between fuel and oxidizer at the catalyst surface, different from conventional combustion. Therefore, it is important that the fuel and air stream are well mixed and supplied uniformly prior to the combustion region. If the flow is maldistributed, a hot spot may occur that can lead to subsequent catalyst and substrate damage. Therefore, in order to enhance the mixing and flow uniformity, in this study, the perforated plate is used. A numerical simulation is performed to investigate the variation of flow characteristics by changing various parameters. Under each condition, the uniformity of the flow stream at the entrance of the catalyst section is evaluated and compared. The results show that the uniformity can be effectively improved for most of the case by using the well-designed perforated plates.

Analgesic activity of three Channa spp. fish extracts

  • Solihah, MH;Israf, DA;Zuraini, A;Arifah, AK;Zakaria, MS;Zakaria, ZA;Sulaiman, MR;Jais, AM Mat;Somchit, N
    • Advances in Traditional Medicine
    • /
    • v.6 no.4
    • /
    • pp.349-354
    • /
    • 2006
  • In the present study, three Malaysian Channa spp. fish Channa striatus, Channa micropeltes and Channa lucius were assessed for their analgesic activity. Distilled water and mixture of chloroform: methanol were used for extraction. The analgesic or antinociceptive activity was investigated by abdominal writhing and hot plate test. The water extract of Channa striatus and the chloroform: methanol extract Channa lucius produced potent antinociceptive effect when assessed with the abdominal writhing test. The activity was compared to morphine where the activity of the extracts was less potent than the opioid. In the hote plate test, water extract of Channa striatus revealed significant activity and chloroform:methanol extract of Channa micropeltes had moderate activity. However, these activities were statistically lower than morphine. Collectively, this study also showed that Channa striatus extract was more potent analgesic agent when compared to the other closely related snakehead Channa micropeltes and Channa lucius.

A Survey on the Sanitary Condition of Foods and Water of Street Food Carts (포장마차 음식의 위생 실태 조사연구)

  • 김종규
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.107-114
    • /
    • 2001
  • The number of covered carts selling snack foods along the streets are increasing in Korea and people enjoy eating foods at these carts. However there are only a few reports on the contamination or sanitary condition of the food carts. This study was performed to investigate the sanitary condition of food and water at the street food carts in the eight major areas of a city. Water and several kinds of food, kimbop(laver rollers) ddeokbokki(stir fried rice cake in hot pepper paste) oemuk(fish cakes) fish cake soup, and soy sauce were collected from four street carts from each of the 8 areas from June to August in 2001 The standard plate counts(SPCs) and coliform groups were examined according to the Food Code of Korea. The nufitness rates of SPCs of the samples were 0~15.6%: 15.6% in kimbop:6.3% in fish cake soup; and 3.1% in water samples SPCs were not detected in some samples. of ddeokbokki, oemuk and soy sauce. The unfitness rates of coliform groups were 0~62.5%; 46.9% in kimbop; 6.3% in ddeokbokki,;22.9% in oemuk 62.5% in fish cake soup; and 3.1% in soy sauce. Coliform groups were not detected in water sample The numbers and unfitness rates of SPCs and coliform groups showed increasing tendencies over time within a day. The higher the air temperature was the more increase of bacteriological growth was observed These results indicate that the level of bacteriological contamination of foods and water in the street carts should be monitored and strict inspection is necessary. There should be legal consequences for serving contaminated food to the public.

  • PDF

Heating Performance Characteristics of Heat Pump with VI cycle using Re-Heater and Solar-Assisted (태양열과 재열기를 사용한 VI heat pump의 성능 특성에 관한 연구)

  • Lee, Jin-Kook;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.6
    • /
    • pp.25-33
    • /
    • 2015
  • In this study, heating performance of the air-cooled heat pump with vapor-injection (VI) cycles, re-heater and solar heat storage tank was investigated experimentally. Devices used in the experiment were comprised of a VI compressor, re-heater, economizer, variable evaporator, flat-plate solar collector for hot water, thermal storage tank, etc. As working fluid, refrigerant R410A for heat pump and propylene glycol (PG) for solar collector were used. In this experiment, heating performance was compared by three cycles, A, B and C. In case of Cycle B, heat exchange was conducted between VI suction refrigerant and inlet refrigerant of condenser by re-heater (Re-heater in Fig. 3, No. 3) (Cycle B), and Cycle A was not use re-heater on the same operating conditions. In case of Cycle C, outlet refrigerant from evaporator go to thermal storage tank for getting a thermal energy from solar thermal storage tank while re-heater also used. As a result, Cycle C reached the target temperature of water in a shorter time than Cycle B and Cycle A. In addition, it was founded that, as for the coefficient of heating performance($COP_h$), the performance in Cycle C was improved by 13.6% higher than the performance of Cycle B shown the average $COP_h$ of 3.0 and by 18.9% higher than the performance of Cycle A shown the average $COP_h$ of 2.86. From this results, It was confirmed that the performance of heat pump system with refrigerant re-heater and VI cycle can be improved by applying solar thermal energy as an auxiliary heat source.

Effects of Rubber Loading on the Ultrasonic Backward Radiation Profile of Leaky Lamb Wave (고무 접합이 후방복사된 리키 램파 프로파일에 미치는 영향)

  • Song, Sung-Jin;Kwon, Sung-Duk;Jung, Min-Ho;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.508-515
    • /
    • 2002
  • The characterization of adhesive property in multi-layer materials has been hot issue for a long time. In order to evaluate adhesive properties, we constructed fully automated system for the backward radiation of leaky Lamb wave. The backward radiation profiles were obtained for the bare steel plate and plates with rubber-loading. The rf waveforms and frequency spectra of backward radiation show the characteristics of involved leaky Lamb wave modes. As the thickness of rubber-loading increased, the amplitude of profile at the incident angle of $13.4^{\circ}$ exponentially decreased. Scanning the incident position over the partially rubber-loaded specimen shows good agreement with the actual rubber-loading. The backward radiation of leaky Lamb wave has great potential to evaluate the adhesive condition as well as material properties of plates.

Acoustical Similarity for Small Cooling Fans Revisited (소형 송풍기 소음의 음향학적 상사성에 관한 연구)

  • 김용철;진성훈;이승배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.196-201
    • /
    • 1995
  • The broadband and discrete sources of sound in small cooling fans of propeller type and centrifugal type were investigated to understand the turbulent vortex structures from many bladed fans using ANSI test plenum for small air-moving devices (AMDs). The noise measurement method uses the plenum as a test apparatus to determine the acoustic source spectral density function at each operating conditions similar to real engineering applications based on acoustic similarity laws. The characteristics of fans including the head rise vs. volumetric flow rate performance were measured using a performance test facility. The sound power spectrum is decomposed into two non-dimensional functions: an acoustic source spectral distribution function F(St,.phi.) and an acoustic system response function G(He,.phi.) where St, He, and .phi. are the Strouhal number, the Helmholtz number, and the volumetric flow rate coefficient, respectively. The autospectra of radiated noise measurements for the fan operating at several volumetric flow rates,.phi., are analyzed using acoustical similarity. The rotating stall in the small propeller fan with a bell-mouth guided is mainly due to a leading edge separation. It creates a blockage in the passage and the reduction in the flow rate. The sound power levels with respect to the rotational speeds were measured to reveal the mechanisms of stall and/or surge for different loading conditions and geometries, for example, fans installed with a impinging plate. Lee and Meecham (1993) studied the effect of the large-scale motions like impinging normally on a flat plate using Large-Eddy Simulation(LES) and Lighthill's analogy.[ASME Winter Annual Meeting 1993, 93-WA/NCA-22]. The dipole and quadrupole sources in the fans tested are shown closely related to the vortex structures involved using cross-correlations of the hot-wire and microphone signals.

  • PDF

A NUMERICAL STUDY ON THE FLOW AND HEAT TRANSFER CHARACTERISTICS OF A HEAT EXCHANGER HAVING RECTANGULAR PIN-FINS SLANTED IN THE FLOW DIRECTION (유동 방향으로 기울어진 사각 핀-휜 열교환기의 유동 및 열전달 특성에 대한 수치적 연구)

  • Seo, J.H.;Kim, M.;Ha, M.Y.;Min, J.K.
    • Journal of computational fluids engineering
    • /
    • v.21 no.3
    • /
    • pp.98-109
    • /
    • 2016
  • The flow and heat transfer characteristics of a heat exchanger having rectangular pin-fin in the flow direction have been investigated numerically. On the bottom plate, the convective boundary conditions for the hot side was given, and the fins were arranged in a channel-type geometric model using the periodic boundary condition in the span-wise direction. Three-dimensional numerical calculations for the flow and conjugate heat transfer problem were conducted using SIMPLE algorithm and $k-{\varepsilon}$ turbulence model. For the slanted pin-fin models, it was found that the downward cooling flow is generated due to the downward pressure gradient component, which can enhance the heat transfer performance near the bottom surface and the fin stem region. Four different inclined angles were considered in the Reynolds number range of 13,500-55,000. The aero-thermal performance of the slanted pin-fin heat exchangers, such as the volume and area goodness factors, were summarized and compared with the baseline plate-fin type heat exchanger quantitatively.

QUALITY OF KOREAN GINSENG DRIED WITH A PROTOTYPE CONTINUOUS FLOW DRYER USING FAR INFRARED RAY AND HEATED-AIR

  • Park, S. J.;Kim, S. M.;Kim, M. H.;Kim, C. S.;Lee, C. H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.388-395
    • /
    • 2000
  • This study was performed to examine the effects of infrared (IR)/heated-air combination drying on some quality attributes of Korean white ginsengs. Ginseng roots were dried in a dryer where both the far infrared ray and heated-air are available as drying energy sources. Diametral shrinkage, external color, total saponin content, and ginsenosides and free sugar composition of the IR/heated-air combination dried ginsengs were measured and compared with those of commercial white ginseng products. The external color became lower in lightness and higher in saturation as the IR radiating plate temperature increased. IR/heated-air combination dried white ginsengs at IR plate temperature of 100$^{\circ}C$ was comparable to the commercial white ginseng products in color characteristics. Diametral shrinkage ratios ranged from 20 to 36% and appeared to be independent on the different drying methods. No definite evidence could be found whether the IR/heated-air combination drying and the conventional. hot-air drying practice resulted in white ginsengs having different ginsenoside contents and compositions. No conclusion could be made on whether the various drying treatments used in the study had effects on the free sugar contents and compositions of white ginsengs.

  • PDF

Effect of Working Fluids on the Thermal Behavior of a Bi-directional Solar Thermal Diode (작동유체가 양방향성 태양열 열다이오드의 열성능 변화에 미치는 영향 분석)

  • Ko, Yung-Joo;Lee, Heon-Ju;Chun, Won-Gee;Chen, Kuan;Lim, Sang-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.9-17
    • /
    • 2008
  • An experimental investigation has been carried out to study the effects of different working fluids on the behavior and thermal performance of a hi-directional thermodiode. The thermodiode was made up of two rectangular loops mounted between a collector plate and a radiator plate. Rotatable joints between the horizontal and inclined segments of the loops enable easy alteration of the direction of heat transfer. The loops and the tank were filled with a working fluid for effective heat transfer when the thermodiode was forwarded biased. Six different working fluids were tested with thermal conductivity values ranging from 0.1 to $0.56W/m-^{\circ}C$, thermal expansion coefficient values ranging from $1.8\;{\times}10^{-4}$ to $1.3\;{\times}\;10^{-3}\;K^{-1}$, and kinematic viscosity values ranging from $0.65\;{\times}\;10^{-6}$ to $100\;{\times}\;10^{-6}\;m^2/s$. Especially, mixtures of $Al_2O_3$ (30nm Particle) in deionized water have been tested for the volumetric ratios of 0.01, 0.02, 0.03, 0.1, 0.2%. Each experiment was carried out after the loop was filled with a working fluid for effective heat transfer and the thermodiode was forwarded biased. The solar thermodiode was heated by a radiant heater consisting of 20 halogen lamps that generated a heat flux of about $1000\;W/m^2$ on the collector surface. Results are given in terms of temperature development in different parts of the loop as heat is delivered from its hot end to the surrounding atmosphere by the radiator made of copper plates.