• 제목/요약/키워드: Hot plate

검색결과 690건 처리시간 0.034초

분무냉각에 의한 강판 열처리과정에 있어서 열전달분포의 측정 (Measurements of Heat Transfer Distribution in Spray Cooling of Hot Steel Plate .)

  • 김영찬;유갑종;서태원
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.886-893
    • /
    • 2000
  • A good understanding of the heat transfer distribution is very important to suppress the deformation of steel products. In this study, the local heat transfer coefficients are experimentally investigated to understand the heat transfer distribution of thick steel plates with even flat spray nozzle. The steel slabs are cooled down from the initial temperature of about $1000^{\circ}C$ , and the local heat transfer coefficients and surface temperatures are calculated from the measured temperature-time history. The results show that the local heat transfer coefficients of spray cooling are dominated by the local droplet flow rate, and in proportion to becoming more distant from the center of heat transfer surface, the local heat transfer coefficients decrease with the decrease of the local droplet flow rate.

  • PDF

Benorylate와 Ethoxybenzamide 밍 Lorazepam 과의 상호작용 (Benorylate Interaction with Ethoxybenzamide and Lorazepam)

  • 허인회;이명환
    • 약학회지
    • /
    • 제23권1호
    • /
    • pp.11-16
    • /
    • 1979
  • Benorylate and ethoxybenzamide have been used alone or in combination as an analgesic, antipyretic and antiinflammatory agent. We investigated the significance of the differences of analgesic activities between single and concurrent administration of benorylate and ethoxybenzamide and lorazepam in mice and also antipyretic activity between single and concurrent administration of benorylate and ethoxybenzamide in rats. 1). Concurrent administration of each half dose of benorylate and ethoxybenamide showed much inhibiting effect on the acetic acid-induced writhing syndrome of mice than the above drug alone, and the some increased analgesic response by hot plate method. 2). The synergistic and analgesic effect of combined administration of benorylate and lorazepam was found to be significant. 3). Antipyretic effect of half-dose combined administration of benorylate and ethoxybenzamide on the rat pyrexia induced by yeast(s.c.) and T.T.G. (i.v.) was shown to be similar to the effect of each drug.

  • PDF

Some pharmacological findings of non therapeutic importance of an Ayurvedic preparation Chandanasav

  • Chakraborty, Sharmila;Rajia, Sultana;Choudhuri, M. Shahabuddin Kabir;Hossain, M. Faruk;Sattar, Mafruhi;Shrestha, Tripti
    • Advances in Traditional Medicine
    • /
    • 제6권2호
    • /
    • pp.157-160
    • /
    • 2006
  • Chandanasav is an Ayurvedic preparation slightly reduced the gastrointestinal motility at the 15 min time interval. It increased the latent period of castor oil induced diarrhoea, slightly decreased number of stool count and lowered the purging index values. Chandanasav significantly reduced the onset and increased the duration of pentobarbital induced sleeping time. No significant analgesic effect was observed from the hot plate study Thus it may have mild constipating and central nervous system depressant activity without any effect on peripheral nervous system.

Facile mass production of thermally reduced graphene oxide

  • Lee, Seung-Jun;Park, Sung-Jin
    • Carbon letters
    • /
    • 제13권1호
    • /
    • pp.48-50
    • /
    • 2012
  • Mass production of graphene-based materials, which have high specific surface area, is of importance for industrial applications. Herein, we report on a facile approach to produce thermally modified graphene oxide (TMG) in large quantities. We performed this experiment with a hot plate under environments that have relatively low temperature and no using inert gas. TMG materials showed a high specific surface area (430 $m^2g^{-1}$). Successful reduction was confirmed by elemental analysis, X-ray photoelectron spectroscopy, thermogravimetic analysis, and X-ray diffraction. The resulting materials might be useful for various applications such as in rechargeable batteries, as hydrogen storage materials, as nano-fillers in composites, in ultracapacitors, and in chemical/bio sensors.

희박 분무영역에서의 분무냉각 막비등 열전달에 관한 연구 (Study on Film Boiling Heat Transfer of Spray Cooling in Dilute Spray Region)

  • 김영찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1481-1486
    • /
    • 2004
  • This report presents experimental results on the heat transfer coefficients in the boiling region of spray cooling for actual metallurgical process. In this study, the heat flux distribution of a two dimensional dilute spray impinging on hot plate was experimentally investigated. Based on the experimental results, they classified the heat transfer area into the stagnation region and wall-flow region. In the stagnation region, the local heat transfer coefficient relates mainly to the droplet-flow-rate supplied from spray nozzle directly, so the local heat transfer coefficients is good agreement with the predicted values from correlation for spray cooling proposed by former report However, the local heat transfer coefficient in wall-flow region is larger than predicted values, and it is found that the rebounding droplets-flow-rate must be accurately evaluated to predict the local heat transfer coefficient in this region.

  • PDF

온수, 증기 동시 발생형 가스엔진 열병합발전의 배열회수 특성: 100 kW급 모형 실험 (Heat Recovery from a 1 MW Class Gas Engine CHP System: 100 kW Class Model Test)

  • 안준;김혁주;최규성;송대석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.345-350
    • /
    • 2008
  • The present study has been conducted to develop a heat recovery system for a 1 MW class gas engine based cogeneration system. In the cogeneration system, heat is recovered from two parts, which are jacket water and exhaust gas. The heat from the jacket water is recovered by a plate type heat exchanger and used for the room heating and/or hot water supply. The heat from the exhaust gas is used to generate steam. For both of the heat recovery devices, 1/5 scaled tests are performed and the data are compared to the conventional correlations for the design.

  • PDF

Antinocicepetive Effects of 3,4-Dicaffeoyl Quinic Acid of Ligularia fischeri var. spiciformis

  • Choi, Moo-Young;Park, Hee-Juhn
    • 한국자원식물학회지
    • /
    • 제20권3호
    • /
    • pp.221-225
    • /
    • 2007
  • The plant Ligularia fischeri var. spiciformis (Compositae) is a candidate for available functional foods. It has been used to treat diabetes mellitus and rheumatoid arthritis. We have reported the isolation of a new eremophilanolide named 6-oxoeremophilenolide and cytotoxic intermedeol together with the isolation of hydrophilic constituents, chlorogenic acid, 3,4-di-O-caffeoylquinic acie (3), and 5-O-[1-butyl]-3,4-di-O-caffeoylquinic acid. Compound 3 was again isolated by combination of silica gel- and ODS column chromatography for the anti-nociceptive action. Compound 3 and 4 were assayed in hot plate- and writhing tests in the rat. Although the three derivatives of caffeic acid exhibited significant anti-nociceptive effects at 10 mg/kg dose (i.p.),(activity potency: 4>3). These results suggest that compound 3 is responsible for at least rheumatoid arthritis, and caffeic acid moiety is the active moiety of dicaffeoylquinic acid.

열전냉각소자와 열전발전소자의 발전특성 (Characteristics of electric power for thermoelectric cooling & generating module)

  • 우병철;이희웅;이동윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.448-451
    • /
    • 2000
  • The purpose of this study is to manufacture and test a thermoelectric generator which converts unused energy from close-at-hand sources, such as garbage incineration heat and industrial exhaust, to electricity. A manufacturing process and the properties of a thermoelectric generator are discussed before simulating the thermal stress and thermal properties of a thermoelectric module located between an aluminum tube and alumina plate. We can design the thermoelectric modules having the good properties of thermoelectric generation. Resistivity of thermoelectric module for thermoelectric generation consisting of 62 cells was 0.15-0.4$\Omega$ Developed thermoelectric modules can be expected th have better properties than thermoelectric cooling modules above $70^{\circ}C$ in temperature difference between hot and cold ends.

  • PDF

고분자 필름의 두께변화에 따른 Bi-Te계 열전모듈의 열분포 특성 (Thermal Distribution of Bi-Te Thermoelectric Module with the thickness of Polymer Sheet)

  • 변종보;김봉서;박수동;이희웅;김영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1675-1677
    • /
    • 2005
  • In case of attaching thermoelectric module and heat source, the polymer sheet is attached on the $AL_{2}O_3$ plate, which Is cold and hot side of thermoelectric module, in order to enhance mechanical safty of the system. It is impossible to calculate the exact distribution of temperature and flow pattern of inner gap of thermoelectric module. Therefore CFD(Computational Fluid Dynamics) analysis was executed to determine the thermo-fluid phenomena and distribution by Fluent. As the result of these analysis, heat transfer was dominated by conduction and the difference of temperature was linear distribution according to the thickness of polymer sheet.

  • PDF

평면제트를 이용한 충돌면에서의 난류유동 특성 (Turbulent Flow Characteristics using Plane Jet on Impingement Surface)

  • 윤순현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권4호
    • /
    • pp.429-435
    • /
    • 1998
  • Experiments were conducted to investigate the turbulent flow characteristics from on oblique impingement surface to an plane jet at the jet Reynolds number(Re based on the nozzle width) $3{\times}10^4$ The jet mean velocity and turbulent intensity profiles have been measured along the impingement surface by hot-wire anemometer. The nozzle-to-plate distance(H/B) ranged from 2 to 10 and the oblique angle (a) from 45 to 90 degree. Also the secondary peak of the turbulent intensity was observed at H/B=4 S/B 5 and a=90 degree. It has been found that the stagnation point shifted toward the minor flow region as the oblique angle decreased and the position of the stagnation point nearly coincided with that of the maximum turbulent intensity.

  • PDF