Isolation and Identification of Legionella pneumophila from Hot Water Spouts and Hot Water (溫水수도꼭지와 온수에서 Legionella pneumophila의 分離同定)

  • Park, Ju-Hyeong;Zong, Moon-Shik
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.1
    • /
    • pp.23-32
    • /
    • 1988
  • A study was carried out to find distribution of Legionella spp. in hot water supplying systems of buildings in Seoul. Water samples were taken from the hot water taps in three research institute buildings during the period from the 2nd to 27th February, 1987. And all of the three buildings were supplied with hot water from the same central hot water tank. GVPC BCYEa and blood agar were used for the isolation of Legionella pneurnophila and slide agglutination test (SAT) was performed to identify their strain types. Main findings were as follows 1. 44 samples taken from hot tap-water revealed 20% of positive culture and 44 samples taken from hot water spouts revealed 11% of positive culture. 2. The 78% of positive samples taken from hot water was obtained from 25.1$\circ$C~45.0$\circ$C temperature range. 3. Only, Legionella pneumophila serogroup 3 was identified and most of them has been than 2$\mu$m in length. 4. The densities of the Legionella pneurnophila isolated from hot water samples were within the range of $1.0\times 10^2$ to $1.1\times 10^3$ CFU/l and their densities isolated from hot water spouts were either 1 CFU/plate or 2 CFU/plate.

  • PDF

Photoactive Layer Formation with Oven Annealing for a Carbon Electrode Perovskite Solar Cell

  • Kim, Kwangbae;Song, Ohsung
    • Korean Journal of Materials Research
    • /
    • v.30 no.11
    • /
    • pp.595-600
    • /
    • 2020
  • The photovoltaic properties of perovskite solar cells (PSCs) with a carbon electrode fabricated using different annealing processes are investigated. Perovskite formation (50 ℃, 60 min) using a hot-plate and an oven is carried out on cells with a glass/fluorine doped TiO2/TiO2/ZrO2/carbon structure, and the photovoltaic properties of the PSCs are analyzed using a solar simulator. The microstructures of the PSCs are characterized using an optical microscope, a field emission scanning electron microscope, and an electron probe micro-analyzer (EPMA). Photovoltaic analysis shows that the energy conversion efficiency of the samples fabricated using the hot-plate and the oven processes are 2.08% and 6.90%, respectively. Based on the microstructure of the samples and the results of the EPMA, perovskite is formed locally on the carbon electrode surface as the γ-butyrolactone (GBL) solvent evaporates and moves to the top of the carbon electrode due to heat from the bottom of the sample during the hot plate process. When the oven process is used, perovskite forms evenly inside the carbon electrode, as the GBL solvent evaporates extremely slowly because heat is supplied from all directions. The importance of the even formation of perovskite inside the carbon electrode is emphasized, and the feasibility of oven annealing is confirmed for PSCs with carbon electrodes.

Accuracy and Precision of Microwave Oven Digestion/Atomic Absorption Spectrophotometry for Analyzing Airborne Chromium Collected on MCE Filter in Plating Operation (도금공정 크롬시료 분석을 위한 Microwave Oven Digestion/Atomic Absorption Spectrophotometry 방법의 정확도 및 정밀도 평가)

  • Lee, Byung-Kyu;Lee, Ji-Tae;Shin, Yong-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.48-55
    • /
    • 2001
  • The purpose of this study was to evaluate the analytical accuracy and precision of microwave oven digestion/atomi absorption spectrophotometry (AAS) for analyzing airborne chromium collected on mixed cellulose ester membrane (M filter from the work environment, and to compare the accuracy and the precision with those of the National Institute for Occupational Safety and Health (NIOSH) Method #7024 hot plate digestion/AAS method. For this study, field air sample pairs were collected from a electroplating process, and spiked samples in a laboratory were prepared and using these samples. Two digestion methods were comp; and evaluated in terms of recovery rate and bias as indices of accuracy and coefficient of variation as a index of precision. The results and conclusions are as follows. In spiked samples, the accuracies (% mean recoveries) of hot plate/AAS and microwave oven/AAS method were 97.19%, 97.1%, respectively, and the precisions (pooled respectively, and the precisions (pooled coefficient of variance, $CV_{pooled}$) 6.93% and 3.88%, respectively. The biases of hot plate ani microwave oven methods were 4.56 - 14.7% and 2.22 - 7.42% respectively. There was no statistically significant difference between hot plate and microwave oven methods recovery rates of spiked samples (p>0,05). Also, no statistically significant difference was shown among the concentrations of air samples determined by two method (p>0.05). In conclusion, microwave oven/AAS method h excellent accuracy and precision, and advantages such as time-saving and simple procedure in comparison with the classical NIOSH method. Therefore, this method can be use widely to analyze airborne chromium collected on MCE filter from the work environments.

  • PDF

Evaluation of CO2 desorption efficiency of scrubber absorption system in Liquor Plant (주류공정 내 흡수시스템 CO2 탈리 효율 평가)

  • Park, Il-Gun;Park, Hyung-June;Lee, June-Hyung;Kim, Heung-Rae;Lee, Ju-Yeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.173-182
    • /
    • 2020
  • In this study, amino acid salt absorbents were applied to remove and capture high concentrations of CO2 in liquor factories and regeneration performance was confirmed. In order to evaluate the effective treatment of the desorption process, two methods(Hot plate and Steam) were compared at the laboratory scale. As a result, hot plate and Steam. Hot plate methods regeneration efficiency was about 10% and Steam methods was about 60%. The Steam-Tower condition was evaluated by installing a 100㎥/min flow rate scrubber absorption system in the liquor factory. As a result, it was established that the absorbent flow rate was below 4L/min and the steam temperature was above 160℃. Finally regeneration performance was confirmed as 85.5%.

Recent Trends in Flat Hot Rolling of Steel (열간 압연판재 제조기술의 최신동향)

  • 이준정
    • Transactions of Materials Processing
    • /
    • v.11 no.1
    • /
    • pp.24-35
    • /
    • 2002
  • Recent trend and future prospect of flat rolling of steel has been summarized based on the earlier reports. Key technology in the plate rolling is to have ultra fine microstructure having high resistance against crack propagation during application. Heavy accelerated cooling facility and high power rolling mill will be helpful to develope the high toughness steel. Precise modeling of properly prediction based on deformation and transformation imposed on microstructure of steel during processing is highly anticipated. For the hot strip rolling process, new trend is lies on the production of ultra-thin gauged hot strip to substitute cold rolled strip. For the substitution of cold rolled strip into hot rolled strip widely, high formable property of hot strip is highly required. For the formabilit, the ferritic rolling of extra low carbon steel under high lubricated condition is essential. Recently introduced semi-continuous thin slab and rolling mill line is very plausible to develope those kinds of products easily In the view groin facility combination. New idea to modify the existing continuous hot strip mill line to produce the ultra thin-gauged hot strip in an economic way is suggested in this report.

Effects of Pulsating Flow on Evaporation of Refrigerant in a Plate Heat Exchanger (판형 열교환기에서 맥동유동이 냉매의 증발에 미치는 영향)

  • Kang Byung-Ha;Jeong Il-Kwon;Kim Suk-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.627-634
    • /
    • 2006
  • Evaporation heat transfer characteristics by pulsating flow in a plate heat exchanger have been investigated experimentally in this study. R-l34a is evaporated by receiving heat from the hot water in the plate heat exchanger. The pulsating frequency in refrigerant side of the plate heat exchanger is varied in the range of 5-25 Hz. The operating pressure of R-l34a and mass flux of hot water are also varied 0.6-0.9 MPa and $45-105 kg/m^2s$, respectively. The experimental results indicate that evaporation heat transfer coefficient of pulsating flow is improved up to 6.3% compared with that of the steady flow at 10 Hz and $G_w=45 kg/m^2s$. It is also found that the evaporation heat transfer enhancement ratio is decreased with an increase in mass flux of hot water, and the evaporation heat transfer enhancement is little influenced by operating pressure of R-l34a.

A Camber Monitoring System of RM Zone based on Direction Selective Edge Detection Algorithm (방향 선택형 에지검출 알고리즘 기반의 RM존 캠버 모니터링 시스템)

  • Kim, Hyun-Soo;Choi, Yong Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.8
    • /
    • pp.713-717
    • /
    • 2015
  • In this paper, we propose camber monitoring system which is using on hot rolling process. In roughing mill which is one of the rolling part in hot rolling process, steel plate can be bended in width direction under the imbalance of rolling condition. This bending of steel plate in width direction is called as camber. In order to measure the camber, first, cameras which are installed over transport pathway of steel plate take pictures of whole shape of steel plate. And location value of steel plate edge is extrated from these pictures by edge detection algorithm. But, there are a lot of noises which are generated by such as water sprays, dusts, peripheral equipments in these pictures, and these noises make edge detection difficult. In order to solve this kind of problem, we developed a direction selective edge detection algorithm, and applicated in our camber monitoring system. As a result, we got stable results in spite of process noises.

The Characteristics of Thermal Hydraulic Performance for Micro Plate Heat Exchanger with Straight channel (직관채널의 마이크로 판형열교환기 열적 성능 특성)

  • Kim, Yoon-Ho;Lee, Kyu-Jung;Seo, Jang-Won;Jeon, Seung-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.11
    • /
    • pp.767-774
    • /
    • 2008
  • This paper presented the heat transfer and pressure drop characteristics for micro plate heat exchanger with straight channel. The metal sheets for straight channel are manufactured by chemical etching and fabricated micro plate heat exchangers by using the vacuum brazing of bonding technology. The performance experiments are performed within the Reynolds numbers range of 15$\sim$250 under the same flow rate conditions for hot and cold sides. The inlet temperature of hot and cold water are conducted in the range of $30^{\circ}C{\sim}50^{\circ}C$ and $15^{\circ}C{\sim}25^{\circ}C$, respectively. Heat transfer rate and pressure drop are evaluated by the Reynolds numbers and mass flow rates as the inlet temperature variations of the hot and cold sides. Correlations of Nusselt number and friction factor are suggested for micro plate heat exchanger with straight channel using the results of performance experiment.

The Effect of Ambient Air Condition on Heat Transfer of Hot Steel Plate Cooled by an Impinging Water Jet

  • Lee, Pil-Jong;Park, Hae-Won;Lee, Sung-Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.740-750
    • /
    • 2003
  • It has been observed that the cooling capacity of an impinging water jet is affected by the seasonal conditions in large-scale steel manufacturing processes. To confirm this phenomenon, cooling experiments utilizing a hot steel plate cooled by a laminar jet were conducted for two initial ambient air temperatures (10$^{\circ}C$ and 40$^{\circ}C$) in a closed chamber, performing an inverse heat conduction method for quantitative comparison. This study reveals that the cooling capacity at an air temperature of 10$^{\circ}C$ is lower than the heat extracted at 40$^{\circ}C$. The amount of total extracted heat at 10$^{\circ}C$ is 15% less than at 40$^{\circ}C$ , These results Indicate the quantity of water vapor, absorbed until saturation, affects the mechanism of boiling heat transfer.

Study on Internal Void Closure in Slab ingot during Hot Plate Forging (열간 판재단조시 강괴 내부의 기공폐쇄에 관한 연구)

  • 조종래;김동권;김영득;이부윤
    • Transactions of Materials Processing
    • /
    • v.5 no.1
    • /
    • pp.18-26
    • /
    • 1996
  • In order to investigate the effect of pre-cooling of ingot on void closure in hot plate forging the internal strain and stress distributions are examined quantitatively by using ABAQUS. Simula-tions are carried out on a large slab ingot having the same temperature and the temperature gradient induced by air-cooling. It is shown that pre-cooling produces little effect on the strain behavior but remarkable effect on the hydrostatic stress at the central zone of ingot. The main factors for crushing micro-voids are the effective strain and the time integral of hydrostatic stress in the region surrounding the voids. Based on regression analysis it was found that the distortion of void can be expressed as a polynomial function of the two factors.

  • PDF