• 제목/요약/키워드: Hot Water Flow

검색결과 371건 처리시간 0.03초

직렬 연결구조의 유량균등분배 시스템 시공사례 (A Construction Case of Flow Equal Distribution System in Series Connection)

  • 정웅성;이성진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.64-65
    • /
    • 2017
  • The existing hot and cold water supply system have a few problems such as construct ability, damage of the building, maintenance and the unequal distribution of water supply flow. So the system has needs to be improved and the Flow Equal Distribution System(FEDS) in series connection has been innovated by Idin Lab which relieve the existing problems. Thus, the purpose of this study is aimed to show the merits of FEDS with an real example of construction site of Wirye Terrace, D builder. 1. FEDS enables builders to save construction cost as the system in series connection does not need to equip both allotters and loop piping system. 2. FEDS contains a cartridge of water saving function so it mainly reduce the unequal distribution of flow and sudden temperature deviation of hot water supply at the same time. 3. FEDS allows repairer to maintain the water supply system at the same floor that could get rid of disharmony between dwellers who live the upper/lower story of the same building. Therefore, the FEDS will be applied when the building is remodeled and constructed.

  • PDF

열수 주입법에 의한 메탄가스 하이드레이트 펠릿의 해리 특성에 관한 실험 연구 (Experimental Study on the Dissociation Characteristics of Methane Hydrate Pellet by Hot Water Injection)

  • 이승한;윤용석;성관제
    • 대한기계학회논문집B
    • /
    • 제35권11호
    • /
    • pp.1177-1184
    • /
    • 2011
  • GTS 기술은 천연가스 하이드레이트 생산, 해양수송 및 재기화의 3 단계로 구성되며, 대규모 재기화 플랜트의 효율적 운용을 위해서는 하이드레이트 펠릿의 재기화에 필요한 열수 온도와 유량의 정확한 예측이 필수적이다. 하이드레이트 펠릿이 열수에서 해리할 때 펠릿 표면에서 분출되는 가스는 주변 유동장과 열전달 특성에 영향을 미칠 것이며 본 실험에서는 가압된 용기내의 중저온 열수에서 해리하는 메탄가스 하이드레이트 펠릿의 용해특성을 연구하였다. 해리과정 중 변화하는 펠릿 형상을 관찰하고 해리 완료시간을 측정함으로써 하이드레이트 전환율, 열수 온도 및 유동속도가 해리에 미치는 영향을 파악하였으며, 펠릿 표면에서 분출되어 상승하는 메탄가스 기포류가 유발한 2 차유동이 열전달률을 증가시켜 해리 완료시간이 단축됨을 확인하였다.

PWR Hot Leg Natural Circulation Modeling with MELCOR Code

  • Park, Jae-Hong;Lee, Jong-In;Randall. K. Cole;Randall. O. Gauntt
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.772-777
    • /
    • 1997
  • Previous MELCOR and SCDAP/RELAP5 nodalizations for simulating the counter-current, natural circulation behavior of vapor flow within the RCS hot legs and SG U-tubes when core damage progress can not be applied to the steady state and water-filled conditions during the initial period of accident progression because of the artificially high loss coefficients in the hot legs and SG U-tubes which were chosen from results of COMMIX calculation and the Westinghouse natural circulation experiments in a 1/7-scale facility for simulating steam natural circulation behavior in the vessel and in the hot leg and SG during the TMLB' scenrio. The objective of this study is to develop a natural circulation modeling which can be used both for the liquid flow condition at steady state and for the vapor flow condition at the later period of in-vessel core damage. For this, the drag forces resulting from the momentum exchange effects between the two vapor streams in the hot leg was modeled as a pressure drop by pump model. This hot leg natural circulation modeling of MELCOR was able to reproduce similar mass flow rates with those predicted by previous models.

  • PDF

삼중효용 LiBr/물 흡수식 냉방기의 사이클 시뮬레이션 (Cycle simulation of a triple effect LiBr/water absorption chiller)

  • 조광운;정시영;정은수
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.79-87
    • /
    • 1998
  • Basic design of a 50USRT(175㎾) triple effect absorption chiller driven by hot gas has been carried out for both parallel and series flow cycles. Parallel flow cycle showed higher COP, however, the temperature in the generator was also higher than that in series flow cycle. Dynamic operation behavior of a parallel flow system at off-design conditions, such as the change in heat transfer medium temperature or the construction change of the system components, has been investigated in detail. It was found that the cooling capacity was seriously decreased by reducing hot gas flow rate and UA-value in the high temperature generator. However, the system COP was improved, because thermal load in the system components was reduced. The COP and the cooling capacity was found to be improved as cooling water temperature decreased or chilled water temperature increased. The optimum ratio of solution distribution could be suggested by considering the COP, the cooling capacity and the highest temperature in the system, which is critical for corrosion.

  • PDF

An Experimental Study on the Mass and Energy Release for a Hot Leg Break LBLOCA During Post Blowdown

  • S.J. Hong;Kim, J.H.;Park, G.C.
    • Nuclear Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.108-127
    • /
    • 2000
  • Hot leg break LBLOCA(Large Break LOCA) had a potential to be a containment maximum pressure accident in YGN3&4, which was induced from excessive conservatism in the CE analysis methodology of mass and energy release. This study conducted mass and energy release experiment for the hot leg break LBLOCA during post blowdown with an integral test facility, SNUF(Seoul National University Facility). This facility simulated YGN 3&4 with volume ratio of 1/1140 based on Ishii's three level scaling. Experiment showed that SI(Safety Injection) water refilled cold leg first and core later. SI water was vaporized in the core, which resulted in the repressurization of reactor. This increase of pressure drove the water in cold leg to flow up half height of U tubes. However, since the water was drained back soon, the release through the SG side broken section by evaporation was negligibly small. This study also provided experimental assessment of RELAP5 results by KAERI for the release through the SG side broken section.

  • PDF

Improvement of Liquid Droplet Entrainment Model in the COBRA-TF Code

  • Ha, Kwi-Seok;Jeong, Jae-Jun;Sim, Suk-Ku
    • Nuclear Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.181-193
    • /
    • 1998
  • The COBRA-TF liquid droplet entrainment models have been assessed and improved through various experiments. The COBRA-TF code uses the Wurtz entrainment model in the film mist flow regime and the mechanistic model based on the critical Weber number and critical vapor velocity in the hot wall flow regimes, respectively. The Wurtz model has been replaced with the modified Sugawara model. The assessment against the experiments by Hewitt, Keeys, Yanai, and Whalley showed the modified Sugawara model better predicts the steam-water as well as the air-water experiments for the film mist flow regime. For hot wall flow regime, the COBRA-TF entrainment model was modified using two methods, one with an increased critical Weber number and the other with the Yonomoto's critical vapor velocity model. The modified models were assessed using the FLECHT-SEASET bottom reflood tests. The results showed that the Yonomoto model best predicts the quenching time, whereas the local maximum rod temperature was not affected much.

  • PDF

태양열 온수시스템 배관 최적설계 (Optimized Design of Piping Array in Solar Hot Water System)

  • 신정철
    • 에너지공학
    • /
    • 제22권3호
    • /
    • pp.302-306
    • /
    • 2013
  • A simple method for balancing flow rates in arrays of parallel connected flat plate solar collectors has been developed. The method is based on a computer program which solves for the flow rate through each of the collectors in a reverse return plumbed array. The analysis uses conventional "K-value" techniques and assumes the effects of density variations within the system to to be negligible. It has been found that by appropriately sizing the inlet and outlet manifolds, flow maldistribution can be nearly eliminated without resorting to expensive or complicated balancing techniques.

원형수직 충돌 수분류에 의한 고온강판의 냉각특성 연구 (Cooling Characteristics of a Hot Steel Plate by a Circular Impinging Liquid Jet)

  • 오승묵;이상준
    • 대한기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.1150-1155
    • /
    • 1992
  • 본 연구에서는 제철소 열연공정의 냉각효율 개선을 위한 기초연구로 수행되었 다. 전열면의 초기온도가 900.deg. C이상일 때 층류 냉각방식에 의한 고온강판의 냉각특 성에 영향을 주는 모든 인자를 엄밀히 고려하는 것은 매우 어려운 일이다.따라서 본 연구에서는 노즐과 고온면 사이 거리(L), 유량(Q), 냉각 초기온도 등을 실제 작업 조건에 가깝게 변화시켜 가면서 수냉반경의 변화를 중심으로 전열면의 냉각 특성을 해 석하였다.

평만형 태양열 집열기 를 설치한 자연 순환식 급탕시스템 의 성능 에 관한 연구 (Performance of Natural Circulation Hot Water System with Flat-Plate Solar Collectors)

  • 윤석범;전문헌
    • 대한기계학회논문집
    • /
    • 제9권5호
    • /
    • pp.579-589
    • /
    • 1985
  • 본 논문의 모의 실험에 사용한 자연순환식 급탕 시스템과 지금까지 발표된 것 과의 차이점은 다음과 같다. 집열기의 집열성능 계산에 Close의 모델은 시스템의 평 균 온도를 이용하였으며, Mertol의 모델은 집열기의 성능을 일정하게 하여 자연순환식 급탕 시스템의 성능을 계산하였다. 그리고, Young의 모델은 집열기 입구 및 출구 유 체의 평균 온도로 집열기의 집열 성능을 계산하였다. Shitzer, Ong의 연구에서 밝혀 진 바와 같이 집열기 집열판의 온도와 유체 온도는 서로 다르므로, 본 논문에서는 이 것들에서 오는 오차를 줄이기 위해 집열기 순환 유체의 평균 온도와 집열판의 온도를 해석적으로 구하여 집열기의 성능과 순환 유체의 성질 계산에 이용하였다.

복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구 (A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater)

  • 최휘웅;파쿠르 로커만;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.