• 제목/요약/키워드: Hot Ambient Temperature

검색결과 153건 처리시간 0.039초

사지부의 냉각효율성에 관한 연구 (Local Cooling of the Limbs in $37^{\circ}C$ Ambient Temperature)

  • 황경숙;최정화;이경숙
    • 한국지역사회생활과학회지
    • /
    • 제18권1호
    • /
    • pp.87-95
    • /
    • 2007
  • This study was to determine the effect of cooling parts of the limbs without harm to health. The results provide basic data for the development of clothing which could increase work efficiency and reduce body strain in hot environments. Five male adults took part in the study, conducted in a climate chamber with an ambient temperature of $37^{\circ}C$ and a relative humidity of 50%. The limbs were divided into six areas to be cooled: upper arm, forearm, thigh, calf, hand, and foot. According to preceding studies, permissible cooling safety limits of skin temperature for each part of the body for one-hour were $20^{\circ}C$ on the upper arm, forearm, thigh, and calf, and $23^{\circ}C$ on the hand and foot. For this reason, cooling the skin of each region was carried out at the above mentioned temperatures. In conclusion, cooling the hand and foot reduced perspiration, rectal temperature and heart rate. Therefore, the heat stress of workers exposed to hot environments would be reduced by decreased subjective sensations of heat and increased comfort. The effectiveness of cooling was better on the arm than on the leg.

  • PDF

주간온도가 고추의 수확 소요일수 및 수량에 미치는 영향 (Influence of Daytime Temperature on the Time Required for Fruit Harvest and Yield of Hot Pepper)

  • 이상규;최장선;이준구;장윤아;남춘우;이희주;서정민;강점순
    • 한국환경과학회지
    • /
    • 제22권9호
    • /
    • pp.1181-1186
    • /
    • 2013
  • Due to climate change, the occurrence of abnormal weather conditions has become more frequent, causing damage to vegetable crops grown in Korea. Hot pepper, Chinese cabbage and radish, the three most popular vegetables in Korea, are produced more in the field than in the greenhouse. It has been a trend that the time for field transplanting of seedlings is getting earlier and earlier as the spring temperatures keep rising. Seedlings transplanted too early in the spring take a longer time to resume the normal growth, because they are exposed to suboptimal temperature conditions. This study examined the influence of air temperature during seedling growth on the time required to reach the first fruit maturity and yield of hot pepper. Seedling plants of 'Super Manita' hot pepper was grown in temperatures $2.5^{\circ}C$ and $5.0^{\circ}C$ lower than the optimum temperature (determined by the average of temperatures for the past 5 years). Seedlings were transplanted into round plastic containers (30-cm diam., 45-cm height) and were placed in growth chambers in which the ambient temperature was controlled under natural sunlight. The growth of seedlings under lowered temperatures was reduced compared to the control. The mineral (K, Mg, P, N) concentrations in the leaf tissues were higher when plants were grown with the ambient temperature $2.5^{\circ}C$ lower than the optimum, regardless of changes in other growth parameters. Tissue calcium (Ca) concentration was the highest in the plants grown with optimum temperature. The carbohydrate to nitrogen (C/N) ratio, which was the highest (18.3) in the plants grown with optimum temperature, decreased concomitantly as the ambient temperature was lowered $2.5^{\circ}C$ and $5.0^{\circ}C$. The yield of the early harvested fruits was also reduced as the ambient temperature became lower. The first fruit harvest date for the plants grown with optimum temperature (June 27) was 13 days and 40 days, respectively, earlier than that in plants grown with $2.5^{\circ}C$ (July 10) and $5.0^{\circ}C$ (Aug 6) lower ambient temperatures. The fruit yield per plant for the optimum temperature (724 g) was the greatest compared to those grown with $2.5^{\circ}C$ (446 g) and $5.0^{\circ}C$ (236 g) lower temperatures. The result of this study suggests that the growers should be cautioned not to transplant their hot pepper seedlings too early into the field, since it may delay the time of first harvest eventually reducing total fruit yield.

고온벽면에 충돌하는 디젤부문의 특성 연구 (Characteristics of a Diesel Spray Impinging on the Hot Plate)

  • 문석범;구자예
    • 한국자동차공학회논문집
    • /
    • 제7권8호
    • /
    • pp.55-65
    • /
    • 1999
  • An experimenta investigation of unsteady impinging DI diesel spray on the unheated plate and heated plate has been conducted in a pressurized chamber using high speed shadowgraphy. The ambient agas pressure was varied using nitrogen with chamber pressure of 1.1MPa, 2.1MPa and 2.6MPa. As the increase of ambient gas pressure of ambient gas pressure, the height of spray is increased if entrainment and circulation . At higher temperature of impinging plate, the radial penetration of the impinging spary is incresed , but the height of impinging spray is decreased.

  • PDF

Effects on Net Photosynthesis in Field-Grown Hot Peppers Responding to the Increased CO2 and Temperature

  • Yun, Sung-Chul;Ahn, Mun-Il
    • 한국환경농학회지
    • /
    • 제28권2호
    • /
    • pp.106-112
    • /
    • 2009
  • The increased $CO_2$ and temperature (700 ${\mu}$mol.$mol^{-1}$ $CO_2$ and $30^{\circ}C$) was compared with ambient growth conditions (400 ${\mu}$mol.$mol^{-1}$ $CO_2$ and $25^{\circ}C$) in hot pepper. Gas exchange measurements, including net photosynthesis ($P_{net}$) and stomatal conductance ($g_s$), were taken according to treatment in fields of peppers grown in Suwon and Asan during 2008. The increased treatment $P_{net}$ by 35-45% throughout the season and was statistically significant in t-tests (p < 0.001); however, it did not significantly affect $g_s$. In addition, the gas exchange parameters in sun and shade leaves were measured. The difference between the sun and shade leaves was much greater than that between the elevated and ambient treatments, especially at harvest. Four commercial cultivars of hot pepper, Chunhasangsa, Ryukang, Manitta, and Olympic, were also compared by ANOVA. Chunhasangsa had the highest $P_{net}$, which decreased by 30% from the vegetative to the harvest stage. Based on a factorial design, the effect of the increased $CO_2$ and temperature was assessed based on the temperature, $CO_2$, and their interaction effects. Orthogonal contrasts showed that the effects of temperature on $P_{net}$ and $g_s$ were significant, whereas $CO_2$ and their interactions were not.

평판형 액체식 PVT 모듈의 성능 실험 분석 (An Experimental Study of PV/Thermal Combined Collector Module)

  • 강준구;김진희;김준태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.780-785
    • /
    • 2009
  • The photovoltaic/thermal collectors (PV/T collectors) combine the solar thermal collector and photovoltaic modules. They can produce thermal energy in the form of hot air or hot water, and converts solar radiation into electricity. The collecctors can improve the electrical performance of PV modules as the heat from the PV module carried away by the thermal part of the system keeping temperatures lower. The basic water cooled PVT collector has metallic water pipes attached to the back of a PV collector. There are main parameters affecting the performance (electrical and thermal) of PVT collectors. This paper analyzed the experimental performance of glazed water PVT module, considering the parameters of solar radiation, inlet water temperature and ambient temperature. It found that solar radiation is the dominant factor for the electrical performance of the collector, and for the thermal performance the inlet water temperature and ambient temperature appeared to be more related.

  • PDF

열펌프 시스템의 규모 결정을 위한 온돌난방부하 특성 (Characteristics of Ondol Heating Load for the Determination of Heat Pump Power)

  • 노정근;백은기;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제28권3호
    • /
    • pp.217-224
    • /
    • 2003
  • To find out heating load and to determine the power of heat pump compressor for the Ondol room heating the COP of heat pump, the variation of Ondol room air temperature, the variation of ambient temperature and power consumption of heat pump are analyzed. The results from this study were summarized as follows: 1. The COP of the heat pump in close loop decreased as the ambient air temperature. The COP was 2.26 when the temperature difference of condenser was $20\pm3^{\circ}C$. 2. The Ondol surface temperature was $25\pm3^{\circ}C$ when the hot water of $40^{\circ}C$ was supplied from hot water storage tank to the Ondol and the temperature difference between the Ondol surface and the room air temperature was $7~8^{\circ}C$. 3. The ratio of thermal conduction heating load to total heating load in Ondol heating space was found to be 83% and ratio of ventilation heating load was 17%. Therefore, the thermal conduction heating load was confirmod to be a major heating load in Ondol heating space. 4. In case of the ambient temperature of $3.2^{\circ}C$, the efficiency of heat exchange of Ondol heating system was 85%. 5. The heating load per Ondol heating surface area and volume of Ondol room space were theoretically analyzed. In case of the room temperature of $20^{\circ}C$ and the ambient temperature of $-3.2~3.8^{\circ}C$, the heating load per Ondol surface area was 115.8~167.6kJ/h ㆍ㎥ and per Ondol mom space volume was 50.2~72.7kJ/h ㆍ㎥. 6. The compressor power of heat pump fur the Ondol room heating could be determined with the heating load analyzed in this study In case of the Ondol room air temperature of 17~2$0^{\circ}C$ and the ambient temperature of -5~3.8$^{\circ}C$, the compressor power of heat pump per Ondol surface area was analyzed to be $2.3\times10^{-2}psm^2$, and per volume of Ondol room space $1.0\times10^{-2}1.4\times10^{-2}ps/m^2$ps.

한국인 기초 신진대사량의 계절에 따른 변동 (Seasonal Variations in the Basal Metabolic Rate of Korean Airmen Volunteers)

  • 이계열;지선호;홍승길;성양호
    • The Korean Journal of Physiology
    • /
    • 제6권2호
    • /
    • pp.23-30
    • /
    • 1972
  • Contrary to most of European and American investigators failed to find out the seasonal variations of basal metabolic rate in man, Japanese and Korean investigators reported the increase in winter, decrease in summer season. But the causes of variation were not found clearly. To find out whether metabolic acclimatization to climate could be arise or not in human being, the basal metabolic rate was determined monthly for a period of one year in Airmen volunteers who live in Seoul, with 9 l Collins spirometer. The results obtained were as follows: 1. The average ambient temperature was lowest in February $(-5.88^{\circ}C)$ and highest in July $(27.34^{\circ}C)$. 2. Basal metabolic rate was lowest in June and highest in December showing seasonal variations. Interestingly, the increase of basal metabolic rate followed after the drop of ambient temperature below $0^{\circ}C$ (December) and the decrease followed after the elevation of ambient temperature from optimum to hot (June) or cold to warm (March). 3, Mean skinfold thickness increased in spring, decreased in winter. 4. These findings indicate that the basal metabolic rate of Korean reveals the seasonal variation affected by ambient temperature highly.

  • PDF

핀틀이 적용된 고온 가스 밸브 유동장 해석 기법에 관한 연구 (Study on Flow Analysis of Hot Gas Valve with Pintle)

  • 이경욱;허선욱;권세진;이종광
    • 한국추진공학회지
    • /
    • 제19권6호
    • /
    • pp.19-25
    • /
    • 2015
  • 고온밸브의 열/유동 해석을 수행함에 있어 난류모델의 선정 및 해석영역의 변화가 해석 결과에 미치는 영향을 확인하기 위한 연구를 수행하였다. 격자 민감도를 확인하기 위해 100,000~1,700,000 개의 격자에 대해 계산을 수행 하였다. 각각의 난류모델 Spallart-Allmaras, RNG $k-{\varepsilon}$, $k-{\omega}$ SST에서 추력 값은 동일하였지만 온도 분포에서 5% 이내의 차이가 존재 하는 것을 확인 할 수 있었다. 계산 영역을 설정함에 있어 외부 대기 영역은 유동과 온도에 큰 영향을 미치지 않았다. 격자수 변화에 따라 추력 값은 동일하였다. 외부 대기 영역이 존재할 때 격자수 변화에 따라 추력 값은 동일하였지만 온도 분포에서는 차이가 존재 하였다.

외기 온도 증가가 가스 포일 스러스트 베어링의 하중지지 성능과 표면 코팅에 미치는 영향 (Effects of Increasing Ambient Temperatures on the Static Load Performance and Surface Coating of a Gas Foil Thrust Bearing)

  • 조현우;김영우;권용범;김태호
    • Tribology and Lubricants
    • /
    • 제40권3호
    • /
    • pp.103-110
    • /
    • 2024
  • Gas foil thrust bearings (GFTBs) are oil-free self-acting hydrodynamic bearings that support axial loads with a low friction during airborne operation. They need solid lubricants to reduce dry-friction between the runner and top foil and minimize local wears on their surfaces during start-up and shutdown processes. In this study, we evaluate the lift-off speeds and load capacity performance of a GFTB with Polytetrafluoroethylene (PTFE) surface coating by measuring drag torques during a series of experimental tests at increasing ambient temperatures of 25, 75 and 110℃. An electric heat gun provides hot air to the test GFTB operating in the closed booth to increase the ambient temperature. Test results show that the increasing ambient temperature delays the lift-off speed and decreases the load capacity of the test GFTB. An early developed prediction tool well predicts the measured drag torques at 60 krpm. After all tests, post inspections of the surface coating of the top foil are conducted. Scanning electron microscope (SEM) images imply that abrasive wear and oxidation wear are dominant during the tests at 25℃ and 110℃, respectively. A quantitative energy dispersive spectroscopy (EDS) microanalysis reveals that the weight percentages of carbon, oxygen, and nitrogen decrease, while that of fluorine increases significantly during the highest-temperature tests. The study demonstrates that the increasing ambient temperature noticeably deteriorates the static performances and degrades the surface coating of the test GFTB.

공동주택 공기열 멀티 히트펌프의 바닥난방 성능 평가 (Performance Evaluation of Air Source Multi Heat Pump Floor Heating System in Apartment)

  • 이철희;나환선;정훈;김강식
    • 한국기계기술학회지
    • /
    • 제13권3호
    • /
    • pp.93-98
    • /
    • 2011
  • To analyze and evaluate the performance of developing air to water multi heat pump, the heat pump was installed and tested at low energy house in Daejeon, korea. Heating capacity of heat pump is 16.5KW and cooling capacity is 14.0KW. Space heating/cooling, floor heating and hot water is available. The results performance evaluation of heat pump in lab test showed that the coefficient of performance (cop) was 3.75, and heating capacity was 16.0KW in ambient temperature $7^{\circ}C$. Also at ambient temperature $-15^{\circ}C$, the COP was 1.69. At a low energy house, floor heating is controled by a floor heating water temperature and a room temperature. The COP of heat pump is decreased with frequent on/off operation for controlling of floor heating water temperature.