Abstract
Numerical simulations of the hot gas valve with a pintle have been conducted in order to investigate the effect of numerical methods and computational domains. The grid sensitivity is checked by varying the grid number from 100,000 to 1,700,000. The existence of ambient region doesn't make the significant differences of the flow-field and the temperature distribution. Three turbulence models are adopted to figure out its influence on the thrust and temperature distribution: Spallart-Allmaras, RNG $k-{\varepsilon}$, $k-{\omega}$ SST. The thrusts of the hot gas valve are almost same in all cases of the simulation, however, there are about 5% difference in the temperature distribution. With the ambient region, the difference are observed in the temperature distribution with respect to the number of grids.
고온밸브의 열/유동 해석을 수행함에 있어 난류모델의 선정 및 해석영역의 변화가 해석 결과에 미치는 영향을 확인하기 위한 연구를 수행하였다. 격자 민감도를 확인하기 위해 100,000~1,700,000 개의 격자에 대해 계산을 수행 하였다. 각각의 난류모델 Spallart-Allmaras, RNG $k-{\varepsilon}$, $k-{\omega}$ SST에서 추력 값은 동일하였지만 온도 분포에서 5% 이내의 차이가 존재 하는 것을 확인 할 수 있었다. 계산 영역을 설정함에 있어 외부 대기 영역은 유동과 온도에 큰 영향을 미치지 않았다. 격자수 변화에 따라 추력 값은 동일하였다. 외부 대기 영역이 존재할 때 격자수 변화에 따라 추력 값은 동일하였지만 온도 분포에서는 차이가 존재 하였다.