• Title/Summary/Keyword: Hot Air Temperature Control

Search Result 168, Processing Time 0.024 seconds

A Study on the Individual Room Control of Radiant Floor Heating System in Apartment Buildings (공동주택에서 바닥복사 난방시스템의 실별 제어에 관한 연구)

  • 김오봉;이미경;김광우;여명석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.421-429
    • /
    • 2004
  • In Korea, the radiant heating system has been widely used as a residential heating method, which has been modernized to use hot water running into the tubes embedded in the floor structure. According to the recent improvement of living standard of residential buildings, the requirement of the thermal comfort and energy saving in heating system has been raised. Until now, the radiant floor heating system has been controlled by room thermostat installed in the living room, but for better thermal comfort, an individual room control method is adopted as an alternative. Therefore, it is necessary to evaluate the control performance between the current control method and the individual room control method. In this study, the control performance between the two systems is evaluated through the field experiment. And the control performances of room air temperature and energy performances are analyzed through the simulation using TRNSYS. Firstly, the simulations are performed in the various outdoor conditions and the flow rates and the simulation results are analyzed for the control performances. Also, to evaluate the energy performance, the simulations are performed under the operating conditions in which the set-point of the room air temperature is fixed or changed according to the schedule of occupancy, and the simulation results are analyzed between the two methods.

A Study on the Application of the Optimal Control System for Heat Source and HVAC System (열원 및 공조설비의 최적제어시스템 현장 적용성에 관한 연구)

  • Baek, Seung-Jae;Kim, Jin;Ahn, Byung-Cheon;Song, Jae-Yeob
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1014-1019
    • /
    • 2009
  • The optimal control system for heat source and HVAC system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor load and outdoor temperatures. The optimal set-points of control parameters are supply air temperature and chilled or hot water temperatures. The optimal control study has been implemented for biosafety laboratory by using TRNSYS simulation program in order to investigate energy performance for heat source and HVAC system.

  • PDF

Evaluation of Smoke Control Performance of Ventilation System Using by Hot Smoke Test (Hot Smoke Test를 이용한 주차장 환기설비의 제연 성능평가)

  • Joung, Suckhwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.47-56
    • /
    • 2019
  • Recently, in order to overcome the difficulty of entering a fire source due to the occurrence of a large amount of smoke in the event of a fire in a parking lot, it has used that a method of discharge smoke using air supply, exhaust fans and jet fans installed for ventilation of parking lots. In this study, the variation of flow in the smoke layer was observed using CCTV under two conditions, in which only the air supply fan operates and the manned fan operates together, and the temperature around the plume was compared to Albert eq. to assess its suitability as a parking lot ventilation performance evaluation method. As a result, it was found that the smoke layer could be disturbed if the Jet Fan was operated at the same time, which could lead to the possibility of an initial evacuation disturbance. However, the additional operation of the Jet Fan has been confirmed by the observation CCTV that the emission performance is improved, which is believed to help conduct the suppression operation. The temperature around the plume was measured and compared to Alpert eq, and was analyzed to be about $2^{\circ}C$ lower at the center axis of the plume and $9.0^{\circ}C$ higher at 8 m in the direction of the discharge of smoke. The results of temperature measurements around the plume were lower than the maximum temperature expected in AS 4391 and did not exceed the expected temperature risk caused by the experiment. As with these results, the temperature risk from the progression of hot smoke tests is foreseeable, so it will be available as one of the general evaluation methods for assessing smoke control performance in a parking lot without relevant criteria.

Implementation of Real-Time Thermal Environment for Virtual Reality Using Gain Scheduling and Cascade Control (게인 스케쥴링과 캐스케이드 제어에 의한 가상현실용 열환경의 실시간 구현)

  • Sin, Yeong-Gi;Jang, Yeong-Su;Kim, Yeong-Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.7
    • /
    • pp.567-573
    • /
    • 2001
  • A real-time HVAC system is proposed which implements real-time control of thermal environment for virtual reality. It consists of a pair of hot and cold loops that serve as thermal reservoirs, and a mixing box to mix hot and cold air streams flowing if from loops. Their flow rates are controlled in real-time to meet a set temperature and flow rate. A cascade control algorithm along with gain scheduling is applied to the system and test results shows that the closed-loop response approached set values within 3 to 4 seconds.

  • PDF

The Experimental Study of the Heat Flux and Energy Consumption on Variable Flow Rate for Secondary Side of DHS (지역난방 2차측 유량변화가 내부 열유속 및 에너지소비량에 미치는 영향에 관한 실험적 연구)

  • Hong, Seong-Ki;Cho, Sung-Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.5
    • /
    • pp.247-253
    • /
    • 2015
  • The presented work demonstrates the effects of flow rate on the secondary side of DHS (District Heating System). Increasing flow rate at the secondary side of DHS decreases energy consumption and time to reach the set-point of the heated room while increasing heat flux on the floor in the heating space. When flow rate increases, the overall heat transfer rate of radiant floor also increases. However, the results also show overall heat transfer rateto not increased linearly and thus the existence of an optimal flow rate for the secondary side of DHS. Control of the radiant floor with hot water may be more effectively accomplished with a combined control strategy that includes heat flux and a temperature set-point. This experimental analysis has been performed using a lab-scaled DHS pilot plant located at Jeonju University in Korea.

Control of Water Heat Recovery Chiller Using Split Condenser Templifier Application

  • Cho, Haeng-Muk;Mahmud, Iqbal
    • Journal of Energy Engineering
    • /
    • v.18 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • By using the heat recovery of water-cooled chillers, it is possible to reduce the energy operating costs positively and at the same time it could fulfill the heating re-heat air conditioning system as well as the hot water requirements. Basically templifiers are designed to economically to turn the waste heat into useful heat. Waste heat is extracted from a fluid stream by cooling it in the evaporator, the compressor amplifies the temperature of the heat and the condenser delivers the heat to heating loads such as space heating, kitchens and domestic hot water. Design of higher water temperature requirements and split condenser heat recovery chiller system (using of templifiers) produced hotter condenser water approximately up to $60^{\circ}C$ and control the entire heat recovery system.

Comparison of age-standardized incidence rates by places and times: Reported cases of scrub typhus in Jejudo, 2011~2016 (연령표준화 발생률을 이용한 지역별 연도별 감염병 발생 수준 비교: 2011~2016년 제주도 쯔쯔가무시 발생 신고자료)

  • Kim, Jinhee;Kim, Eun Hee;Bae, Jong-Myon
    • Journal of Medicine and Life Science
    • /
    • v.15 no.2
    • /
    • pp.84-88
    • /
    • 2018
  • The aim was to evaluate different results from using crude incidence rate (CIR) instead of agestandardized incidence rate (AIR) when comparing groups having different age structures. After selecting a report using CIRs, AIRs and their 95% confidence intervals(CI) was calculated from the raw data. The statistically significant difference between CIR and AIR was decided based on AIR's 95% CI. Comparing with CIRs, AIRs were under-estimated. In addition, there were no statistical significance of annual trends(P=0.59). These findings are an additional evidence using AIR when comparing level of occurring infectious diseases on groups with different age structures.

Thermal sensation based humidity controls for improving indoor thermal comfort and energy efficiency in summer (온열감각 기반 습도제어를 통한 여름철 건물의 열쾌적 및 에너지성능 향상)

  • Moon, Jin Woo;Chin, Kyung-Il;Kim, Sang-Chul;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.75-81
    • /
    • 2014
  • This study aims at investigating the benefit of actively controlling humidity to improve thermal comfort and energy efficiency in climate zones other than hot-dry. For this research purpose, three thermal control strategies, which adopted different initiative degrees in humidity control, were developed - i) temperature controls, ii) temperature and humidity controls, and iii) thermal sensation controls. Performance of the developed strategies were experimentally tested in a full scale mock up of an office environment. The study revealed that air temperature was better controlled in the occupied zone under the first two strategies than the thermal sensation based strategy. On the other hand, the thermal sensation-based strategy maintained thermal sensation levels more comfortably. In addition, energy consumption was significantly reduced when humidity was actively controlled for thermal comfort. The thermal sensation-based control strategy consumed significantly less electricity than the first two strategies. From these findings, this study indicated that adoption of an active humidity control system based on thermal sensation can provide increased thermal comfort as well as energy savings for summer seasons in climatic zones other than hot-dry.

A Study on the Operational Strategies for Outdoor Air Temperature Change Characteristics in a Radiant Floor Heating System (바닥난방시스템의 외기온도 변화특성을 고려한 운전방안에 관한 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.12
    • /
    • pp.685-692
    • /
    • 2013
  • In this study, the control characteristics and effects of heating control methods on the heating performance and energy consumption of a hot-water heating control system of a residential apartment were researched by simulation and experiment. The purpose of this study is to evaluate operational strategies for improving an indoor thermal environment and reducing f energy consumption in the radiant floor heating system of a residential apartment.

A Study on the Indoor Environmental Factors of Granite Dome Models with Different Envelop Materials during the Summer Season

  • Kong, Sung-Hoon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.65-70
    • /
    • 2001
  • During the summer season, it is very hot and humid in Korea. So the humidity is an important factor regarding the environmental control function of building envelops. The purpose of this research is to measure and analyze the characteristics of such environmental factors as relative humidity, dry bulb temperature and air velocity varies both in the clay and cement envelop structures using granite dome models during the summer time. The interior relative humidity of the clay model is constant regardless of exterior humidity although a little range of variation is shown in comparison to the cement model.

  • PDF