• 제목/요약/키워드: Host and Equipment

검색결과 35건 처리시간 0.025초

인터벤션실의 오염실태 분석 및 평가 (Analysis and Evaluation of Pathogen Contamination Status in Interventional Angiography Room)

  • 김경완;임인철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.233-239
    • /
    • 2022
  • In the radiology department, where radiation is used in medical institutions to perform examinations with various equipment, the field of surgical treatment is the intervention angiography room. Accordingly, strict infection control is required. The purpose of this study was to determine the contamination status by detecting pathogens before and after disinfection in the intervention angiography room, and to determine the degree of death by using a disinfectant, sodium dichloride isocyanurate, which is mainly used in the intervention angiography room. The subjects were 10 medical institutions of general hospital level or higher with an intervention angiography room in the P city, and 12 places with high contact frequency during examinations and procedures were sampled and requested to an analysis institution. As for the sample collection method, up/down, left/right directions were used to increase precision. Before disinfection, all procedures were completed, and after disinfection, exposure was performed using a disinfectant for at least 10 minutes, and detection was performed using a transport medium. As a result, in the pathogen analysis, most pathogens were detected in a humid environment or in a place with high contact frequency for microorganisms to thrive. The detected pathogens were found in the general environment or were human flora. It is a pathogen that does not cause disease under normal healthy host conditions. However, it was found to be an opportunistic infection that causes opportunistic infection depending on the case or situation in which the body's resistance is weakened. In addition, as a result of using the disinfectant mainly used in the intervention angiography room, it was found that more than 93.3% of them died. Therefore, the data of this study will be used as good basic data for the evaluation of pathogens in the intervention angiography room and will be of great help in infection control.

개 희석 정액의 다양한 filtration 처리 후 정자평가 (Evaluation of Extended Canine Semen after Different Filtration Treatment)

  • 김용준;김진영;김수희;이영준
    • 한국임상수의학회지
    • /
    • 제24권4호
    • /
    • pp.577-583
    • /
    • 2007
  • It is important to obtain semen with good quality for efficient fertilization and pregnancy. To obtain these semen, various methods have been developed but most of these methods are time consuming and require costly equipment. Therefore, the objective of this research is to investigate the usability of column filtration system as quick and simple method to get sperm with better quality. Ejaculates were obtained from 5 dogs and analyzed with basic quality parameters before each filtration. Sperm concentration was adjusted to $5{\times}10^7/ml$ after dilution. The experimental groups were divided into non-filtered group(control) and filtered groups(glass wool, Sephadex 5% and Sephadex 20%). Ejaculates were filtered through each filter system and assessed by recovery rate of sperm, motility, normal morphology, CFDA/PI stain and plasma membrane integrity(hypo-osmotic swelling test, HOST). The lowest recovery rate of spermatozoa was recorded in glass wool filtration group, followed by 20% Sephadex filtration group(p<0.05). There was no significant difference between control(non-filtered) and 5% Sephadex filtration poop. Also, there was no significant difference of sperm motility assessed under light microscope among experimental groups. Morphological normality of canine spermatozoa was the highest in the glass wool filtration group and the lowest in the 5% Sephadex filtration group with no significant differences versus 20% Sephadex filtration and control group, respectively(p<0.05). Viability of canine sperm assessed by CFCA/PI staining was the highest in the glass wool filtration poop with no significant difference versus the control group, and the lowest in the 20% Sephadex filtration group with no significant difference versus 5% Sephadex filtration group, respectively(p<0.05). HOS values of canine sperm was the highest in the 20% Sephadex filtration group with no significant difference versus 5% Sephadex filtration group, and the lowest in the control poop with no significant difference versus glass wool filtration group, respectively(p<0.05). Therefore, these results indicated that filtration treatment for extended canine sperm would be useful method to get sperm with better quality by trapping the damaged sperm, consequently filter would be physical barrier against injured or immotile sperm.

스마트폰의 CMOS 영상센서를 이용한 광용적맥파 측정방법 개발 (Development of a Photoplethysmographic method using a CMOS image sensor for Smartphone)

  • 김호철;정원식;이권희;남기창
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.4021-4030
    • /
    • 2015
  • 맥파는 심전도와 같이 자율신경계를 통해 생리적 반응을 측정하는 신호이지만, 손가락에 센서 하나만 부착시키면 되기 때문에 상대적으로 신호의 측정이 간편하다는 장점을 가지고 있어 u-Healthcare 분야에서의 활용이 용이하다. 따라서 본 연구의 목적은 스마트폰 카메라의 CMOS 영상 센서를 활용하여 맥파를 비침습적으로 측정하는 방법 중의 하나인 광용적맥파를 획득하고 이로부터 스트레스 여부를 판단하는 휴대형 시스템을 개발하여 u-Healthcare 분야에서의 활용 가능성을 확인하는 것이다. 이를 위해 광용적맥파를 별도의 센서에 의한 측정이 아닌 스마트폰 카메라에서 획득되는 영상 데이터를 활용하여 광용적맥파를 획득한 후 분석하였다. 또한 확보된 광용적맥파 영상신호 데이터를 이용하여 심박변이도와 스트레스 지수를 별도의 호스트 장비 없이 스마트폰만을 이용해 사용자에게 제공 하였다. 또한 부가적으로 스마트폰에 부착가능한 별도의 하드웨어 디바이스를 개발함으로써 획득된 데이터의 신뢰도 및 정확성을 향상시켰다. 실험결과를 통해 스마트폰의 카메라 영상을 활용하여 광용적맥파 신호를 통한 심박수 측정과 스트레스의 정도를 분석하기 위한 스트레스 지수 추출이 가능함을 확인할 수 있었다. 본 연구에서는 상용화된 제품 또는 정형화된 센서가 아닌 스마트폰의 카메라를 이용하기 때문에 상용화된 외부 센서에 의한 광용적맥파 신호보다는 해상도가 떨어지는 단점이 있음에도 불구하고 결과 데이터의 신뢰도 향상을 위한 별도의 추가외부 장치 개발 및 여러 가지 최적화 알고리즘을 통해 신뢰성 있는 데이터를 확보할 수 있어 u-Healthcare 장비로써의 활용 가능성을 확인할 수 있었다.

치과위생사의 감염 예방 실태 조사 (A Study on Actual Conditions for Prevention of Infections by Dental Hygienists)

  • 남영신;류정숙;박명숙
    • 치위생과학회지
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 2007
  • 이 연구는 치과 진료실에서 치과위생사의 감염예방 실태를 파악하여 치과위생사가 감염예방을 실천하는데 기초 자료로 제공하고자 한다. 연구 대상은 2005년 10월과 11월에 인천경기도회와 서울시회 보수교육에 참여한 치과위생사로 하였으며, 감염 예방에 관한 설문조사를 자기기입방식으로 시행하였다. 그 결과는 다음과 같다. 1. 감염예방 교육경험은 "있다"로 응답한 자가 72명(42.9%)이었고, "없다"고 응답한 자가 96명(57.1%)이었고 감염예방 교육경로를 보면 "근무병원 자체 교육을 통해서"가 42명(58%)으로 가장 많았다. 2. 손상 경험은 "있다"로 응답한 자가 147명(87.5%)이었고 "없다"로 응답한 자가 21명(12.5%)이었으며, 손상 경험이 있는 대상자 147명의 전체 연 평균 손상 횟수는 7.7회였다. 손상을 입힌 기구 명으로는 "explorer"가 125(75%)명으로 가장 많았다. 3. 감염성 질환에 감염된 경험은 "있다"로 응답한 자가 6명(3.6%)이었는데 질환으로는 "B형 간염"이 4명으로 가장 많았고, "풍진" 1명, "결핵" 1명이었다. 4. 실천 점수가 높은 문항은 "2. 나는 진료 후에 손을 씻는다(1.86점)", "7. 나는 국소 마취 후 마취주사바늘 뚜껑을 덮는다(1.86점)", "20. 나는 폐기물을 분리수거하여 적출물처리업자에게 위탁 한다(1.85점)"이었으며, 실천 점수가 낮은 문항은 "16. 나는 진료복을 하루에 한번 갈아입는다(0.24점)"와 "감염성 환자 진료 후에는 진료복을 매번 세탁 한다(0.52점)"이었다. 5. 지식도가 가장 높은 문항은 "1. 치과 진료를 하는 동안에 전염은 감염원, 전염방법, 전염경로, 감염되기 쉬운 숙주에 의해 좌우 된다(0.95점)" 이었으며 지식도가 가장 낮은 문항은 "5. HBV(B형간염)는 95oC에서 5분 이상 가열해야 파괴 된다(0.27점)"이였다. 6. 조직관련 요인 점수가 가장 높은 문항은 "나는 필요한 경우 마스크, 장갑 등의 보호 장구가 항상 이용 가능하다(0.89점)"이었으며 가장 점수가 낮은 문항은 으로 "내가 일하는 곳에는 감염과 관련된 위험한 상황에 노출되었을 때 참고할 수 있는 지침서가 있다(0.33점)" 이었다. 7. 진료환경에서 세면대와 진료실의 거리는 "1미터 미만"이 116명(69.0%), 소독실과 진료실의 거리는 "2미터 미만"이 77명(45.8%)으로 가장 많았으며 보호 장구 구비 현황은 마스크(일회용) 168명(100%), 일회용 장갑(라텍스) 167명(99.4%)으로 대부분 구비되어 있었다. 반면 안면 보호대는 응답자수가 108(64.3%)명으로 가장 적었다. 소독, 멸균기에서는 autoclave가 있다고 응답한 자가 165명(98.2%)이었다.

  • PDF

압타머를 이용한 백혈구제거필터의 개발 및 예비평가 (Development and Preliminary Evaluation of a Leukocyte Removal Aptamer Filter)

  • 이양원;정은숙;최경영;김명한;권소영;조남선;김진숙;박한정;한병돈;윤수영
    • 대한수혈학회지
    • /
    • 제23권2호
    • /
    • pp.107-114
    • /
    • 2012
  • 배경: 혈액제제 내에 혼입된 백혈구로 발생하는 부작용을 예방하기 위해서 백혈구필터를 이용한 백혈구의 제거가 널리 이용되고 있다. 그러나 상용 백혈구 필터로는 이식편대숙주병을 예방하기에는 충분한 백혈구제거가 되지 않아 고가의 기기를 이용한 방사선 조사를 시행하고 있는 실정이다. 한편 항체를 대체하는 압타머를 이용한 기술들이 활발히 개발되어 임상에 사용되기 시작하고 있다. 이에 백혈구에 결합하는 압타머를 이용한 압타머필터를 개발 하여 그 효율과 임상적용 가능성을 평가하고자 하였다. 방법: 포항공대 압타머사업단에 CD45항원에 결합하는 압타머 선별을 의뢰하여 제공받았으며 이를 비드에 부착시켜 백혈구와 결합하도록 한 후 자석을 이용해 제거하는 형식의 압타머필터를 개발하였다. 대한적십자사 혈액원에서 제공받은 백혈구제거적혈구 14단위에 압타머필터를 사용하여 잔여 백혈구를 제거한 후 백혈구 제거율과 적혈구 회수율, 세균배양을 시행하였다. 결과: 압타머필터 후 백혈구는 45.6%가 제거되었으며 92.8%의 적혈구회수율을 보였다. 세균배양에서는 아무것도 자라지 않았다. 결론: 압타머를 이용한 세포제거 기술을 혈액 필터에 적용하고자 CD45항원에 결합하는 압타머를 발굴하여 비드에 부착한 후 수혈 혈액을 필터링함으로써 해당 항원을 가진 세포 즉 백혈구를 제거하도록 하는 압타머필터를 개발하여 이를 평가하였다. 향후 압타머 부착 효율 및 필터과정 개선, 다른 항원에 대한 압타머 적용 등을 통해 혈액제제에서 백혈구 제거율을 높여 이식편대숙주병 예방을 위한 방사선조사를 대체하는 등 임상에 적용할 수 있을 것으로 생각된다.