Skin Damage Sustained During Head-and-Neck and Shoulder Radiotherapy Due to the Curvature of Skin and the Use of Immobilization Mask (머리-목 그리고 어깨의 방사선 치료 시 피부곡면과 고정장치로 인한 피부손상연구)

  • Kim, Soo-Kil;Jeung, Tae-Sig;Lim, Sang-Wook;Park, Yeong-Mouk;Park, Dahl
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.86-92
    • /
    • 2010
  • The purpose of this study was to measure curvature contour skin dose using radiochromic film and TLD for a conventional open field. We also attempted to quantify the degradation of skin sparing associated with use of immobilization devices for high energy photon beams and to calculate the skin dose with a help of Monte Carlo (MC) simulation. To simulate head-and-neck and shoulder treatment, a cylindrical solid water phantom 11 cm in diameter was irradiated with 6 MV x-rays using $40{\times}40\;cm^2$ field at 100 cm source axis distance (SAD) to the center of the phantom. Aquaplastic mesh mask was placed on the surface of the cylindrical phantom that mimicked relevant clinical situations. The skin dose profile was obtained by taking measurements from $0^{\circ}$ to $360^{\circ}$ around the circumference of the cylindrical phantom. The skin doses obtained from radiochromic film were found to be 47% of the maximum dose of $D_{max}$ at the $0^{\circ}$ beam entry position and 61% at the $90^{\circ}$ oblique beam position without the mask. Using the mask (1.5 mm), the skin dose received was 59% at $0^{\circ}$ incidence and 78% at $80^{\circ}$ incidence. Skin dose results were also gathered using thin thermoluminescent dosimeters (TLD). With the mask, the skin dose was 66% at $0^{\circ}$ incidence and 80% at $80^{\circ}$ incidence. This method with the mask revealed the similar pattern as film measurement. For the treatments of the head-and-neck and shoulder regions in which immobilization mask was used, skin doses at around tangential angle were nearly the same as the prescription dose. When a sloping skin contour is encountered, skin doses may be abated using thinner and more perforated immoblization devices which should still maintain immoblization.

An Exploratory Study on Smart Wearable and Game Service Design for U-Silver Generation: U-Hospital Solution for the Induction of Interest to Carry Out Personalized Exercise Prescription (U-실버세대를 위한 스마트 웨어러블 및 연동 게임의 서비스 디자인 방안 탐색: 개인 맞춤형 운동처방 실행을 위한 흥미 유도 목적의 U-Hospital 솔루션)

  • Park, Su Youn;Lee, Joo Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.22 no.1
    • /
    • pp.23-34
    • /
    • 2019
  • The U-Healthcare era has evolved with the development of the Internet of things (IoT) in the early stages of being connected as a society. Already, many changes such as increased well-being and the extension of human life are becoming evident across cultures. Korea entered the growing group of aging societies in 2017, and its silver industry is expected to grow rapidly by adopting the IoT of a super-connected society. In particular, the senior shift phenomenon has resulted in increased interest in the promotion of the health and well-being of the emergent silver generation which, unlike the existing silver generation, is highly active and wields great economic power. This study conducted in-depth interviews to investigate the characteristics of the new silver generation, and to develop the design for a wearable serious game that intends to boost the interest of the elderly in exercise and fitness activities according to their personalized physical training regimes as prescribed by the U-Hospital service. The usage scenario of this wearable serious game for the 'U-silver generation' is derived from social necessity. Medical professionals can utilize this technology to conduct health examinations and to monitor the rehabilitation of senior patients. The elderly can also use this tool to request checkups or to interface with their healthcare providers. The wearable serious game is further aimed at mitigating concerns about the deterioration of the physical functions of the silver generation by applying personalized exercise prescriptions. The present investigation revealed that it is necessary to merge the on / off line community activities to meet the silver generation's daily needs for connection and friendship. Further, the sustainability of the serious game must be enhanced through the inculcation of a sense of accomplishment as a player rises through the levels of the game. The proposed wearable serious game is designed specifically for the silver generation that is inexperienced in using digital devices: simple game rules are applied to a familiar interface grounded on the gourmet travels preferred by the target players to increase usability.

Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy (영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구)

  • Kim, Jin-Sung;Cho, Min-Kook;Cho, Young-Bin;Youn, Han-Bean;Kim, Ho-Kyung;Yoon, Myoung-Geun;Shin, Dong-Ho;Lee, Se-Byeung;Lee, Re-Na;Park, Sung-Yong;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.209-218
    • /
    • 2008
  • According to improved radiation therapy technology such as IMRT and proton therapy, the accuracy of patient alignment system is more emphasized and IGRT is dominated research field in radiation oncology. We proposed to study the feasibility of cone-beam CT system using simple x-ray imaging systems for image guided proton therapy at National Cancer Center. 180 projection views ($2,304{\times}3,200$, 14 bit with 127 ${\mu}m$ pixel pitch) for the geometrical calibration phantom and humanoid phantoms (skull, abdomen) were acquired with $2^{\circ}$ step angle using x-ray imaging system of proton therapy gantry room ($360^{\circ}$ for 1 rotation). The geometrical calibration was performed for misalignments between the x-ray source and the flat-panel detector, such as distances and slanted angle using available algorithm. With the geometrically calibrated projection view, Feldkamp cone-beam algorithm using Ram-Lak filter was implemented for CBCT reconstruction images for skull and abdomen phantom. The distance from x-ray source to the gantry isocenter, the distance from the flat panel to the isocenter were calculated as 1,517.5 mm, 591.12 mm and the rotated angle of flat panel detector around x-ray beam axis was considered as $0.25^{\circ}$. It was observed that the blurring artifacts, originated from the rotation of the detector, in the reconstructed toomographs were significantly reduced after the geometrical calibration. The demonstrated CBCT images for the skull and abdomen phantoms are very promising. We performed the geometrical calibration of the large gantry rotation system with simple x-ray imaging devices for CBCT reconstruction. The CBCT system for proton therapy will be used as a main patient alignment system for image guided proton therapy.

  • PDF

Development of Porcine Pericardial Heterograft for Clinical Application (Microscopic Analysis of Various Fixation Methods) (돼지의 심낭, 판막을 이용한 이종이식 보철편의 개발(고정 방법에 따른 조직학적 분석))

  • Kim, Kwan-Chang;Choi, Chang-Hyu;Lee, Chang-Ha;Lee, Chul;Oh, Sam-Sae;Park, Seong-Sik;Kim, Woong-Han;Kim, Kyung-Hwan;Kim, Yong-Jiin
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.295-304
    • /
    • 2008
  • Background: Various experimental trials for the development of bioprosthetic devices are actively underway, secondary to the limited supply of autologous and homograft tissue to treat cardiac diseases. In this study, porcine bioprostheses that were treated with glutaraldehyde (GA), ethanol, or sodium dodecylsulfate (SDS) were examined with light microscopy and transmission electron microscopy for mechanical and physical imperfections before implantation, Material and Method: 1) Porcine pericardium, aortic valve, and pulmonary valve were examined using light microscopy and JEM-100CX II transmission electron microscopy, then compared with human pericardium and commercially produced heterografts. 2) Sections from six treated groups (GA-Ethanol, Ethanol-GA, SDS only, SDS-GA, Ethanol-SDS-GA and SDS-Ethanol-GA) were observed using the same methods. Result: 1) Porcine pericardium was composed of a serosal layer, fibrosa, and epicardial connective tissue. Treatment with GA, ethanol, or SDS had little influence on the collagen skeleton of porcine pericardium, except in the case of SDS pre-treatment. There was no alteration in the collagen skeleton of the porcine pericardium compared to commercially produced heterografts. 2) Porcine aortic valve was composed of lamina fibrosa, lamina spongiosa, and lamina ventricularis. Treatment with GA, ethanol, or SDS had little influence on these three layers and the collagen skeleton of porcine aortic valve, except in the case of SDS pre-treatment. There were no alterations in the three layers or the collagen. skeleton of porcine aortic valve compared to commercially produced heterografts. Conclusion: There was little physical and mechanical damage incurred in porcine bioprosthesis structures during various glutaraldehyde fixation processes combined with anti-calcification or decellularization treatments. However, SDS treatment preceding GA fixation changed the collagen fibers into a slightly condensed form, which degraded during transmission electron micrograph. The optimal methods and conditions for sodium dodecylsulfate (SDS) treatment need to be modified.

Comparison about adverse drug reaction report forms among Asian's countries using herbal medicine (한약을 사용하는 아시아권 국가의 유해사례 보고 양식에 관한 비교 연구)

  • Sun, Seung-Ho;Lee, Eun-Kyoung;Jang, Bo-Hyoung;Park, Sunju;Go, Ho-Yeon;Jeon, Chan-Yong;Ko, Seong-Gyu
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.19 no.3
    • /
    • pp.91-102
    • /
    • 2015
  • Objective : The purpose of this study is to find out the possibility of application to herbal medicine's report form for adverse drug reaction (ADR) by reviewing and analyzing Asian countries's ADR report forms. Method : We investigated, compared, and analyzed ADR report forms (ADR-RF) of Asian countries's ADR institutions (ACAI), such as, Korea institute of drug safety & risk management and Dongguk university Ilsan oriental hospital (DUIOH) in Korea, national center for ADR monintoring (NCAM) in China, pharmaceuticals and medical devices agency (PMDA) in Japan, Ministry of Health and Welfare (MOHW) in Taiwan, and drug office, department of health, the government of the Hong Kong special administrative region (GHKSAR) in Hong Kong. Results : ADR-RF for ACAI included common contents, such as, patients information (name(initial), gender, age, weight), adverse event (AE)'s report information (Recognition and report for AE occurrence, first or follow up report, Severe AE), the detailed information of AE (the title of AE, onset & closing date of AE symptoms, the progress & results detailed test of AE), the information of AE's medicine (the types of medicine, product name, ingredient name, suspected or combination drug, single dose & frequency, dosage form, administration route, dealing for AE-suspected medicine), and AE reporter's information (reporter's information, institution's information). Taiwan had ADR-RF and the department exclusively for herbal medicine (HM), but others (except DUIOH) had not only no ADR report form but also contents for HM. Conclusion : ADR-RF for HM have to include the common contents of ACAI at least, as well as HM information related to ADR, such as the title, composition and types of HM, history related to HM's ADR, and the contents of drug-induced liver injury and so on. In addition, the main department of government for HM's ADR will be needed.

Applicability and Safety of in Vitro Skin Expansion Using a Skin Bioreactor: A Clinical Trial

  • Jeong, Cheol;Chung, Ho Yun;Lim, Hyun Ju;Lee, Jeong Woo;Choi, Kang Young;Yang, Jung Dug;Cho, Byung Chae;Lim, Jeong Ok;Yoo, James J.;Lee, Sang Jin;Atala, Anthony J.
    • Archives of Plastic Surgery
    • /
    • v.41 no.6
    • /
    • pp.661-667
    • /
    • 2014
  • Background Tissue expansion is an effective and valuable technique for the reconstruction of large skin lesions and scars. This study aimed to evaluate the applicability and safety of a newly designed skin expanding bioreactor system for maximizing the graft area and minimizing the donor site area. Methods A computer-controlled biaxial skin bioreactor system was used to expand skin in two directions while the culture media was changed daily. The aim was to achieve an expansion speed that enabled the skin to reach twice its original area in two weeks or less. Skin expansion and subsequent grafting were performed for 10 patients, and each patient was followed for 6 months postoperatively for clinical evaluation. Scar evaluation was performed through visual assessment and by using photos. Results The average skin expansion rate was $10.54%{\pm}6.25%$; take rate, $88.89%{\pm}11.39%$; and contraction rate, $4.2%{\pm}2.28%$ after 6 months. Evaluation of the donor and recipient sites by medical specialists resulted in an average score of 3.5 (out of a potential maximum of 5) at 3 months, and 3.9 at 6 months. The average score for patient satisfaction of the donor site was 6.2 (out of a potential maximum of 10), and an average score of 5.2 was noted for the recipient site. Histological examination performed before and after the skin expansion revealed an increase in porosity of the dermal layer. Conclusions This study confirmed the safety and applicability of the in vitro skin bioreactor, and further studies are needed to develop methods for increasing the skin expansion rate.

Image Quality Evaluation of Medical Image Enhancement Parameters in the Digital Radiography System (디지털 방사선시스템에서 영상증강 파라미터의 영상특성 평가)

  • Kim, Chang-Soo;Kang, Se-Sik;Ko, Seong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.329-335
    • /
    • 2010
  • Digital imaging detectors can use a variety of detection materials to convert X-ray radiation either to light or directly to electron charge. Many detectors such as amorphous silicon flat panels, CCDs, and CMOS photodiode arrays incorporate a scintillator screen to convert x-ray to light. The digital radiography systems based on semiconductor detectors, commonly referred to as flat panel detectors, are gaining popularity in the clinical & hospital. The X-ray detectors are described between a-Silicon based indirect type and a-Selenium based direct type. The DRS of detectors is used to convert the x-ray to electron hole pairs. Image processing is described by specific image features: Latitude compression, Contrast enhancement, Edge enhancement, Look up table, Noise suppression. The image features are tuned independently. The final enhancement result is a combination of all image features. The parameters are altered by using specific image features in the different several hospitals. The image in a radiological report consists of two image evaluation processes: Clinical image parameters and MTF is a descriptor of the spatial resolution of a digital imaging system. We used the edge test phantom and exposure procedure described in the IEC 61267 to obtain an edge spread function from which the MTF is calculated. We can compare image in the processing parameters to change between original and processed image data. The angle of the edge with respect to the axes of detector was varied in order to determine the MTF as a function of direction. Each MTF is integrated within the spatial resolution interval of 1.35-11.70 cycles/mm at the 50% MTF point. Each image enhancement parameters consists of edge, frequency, contrast, LUT, noise, sensitometry curve, threshold level, windows. The digital device is also shown to have good uniformity of MTF and image parameters across its modality. The measurements reported here represent a comprehensive evaluation of digital radiography system designed for use in the DRS. The results indicate that the parameter enables very good image quality in the digital radiography. Of course, the quality of image from a parameter is determined by other digital devices in addition to the proper clinical image.

Clinical Value of a Desktop Spirometer (HI-801) for Spirometry Screening (선별 검사를 위한 탁상용 폐활량기 (HI-801)의 임상적 유용성에 관한 고찰)

  • Choi, Hye Sook;Choi, Cheon Woong;Park, Myung Jae;Kang, Hong Mo;Yoo, Hong Ji
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.4
    • /
    • pp.276-283
    • /
    • 2007
  • Background: A national health care initiative recommends routine spirometry screening of all smokers over age 45 or patients with respiratory symptoms. In response to the recommendation, new, simple, and inexpensive desktop spirometers for the purpose of promoting widespread spirometric screening were marketed. The performance of these spirometers was evaluated in vivo testing with healthy subjects. However, the clinical setting allows spirometric assessment of various pathologic combinations of flow and volume. Objective: The aim of this study was to compare the accuracy of a desktop spirometer to a standard laboratory spirometer, in a clinical setting with pathologic pulmonary function. Method: In a health check-up center, where screening pulmonary funct test was performed using the HI-801 spirometer. Subjects who revealed the ventilation defect in screening spirometry, performed the spirometry again using the standard Vmax spectra 22d spirometer in a tertiary care hospital pulmonary function laboratory. Pulmonary function test with both spirometer was performed according to the guidelines of the American Thoracic Society. Results: 109 patients were enrolled. Pulmonary function measurements (FVC, $FEV_1$, PEFR, FEF25%-75%) from the HI-801 correlated closely (r=0.94, 0.93, 0.81, 0.84, respectively) with those performed with the Vmax spectra 22d and showed the good limits of agreement and differences between the 2 devices; FVC +0.35 L, $FEV_1$ +0.16 L, PEFR +1.85 L/s, FEF25%-75%-0.13 L/s. With the exception of $FEV_1$, FEF25%-75%, these differences were significant(p<0.05) but small. Conclusion: The HI-801 spirometer is comparable to the standard laboratory spirometer, Vmax spectra 22d, with high accurary for $FEV_1$ and FVC and acceptable differences for clinical use.

Antibiotic Resistance for Common Hospital Acquired-pneumonia Pathogens in the Intensive Care Unit of Newly Opened Hospital (새로 개원한 병원 중환자실에서 주요 원내획득 폐렴 감염균의 연도별 항생제 내성율 변화)

  • Lee, Jae-Hyung;Shin, Sung-Joon;Kim, Young-Chan;Oh, Seung-Il;Kim, Mi-Ok;Park, Eun-Joo;Sohn, Jang-Won;Yang, Seok-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.3
    • /
    • pp.207-218
    • /
    • 2002
  • Background : Intensive care units (ICUs) are generally considered epicenters of antibiotic resistance and the principal sources of multi-resistant bacteria outbreaks. The antibiotic resistance in newly opened intensive care unit that has no microbial colonization on and around the devices was investigated. Materials and Methods : The authors analyzed the antibiotic resistance patterns for common hospital acquired-pneumonia pathogens in the ICUs(Staphylococcus aureus, Pseudomonas aeruginosa, Acinetobacter spp.) at the newly opened ICU of Hanyang University Medical Center, Kuri Hospital during 6 years(1995-2000). Results : 1) Regarding Staphylococcus aureus, the resistance rate to methicillin was 15% at 1995, 21% at 1996, 20% at 1997, 23% at 1998, 22% at 1999, 55% at 2000. 2) Regarding Pseudomonas aeruginosa, the resistance rate to $3^{rd}$ cephalosporin was 50% at 1995, 50% at 1996, 78% at 1997, 40% at 1998, 77% at 1999, 39% at 2000. Imipenam was 0% at 1995, 27% at 1996, 65% at 1997, 12% at 1998, 16% at 1999, 12% at 2000. Ciprofloxacin was 0% at 1996, 56% at 1997, 36% at 1998, 57% at 1999, 58% at 2000. Tobramycin was 7% at 1995, 10% at 1996, 67% at 1997, 36% at 1998, 65% at 1999, 12% at 2000. Gentamycin was 14% at 1995, 36% at 1996, 67% at 1997, 36% at 1998, 65% at 1999, 12% at 2000. Amikacin was 14% at 1995, 30% at 1996, 61% at 1997, 16% at 1998, 39% at 1999, 18% at 2000. 3) Regarding Acinetobacter spp., the resistance rate to $3^{rd}$ cephalosporin was 92% at 1996, 89% at 1997, 88% at 1998,84% at 1999, 77% at 2000. Imipenem was 50% at 1996, 48% at 1997, 45% at 1998, 49% at 1999, 50% at 2000. Ciprofloxacin was 0% at 1996, 48% at 1997, 33% at 1998, 27% at 1999, 71% at 2000. Tobramycin was 67% at 1995, 100% at 1996, 89% at 1997, 95% at 1998, 87% at 1999, 77% at 2000. Gentamycin was 67% at 1995, 100% at 1996, 89% at 1997, 95% at 1998, 87% at 1999, 83% at 2000. Amikacin was 33% at 1995, 83% at 1996, 82% at 1997, 88% at 1998, 75% at 1999, 69% at 2000. Conclusion : The S.aureus resistance to methicillin, the Pseudomonas aeruginosa resistance to ciprofloxacin, and the Acinetobacter spp. resistance to ciprofloxacin have rapidly increased during 6 years. There is a need to pay speicial attention when using the the antibiotics for the above pathogens. This data may be useful in antibiotic therapy in newly opened intensive care units.

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.