• Title/Summary/Keyword: Hospital medical devices

Search Result 303, Processing Time 0.026 seconds

Development of DNA Sensor Using Magnetic Iron Oxide Nanoparticle (자성 산화철(iron oxide) 나노입자를 이용한 DNA 센서 개발)

  • Nam, Ki-Chang;Song, Kwang-Soup
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.6
    • /
    • pp.51-56
    • /
    • 2011
  • The surface of magnetic iron oxide nanoparticles (${\gamma}-Fe_2O_3$) is functionalized ($-NH_2$, -COOH) with bifunctional organic molecules and evaluated using FT-IR (Fourier transform infrared spectroscopy). We immobilize 21-base pair probe DNA and hybridize fluorescence-labeled (Cy5) target DNA onto the functionalized iron oxide nanoparticles. The fluorescence images obtained from a confocal microscopy show that the functionalized iron oxide nanoparticles should detect the hybridization of complementary and noncomplementary DNA.

A Study on the Possible New Fusion between Mobile and Healthcare Service (모바일과 의료서비스 간의 새로운 융합 가능성에 관한 연구)

  • Shin, Yong Jae;Kim, Jin Hwa;Lee, Jea Beom
    • Journal of Information Technology Services
    • /
    • v.11 no.sup
    • /
    • pp.27-39
    • /
    • 2012
  • As many applications are possible now in mobile environment with the trend of mobile convergence, diverse applications in healthcare industry are also possible in mobile devices. Though lots of researches on mobile and health services are introduced, they are limited to specific area or techniques. This study shows possible directions of fusion between mobile technologies and health services in the future using a data mining technique called association rule analysis. The data used in this study is collected from web pages containing key words related to mobile technologies and health services. The analysis shows that current cases of fusion between monitoring based telemedicine and patients. It also shows another case of fusion between mobile hospital and medical screen charts. These show that fusion between mobile technologies and health services already began in industry. Association rules are found between well-being, city, diet, and sleep. The association rules containing security and privacy, though their associations are not so strong, also show that security and privacy of patient information should be protected in the future. The results show that the fusion of mobile technologies and health services is expected to provide health services to more users and larger areas. It is also expected to create new diverse business models in the future.

Study of radiation exposure on human body using of Computed Tomography (전산화단층촬영 검사 시 인체에 미치는 방사선피폭선량 분석연구)

  • Seon, Jong-Ryoul;Yoo, Se-Jong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.193-198
    • /
    • 2015
  • This study analyzed the total number of 19,636 patients and radiation technologists, 11,433 of male and 8,203 of female by examined body parts, age, types of detectors, the using contrast enhancement and working condition of the technologists, regular staffs or rotation-duty staffs, based on the K-DOS program distributed by FDA with the DLP value of diagnostic evaluation. The result shows that the effective radiation dose was 0.7mSv~41.7mSv for each region and male patients had more radiation exposure than females. And the amount of exposure was also affected by the types and the method of detectors. Furthermore, the regular staffs took the role of helping the patient to get reduced amount of radiation exposure than rotation duty-staffs. Computed tomography (CT) use has increased dramatically over the past several decades. In this reason, to support the patients and the workers' health in the field, the hospitals should apply specialized regular working radiation technologist system and manufacturing companies of those CTs should develop low medical radiation exposure devices.

Implementation of Urinary Incontinence Therapy Device with Wireless Bluetooth Communication (무선 요실금 치료기의 구현)

  • Lee, Seung-Jik;Kim, Kyung-Ah;Lee, Tae-Soo;Kim, Wun-Jae;Cha, Eun-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.197-202
    • /
    • 2006
  • Devices in current market to perform electrical stimulation therapy of the urinary incontinence frequent in aging women are very much impractical to us ε due to the wired configuration. The present study implemented new wireless device to enhance self as well as in-hospital therapy with the easiest and the most convenient application. The therapy system consisted of two modules, called 'master' and 'slave', communicating with each other by the wireless Bluetooth protocol. The patient controls therapy processes on the master module in hand, transmitting the required informations to operate the slave module placed within her pants with the viginal electrode connected, delivering appropriate electrical stimulation. Wireless communication enabled self therapy with clothes on, leading to a great convenience for the patient. The stimulation output signal was comparable to commercialized products in both waveform and stimulation capacity.

Asset Localization in Wireless Sensor Networks

  • Jo, Jung-Hee;Kim, Kwang-Soo;Kim, Sun-Joong
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.5
    • /
    • pp.465-471
    • /
    • 2007
  • Many hospitals have been considering new technology such as wireless sensor network(WSN). The technology can be used to track the location of medical devices needed for inspections or repairs, and it can also be used to detect of a theft of an asset. In an asset-tracking system using WSN, acquiring the location of moving sensor nodes inherently introduces uncertainty in location determination. In fact, the sensor nodes attached to an asset are prone to failure from lack of energy or from physical destruction. Therefore, even if the asset is located within the predetermined area, the asset-tracking application could "misunderstand" that an asset has escaped from the area. This paper classifies the causes of such unexpected situations into the following five cases: 1) an asset has actually escaped from a predetermined area; 2) a sensor node was broken; 3) the battery for the sensor node was totally discharged; 4) an asset went into a shadow area; 5) a sensor node was stolen. We implemented and installed our asset-tracking system in a hospital and continuously monitored the status of assets such as ventilators, syringe pumps, wheel chairs and IV poles. Based on this real experience, we suggest how to differentiate each case of location uncertainty and propose possible solutions to prevent them.

A Study on the Safety of Continuous Hemostasis after Arterial Puncture Intervention (동맥천자 인터벤션 시술 후 지속지혈 안전성에 대한 연구)

  • Kim, Seung-Gi
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.195-199
    • /
    • 2019
  • Most of the vascular procedures performed for various diagnoses and treatments of various abdominal intervention procedures performed by the Department of Radiology and Angiography are performed by puncture of the femoral artery. For this reason, patients should undergo blood-related tests such as prothrombin time (PT) and partial thromboplatin time (PTT). Therefore, many patients are instructed to take precautions such as putting a sandbag on the puncture site to prevent delayed hemorrhage after hemostasis of the femoral artery puncture site, and not to bend the leg of the treated area for about 3 hours. Because of this, many patients have complained of pain during the procedure and inconvenience during the absolute bed rest time in the ward. The purpose of this study was to compare the safety of balloon ancillary devices with sandbags placed on the hemostasis site to prevent delayed hemorrhage after arterial puncture. We compared the safety of each patient with the results of medical records in consideration of the problem that the patient could not press with the focus, the position of the patient was changed depending on the patient's body shape, and the problem of falling down according to the location of the puncture site. As a result, the use of a balloon type ancillary device improves the effect of continuous hemostasis, reduces discomfort during the patient's absolute stabilization time, increases the patient's satisfaction, and is a good alternative to the existing sandbag.

Safe clinical photography: best practice guidelines for risk management and mitigation

  • Chandawarkar, Rajiv;Nadkarni, Prakash
    • Archives of Plastic Surgery
    • /
    • v.48 no.3
    • /
    • pp.295-304
    • /
    • 2021
  • Clinical photography is an essential component of patient care in plastic surgery. The use of unsecured smartphone cameras, digital cameras, social media, instant messaging, and commercially available cloud-based storage devices threatens patients' data safety. This paper Identifies potential risks of clinical photography and heightens awareness of safe clinical photography. Specifically, we evaluated existing risk-mitigation strategies globally, comparing them to industry standards in similar settings, and formulated a framework for developing a risk-mitigation plan for avoiding data breaches by identifying the safest methods of picture taking, transfer to storage, retrieval, and use, both within and outside the organization. Since threats evolve constantly, the framework must evolve too. Based on a literature search of both PubMed and the web (via Google) with key phrases and child terms (for PubMed), the risks and consequences of data breaches in individual processes in clinical photography are identified. Current clinical-photography practices are described. Lastly, we evaluate current risk mitigation strategies for clinical photography by examining guidelines from professional organizations, governmental agencies, and non-healthcare industries. Combining lessons learned from the steps above into a comprehensive framework that could contribute to national/international guidelines on safe clinical photography, we provide recommendations for best practice guidelines. It is imperative that best practice guidelines for the simple, safe, and secure capture, transfer, storage, and retrieval of clinical photographs be co-developed through cooperative efforts between providers, hospital administrators, clinical informaticians, IT governance structures, and national professional organizations. This would significantly safeguard patient data security and provide the privacy that patients deserve and expect.

Intraoperative Tumor Localization of Early Gastric Cancers

  • Jeong, Sang-Ho;Seo, Kyung Won;Min, Jae-Seok
    • Journal of Gastric Cancer
    • /
    • v.21 no.1
    • /
    • pp.4-15
    • /
    • 2021
  • Recently, endoscopic screening systems have enabled the diagnosis of gastric cancer in the early stages. Early gastric cancer (EGC) is typically characterized by a shallow invasion depth and small size, which can hinder localization of EGC tumors during laparoscopic surgery. Here, we review nine recently reported tumor localization methods for the laparoscopic resection of EGCs. Preoperative dye or blood tattooing has the disadvantage of spreading. Preoperative 3-dimensional computed tomography reconstruction is not performed in real time during laparoscopic gastrectomy. Thus, they are considered to have a low accuracy. Intraoperative portable abdominal radiography and intraoperative laparoscopic ultrasonography methods can provide real-time feedback, but these methods require expertise, and it can be difficult to define the clips in some gastric regions. Despite a few limitations, intraoperative gastrofibroscopy provides real-time feedback with high accuracy. The detection system using an endoscopic magnetic marking clip, fluorescent clip, and radio-frequency identification detection system clip is considered highly accurate and provides real-time feedback; we expect a commercial version of this setup to be available in the near future. However, there is not yet an easy method for accurate real-time detection. We hope that improved devices will soon be developed and used in clinical settings.

Optical Design of a Snapshot Nonmydriatic Fundus-imaging Spectrometer Based on the Eye Model

  • Zhao, Xuehui;Chang, Jun;Zhang, Wenchao;Wang, Dajiang;Chen, Weilin;Cao, Jiajing
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.151-160
    • /
    • 2022
  • Fundus images can reflect ocular diseases and systemic diseases such as glaucoma, diabetes mellitus, and hypertension. Thus, research on fundus-detection equipment is of great importance. The fundus camera has been widely used as a kind of noninvasive detection equipment. Most existing devices can only obtain two-dimensional (2D) retinal-image information, yet the fundus of the human eye also has spectral characteristics. The fundus has many pigments, and their different distributions in the eye lead to dissimilar tissue penetration for light waves, which can reflect the corresponding fundus structure. To obtain more abundant information and improve the detection level of equipment, a snapshot nonmydriatic fundus imaging spectral system, including fundus-imaging spectrometer and illumination system, is studied in this paper. The system uses a microlens array to realize snapshot technology; information can be obtained from only a single exposure. The system does not need to dilate the pupil. Hence, the operation is simple, which reduces its influence on the detected object. The system works in the visible and near-infrared bands (550-800 nm), with a volume less than 400 mm × 120 mm × 75 mm and a spectral resolution better than 6 nm.

Effect of Shoulder Brace Design on Round Shoulder Posture (어깨 보조기 디자인이 둥근 어깨 자세에 미치는 영향)

  • Kang, Jong Ho;Park, Tae Sung
    • PNF and Movement
    • /
    • v.20 no.3
    • /
    • pp.391-397
    • /
    • 2022
  • Purpose: Recently, as a result of the use of smart devices, the incidence of musculoskeletal diseases in areas such as the neck and shoulders has increased. A common effect is rounded shoulder posture, which badly affects the movement and posture of the scapula, causing musculoskeletal disease. Therefore, in this study, we investigated the effects of three shoulder brace products on rounded shoulder posture. Methods: A total of 12 subjects comprising men and women in their 20s with round shoulder posture participated in this study. Three shoulder brace designs were selected, and the height change of the shoulder acromion in the lying state before and after wearing the braces was measured. Effectiveness verification was analyzed using the Mann-Whitney U test. Results: The results confirmed that the different shoulder brace designs had different effects on round shoulder posture. Conclusion: Currently, numerous designs of shoulder braces are being sold, but their effects have not been verified. In the future, more diverse designs of shoulder braces should be studied, and effective shoulder brace designs should be developed and used.