• 제목/요약/키워드: Hospital image index

검색결과 106건 처리시간 0.026초

한방의료 품질 향상을 위한 신뢰구현 체계구축 연구 (A Research on Trust Realization Strategies for Oriental Medical Quality Improvement)

  • 김현지;김소연;지영승;남승규;김정호;김영일
    • Journal of Acupuncture Research
    • /
    • 제31권1호
    • /
    • pp.75-93
    • /
    • 2014
  • Objectives : This study was designed to establish medical trust realization system by finding factors influential to it using questionnaire. Methods : 277 subjects were participated in this study. After a treatment, we conducted a survey from April 1st to October 31th about medical service perception index, medical trust index, patient satisfaction index, patient reliability index, patient flow degree index, recall intension index, and hospital image index. To evaluate the influence of medical service perception with other 6 indexes, we statistically made regression analysis of the results through the survey. Results : By the results of the analysis, evaluation of hospital image influenced all 6 indexes. The systemicity of treatment process had an effect on 5 indexes except for the flow degree of patients. The humanity of medical team brought out the estimation of 4 indexes except for the patient flow degree and hospital image. The empathic ability of doctor and appropriacy of medical costs hold the next rank influencing 3 indexes. It reached the conclusion that the systemicity of medical team tend to determine the medical trust and patient reliability. The expertise, professional skill of doctor, the fault, commercial application, fame of medical team, the speed of treatment process, the newest and clean medical facility affected each one index. Conclusions : Korean medicine should find a way to consider the mind of patients for improving the medical quality through trust realization system, keeping up with times. As a result of this research, we can find out important causes which influence the trustful medical system. From now on, we should apply this result to actual treatment of psychology customized system. Also, more simple and clear questionnaire was organized through this research, it can be used to forward research to apprehend patient mentality more conveniently.

입원한 조현병 환자의 신체이미지 왜곡 (Body Image Distortion among Inpatients with Schizophrenia)

  • 김성진;문석우;김대호
    • 생물정신의학
    • /
    • 제19권4호
    • /
    • pp.211-218
    • /
    • 2012
  • Objectives Body image distortion is found in eating disorder and obesity and there are some evidence that schizophrenia is associated with body image distortion. This study sought to find whether schizophrenic patients report more body image distortion than healthy individuals and whether it is related with symptomatology. Methods A total of 88 inpatients with schizophrenia and 88 healthy controls were recruited. Weight, height, and body image accuracy were assessed in all participants, and assessment of mood, psychotic symptom severity and self-esteem, and personal and social performance scale were conducted. Results The patients with schizophrenia had higher Body Mass Index (p < 0. 001) and underestimated their body size more than controls (26.14% vs. 5.13%, p < 0.001). Multiple regression analysis showed that lower depressive symptoms and higher scores of general psychopathology predicted underestimation of body size. Conclusion Weight gain and metabolic syndrome are common adverse events of pharmacological treatment of schizophrenia. Thus, underestimation of body size among patients with schizophrenia may interfere with effort to lose weight or seek weight reduction programs. Clinicians need to consider possible unterestimation of underestimation of body size in patients whose general symptomatology is severe.

Subjective Imaging Effect Assessment for Intelligent Imaging Terminal Design: a Method for Engineering Site

  • Liu, Haoting;Lv, Ming;Yu, Weiqun;Guo, Zhenhui;Li, Xin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권3호
    • /
    • pp.1043-1064
    • /
    • 2020
  • A kind of Subjective Imaging Effect Assessment (SIEA) method and its applications on intelligent imaging terminal design in engineering site are presented. First, some visual assessment indices are used to characterize the imaging effect: the image brightness, the image brightness uniformity, the color image contrast, the image edge blur, the image color difference, the image saturation, the image noise, and the integrated imaging effect index. A linear weighted function is employed to carry out the SIEA computation and the Analytic Hierarchy Process (AHP) technique is used to estimate its weights. Second, a SIEA software is developed. It can play images after the settings of assessment index or assessment reaction time, etc. Third, two cases are used to illustrate the application effects of proposed method: the image enhancement system design for surveillance camera and the imaging environment perception system design for intelligent lighting terminal. A Prior Sequential Stimulus (PSS) experiment is proposed to improve the evaluation stability of SIEA method. Many experiment results have shown the proposed method can realize a stable system design or parameters setting for the intelligent imaging terminal in engineering site.

Machine Learning-Based Prediction of COVID-19 Severity and Progression to Critical Illness Using CT Imaging and Clinical Data

  • Subhanik Purkayastha;Yanhe Xiao;Zhicheng Jiao;Rujapa Thepumnoeysuk;Kasey Halsey;Jing Wu;Thi My Linh Tran;Ben Hsieh;Ji Whae Choi;Dongcui Wang;Martin Vallieres;Robin Wang;Scott Collins;Xue Feng;Michael Feldman;Paul J. Zhang;Michael Atalay;Ronnie Sebro;Li Yang;Yong Fan;Wei-hua Liao;Harrison X. Bai
    • Korean Journal of Radiology
    • /
    • 제22권7호
    • /
    • pp.1213-1224
    • /
    • 2021
  • Objective: To develop a machine learning (ML) pipeline based on radiomics to predict Coronavirus Disease 2019 (COVID-19) severity and the future deterioration to critical illness using CT and clinical variables. Materials and Methods: Clinical data were collected from 981 patients from a multi-institutional international cohort with real-time polymerase chain reaction-confirmed COVID-19. Radiomics features were extracted from chest CT of the patients. The data of the cohort were randomly divided into training, validation, and test sets using a 7:1:2 ratio. A ML pipeline consisting of a model to predict severity and time-to-event model to predict progression to critical illness were trained on radiomics features and clinical variables. The receiver operating characteristic area under the curve (ROC-AUC), concordance index (C-index), and time-dependent ROC-AUC were calculated to determine model performance, which was compared with consensus CT severity scores obtained by visual interpretation by radiologists. Results: Among 981 patients with confirmed COVID-19, 274 patients developed critical illness. Radiomics features and clinical variables resulted in the best performance for the prediction of disease severity with a highest test ROC-AUC of 0.76 compared with 0.70 (0.76 vs. 0.70, p = 0.023) for visual CT severity score and clinical variables. The progression prediction model achieved a test C-index of 0.868 when it was based on the combination of CT radiomics and clinical variables compared with 0.767 when based on CT radiomics features alone (p < 0.001), 0.847 when based on clinical variables alone (p = 0.110), and 0.860 when based on the combination of visual CT severity scores and clinical variables (p = 0.549). Furthermore, the model based on the combination of CT radiomics and clinical variables achieved time-dependent ROC-AUCs of 0.897, 0.933, and 0.927 for the prediction of progression risks at 3, 5 and 7 days, respectively. Conclusion: CT radiomics features combined with clinical variables were predictive of COVID-19 severity and progression to critical illness with fairly high accuracy.

Multi-access for the Diagnosis of Missed Upper Lumbar Disc Herniation

  • Lee, Dong-Yeob;Kim, Hyung-Seok;Lee, Sang-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권2호
    • /
    • pp.144-146
    • /
    • 2005
  • Herein, a case of missed upper lumbar disc herniation, diagnosed by thorough neurological examination, digital infrared thermographic imaging[DITI], and repeated magnetic resonance[MR] image study, is reported. A 36-year-old female presented with intractable leg pain on left anterior thigh. Although she underwent lumbar MR image at other hospital, she was misdiagnosed as acute sprain. Neurological examination suggested the possibility of upper lumbar disc herniation, which was confirmed by DITI, MRI, and selective root block. After operation, her leg pain was significantly improved. It should be considered that upper lumbar disc herniation might be misdiagnosed as an acute sprain, as in our case. A high index of suspicion based on thorough neurological examination is most important in such cases. Then, multi-access such as DITI, MR image, and selective block, base on thorough neurological examination, are warranted.

Acceptance Test and Clinical Commissioning of CT Simulator

  • An, Hyun Joon;Son, Jaeman;Jin, Hyeongmin;Sung, Jiwon;Chun, Minsoo
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.160-166
    • /
    • 2019
  • This study examined the clinical use of two newly installed computed tomography (CT) simulators in the Department of Radiation Oncology. The accreditation procedure was performed by the Korean Institute for Accreditation of Medical Imaging. An Xi R/F dosimeter was used to measure the CT dose index for each plug of the CT dose index phantom. Image qualities such as the Hounsfield unit (HU) value of water, noise level, homogeneity, existence of artifacts, spatial resolution, contrast, and slice thickness were evaluated by scanning a CT performance phantom. All test items were evaluated as to whether they were within the required tolerance level. CT calibration curves-the relationship between CT number and relative electron density-were obtained for dose calculations in the treatment planning system. The positional accuracy of the lasers was also evaluated. The volume CT dose indices for the head phantom were 22.26 mGy and 23.70 mGy, and those for body phantom were 12.30 mGy and 12.99 mGy for the first and second CT simulators, respectively. HU accuracy, noise, and homogeneity for the first CT simulator were -0.2 HU, 4.9 HU, and 0.69 HU, respectively, while those for second CT simulator were 1.9 HU, 4.9 HU, and 0.70 HU, respectively. Five air-filled holes with a diameter of 1.00 mm were used for assessment of spatial resolution and a low contrast object with a diameter of 6.4 mm was clearly discernible by both CT scanners. Both CT simulators exhibited comparable performance and are acceptable for clinical use.

디지털 흉부 방사선 영상의 체질량지수에 따른 영상품질 분석: 미국 방사선 안전국 규정 평가표 중심으로 (Analysis of Image Quality According to BMI of Digital Chest Radiography: Focusing on Bureau of Radiological Health Evaluation)

  • 진성진;임인철;조지환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.1-6
    • /
    • 2017
  • 흉부방사선 영상의 평가는 시각에 의한 사진평가가 가장 실용적이고 효과적인 방법으로 알려져 있다. 미국 방사선 안전국 규정 평가표(Bureau of Radiological Health, BRH)는 흉부방사선 영상의 해부학적 평가와 물리적 평가를 합하여 평가하는 효율적인 영상 평가방법이다. 본 연구는 여성 351명의 흉부방사선 영상을 체질량지수(Body Mass Index, BMI)와 허리둘레, 관전류량(mAs)과의 관계를 비교하고, 미국 방사선 안전국 규정 평가표를 사용하여 흉부 방사선 영상품질평가를 시행하였다. 대상자의 평균 연령은 $30.17{\pm}4.73$세이고, 허리둘레는 평균 $66.91{\pm}4.67cm$이었다. 체질량지수 값의 평균은 $20.21{\pm}2.23$으로 나타났으며, 전체 대상자의 관전류량 평균값은 $3.04{\pm}0.78$이고, 미국 방사선 안전국 규정 평균값은 $79.83{\pm}8.45$이었다. 허리둘레가 커질수록 관전류량 값이 증가함으로 나타났으며, 체질량지수가 커질수록 mAs값도 증가하였다. 연구대상자의 허리둘레, 관전류량, 미국 방사선 안전국 규정 값은 체질량지수 값이 커지면 허리둘레와 관전류량 평균값이 증가하였고, 미국 방사선 안전국 규정 값은 체질량지수가 높은 그룹이 낮은 그룹에 비하여 상대적으로 낮게 나타났으며, 통계적으로 유의하였다. 흉부검사 시 피검자의 신체두께나 체질량지수에 따라 자동노출제어 장치의 노출제어가 적절히 잘 이루어진 것으로 생각되며, 체질량지수가 증가할수록 신체두께가 커지고 또한 여성의 유방 두께도 증가하여 자동노출제어 장치에 의한 노출량이 변화되어 영상품질에 영향을 미치는 것으로 생각되어진다.

디지털 흉부 방사선 검사의 화질과 선량의 최적화에 관한 연구 (A Study on the Optimization of Image Quality and Dose in Chest PA Digital Radiography)

  • 박한솔;김명성;정홍문;이종웅
    • 한국방사선학회논문지
    • /
    • 제11권1호
    • /
    • pp.55-61
    • /
    • 2017
  • Chest PA 검사 시 디지털 촬영에 대한 검사 조건 권고안은 마련되어 있지 않다. 각 기기 회사들도 이전의 아날로그 촬영에 적용되었던 고관전압 촬영 조건을 권고하고 있다. 디지털 흉부 X-선 촬영시 관전압, 관전류, 부가여과 필터 변화에 따른 피폭선량을 비교하기 위해 Philips 사에서 권고하는 적정 노출지수( Expos ure Index ) 값인 200 ~ 800사이 값을 만족하는 검사조건을 선별하였다. 유효선량을 평가하기 위해 몬테카를로 시뮬레이션을 시행하였으며 SNR과 CNR을 측정하여 영상평가를 시행하였다. 관전압과 관전류, 부가여과 필터를 조절하여 유효 선량을 최대 77% 까지 감소시킬 수 있었다. 검사조건별로 다소간의 차이는 있으나 영상평가 결과 비슷한 품질의 영상을 얻을 수 있었다.

Viscoelastic Property of the Brain Assessed With Magnetic Resonance Elastography and Its Association With Glymphatic System in Neurologically Normal Individuals

  • Bio Joo;So Yeon Won;Ralph Sinkus;Seung-Koo Lee
    • Korean Journal of Radiology
    • /
    • 제24권6호
    • /
    • pp.564-573
    • /
    • 2023
  • Objective: To investigate the feasibility of assessing the viscoelastic properties of the brain using magnetic resonance elastography (MRE) and a novel MRE transducer to determine the relationship between the viscoelastic properties and glymphatic function in neurologically normal individuals. Materials and Methods: This prospective study included 47 neurologically normal individuals aged 23-74 years (male-to-female ratio, 21:26). The MRE was acquired using a gravitational transducer based on a rotational eccentric mass as the driving system. The magnitude of the complex shear modulus |G*| and the phase angle 𝛗 were measured in the centrum semiovale area. To evaluate glymphatic function, the Diffusion Tensor Image Analysis Along the Perivascular Space (DTI-ALPS) method was utilized and the ALPS index was calculated. Univariable and multivariable (variables with P < 0.2 from the univariable analysis) linear regression analyses were performed for |G*| and 𝛗 and included sex, age, normalized white matter hyperintensity (WMH) volume, brain parenchymal volume, and ALPS index as covariates. Results: In the univariable analysis for |G*|, age (P = 0.005), brain parenchymal volume (P = 0.152), normalized WMH volume (P = 0.011), and ALPS index (P = 0.005) were identified as candidates with P < 0.2. In the multivariable analysis, only the ALPS index was independently associated with |G*|, showing a positive relationship (β = 0.300, P = 0.029). For 𝛗, normalized WMH volume (P = 0.128) and ALPS index (P = 0.015) were identified as candidates for multivariable analysis, and only the ALPS index was independently associated with 𝛗 (β = 0.057, P = 0.039). Conclusion: Brain MRE using a gravitational transducer is feasible in neurologically normal individuals over a wide age range. The significant correlation between the viscoelastic properties of the brain and glymphatic function suggests that a more organized or preserved microenvironment of the brain parenchyma is associated with a more unimpeded glymphatic fluid flow.

비만이 소아의 삶의 질에 미치는 영향 (Impact of Obesity on Health-Related Quality of Life among Children)

  • 권윤정;정조은;허휴정;조현;김대진
    • 생물정신의학
    • /
    • 제22권3호
    • /
    • pp.128-134
    • /
    • 2015
  • Objectives To examine the relationship between health-related quality of life (HRQoL) and body mass index (BMI) of obese children. Methods This cross-sectional study included 387 children. HRQoL was measured with the PedsQLTM 4.0 Generic Core Scale. BMI was classified according to the World Health Organization Asia-Pacific obesity guidelines. Psychosocial factors (body image, self-esteem, and depression/anxiety) were also measured. Data were analyzed using one-way analysis of variance, Pearson's correlation and Path analysis. Results Obese participants reported lower score for physical evaluation, self-esteem, appearance evaluation component of body image, total HRQoL score, and physical/emotional/social function components of HRQoL ; they reported higher score for depression/anxiety. In addition, results indicated that as BMI increased, appearance evaluation, total HRQoL score, and social function component of HRQoL dropped. Path analysis revealed that BMI did not directly affect HRQoL ; however, BMI directly affects body image and self-esteem, indirectly mediates depression/anxiety, and thereby impacts on an individual's HRQoL. Conclusions Body image and self-esteem, rather than BMI itself, have more influence on HRQoL. This reinforces the importance of therapeutic intervention to enhance body image and self-esteem among obese children.