• 제목/요약/키워드: Hospital image

검색결과 2,039건 처리시간 0.024초

뇌졸중 환자의 일상생활 수행능력, 신체상이 삶의 질에 미치는 영향: 대인관계 매개효과 중심 (Relationships of Activities of Daily Living and Body Image with Quality of Life in Stroke Patients: Mediating Effects of Interpersonal Relations)

  • 김민주;박효민
    • 근관절건강학회지
    • /
    • 제28권2호
    • /
    • pp.183-191
    • /
    • 2021
  • Purpose: This study was conducted to identify factors associated with stroke patients' quality of life (QOL) and examine the mediating effects of interpersonal relations in the relationships of activities of daily living (ADL) and body image with QOL. Methods: In this study, 160 stroke patients were recruited from an outpatient clinic of a university hospital and rehabilitation clinic of a long-term care hospital. Participants completed a questionnaire which included sociodemographic characteristics, ADL, body image, interpersonal relation, and QOL. Descriptive statistics, t-tests, ANOVA, Pearson's correlation coefficients, multiple regression analysis, and process macro mediation analysis were conducted using SPSS. Results: The mean scores were 91.01 (range 6~100) for ADL, 61.19 (range 40~79) for body image, 87.53 (range 29~123) for interpersonal relations, and 186.67 (range 71~243) for QOL. Multiple regression analyses showed that ADL, body image, interpersonal relations, and participation in group activities after stroke were significantly associated with QOL among stroke patients (p<.05). There were no mediating effects of interpersonal relations in the relationships of ADL and body image with QOL (p>.05). Conclusion: This study showed that there is a need for physical, psychological, and social recovery to improve the QOL of stroke patients.

Feasibility of Free-Breathing, Non-ECG-Gated, Black-Blood Cine Magnetic Resonance Images With Multitasking in Measuring Left Ventricular Function Indices

  • Pengfei Peng;Xun Yue;Lu Tang;Xi Wu;Qiao Deng;Tao Wu;Lei Cai;Qi Liu;Jian Xu;Xiaoqi Huang;Yucheng Chen;Kaiyue Diao;Jiayu Sun
    • Korean Journal of Radiology
    • /
    • 제24권12호
    • /
    • pp.1221-1231
    • /
    • 2023
  • Objective: To clinically validate the feasibility and accuracy of cine images acquired through the multitasking method, with no electrocardiogram gating and free-breathing, in measuring left ventricular (LV) function indices by comparing them with those acquired through the balanced steady-state free precession (bSSFP) method, with multiple breath-holds and electrocardiogram gating. Materials and Methods: Forty-three healthy volunteers (female:male, 30:13; mean age, 23.1 ± 2.3 years) and 36 patients requiring an assessment of LV function for various clinical indications (female:male, 22:14; 57.8 ± 11.3 years) were enrolled in this prospective study. Each participant underwent cardiac magnetic resonance imaging (MRI) using the multiple breath-hold bSSFP method and free-breathing multitasking method. LV function parameters were measured for both MRI methods. Image quality was assessed through subjective image quality scores (1 to 5) and calculation of the contrast-to-noise ratio (CNR) between the myocardium and blood pool. Differences between the two MRI methods were analyzed using the Bland-Altman plot, paired t-test, or Wilcoxon signed-rank test, as appropriate. Results: LV ejection fraction (LVEF) was not significantly different between the two MRI methods (P = 0.222 in healthy volunteers and P = 0.343 in patients). LV end-diastolic mass was slightly overestimated with multitasking in both healthy volunteers (multitasking vs. bSSFP, 60.5 ± 10.7 g vs. 58.0 ± 10.4 g, respectively; P < 0.001) and patients (69.4 ± 18.1 g vs. 66.8 ± 18.0 g, respectively; P = 0.003). Acceptable and comparable image quality was achieved for both MRI methods (multitasking vs. bSSFP, 4.5 ± 0.7 vs. 4.6 ± 0.6, respectively; P = 0.203). The CNR between the myocardium and blood pool showed no significant differences between the two MRI methods (18.89 ± 6.65 vs. 18.19 ± 5.83, respectively; P = 0.480). Conclusion: Multitasking-derived cine images obtained without electrocardiogram gating and breath-holding achieved similar image quality and accurate quantification of LVEF in healthy volunteers and patients.

흉부영상에서 평활화 시 심장저부 음영의 신호 대 잡음비 비교평가 (Evaluation and Comparison of Signal to Noise Ratio According to Histogram Equalization of Heart Shadow on Chest Image)

  • 김기원;이을규;정회원;손진현;강병삼;김현수;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권2호
    • /
    • pp.197-203
    • /
    • 2017
  • 본 연구는 흉부영상에서 심장저부 음영 관심영역(Region of Interest; ROI)의 신호대잡음비(Signal to Noise Ratio; SNR)를 Post processing에서의 이퀄라이제이션 기법으로 측정 평가하였다. 연구대상은 대학병원에서 흉부검사를 실시한 환자 87명이다. 측정방법은 ImageJ 프로그램을 사용하여 표본의 인구사회학적 특성, 영상별 흉부영상의 SNR평균값, 95% 신뢰구간 값, SNR평균차이 값 등을 분석하였다. 이때 SPSS Statistics21 통계프로그램으로 ANOVA 분석을 하였으며, 95%(p < 0.05)에서 유의한 것으로 판단하였다. 영상별 분석결과의 SNR은 Original chest image, Original chest image heart shadow, Equalization chest image, Equalization chest image heart shadow순으로 높은 값을 나타냈다(p < 0.001). 결론적으로, 본 연구에서는 흉부영상의 평활화 시 심장저부 음영의 정량화한 평가결과를 보조적인 수단으로 활용할 수 있을 것으로 사료된다.

핵의학 간담도 스캔 시, 전면상과 우측 측면상에서의 담낭박출률에 대한 비교 및 고찰 (Comparison and Review of GBEF% on the Anterior and Right Lateral Images of Nuclear Hepatobiliary Scan)

  • 이은별;김재일;도용호;임정진;조성욱;노경운
    • 핵의학기술
    • /
    • 제22권2호
    • /
    • pp.92-96
    • /
    • 2018
  • 핵의학 간담도 검사 시, 담낭의 수축력을 정량적으로 평가하기 위하여 지방식(fatty meal)을 이용한 전면상에서의 담낭박출률(gallbladder ejection fraction ; GB EF%)을 진단에 이용하고 있다. 하지만, 담낭과 다른 구조물이 전면상에서 겹쳐질 경우, 담낭 박출률 평가가 정확히 이루어지지 않는다. 이러한 오차를 줄이기 위해 본 연구에서는 전면상과 우측 측면상에서 계산한 GBEF%의 유의한 차이가 있는 지 알아보고자 한다. 본원에 내원한 임의의 환자 50명을 대상으로 $^{99m}Tc$-Mebrofenin 370 MBq를 정맥주사 후 간담도 검사를 실행하였다. 검사는 SKYLIGHT(Philips, United States)을 이용하여 10분, 20분, 30분, 60분, 그리고 지방식(치즈와 우유)을 시행하고 30분 후에 90분 째, 전면상과 우측 측면 영상을 획득하였다. JETstream workspace 프로그램에서 60분째와 90분째 전면상과 우측 측면상에서 GBEF%을 구하였다. 보다 정확한 관심영역 설정을 위해 CT영상을 참고하였고, 4명의 방사선사가 동일한 영상에서의 GBEF%을 구하여 평균값을 계산하였다. 통계분석프로그램SPSS version23(SPSS Inc. USA)을 이용하여 전면상과 우측 측면상에서 GBEF%의 차이에 유의한 차이가 있는지 평가하였다. 무작위 50명 환자의 전면상에서 GBEF%의 평균값은 63.2고, 우측 측면상에서 GBEF%의 평균값은 62.7으로 전면상 대비 우측 측면상에서 0.5% 감소하였다. 전면상과 우측 측면상에서 GBEF%의 대응표본 t-검정 결과 P>0.05으로 유의한 차이가 없었다. 이를 통해 전면상에서 담낭과 다른 구조물이 분리되지 않아 담낭박출률의 오차가 발생하는 경우, 우측 측면상을 이용하여 GBEF%을계산하면 보다 더 정확한 담낭박출률이 평가되는 것으로 사료된다.

영상기반 방사선 치료기기를 위한 QA 팬텀 시작품 개발 (Development of QA Phantom Prototype for Imaged Based Radiation Treatment System)

  • 장지나;오승종;정원균;장홍석;김회남;강대규;이두현;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제19권2호
    • /
    • pp.120-124
    • /
    • 2008
  • 본 연구에서는 영상 기반 방사선 치료기기의 영상 QA를 위한 필요한 추가적인 요소를 포함시킨 QA 팬텀 시제품을 개발하였다. 개발된 팬텀은 크게 영상 질 평가 부분과 정합 정확도 평가 부분의 두 가지로 이루어져 있다. 영상 질 평가를 위해 CT number 선형성과 공간 해상도 평가가 가능하게 설계되었고, 정합 정확도 평가를 위하여 간단한 이동 및 회전조절이 가능하게 설계되었다. 제작된 팬텀의 영상은 일반 CT와 Tomotherapy의 MVCT에서 획득되었고, 두 영상 모두 해상도 평가 기준을 충족하였다. 이 팬텀은 일간 영상 QA를 위한 간단하고, 효율적이며, 그리고 영상 정합 평가의 새로운 개념을 제시했다는 데에 큰 의의가 있다.

  • PDF

A Novel Fundus Image Reading Tool for Efficient Generation of a Multi-dimensional Categorical Image Database for Machine Learning Algorithm Training

  • Park, Sang Jun;Shin, Joo Young;Kim, Sangkeun;Son, Jaemin;Jung, Kyu-Hwan;Park, Kyu Hyung
    • Journal of Korean Medical Science
    • /
    • 제33권43호
    • /
    • pp.239.1-239.12
    • /
    • 2018
  • Background: We described a novel multi-step retinal fundus image reading system for providing high-quality large data for machine learning algorithms, and assessed the grader variability in the large-scale dataset generated with this system. Methods: A 5-step retinal fundus image reading tool was developed that rates image quality, presence of abnormality, findings with location information, diagnoses, and clinical significance. Each image was evaluated by 3 different graders. Agreements among graders for each decision were evaluated. Results: The 234,242 readings of 79,458 images were collected from 55 licensed ophthalmologists during 6 months. The 34,364 images were graded as abnormal by at-least one rater. Of these, all three raters agreed in 46.6% in abnormality, while 69.9% of the images were rated as abnormal by two or more raters. Agreement rate of at-least two raters on a certain finding was 26.7%-65.2%, and complete agreement rate of all-three raters was 5.7%-43.3%. As for diagnoses, agreement of at-least two raters was 35.6%-65.6%, and complete agreement rate was 11.0%-40.0%. Agreement of findings and diagnoses were higher when restricted to images with prior complete agreement on abnormality. Retinal/glaucoma specialists showed higher agreements on findings and diagnoses of their corresponding subspecialties. Conclusion: This novel reading tool for retinal fundus images generated a large-scale dataset with high level of information, which can be utilized in future development of machine learning-based algorithms for automated identification of abnormal conditions and clinical decision supporting system. These results emphasize the importance of addressing grader variability in algorithm developments.

Depression, sleep quality, and body image disturbances among pregnant women in India: a cross-sectional study

  • Kranti S. Kadam;Aditya R. Anvekar;Vishnu B. Unnithan
    • Journal of Yeungnam Medical Science
    • /
    • 제40권4호
    • /
    • pp.394-401
    • /
    • 2023
  • Background: Pregnancy is associated with a number of physical, emotional, and biological changes that can exacerbate maternal psychological disturbances, such as body image concerns and depression. Sleep disturbances during pregnancy can also have adverse impacts. This study aimed to determine the prevalence of depression, sleep disturbances, and body image concerns among pregnant women. The study also examined the relationship between these factors and pregnancy-related variables, such as bad obstetric history and whether the pregnancies were unplanned. Methods: A cross-sectional study of 146 pregnant patients was conducted at a tertiary care center over 15 months. The patients were administered the Beck Depression Inventory, Pittsburgh Sleep Quality Index, and Body Image Concern Inventory questionnaires. Contingency tables, Fisher exact test, and Spearman correlation were used to identify underlying relationships. Results: The prevalence of depression was 22.6%. Although body image disturbance was noted in only 2.7% of patients, 46.6% had poor sleep quality. Poor sleep was associated with primigravida status. Bad obstetric history and unplanned pregnancy were associated with depression. Depression was found to be significantly correlated with body image disturbances and poor sleep quality. Conclusion: Psychiatric disorders were prevalent during pregnancy. This study highlights the importance of screening for depression in pregnant patients. Counselling and caregiver education can be useful for mitigating psychological disturbances. Management of pregnancies by multidisciplinary teams that include psychiatrists could be immensely useful in improving the pregnancy experiences of patients.

치과병원에서 사용되는 진단영상에 대한 JPEG2000 압축률에 대한 평가 (Evaluation of compression ratios using JPEG 2000 on diagnostic images in dentistry)

  • 정기훈;한원정;유동수;최순철;김은경
    • Imaging Science in Dentistry
    • /
    • 제35권3호
    • /
    • pp.157-165
    • /
    • 2005
  • Purpose : To find out the proper compression ratios without degrading image quality and affecting lesion detectability on diagnostic images used in dentistry compressed with JPEG 2000 algorithm. Materials and Methods : Sixty Digora periapical images, sixty panoramic computed radiographic (CR) images, sixty computed tomographic (CT) images, and sixty magnetic resonance (MR) images were compressed into JPEG 2000 with ratios of 10 levels from 5:1 to 50:1. To evaluate the lesion detectability, the images were graded with 5 levels (1 : definitely absent; 2: probably absent; 3: equivocal; 4: probably present; 5: definitely present), and then receiver operating characteristic analysis was performed using the original image as a gold standard. Also to evaluate subjectively the image quality, the images were graded with 5 levels (1 definitely unacceptable; 2: probably unacceptable; 3: equivocal, 4: probably acceptable; 5· definitely acceptable), and then paired t-test was performed. Results : In Digora, CR panoramic and CT images, compressed images up to ratios of 15 : 1 showed nearly the same lesion detectability as original images, and in MR images, compressed images did up to ratios of 25 : 1. In Digora and CR panoramic Images, compressed images up to ratios of 5 : 1 showed little difference between the original and reconstructed images in subjective assessment of image quality In CT images, compressed images did up to ratios of 10: 1 and in MR images up to ratios of 15 : 1 Conclusion : We considered compression ratios up to 5 : 1 in Digora and CR panoramic images, up to 10 : 1 in CT images, up to 15 : 1 in MR images as clinically applicable compression ratios.

  • PDF

작업치료과 학생들이 지각한 작업치료사의 이미지의 대한 연구 (Occupational Therapy Students Perceive Research on Image)

  • 송민옥;장아람;정명진;홍미애;장철
    • 대한통합의학회지
    • /
    • 제1권3호
    • /
    • pp.97-109
    • /
    • 2013
  • Purpose : The purpose of this study work for the therapy and how students perceive the occupational therapist was to find out how. Method : The subjects in Busan and Kyungnam located in three two-year colleges and four-year clinical experience of two college students completed work therapeutics were expressed any research to understand the purpose of those who agreed to participate in the survey responded to the 175 people working Therapeutics two, three, four grades were included in the study. Result : 1. Education according to the image of the occupational therapist in grades four-year professional, the value and worth, the patient understand the position was higher in order. 3-year sophomore highly skilled in, the patient understand the position, sincerity was higher in order. 2. Gender occupational therapist who specializes in images for men, the value and worth, high practician was higher in women who were professional, the value and worth, helfer as high. 3. Theory of motivation based on the value of occupational therapists and rewarding images aptitude and interest, high practician, attractive, intellectual was in order. Entrance examination scores as a professional party, value & worth, abuse of authority ceremony was in order. 4. Image by Place of Practice Rehabilitation Hospital occupational therapist who specializes in, high practician, intellectual was in order. Care in the hospital and rewarding value, the professional character, high practician was in order. Hospital and rewarding the value, who specializes in, hepfer was in order. University Hospital who specializes in, the value and worth, Attractive was in order. Conclusion : It had revealed that occupational image perception of occupational therapy student was positive.

두부 CT 검사 시 테이블 높이에 따른 선량과 화질에 관한 연구 (A Study on Radiation Dose and Image Quality according to CT Table Height in Brain CT)

  • 김기원;오주영;민정환;이상선;이영봉;임경환;이윤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권2호
    • /
    • pp.99-106
    • /
    • 2023
  • The height of the table should be considered important during computed tomography (CT) examination, but according to previous studies, not all radiology technologists set the table at the patient's center at the examination, which affects the exposure dose and image quality received by the patient. Therefore, this study intends to study the image quality exposure dose according to the height of the table to realize the optimal image quality and dose during the brain CT scan. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. For the exposure dose measurement, optically stimulated luminescence dosimeter (OSLD) was attached to the front, side, eye, and thyroid gland of the head phantom. In the signal to noise ratio (SNR) measurement result, The SNR values for each table height were all lower than 915 mm. As a result of exposure dose, the exposure dose on each area increased as the table height decreased. The height of the table has a close relationship with the patient's radiation exposure dose in the CT scan.