• 제목/요약/키워드: Horizontal transfer

검색결과 786건 처리시간 0.03초

계면활성제를 이용한 수평관군 흡수기의 전열촉진 (Heat Transfer Enhancement with Surfactants in Horizontal Bundle Tubes on Absorber)

  • 설원실;권오경;문춘근;윤정인
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1097-1103
    • /
    • 2000
  • This research was concerned with the enhancement of heat transfer by surfactant added to the aqueous solution of LiBr. Different horizontal tubes were tested with and without an additive of normal octyl alcohol. The test tubes were a bare tube, floral tube and hydrophilic tube. The additive mass concentration was about 0.05${\sim}$5.5%. The heat transfer coefficient was measured as a function of solution flow rate for the range of 0.01${\sim}$0.034 kg/ms. The experimental results were compared with cases without surfactant. The enhancement of heat transfer by Marangoni convection effect generated by the addition of the surfactant is observed in each test tube. The increase of heat transfer coefficient by surfactant addition is about 35${\sim}$90% for bare tube, 40${\sim}$70% for the floral tube, 30${\sim}$50% for the hydrophilic tube and was higher for the cases with smaller a little solution flow rates.

혼합냉매 R-407C의 증발 열전달과 압력강하 (Evaporation Heat Transfer and Pressure Drop of Mixture Refrigerant R-407C)

  • 노건상;오후규;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권4호
    • /
    • pp.542-549
    • /
    • 2008
  • The evaporation heat transfer coefficient and pressure drop of R-22 and R-407C in a horizontal copper tube were investigated experimentally. The main components of the refrigerant loop are a receiver, a compressor, a mass flow meter, a condenser and a double pipe type evaporator (test section). The test section consists of a smooth copper tube of 6.4 mm inner diameter. The refrigerant mass fluxes were varied from 100 to $300\;kg/m^2s$ and the saturation temperature of evaporator were $5^{\circ}C$. The evaporation heat transfer coefficients of R-22 and R-407C increase with the increase of mass flux and vapor quality. The evaporation heat transfer coefficients of R-22 is about $5.68{\times}46.6%$ higher than that of R-407C. The evaporation pressure drop of R-22 and R-407C increase with the increase of mass flux. The pressure drop of R-22 is similar to that of R-407C. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of R-22 and R-407C. therefore, it is necessary to develope reliable and accurate predictions determining the evaporation heat transfer coefficient of R-22 and R-407C in a horizontal tube.

Numerical investigation of film boiling heat transfer on the horizontal surface in an oscillating system with low frequencies

  • An, Young Seock;Kim, Byoung Jae
    • Nuclear Engineering and Technology
    • /
    • 제52권5호
    • /
    • pp.918-924
    • /
    • 2020
  • Film boiling is of great importance in nuclear safety as it directly influences the integrity of nuclear fuel in case of accidents involving loss of coolant. Recently, nuclear power plant safety under earthquake conditions has received much attention. However, to the best of our knowledge, there are no existing studies reporting film boiling in an oscillating system. Most previous studies for film boiling were performed on stationary systems. In this study, numerical simulations were performed for saturated film boiling of water on a horizontal surface under low frequencies to investigate the effect of system oscillation on film boiling heat transfer. A coupled level-set and volume-of-fluid method was used to track the interface between the vapor and liquid phases. With a fixed oscillation amplitude, overall, heat transfer decreases with oscillation frequency. However, there is a frequency region in which heat transfer remains nearly constant. This lock-on phenomenon occurs when the oscillation frequency is near the natural bubble release frequency. With a fixed oscillation frequency, heat transfer decreases with oscillation amplitude. With a fixed maximum amplitude of the additional gravity, heat transfer is affected little by the combination of oscillation amplitude and frequency.

대학 및 연구소와 산업계간 기술이전의 구성모델

  • 문병근;조규갑
    • 기술혁신연구
    • /
    • 제9권2호
    • /
    • pp.1-16
    • /
    • 2001
  • Technology transfer is recognized as a critical issue to strengthen industri competitiveness in today's global and knowledge-based economies. The vertical transfer of technology from R&D labs to industries is becoming more emphasized than the horizontal company-to-company transfer of commercialized technology. The network and cooperation among technology transfer intermediaries are becoming more important with the increasing demand of the comprehensive technology transfer services. This paper presents the configuration models for technology transfer from universities and research institutes to industries. The configuration models are classified and discussed from the viewpoint of information flow, and also technology and knowledge transfer.

  • PDF

지중열 이동 시뮬레이션을 이용한 수평형 지열시스템의 채열성능 예측 (Prediction of the Heat Exchange Rate for a Horizontal Ground Heat Pump System Using a Ground Heat Transfer Simulation)

  • 남유진;채호병
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.297-302
    • /
    • 2013
  • The ground source heat pump (GSHP) system has attracted attention, because of its stability of heat production, and the high efficiency of the system. However, there are few studies on the prediction method of the heat exchange rate for a horizontal GSHP system. In this research, in order to predict the performance of a horizontal GSHP system, coupled simulation with a ground heat transfer model and a heat exchanger circulation model was developed, and calculation of heat exchange rate was conducted by the developed tool. In order to optimally design the horizontal GSHP system, the flow rate of circulation water, and the depth and buried spaces of heat exchangers were considered by the case study. As a result, the temperature of circulation water and the heat exchange rate of the system were calculated in each case.

수평관내 초임계 영역의 Co2 냉각 열전달 특성 (Heat Transfer Characteristics During Gas Cooling Process of Carbon Dioxide in a Horizontal Tube)

  • 손창효;이동건;오후규;정시영;김영률
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.289-295
    • /
    • 2004
  • The heat transfer coefficient and pressure drop during gas cooling process of carbon dioxide in a horizontal tube were investigated. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flowmeter, an evaporator, and a gas cooler(test section). The main components of the water loop consist of a variable-speed pump, an isothermal tank, and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The test section consists of smooth, horizontal stainless steel tube of the outer diameter of 9.53mm and of the inner diameter of 7.75mm. The length of the test section is 6m. The refrigerant mass fluxes were 200∼300kg/(m2$.$s) and the inlet pressure of the gas cooler varied from 7.5㎫ to 8.5㎫. The main results were summarized as follows : Pressure drop of CO2 increases with increasing gas cooler pressure. The friction factors of CO2 in a horizontal tube show a relatively good agreement with the correlation by Blasius. The heat transfer coefficient of CO2 in transcritical region increases with decreasing gas cooler pressure and decreasing mass flux of CO2. Most of correlations proposed in a transcritical region showed significant deviations with experimental data except for those predicted by Gnielinski.

수평 가까운 튜브 표면의 평균 풀비등 열전달계수의 측정 (Measurement of Average Pool Boiling Heat Transfer Coefficient on Near-Horizontal Tube)

  • 강명기
    • 대한기계학회논문집B
    • /
    • 제38권1호
    • /
    • pp.81-88
    • /
    • 2014
  • 수평에 가깝게 설치된 튜브 원주면에 대해 평균 열전달계수를 결정하기 위한 실험적 연구를 수행하였다. 실험을 위하여 대기압 상태하의 물속에 잠긴 50.8 mm의 스테인리스강 튜브를 사용하였다. 과냉 및 포화 풀비등 조건을 모두 고려하였으며, 튜브 경사각은 수평으로부터 $9^{\circ}$까지 $3^{\circ}$ 간격으로 변경하였다. 포화상태에서는 튜브의 최하부로부터의 방위각이 $90^{\circ}$인 위치에서 측정한 국소비등열전달계수가 평균값으로 취급될 수 있으며, 이러한 경향은 튜브 경사각과는 무관함을 확인하였다. 그러나 물이 과냉상태인 경우, 평균 열전달계수의 위치는 경사각과 열유속에 의존한다. 열전달을 변화시키는 주된 열전달 기구는 액체교란 강도 및 기포군집에 의한 큰 기포 덩어리의 형성과 밀접한 관계가 있는 것으로 설명된다.

초임계 영역에서 수평관내 $CO_2$ 열전달과 압력강하 (The heat transfer and pressure drop characteristics of $CO_2$ during supercritical region in a horizontal tube)

  • 이동건;오후규;김영률;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.500-508
    • /
    • 2004
  • The heat transfer coefficients during gas cooling process of carbon dioxide in a horizontal tube were investigated. The experiments are conducted without oil in the refrigerant loop. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater, and a gas cooler(test section). The water loop consists of a variable-speed pump, an isothermal tank, and a flow meter. The gas cooler is a counterflow heat exchanger by cooled water flowing in the annulus. The $CO_2$ flows in the horizontal stainless steel tube. which is 9.53mm in O.D. and 7.75mm in I.D. The gas cooler is 6 [m] in length. which is divided into 12 subsections, respectively. The experimental conditions considered in the study are following range of variables : refrigerant temperature is between 20 and $100^{\circ}C$. mass fluxes ranged from 200 to 400kg/($m^2$.s), average pressure varied from 7.5 to 10.0MPa. The main results were summarized as follows : The friction factors of $CO_2$ in the gas cooler show a relatively good agreement with those predicted by Blasius' correlation. The local heat transfer coefficient in the gas cooler has compared with most of correlations, which are the famous ones for forced convection heat transfer of turbulent flow. The results show that the local heat transfer coefficient of gas cooler agrees well with the correlation by Bringer-Smith except that at the region near pseudo critical temperature. while that at the near pseudo critical temperature is higher than the correlation.

미세 수평 사각 유로에서의 비등 열전달에 대한 실험적 연구 (An Experimental Study on Flow Boiling Heat Transfer within Horizontal Rectangular Channels with Small Heights)

  • 이상용;이한주
    • 대한기계학회논문집B
    • /
    • 제25권9호
    • /
    • pp.1209-1218
    • /
    • 2001
  • The present paper proposes a new correlation for the flow boiling heat transfer coefficients in the low flow rate condition (Re(sub)LF$\leq$200) within horizontal rectangular channels with small gaps (heights). The gap between the upper and the lower plates of each channel ranges from 0.4 to 2mm while the channel width being fixed to 20mm. Refrigerant 113 was used as the test fluid. The mass flux ranges from 50 to 200kg/㎡s and the channel walls were uniformly heated with the heat flux range of 3-15kW/㎡. The quality range covers from 0.19 to 0.76 and the flow pattern is considered to be annular. The measured heat transfer coefficients increase with the mass flux and the local quality; however the effect of the heat flux appears to be minor. At the low mass flux condition, which is more likely with the smaller gap size, the heat transfer is primarily controlled by the liquid film thickness. The proposed F factor for the heat transfer coefficient in the range of Re(sub)LF$\leq$200 well represents the experimental data within the deviation of $\pm$20%. The Kandlikars flow boiling correlation covers the higher flow-rate range(Re(sub)LF>200) within the deviation of $\pm$20%.