• Title/Summary/Keyword: Horizontal Position

Search Result 918, Processing Time 0.027 seconds

Kinematical Analysis of El-grip swing with 1turn to el-grip in horizontal bar (철봉 어깨 틀어 휘돌아 다시 잡기(el-grip swing with one turn to el-grip) 동작의 운동학적 분석)

  • Kim, Jae-Phil
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.1
    • /
    • pp.51-62
    • /
    • 2003
  • This study was attempted to kinematical characteristics of the El-grip swing with 1turn to el-grip in elite horizontal bar for the purpose of improving performance. The subjects were three males who were 2002 Busan Asian Games in men's team. The three dimensional motion analysis with DLT method was executed using three video cameras of analyzing the actual competition situation. In point of analyzing the actual competition situation, it is expected that gymnastics and coaches have the effective informations, and the following conclusion had resulted. 1. In case of release, It is impotant to make fast horizontal velocity of CM, high vertical position of CM, large hip and shoulder angle. Also It should be performed release motion of trunk rotation angle(+). 2. During LHR the action should be made at higher position than the CM and the shoulder joint is moving within $127{\pm}16.82$. It is important to make large lunk rotation angle. 3. During Hop, the RHR motion should be done in high position with short time and fast twisting action and to reduce the vertical speed is important.

A RADIOGRAPHIC STUDY OF TONGUE POSTURE AT REST POSITION AND DURING THE PHONATION OF /S/ IN CLASS III MALOCCLUSION (제III급 부정교합자의 안정위시와 /s/ 발음시 혀의 위치에 관한 두부방사선계측학적 연구)

  • Lee, Ky-Heon;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.23 no.2 s.41
    • /
    • pp.179-197
    • /
    • 1993
  • Tongue posture at rest position of Class III malocclusion is very important in malocclusion and phonation. Because Class III malocclusion shoves low tongue position, speech defect is commonly occured. This study was attempted to evaluate the correlationship between the tongue posture at rest position and during /s/ phonation and facial skeleton in centric occlusion. Thirty subjects with Class III malocclusion who had no orofacial defects such as cleft palate, medical history of neurologic pathology, hearing defect and any previous speech therapy were selected. Ninety sheets of lateral cephalometric radiographs taken at rest position, during /s/ phonation and centric occlusion were traced, measured and statistically analysed. The results obtained were as follows ; 1. In Class III malocclusion, the posture of tongue was positively correlated with the position of hyoid body. The hyoid body was positioned anteriorly and inferiorly as the vertical facial skeleton was increased in centric occlusion. 2. In Class III malocclusion, the vertical position of tongue tip at rest position was not correlated with facial skeleton in centric occlusion, but the horizontal position had low correlation with mandibular body length, APDI, and $\underline{1}$ to SN. 3. In Class III malocclusion, there was the tendency that the dorsal position of the tongue was lowered as the vertical facial skeleton was increased. 4. In Class III malocclusion, the vertical and horizontal position of tongue tip during /s/ phonation was not correlated with facial skeleton in centric occlusion.

  • PDF

Study on the Simultaneous Control of the Seam Tracking and Leg Length in a Horizontal Fillet Welding Part 2: Seam Tracking

  • Moon, H.S.;Na, S.J.
    • International Journal of Korean Welding Society
    • /
    • v.1 no.1
    • /
    • pp.31-38
    • /
    • 2001
  • For the horizontal fillet welding with one plate in a vertical position, there will be a higher tendency of weld metal falling down rather than for the butt-welding in flat position. Such phenomenon could bring about the overlap or deflection of weld pool, and consequently induce the poor mechanical strength of weldments. Therefore, a precise position control of welding torch in conjunction with the weld qualify plays an important role in welding robot applications. In the present study, an experimental method was proposed for deriving a mathematical model between the leg length and the welding conditions. Finally, an algorithm was proposed for weld seam tracking and improvement of the weld quality. The reliability of the proposed algorithm was evaluated through various experiments, which showed that the proposed algorithm can be very effective for tracking the weld line and simultaneously achieving the sound weld bead.

  • PDF

A PROPORTIONAL ANALYSIS OF SOFT TISSUE PROFILE IN KOREAN YOUNG ADULTS (성인 정상 교합자의 연조직 비율에 관한 두부 X-선 계즉학적 분석)

  • Lee, Jeong-Hwa;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.24 no.2
    • /
    • pp.405-417
    • /
    • 1994
  • The purpose of this study was to investigate proportional characteristics of soft tissue profile in Korean young adults. The sample consisted of 50 young adults(25 males and 25 females) who had pleasing profile and normal occlusion. Soft tissue proportional analysis was performed on lateral cephalograms taken in natural head position. The results were as follows : 1. Mean and standard deviation of proportional analysis were obtained. 2. Horizontal and vertical dimensions were larger in male. But facial proportion had no sexual difference except upper/lower face height (p<0.05). Upper/lower face height was larger in female than in male. 3. Vertical dimensions, except SN-ST, had high correlation with horizontal dimensions. 4. Head positioning error of natural head position was smaller than inter -individual variability of SN line.

  • PDF

Influence of tooth position within the field of view on the intensity of cone-beam computed tomographic imaging artifacts when assessing teeth restored with various intracanal materials

  • de Oliveira Pinto, Martina Gerlane;Melo, Saulo Leonardo Sousa;Cavalcanti, Yuri Wanderley;de Lima, Elisa Diniz;Bento, Patricia Meira;de Melo, Daniela Pita
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.141-151
    • /
    • 2020
  • Purpose: This study aimed to quantify the influence of tooth position within the field-of-view (FOV) on cone-beam computed tomography (CBCT) imaging artifacts' intensity when assessing teeth restored with various intracanal materials. Materials and Methods: Seventy single-rooted teeth were divided into 7 groups (10 teeth per group): NiCr post (NC), AgPd post (AP), metal core fiberglass post (MCFG), fiberglass post (FG), anatomical fiberglass post (AFG), fiberglass post cemented with core build-up cement (FGCo), and anatomical fiberglass post cemented with core build-up cement (AFGCo). All posts were cemented using a regular dual-curing resin cement (Allcem), except FGCo and AFGCo which were cemented with a core build-up dual-curing resin cement (AllcemCore). Each tooth was scanned on a CS9000 in 5 positions within the FOV: a central position, anterior horizontal peripheral, peripheral superior, peripheral inferior, and posterior horizontal peripheral position. Hyperdense, hypodense, remaining teeth areas and ROI areas were quantitatively analyzed using ImageJ software. Results: Posterior horizontal peripheral position increased the intensity of artifacts on FGCo and AFGCo post groups (P<0.05), and specifically the hypodense artifact intensity on FG and AFG post groups (P<0.05). NC and AP groups presented greater intensity of artifacts than any other post groups(P<0.05). Conclusion: Artifact intensity increases in the presence of high atomic number materials and when the object is not centered within the FOV. The impact of positioning within the FOV on artifact was greater for fiberglass posts cemented with core build-up dual-curing cement than for metal posts and fiberglass posts cemented with regular dual-curing cement.

Analysis of Position Accuracy of Topography using LiDAR Data (LiDAR 데이터를 이용한 지형지물의 위치정확도 분석)

  • Kim, Yong-Suk;Kim, Seong-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.3
    • /
    • pp.270-278
    • /
    • 2008
  • This study : An analysis of position accuracy of topography according to using LiDAR data, aerial photo and digital map for a study area was conducted. The study area was selected in Hadan area, Sahagu, Busan aerial LiDAR data and aerial photo in the scales of 1:20,000, which are high tech surveying ways were used. The final digital orthoimage according to orientation process for each image and image resampling was producted. Using it, a checkpoint was chosen, information about the checkpoints selected was extracted, a coordinate of Horizontal Position through the screen digitizing was also extracted. Both the coordinates of LiDAR data and aerial photo using digital map in the scales of 1:20,000 announced to the public from NGII(National Geographic Information Institute) were gradually compared and analyzed. Based on the digital map, as a result of being both compared and analyzed, it has shown to us that horizontal position of aerial photo is more accurate than that of aerial LiDAR surveying (RMSE-building x:24cm, y:26cm).

Estimation of Stellate Ganglion Block Injection Point Using the Cricoid Cartilage as Landmark Through X-ray Review

  • Park, Jeong-Soo;Kim, Ki-Jun;Lee, Youn-Woo;Yoon, Duck-Mi;Yoon, Kyung-Bong;Han, Min-Young;Choi, Jong-Bum
    • The Korean Journal of Pain
    • /
    • v.24 no.3
    • /
    • pp.141-145
    • /
    • 2011
  • Background: Stellate ganglion block is usually performed at the transverse process of C6, because the vertebral artery is located anterior to the transverse process of C7. The purpose of this study is to estimate the location of the transverse process of C6 using the cricoid cartilage in the performance of stellate ganglion block. Methods: We reviewed cervical lateral neutral-flexion-extension views of 48 patients who visited our pain clinic between January and June of 2010. We drew a horizontal line at the surface of the cricoid cartilage in the neutral and extension views of cervical lateral x-rays. We then measured the change in the shortest distance from this horizontal line to the lowest point of the transverse process of C6 between the neutral and extension views. Results: There was a statistically significant difference in the shortest distance from the horizontal line at the surface of the cricoid cartilage to the lowest point of transverse process of C6 between neutral position and neck extension position in both males and females, and between males and females in both neutral position and neck extension position. The cricoid cartilage level was 4.8 mm lower in males and 14.4 mm higher in females than the lowest point of transverse process of C6 in neck extension position. Conclusions: Practitioners should recognize that the cricoid cartilage has cephalad movement in neck extension. In this way, the cricoid cartilage can be still useful as a landmark for stellate ganglion block.

A Study on the Position and Length of the Maxillary Central Incisor in Koreans (한국인의 상악중절치 위치 및 길이에 관한 연구)

  • Shin, Sang-Wan;Heo, Yun-Seok
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.5 no.1
    • /
    • pp.1-12
    • /
    • 1996
  • The arrangement of anterior artificial teeth is an important factor on the esthetics in the construction of complete dentures and prostheses. During construction of the complete denture the position of maxillary central incisor plays an important role in the arrangements of artificial teeth. The proper position of maxillary central incisor provides natural appearance of anterior teeth and the anterior reference point of occlusal plane. Many methods have been utilized to eatablish the position of the maxillary central incisor in complete denture prosthodontics. However, there has not been provided for the reference for Korean yet. This study was aimed to extablish a guide for the position of the maxillary central inciosr in Koreans. The horizontal and vertical distance between the maxillary central incisor and incisive papilla in Koreans were measured. 1. The mean value of horizontal distance from the maxillary central incisor to the incisive papilla had significant sexual difference, The average distance was 12.648mm in male and 11.385mm in female. 2. The horizontal distance of the incisive papilla had sexual difference, the average distance was 6.182mm in male and 5.622mm in female. 3. The vertical distance from the maxillary central incisor to the incisive papilla had not sexual difference, the average distance was 7.21mm. 4. The crown length of the maxillary central inciosrs from the distal interdental papilla had not sexual difference, the right central incisor was 6.40mm(mean) and the left central inciosr was 6.43mm(mean). 5. The clinical crown length of the maxillary central incisors had not sexual difference, the right central incisor 10.35mm(mean) and the left central incisor was 10.43mm(mean). 6. The shapes of the incisive papilla were pear(68.4%), oval(16%), triangular(6%), irregular(5%), rectangular(4%), and inverted pear(1%) shape.

  • PDF

Development of a position sensitive CsI(Tl) crystal array

  • Shi, Guo-Zhu;Chen, Ruo-Fu;Chen, Kun;Shen, Ai-Hua;Zhang, Xiu-Ling;Chen, Jin-Da;Du, Cheng-Ming;Hu, Zheng-Guo;Fan, Guang-Wei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.835-840
    • /
    • 2020
  • A position-sensitive CsI(Tl) crystal array coupled with the multi-anode position sensitive photomultiplier tube (PS-PMT), Hamamatsu H8500C, has been developed at the Institute of Modern Physics. An effective, fast, and economical readout circuit based on discretized positioning circuit (DPC) bridge was designed for the 64-channel multi-anode flat panel PSPMT. The horizontal and vertical position resolutions are 0.58 mm and 0.63 mm respectively for the 1.0 × 1.0 × 5.0 ㎣ CsI(Tl) array, and the horizontal and vertical position resolutions are 0.86 mm and 0.80 mm respectively for the 2.0 × 2.0 × 10.0 ㎣ CsI(Tl) array. These results show that the CsI(Tl) crystal array with low cost could be applied in the fields of medical imaging and high-resolution gamma camera.

Application of the Terrestrial Photogrammetric for Railway Alignments Reconstruction (철도 선형 복원을 위한 지상사진측량의 적용)

  • Lee Jong-Chool;Park Woon-Yong;Kang In-Jun;Jang Ho-Sik
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.265-269
    • /
    • 2006
  • In this study, horizontal alignment of railroad obtained by digital photogrammetry method. The two-dimensional horizontal alignment was reappeared by camera calibration and digital image data. This method's result showed more satisfactory value than existing survey method in horizontal alignment of railroad. Hereafter, this method would be a appropriate method lot the decision of railroad facility' position in small rural area and construction of DB for the design of alignment.

  • PDF