• 제목/요약/키워드: Horizontal Illuminance

검색결과 35건 처리시간 0.029초

천공구분에 따른 서울지역 일사의 발광효율 측정 및 예측모델과의 비교 연구 (Comparison of Measurement and Calculation Model of Solar Luminous Efficacy for All Sky Conditions in Seoul)

  • 윤갑천;윤경;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.86-94
    • /
    • 2011
  • For accurate dayligh tsimulation, accurate exterior illuminance is necessary. But, Korea Meteorological Agency provides only the solar irradiance data. Thus, there is a need for the research on luminous efficacy. In this study, global horizontal irradiance, diffuse horizontal irradiance, global horizontal illuminance, and diffuse horizontal illuminance were measured to calculate the luminous efficacy in SEOUL. And, we evaluated the applicability of the Perez's model by comparing the measured data and calculated data. As a result, measured global luminous efficacy is 126(110~129)lm/W and diffuse luminous efficacy is 127(115~133)lm/W in Seoul. Perez's model was relatively accurate with 5% difference in the diffuse luminous efficacy. But, it can be predicted about 15% lower in the global luminous efficacy.

소규모 사무실의 블라인드 조건에 따른 주광조도 감소비율 예측 (Prediction of Reduction Rates of Daylight Illuminance for Blind Conditions in a Small Office)

  • Gu, Renyan
    • 토지주택연구
    • /
    • 제12권2호
    • /
    • pp.79-89
    • /
    • 2021
  • 본 연구는 다른 창가 방향에 따라 소규모 개인 사무실의 바닥과 천장의 수평 일광 분포를 분석하였다. 시뮬레이션에는 블라인드를 추가하여 다양한 일광 조도를 분석하고 비교할 수 있는 세 가지 음영 조건을 설정했다. 일광 조도 시뮬레이션을 위한 소프트웨어는 Relux였다. 실험 결과 창가에서 1m 떨어진 곳에서 조도 값이 가장 높았고 거리가 가까울수록 조도 값이 높았다. 바닥과 천장에서는 조도 차이가 12월과 6월에 각각 가장 크고 작았다. 실내 조도 값은 블라인드가 없을 때 가장 높았고, 남향 조건에서는 조도의 45°와 수평 블라인드의 차이가 가장 컸다. 북쪽 조건에서는 45°와 무 블라인드가 실내 조도에 가장 적은 영향을 미치며, 조도가 더 고르게 분배되었다.

광속법을 이용한 등배치 설계에 관한 연구 (A Study On the Design of Balaced Illuminance Using Lumen Flux Method)

  • 최홍규;최병숙;정성윤;김진성
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.175-180
    • /
    • 1999
  • This paper presents the effective design of the change of average illuminance and the arrangement of lamps by changing the form of working area and adjusting the distance between the wall and light. This study is intended to simplify the complex calculation of illuminance through the development of application program. It's plan to study application programs that can attain the value of advanced uniformly-distributed illuminance and average illuminance by changing the distance between the horizontal/vertical wall and lamp and between the horizontal/vertical lamp and lamp.

  • PDF

VBA(Visual Basic for Applications)를 활용한 실외 수직면 조도 간이계산법에 관한 연구 (A Study of Simplified Calculation Methods for Outside Vertical Illuminance using VBA)

  • 윤수인;김강수
    • 대한건축학회논문집:구조계
    • /
    • 제34권12호
    • /
    • pp.65-72
    • /
    • 2018
  • The purpose of this study is to predict vertical illuminance accurately at the design stage of a building without the help of simulation tools. Comparing two well-known vertical illuminance prediction algorithms with measured values, it is verified that the Igawa model is more consistent with the measured values than the Perez model. Using the DIVA program, we simulated the vertical illuminance at 30-degree intervals from south to north, compared with the vertical illuminance calculated with the Igawa model. The result of calculation values were verified from 120 degrees east to 120 degrees west. The vertical illuminance values with each of three shade devices were calculated using the Igawa model, and compared with the vertical illuminance simulated by DIVA program. As a result, all the errors when installing horizontal / vertical / grid shade divices were included in the error standard specified by ASHRAE.

축구 경기장의 조명타워 위치에 따른 조도분포 해석 (Illuminance Distribution Analysis by Lighting Tower Position of o Soccer Stadium)

  • 김길영;최홍규;최병숙
    • 조명전기설비학회논문지
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2004
  • 오늘날 축구는 세계적인 주목을 받는 스포츠가 되었다. 특히, 2002 KOREA-JAPAN 월드컵은 한국에 대한 깊은 인상을 심어 주었다. 축구경기장의 조명시스템 설계에 있어서 가장 주요한 기술적 목적은 경기장의 어디에서나 최적의 분포를 나타내도록 하는 것이다. 이렇듯, FIFA는 경기장의 어디에서나 선수, 청중, 방송관계자등에게 일정한 수준의 조도를 제공할 수 있도록 규정하고 있다. 본 논문에서는 경기장의 조명타워의 위치선정에 따른 최적의 수평면 조도와 수직면 조도를 찾기 위한 알고리즘을 제시하였다. 본 논문에서는 Philip's Calculux 프로그램을 이용하여 조명타워의 위치에 따라 수평면 조도, 수직면 조도, 균제도, 글레어 등을 계산하였다.

천공 및 차양조건에 따른 소규모 사무실의 주광 조도 감소범위 예측 (The prediction of reduction ranges of daylight illuminance in small office for sky and shading conditions)

  • 장서연
    • 토지주택연구
    • /
    • 제10권3호
    • /
    • pp.33-41
    • /
    • 2019
  • This study examines the distributions of daylight illuminance in a small office space under clear and cloudy sky conditions. Three shading conditions using Venetian blinds were applied for the analysis of daylight illuminance. Computer simulations using the Lightscacpe were conducted for the daylight conditions applied to the office space. Results indicate that the illuminance differences between clear and cloudy sky for south-facing conditions were greater than those for north-facing conditions. The differences in December and June were the greatest and smallest, respectively. For the north-facing conditions, the daylight illuminance at 10:00, 12:00 and 14:00 in June and September under the cloudy sky was higher than those under the clear sky conditions. For all daylight conditions, the biggest amount of illuminance reduction occurred when the shading device conditions were changed from the no blind to the 45 degree blinds. As the distance from window increased, the shading effect that occurred when the shading device conditions were changed from the horizontal blind to the 45 degree blinds increased.

태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가 (Assessment of Daylight Environment on Light Pipe System Under Different Solar Position)

  • 신화영;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.78-86
    • /
    • 2008
  • The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

야간상업가로의 조명물리량 및 이미지 분석 - 보행자 시점을 기준으로 - (Analysis on Luminous Environment and Subjective Image of Two Different Commercial Streets at Night - Focused on View Point of Pedestrian -)

  • 신주영;김정태
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.31-38
    • /
    • 2007
  • Streetscape plays on important role in urban cities. Characteristics of streets is basically defined by the building facade, signs, plants and paving during the daytime. However at night, street receives a new appearance due to the shop light from the buildings, exterior lightings, signboards and street light, and it creates most of the image of the streets. This study aims to analyze the luminous environment and its subjective image of two different pedestrian's commercial streets. Insa-dong street and Myungdong street were chosen for the study. Horizontal illuminance and luminance on building surface, advertisement billboards and pedestrian road were measured. Thirty students were asked to rate the five scaled questionnaire on their subjective images of the streets. Statistical analysis including profile, correlation and T-test are conducted and some findings are discussed

거울형 태양광 채광시스템의 실제 건축물 적용에 따른 실내주광조도 평가 (Indoor Illuminance Evaluation on a Mirror Sunlighting System Applied to the Apartments under Real Sky Condition)

  • 정주희;김정태
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.137-145
    • /
    • 2010
  • Active sunlighting systems have been applied to deliver sunlight into the indoor space where natural light is insufficient, mainly because of the congested high-rise buildings in urban areas. Among various active sunlighting systems, a mirror sunlighting system which is simple structure and economically reasonable has been widely used in different types of spaces such as underground, north facing place and atrium. This study was to evaluate the mirror sunlighting systems, which were consisted of the first mirror of $3.5m{\times}2.5m$, the eight sets of the second mirrors of $1.0m{\times}1.25m$ and a sun tracker. Ten sets of the systems were installed for 40 apartment living rooms, the configuration of $3.5m(W){\times}4.0m(D){\times}2.5m(H)$ where sunlighting were not possible due to high retaining walls located in the front of the living rooms. The 45 HOBO data logger sensors for the indoor illuminance were equipped and 2 Li-cor photometers for outdoor illuminance. Both indoor and outdoor horizontal illuminances were monitored every second from 9am to 3pm on 17 January 2010 under clear sky condition. The results showed that the indoor illuminance of installed mirror sunlighting system was significant relationship with outdoor illuminance and increased the indoor illuminance level by 4.2 times on the whole floor space, by 8 times on the sun patch space of 6m2 and even by 2 times on the no sun patch space. In addition, the luminous conditions of the living room under real sky conditions met the KS recommendation for difficult task (600-1000-1500 lux) such as sewing and reading on whole floor space and sun patch space. It was proved that the benefits of mirror sunlighting systems included an effective technology for penetrating daylight into indoors where sunlighting was not possible and improving occupants' satisfaction and health, and contributing to energy saving in apartments during daytime.

천공상태에 따른 수직형 광파이프 시스템의 채광성능 평가 (Daylighting Performance of Lightpipe under Different Sky Conditions)

  • 공효주;김정태
    • KIEAE Journal
    • /
    • 제8권3호
    • /
    • pp.101-106
    • /
    • 2008
  • The use of daylighting has been increased recently due to energy and visual comfort. The aims of interior daylighting are to adequately illuminate visual tasks, to create an attractive visual environment, and to save electrical energy. Lightpipe can improve the distribution of light to interior spaces. This study aims to evaluate the comparative daylighting performance of lightpipe under different sky conditions with mock-up model, sized $6m{\times}6m{\times}4m$ ($w{\times}d{\times}h$). For the purpose, perpendicular lightpipe system was designed as 650 diameter, with an aspect ratio of 2. Totally 49 measuring points of and two of outdoor illuminance on the horizontal plane were monitored from 09:00 to 18:30 on April 29 and May 15 2008. Agilent data logger and photometric sensor were used. Light factor were used to analyse daylight performance under different sky condition. Under overcast sky condition and clear sky condition, the lightpipe system is suitable for KS recommendation level of illuminance.