• Title/Summary/Keyword: Homogeneity analysis

Search Result 660, Processing Time 0.027 seconds

Characteristics of the Expanded Road Embankment Constructed by Lightweight Air-Mixed Soils for a Short-Term (경랑기포혼합토로 단기간에 시공된 확폭도로성토체의 특성)

  • Hwang, Joong Ho;Ahn, Young Kyun;Lee, Young-Jun;Kim, Tae-Hyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4D
    • /
    • pp.377-386
    • /
    • 2010
  • This study was conducted to find out the characteristics of the expanded road embankment constructed by the lightweight air-mixed soil (slurry density $10kN/m^3$) for a short-term without any ground improvement. Compression strength, capillary rise height of the lightweight air-mixed soil and settlement behavior of soft ground were studied. Compression strengths of the specimens sampled at the site after 1 and 5 months of construction were all satisfied the required strength 500 kPa. However, it was not convinced the homogeneity construction, because the values of strength were depending on the sampled location. Also, strength difference between laboratory and site specimens were found about 19%, and thus it should be considered for mixing design. Capillary rise reached about 20 cm for 70 hours because of a numerous tiny pores existed inside the lightweight air-mixed soil. Relationship between settlement and time of the soft ground placed underneath the expanded embankment was estimated by using the measured data and back analysis technique. The current average consolidation ratio and the final settlement after 120 months later were estimated about 32% and 4.5cm, respectively. This settlement is much less value than the allowable settlement 10cm for this structure.

Ecological Factors Influencing the Bird Diversity on Baekdudaegan Protected Area Cheonwangbong to Aghwibong Region (백두대간보호지역의 천왕봉에서 악휘봉 구간에 서식하는 조류의 다양성에 영향을 주는 생태적 요인)

  • Hyun-Su Hwang;Doory No;Yunkyoung Lee
    • Korean Journal of Environment and Ecology
    • /
    • v.38 no.1
    • /
    • pp.48-54
    • /
    • 2024
  • This study conducted a survey from April 2021 to December 2022 to investigate habitat factors affecting bird diversity in the region between Cheonwangbong Peak and Aghwibong in Baekdudaegan protected area, South Korea. Since the region has a spatial scale of 736.4 km2 and is an area where a wide variety of habitats are mixed, we selected 20 survey areas of 3 km x 3 km by analysis of habitat homogeneity. As a result of analyzing the relationship between habitat environment and bird diversity in the survey area, it was found that the diversity of bird communities was directly or indirectly related to the diversity of terrestrial insects, slope, average habitat area, mean size of patches, elevation, and forest type, and distance from agricultural land. The slope of habitat, forest type, and distance from agricultural land affect the occurrence of food sources directly and indirectly, and the average area of habitats and forest type is closely related to the structural diversity of habitats. Therefore, it is determined that the diversity of bird communities is affected by the amount of food generated within the habitat and the diversity of habitats. It is determined that the relationship between bird communities and habitat environments in this surveyed region can be basic ecological data for establishing forest management measures to promote the diversity of bird communities.

'Han of the Class' based on the Relationship between Character and Non-Character Symbols - on the Film of Bong Joon-ho - (인물 기호와 비인물 기호 관계를 바탕으로 한 '계급의 한' -봉준호 영화를 중심으로-)

  • Song-lin Zhao;Yoojin Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.2
    • /
    • pp.323-331
    • /
    • 2024
  • The concept of 'Han' is a psychological characteristic formed by Koreans through long-lasting national hardships. It has deeply influenced every Korean as a form of collective unconscious and has merged with various forms of art over time. Director Bong Joon-ho's works, rich in social consciousness, symbolically visualize sensitive issues like social class, presenting harsh satire on class oppression. His movies continuously emphasize human desires, the homogeneity of good and evil, insurmountable class barriers, and moral decay caused by desires. They produce a wealth of symbols filled with layers and power dynamics. Bong Joon-ho dramatically portrays and directs various forms of symbols. The metaphorical symbols in his movies provide a unique research value for delving into the deeper meanings of the films.This study examines the theme of 'class Han' in six of Bong Joon-ho's films, exploring the 'Han culture' of Korea. It applies semiotic concepts by categorizing into character and non-character symbols for an in-depth analysis of the films. The representative works from the late 1990s to the late 2010s articulate the class layers of the 'visible' and the 'invisible' through a blend of realism and surrealism. The study analyzes Bong Joon-ho's films in the sequence of 'satire-exposure-hope', examining the culturally critical nature of 'Han culture' on class and its psychological and cultural impact on the general public.

Impact of Photon-Counting Detector Computed Tomography on Image Quality and Radiation Dose in Patients With Multiple Myeloma

  • Alexander Rau;Jakob Neubauer;Laetitia Taleb;Thomas Stein;Till Schuermann;Stephan Rau;Sebastian Faby;Sina Wenger;Monika Engelhardt;Fabian Bamberg;Jakob Weiss
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.1006-1016
    • /
    • 2023
  • Objective: Computed tomography (CT) is an established method for the diagnosis, staging, and treatment of multiple myeloma. Here, we investigated the potential of photon-counting detector computed tomography (PCD-CT) in terms of image quality, diagnostic confidence, and radiation dose compared with energy-integrating detector CT (EID-CT). Materials and Methods: In this prospective study, patients with known multiple myeloma underwent clinically indicated whole-body PCD-CT. The image quality of PCD-CT was assessed qualitatively by three independent radiologists for overall image quality, edge sharpness, image noise, lesion conspicuity, and diagnostic confidence using a 5-point Likert scale (5 = excellent), and quantitatively for signal homogeneity using the coefficient of variation (CV) of Hounsfield Units (HU) values and modulation transfer function (MTF) via the full width at half maximum (FWHM) in the frequency space. The results were compared with those of the current clinical standard EID-CT protocols as controls. Additionally, the radiation dose (CTDIvol) was determined. Results: We enrolled 35 patients with multiple myeloma (mean age 69.8 ± 9.1 years; 18 [51%] males). Qualitative image analysis revealed superior scores (median [interquartile range]) for PCD-CT regarding overall image quality (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), edge sharpness (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), image noise (4.0 [4.0-4.0] vs. 3.0 [3.0-4.0]), lesion conspicuity (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), and diagnostic confidence (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]) compared with EID-CT (P ≤ 0.004). In quantitative image analyses, PCD-CT compared with EID-CT revealed a substantially lower FWHM (2.89 vs. 25.68 cy/pixel) and a significantly more homogeneous signal (mean CV ± standard deviation [SD], 0.99 ± 0.65 vs. 1.66 ± 0.5; P < 0.001) at a significantly lower radiation dose (mean CTDIvol ± SD, 3.33 ± 0.82 vs. 7.19 ± 3.57 mGy; P < 0.001). Conclusion: Whole-body PCD-CT provides significantly higher subjective and objective image quality at significantly reduced radiation doses than the current clinical standard EID-CT protocols, along with readily available multi-spectral data, facilitating the potential for further advanced post-processing.

The Study of Error for Analysis in Dynamic Image from the Error of Count Rates in NaI (Tl) Scintillation Camera (NaI (Tl) 신틸레이션 카메라에서 계수율 오차에 따른 동적 영상 분석치 산출 오류에 관한 연구)

  • Oh, Joo-Young;Kang, Chun-Goo;Kim, Jung-Yul;Park, Hoon-Hee;Oh, Ki-Baek;Kim, Jae-Sam
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.291-297
    • /
    • 2013
  • This study is aimed to evaluate the effect of $T_{1/2}$ upon count rates in the analysis of dynamic scan using NaI (Tl) scintillation camera, and suggest a new quality control method with this effects. We producted a point source with $^{99m}TcO_4^-$ of 18.5 to 185 MBq in the 2 mL syringes, and acquired 30 frames of dynamic images with 10 to 60 seconds each using Infinia gamma camera (GE, USA). In the second experiment, 90 frames of dynamic images were acquired from 74 MBq point source by 5 gamma cameras (Infinia 2, Forte 2, Argus 1). There were not significant differences in average count rates of the sources with 18.5 to 92.5 MBq in the analysis of 10 to 60 seconds/frame with 10 seconds interval in the first experiment (p>0.05). But there were significantly low average count rates with the sources over 111 MBq activity at 60 seconds/frame (p<0.01). According to the second analysis results of linear regression by count rates of 5 gamma cameras those were acquired during 90 minutes, counting efficiency of fourth gamma camera was most low as 0.0064%, and gradient and coefficient of variation was high as 0.0042 and 0.229 each. We could not find abnormal fluctuation in $x^2$ test with count rates (p>0.02), and we could find the homogeneity of variance in Levene's F-test among the gamma cameras (p>0.05). At the correlation analysis, there was only correlation between counting efficiency and gradient as significant negative correlation (r=-0.90, p<0.05). Lastly, according to the results of calculation of $T_{1/2}$ error from change of gradient with -0.25% to +0.25%, if $T_{1/2}$ is relatively long, or gradient is high, the error increase relationally. When estimate the value of 4th camera which has highest gradient from the above mentioned result, we could not see $T_{1/2}$ error within 60 minutes at that value. In conclusion, it is necessary for the scintillation gamma camera in medical field to manage hard for the quality of radiation measurement. Especially, we found a tendency that count rate changes over time at this study, and we proved that it can effect $T_{1/2}$. And also, there is need of appropriate phantoms and the method of quality management like this study, because there are not any advice or limitation degrees for domestic medical purpose scintillation camera.

Analysis of the Characteristics of Container Ports in Busan Port Using Industrial Organization Approach (산업조직론을 활용한 부산항 컨테이너 하역산업의 특성 분석)

  • Ko, Byoung-Wook;Kil, Kwang-Soo;Lee, Da-Ye
    • Journal of Korea Port Economic Association
    • /
    • v.37 no.3
    • /
    • pp.117-128
    • /
    • 2021
  • In order for the users (shipping firms and shippers) and suppliers (stevedoring firms) in the container terminal industry to win-win, it is necessary to have some appropriate diverse market conditions for the industry. This study analyses the basic conditions and demand and supply characteristics of the industry and investigates the market performance of Busan container ports. First, this article analyses the basic characteristics of demand and supply. As the demand characteristics, there are five ones such as 1) exogeneity of demand, 2) function as export/import transportation and hub for transshipment, 3) increase of users' bargaining power, 4) high substituting elasticity, 5) reduction of volume growth. As the supply characteristics, there are seven ones such as 1) inelasticity of supply, 2) homogeneity of stevedoring services, 3) over-supply, 4) adoption of cutting-edge stevedoring technology, 5) scale economy and impossibility of storage, 6) labor market rigidity, 7) enhancing port's role in SCM. In addition, this study conducts the so-called structure-conduct-performance analysis. For the structure analysis, 1) lacks of scale economy in stevedoring companies, 2) high entry barrier, 3) strengthening of shipping firms' bargaining power, 4) transitory permission scheme for tariff are analyzed. For the conduct analysis, 1) price discrimination between export/import and transshipment, 2) mid-term length of terminal use contract, 3) continuous investment in equipment, 4) low level of cooperation among terminal operating firms are derived. For the performance analysis, 1) inequality in profitability, 2) reduction of export/import cost, 3) delay in adopting cutting-edge technology, 4) idle equipment are analyzed. Following this logical flow, the hypothesis that the market structure influences the market conduct is tested based on the actual dataset. As a future agenda in the conclusion, this article recommends the so-called port industrial policy.

Purification of Thiazole- and Pyrazine-inducible Microsomal Epoxide Hydrolase: Induction of Epoxide Hydrolase-related Novel 43 kDa Protein (Thiazole 또는 Pyrazine유도성 Microsomal Epoxide Hydrolase의 순수정제: Epoxide Hydrolase-관련성 43 kDa 단백질의 유도증가)

  • Kim, Sang-Geon
    • The Korean Journal of Pharmacology
    • /
    • v.29 no.2
    • /
    • pp.275-282
    • /
    • 1993
  • Liver microsomal epoxide hydrolase (mEH) is active in the detoxification of epoxide-containing reactive intermediate. Previous studies in this laboratory have shown that thiazole and pyrazine are efficacious inducers of mEH in rats with large increases in mEH mRNA levels (Carcinogensis, Kim et al, 1993). mEH was purified to electrophoretic homogeneity from thiazole-induced rat hepatic microsomes using DEAE-cellulose column chromatography whereas another protein $({\sim}43\;kDa)$ was co-purified with mEH from pyrazine-induced rat hepatic micrsomes (200 mg/kg body weight/day, ip, 3d). The antibody raised from a rabbit against mEH protein purified from thiazole-induced rat hepatic microsomes appeared to specifically recognize mEH protein in rat hepatic microsomes, as assessed by immunoblotting analysis. Immunoblotting analyses revealed a 10- and 7-fold increase in mEH levels in the hepatic microsomes isolated from thiazole- and pyrazine-treated rats, respectively. Moreover, immunoblotting analysis showed cross-reactivity of the mEH antibody with a 43 kDa protein in pyrazine-induced rat hepatic microsomes and with co-purified 43 kDa protein in purified fractions. The ratio between the 43 kDa protein and mEH in pyrazine-induced rat microsomes or in purified fractions was ${\sim}1$ to 15. N-terminal amino acid sequence analysis of both purified rat mEH and 43 kDa protein revealed that 10 out of 12 amino acids in N-terminus of the 43 kDa protein were identical with the mEH sequence with two amino acid residues of the 43 kDa protein undetermined. Either thiazole or pyrazine treatment, however, failed to increase the levels of mEH protein in rabbits while pyrazine caused elevation of the 43 kDa protein in this species, as determined by irnrnunoblotting analysis. These results demonstrated that treatment of rats with either thiazole or pyrazine causes elevation in hepatic mEH expiession whereas pyrazine treatment results in induction of another mEH-related 43 kDa protein and that a distinct species difference exists between rats and rabbits in the induction of mEH by these xenobiotics.

  • PDF

Microbial Influence on Soil Properties and Pollutant Reduction in a Horizontal Subsurface Flow Constructed Wetland Treating Urban Runoff (도시 강우유출수 처리 인공습지의 토양특성 및 오염물질 저감에 따른 미생물 영향 평가)

  • Chiny. C. Vispo;Miguel Enrico L. Robles;Yugyeong Oh;Haque Md Tashdedul;Lee Hyung Kim
    • Journal of Wetlands Research
    • /
    • v.26 no.2
    • /
    • pp.168-181
    • /
    • 2024
  • Constructed wetlands (CWs) deliver a range of ecosystem services, including the removal of contaminants, sequestration and storage of carbon, and enhancement of biodiversity. These services are facilitated through hydrological and ecological processes such as infiltration, adsorption, water retention, and evapotranspiration by plants and microorganisms. This study investigated the correlations between microbial populations, soil physicochemical properties, and treatment efficiency in a horizontal subsurface flow constructed wetland (HSSF CW) treating runoff from roads and parking lots. The methods employed included storm event monitoring, water quality analysis, soil sampling, soil quality parameter analysis, and microbial analysis. The facility achieved its highest pollutant removal efficiencies during the warm season (>15℃), with rates ranging from 33% to 74% for TSS, COD, TN, TP, and specific heavy metals including Fe, Zn, and Cd. Meanwhile, the highest removal efficiency was 35% for TOC during the cold season (≤15℃). These high removal rates can be attributed to sedimentation, adsorption, precipitation, plant uptake, and microbial transformations within the CW. Soil analysis revealed that the soil from HSSF CW had a soil organic carbon content 3.3 times higher than that of soil collected from a nearby landscape. Stoichiometric ratios of carbon (C), nitrogen (N), and phosphorus (P) in the inflow and outflow were recorded as C:N:P of 120:1.5:1 and 135.2:0.4:1, respectively, indicating an extremely low proportion of N and P compared to C, which may challenge microbial remediation efficiency. Additionally, microbial analyses indicated that the warm season was more conducive to microorganism growth, with higher abundance, richness, diversity, homogeneity, and evenness of the microbial community, as manifested in the biodiversity indices, compared to the cold season. Pollutants in stormwater runoff entering the HSSF CW fostered microbial growth, particularly for dominant phyla such as Proteobacteria, Actinobacteria, Acidobacteria, and Bacteroidetes, which have shown moderate to strong correlations with specific soil properties and changes in influent-effluent concentrations of water quality parameters.

Evaluating efficiency of Split VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes (골반 림프선을 포함한 전립선암 치료 시 Split VMAT plan의 유용성 평가)

  • Mun, Jun Ki;Son, Sang Jun;Kim, Dae Ho;Seo, Seok Jin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.145-156
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the efficiency of Split VMAT planning(Contouring rectum divided into an upper and a lower for reduce rectum dose) compare to Conventional VMAT planning(Contouring whole rectum) for prostate cancer radiotherapy involving pelvic lymph nodes. Materials and Methods : A total of 9 cases were enrolled. Each case received radiotherapy with Split VMAT planning to the prostate involving pelvic lymph nodes. Treatment was delivered using TrueBeam STX(Varian Medical Systems, USA) and planned on Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28), AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). Lower rectum contour was defined as starting 1cm superior and ending 1cm inferior to the prostate PTV, upper rectum is a part, except lower rectum from the whole rectum. Split VMAT plan parameters consisted of 10MV coplanar $360^{\circ}$ arcs. Each arc had $30^{\circ}$ and $30^{\circ}$ collimator angle, respectively. An SIB(Simultaneous Integrated Boost) treatment prescription was employed delivering 50.4Gy to pelvic lymph nodes and 63~70Gy to the prostate in 28 fractions. $D_{mean}$ of whole rectum on Split VMAT plan was applied for DVC(Dose Volume Constraint) of the whole rectum for Conventional VMAT plan. In addition, all parameters were set to be the same of existing treatment plans. To minimize the dose difference that shows up randomly on optimizing, all plans were optimized and calculated twice respectively using a 0.2cm grid. All plans were normalized to the prostate $PTV_{100%}$ = 90% or 95%. A comparison of $D_{mean}$ of whole rectum, upperr ectum, lower rectum, and bladder, $V_{50%}$ of upper rectum, total MU and H.I.(Homogeneity Index) and C.I.(Conformity Index) of the PTV was used for technique evaluation. All Split VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : Using DVH analysis, a difference between the Conventional and the Split VMAT plans was demonstrated. The Split VMAT plan demonstrated better in the $D_{mean}$ of whole rectum, Up to 134.4 cGy, at least 43.5 cGy, the average difference was 75.6 cGy and in the $D_{mean}$ of upper rectum, Up to 1113.5 cGy, at least 87.2 cGy, the average difference was 550.5 cGy and in the $D_{mean}$ of lower rectum, Up to 100.5 cGy, at least -34.6 cGy, the average difference was 34.3 cGy and in the $D_{mean}$ of bladder, Up to 271 cGy, at least -55.5 cGy, the average difference was 117.8 cGy and in $V_{50%}$ of upper rectum, Up to 63.4%, at least 3.2%, the average difference was 23.2%. There was no significant difference on H.I., and C.I. of the PTV among two plans. The Split VMAT plan is average 77 MU more than another. All IMRT verification gamma test results for the Split VMAT plan passed over 90.0% at 2 mm / 2%. Conclusion : As a result, the Split VMAT plan appeared to be more favorable in most cases than the Conventional VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes. By using the split VMAT planning technique it was possible to reduce the upper rectum dose, thus reducing whole rectal dose when compared to conventional VMAT planning. Also using the split VMAT planning technique increase the treatment efficiency.

  • PDF

The efficacy of continuous positive airway pressure (CPAP) for patient with left breast cancer (좌측 유방암 방사선치료에서 CPAP(Continuous Positive Airway Pressure)의 유용성 평가)

  • Jung, Il Hun;Ha, Jin Sook;Chang, Won Suk;Jeon, Mi Jin;Kim, Sei Joon;Jung, Jin Wook;Park, Byul Nim;Shin, Dong Bong;Lee, Ik Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose: This study examined changes in the position of the heat and lungs depending on the patient's breathing method during left breast cancer radiotherapy and used treatment plans to compare the resulting radiation dose. Materials and methods: The participants consisted of 10 patients with left breast cancer. A CT simulator(SIMENS SOMATOM AS, Germany) was used to obtain images when using three different breathing methods: free breathing(FB), deep inspiration breath hold(DIBH with Abches, DIBH), inspiration breath hold(IBH with CPAP, CPAP). A Ray Station(5.0.2.35, Sweden) was used for treatment planning, the treatment method was volumetric modulated arc therapy (VMAT) with one partial arc of the same angle, and the prescribed dose to the planning target volume (PTV) was a total dose of 50Gy(2Gy/day). In treatment plan analysis, the 95% dose (D95) to the PTV, the conformity index(CI), and the homogeneity index (HI) were compared. The lungs, heart, and left anterior descending artery (LAD) were selected as the organs at risk(OARs). Results: The mean volume of the ipsilateral lung for FB, DIBH, and CPAP was 1245.58±301.31㎤, 1790.09±362.43 ㎤, 1775.44±476.71 ㎤. The mean D95 for the PTV was 46.67±1.89Gy, 46.85±1.72Gy, 46.97±23.4Gy, and the mean CI and HI were 0.95±0.02, 0.96±0.02, 0.95±0.02 and 0.91±0.01, 0.90±0.01, 0.92±0.02. The V20 of Whole Lung was 10.74±4.50%, 8.29±3.14%, 9.12±3.29% and The V20 of the ipsilateral lung was 20.45±8.65%, 17.18±7.04%, 18.85±7.85%, the Dmean of the heart was 7.82±1.27Gy, 6.10±1.27Gy, 5.67±1.56Gy, and the Dmax of the LAD was 20.41±7.56Gy, 14.88±3.57Gy, 14.96±2.81Gy. The distance from the thoracic wall to the LAD was measured to be 11.33±4.70mm, 22.40±6.01mm, 20.14±6.23mm. Conclusion: During left breast cancer radiotherapy, the lung volume was 46.24% larger for DIBH than for FB, and 43.11% larger for CPAP than FB. The larger lung volume increases the distance between the thoracic wall and the heart. In this way, the LAD, which is one of the nearby OARs, can be more effectively protected while still satisfying the treatment plan. The lung volume was largest for DIBH, and the distance between the LAD and thoracic wall was also the greatest. However, when performing treatment with DIBH, the intra-fraction error cannot be ignored. Moreover, communication between the patient and the radiotherapist is also an important factor in DIBH treatment. When communication is problematic, or if the patient has difficulty holding their breath, we believe that CPAP could be used as an alternative to DIBH. In order to verify the clinical efficacy of CPAP, it will be necessary to perform long-term follow-up of a greater number of patients.