• Title/Summary/Keyword: Homogeneity Index

Search Result 173, Processing Time 0.02 seconds

Comparison of Dosimetric Parameters of Patient with Large and Pendulous Breast Receiving Breast Radiotherapy in the Prone versus Supine Position (유방 크기가 큰 유방암 환자의 방사선 치료 시 환자의 자세에 따른 선량 비교)

  • Moon, Sun Young;Yoon, Myonggeun;Chung, Weon Kuu;Chung, Mijoo;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.234-240
    • /
    • 2015
  • The purpose of this study is to analyze dosimetric parameters of patient with large and pendulous breast receiving breast radiotherapy in the prone versus supine position. The patient underwent computed tomography simulation in both prone and supine position. The homogeneity index (HI), conformity index (CI), coverage index (CVI) to the left breast as planning target volume (PTV) and the doses to the lung, heart, and right breast as organ at risk (OAR) were compared by using dose-volume histogram. The lifetime attributable risk (LAR) according to the prone and supine position was measured for the lung and right breast. The HI, CI of the PTV decreased 21.7%, 6.49%, respectively and the CVI increased 10.8% with the prone position. The mean and maximum dose to the left lung decreased 91.6%, 87.0%, respectively and the volume parameters also decreased over 99% with the prone position. The parameters to the right lung were same regardless of the position. The mean and maximum dose to the heart decreased 51.6%, 14.2% with the prone position. But the mean and maximum dose to the right breast increased unlike the other OARs. The LARs to the lung decreased 80.3% (left), 24.2% (right) but the LAR to the right breast doubled with the prone position. The prone position is a favorable alternative for irradiation of breast in patients with large and pendulous breasts.

Analysis of the major factors of influence on the conditions of the Intensity Modulated Radiation Therapy planning optimization in Head and Neck (두경부 세기견조방사선치료계획 최적화 조건에서 주요 인자들의 영향 분석)

  • Kim, Dae Sup;Lee, Woo Seok;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.11-19
    • /
    • 2014
  • Purpose : To derive the most appropriate factors by considering the effects of the major factors when applied to the optimization algorithm, thereby aiding the effective designing of a ideal treatment plan. Materials and Methods : The eclipse treatment planning system(Eclipse 10.0, Varian, USA) was used in this study. The PBC (Pencil Beam Convolution) algorithm was used for dose calculation, and the DVO (Dose Volume Optimizer 10.0.28) Optimization algorithm was used for intensity modulated radiation therapy. The experimental group consists of patients receiving intensity modulated radiation therapy for the head and neck cancer and dose prescription to two planned target volume was 2.2 Gy and 2.0 Gy simultaneously. Treatment plan was done with inverse dose calculation methods utilizing 6 MV beam and 7 fields. The optimal algorithm parameter of the established plan was selected based on volume dose-priority(Constrain), dose fluence smooth value and the impact of the treatment plan was analyzed according to the variation of each factors. Volume dose-priority determines the reference conditions and the optimization process was carried out under the condition using same ratio, but different absolute values. We evaluated the surrounding normal organs of treatment volume according to the changing conditions of the absolute values of the volume dose-priority. Dose fluence smooth value was applied by simply changing the reference conditions (absolute value) and by changing the related volume dose-priority. The treatment plan was evaluated using Conformal Index, Paddick's Conformal Index, Homogeneity Index and the average dose of each organs. Results : When the volume dose-priority values were directly proportioned by changing the absolute values, the CI values were found to be different. However PCI was $1.299{\pm}0.006$ and HI was $1.095{\pm}0.004$ while D5%/D95% was $1.090{\pm}1.011$. The impact on the prescribed dose were similar. The average dose of parotid gland decreased to 67.4, 50.3, 51.2, 47.1 Gy when the absolute values of the volume dose-priority increased by 40,60,70,90. When the dose smooth strength from each treatment plan was increased, PCI value increased to $1.338{\pm}0.006$. Conclusion : The optimization algorithm was more influenced by the ratio of each condition than the absolute value of volume dose-priority. If the same ratio was maintained, similar treatment plan was established even if the absolute values were different. Volume dose-priority of the treatment volume should be more than 50% of the normal organ volume dose-priority in order to achieve a successful treatment plan. Dose fluence smooth value should increase or decrease proportional to the volume dose-priority. Volume dose-priority is not enough to satisfy the conditions when the absolute value are applied solely.

Evaluation of Dose Volume and Radiobiological Indices by the Dose Calculation Grid Size in Nasopharyngeal Cancer VMAT (비 인두암 체적 조절 호형 방사선 치료의 선량 계산 격자 크기에 따른 선량 체적 지수와 방사선 생물학적 지수의 평가)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Shim, Jae-Goo;Park, So-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.265-272
    • /
    • 2020
  • The purpose of this study was to investigate the dose-volume indices and radiobiological indices according to the change in dose calculation grid size during the planning of nasopharyngeal cancer VMAT treatment. After performing the VMAT treatment plan using the 3.0 mm dose calculation grid size, dose calculation from 1.0 mm to 5.0 mm was performed repeatedly to obtain a dose volume histogram. The dose volume index and radiobiological index were evaluated using the obtained dose volume histogram. The smaller the dose calculation grid size, the smaller the mean dose for CTV and the larger the mean dose for PTV. For OAR of spinal cord, brain stem, lens and parotid gland, the mean dose did not show a significant difference according to the change in dose calculation grid size. The smaller the grid size, the higher the conformity of the dose distribution as the CI of the PTV increases. The CI and HI showed the best results at 3.0 mm. The smaller the dose calculation grid size, the higher the TCP of the PTV. The smaller the dose calculation grid size, the lower the NTCP of lens and parotid. As a result, when performing the nasopharynx cancer VMAT plan, it was found that the dose calculation grid size should be determined in consideration of dose volume index, radiobiological index, and dose calculation time. According to the results of various experiments, it was determined that it is desirable to apply a grid size of 2.0 - 3.0 mm.

Evaluation of Tangential Fields Technique Using TOMO Direct Radiation Therapy after Breast Partial Mastectomy (유방 부분 절제술 후 방사선 치료 시 TOMO Direct를 이용한 접선 조사의 선량적 유용성에 관한 고찰)

  • Kim, Mi-Jung;Kim, Joo-Ho;Kim, Hun-Kyum;Cho, Kang-Chul;Chun, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: Investigation of the clinical use of tangential fields technique using TOMO direct in comparison to conventional LINAC based radiation therapy after breast partial mastectomy. Materials and Methods: Treatment plans were created for 3 left-sided breast cancer patients who had radiation therapy after breast partial mastectomy by using wedged tangential fields technique, field in field technique (FIF), TOMO Direct, TOMO Direct intensity modulated radiation therapy (IMRT) under the normalized prescription condition ($D_{90%}$: 50.4 Gy/28 fx within CTV). Dose volume histogram (DVH) and isodose curve were used to evaluate the dose to the clinical target volume (CTV), organ at risk (OAR). We compared and analyzed dosimetric parameters of CTV and OAR. Dosimetric parameters of CTV are $D_{99}$, $D_{95}$, Dose homogeneity index (DHI: $D_{10}/D_{90}$) and $V_{105}$, $V_{110}$. And dosimetric parameters of OAR are $V_{10}$, $V_{20}$, $V_{30}$, $V_{40}$ of the heart and $V_{10}$, $V_{20}$, $V_{30}$ of left lung. Results: Dosimetric results of CTV, the average value of $D_{99}$, $D_{95}$ were $47.7{\pm}1.1Gy$, $49.4{\pm}0.1Gy$ from wedged tangential fields technique (W) and FIF (F) were $47.1{\pm}0.6Gy$, $49.2{\pm}0.4Gy$. And it was $49.2{\pm}0.4$ vs. $48.6{\pm}0.8Gy$, $49.9{\pm}0.4$ vs. $49.5{\pm}0.3Gy$ Gy for the TOMO Direct (D) and TOMO Direct IMRT (I). The average value of dose homogeneity index was W: $1.1{\pm}0.02$, F: $1.07{\pm}0.02$, D: $1.03{\pm}0.001$, I: $1.05{\pm}0.02$. When we compared the average value of $V_{105}$, $V_{110}$ using each technique, it was the highest as $34.6{\pm}9.3%$, $7.5{\pm}7.9%$ for wedged tangential fields technique and the value dropped for FIF as $16.5{\pm}14.8%$, $2.1{\pm}3.5%$, TOMO direct IMRT as $7.5{\pm}8.3%$, $0.1{\pm}0.1%$ and the TOMO direct showed the lowest values for both as 0%. Dosimetric results of OAR was no significant difference among each technique. Conclusion: TOMO direct provides improved target dose homogeneity over wedged tangential field technique. It is no increase the amount of normal tissue volumes receiving low doses, as oppose to IMRT or Helical TOMO IMRT. Also, it simply performs treatment plan procedure than FIF. TOMO Direct is a clinical useful technique for breast cancer patients after partial mastectomy.

  • PDF

Dosimetric comparison of volumetric modulated arc therapy with robotic stereotactic radiation therapy in hepatocellular carcinoma

  • Paik, Eun Kyung;Kim, Mi-Sook;Choi, Chul Won;Jang, Won Il;Lee, Sung Hyun;Choi, Sang Hyoun;Kim, Kum Bae;Lee, Dong Han
    • Radiation Oncology Journal
    • /
    • v.33 no.3
    • /
    • pp.233-241
    • /
    • 2015
  • Purpose: To compare volumetric modulated arc therapy of RapidArc with robotic stereotactic body radiation therapy (SBRT) of CyberKnife in the planning and delivery of SBRT for hepatocellular carcinoma (HCC) treatment by analyzing dosimetric parameters. Materials and Methods: Two radiation treatment plans were generated for 29 HCC patients, one using Eclipse for the RapidArc plan and the other using Multiplan for the CyberKnife plan. The prescription dose was 60 Gy in 3 fractions. The dosimetric parameters of planning target volume (PTV) coverage and normal tissue sparing in the RapidArc and the CyberKnife plans were analyzed. Results: The conformity index was $1.05{\pm}0.02$ for the CyberKnife plan, and $1.13{\pm}0.10$ for the RapidArc plan. The homogeneity index was $1.23{\pm}0.01$ for the CyberKnife plan, and $1.10{\pm}0.03$ for the RapidArc plan. For the normal liver, there were significant differences between the two plans in the low-dose regions of $V_1$ and $V_3$. The normalized volumes of $V_{60}$ for the normal liver in the RapidArc plan were drastically increased when the mean dose of the PTVs in RapidArc plan is equivalent to the mean dose of the PTVs in the CyberKnife plan. Conclusion: CyberKnife plans show greater dose conformity, especially in small-sized tumors, while RapidArc plans show good dosimetric distribution of low dose sparing in the normal liver and body.

Influence of different boost techniques on radiation dose to the left anterior descending coronary artery

  • Park, Kawngwoo;Lee, Yongha;Cha, Jihye;You, Sei Hwan;Kim, Sunghyun;Lee, Jong Young
    • Radiation Oncology Journal
    • /
    • v.33 no.3
    • /
    • pp.242-249
    • /
    • 2015
  • Purpose: The purpose of this study is to compare the dosimetry of electron beam (EB) plans and three-dimensional helical tomotherapy (3DHT) plans for the patients with left-sided breast cancer, who underwent breast conserving surgery. Materials and Methods: We selected total of 15 patients based on the location of tumor, as following subsite: subareolar, upper outer, upper inner, lower lateral, and lower medial quadrants. The clinical target volume (CTV) was defined as the area of architectural distortion surrounded by surgical clip plus 1 cm margin. The conformity index (CI), homogeneity index (HI), quality of coverage (QC) and dose-volume parameters for the CTV, and organ at risk (OAR) were calculated. The following treatment techniques were assessed: single conformal EB plans; 3DHT plans with directional block of left anterior descending artery (LAD); and 3DHT plans with complete block of LAD. Results: 3DHT plans, regardless of type of LAD block, showed significantly better CI, HI, and QC for the CTVs, compared with the EB plans. However, 3DHT plans showed increase in the $V_{1Gy}$ at skin, left lung, and left breast. In terms of LAD, 3DHT plans with complete block of LAD showed extremely low dose, while dose increase in other OARs were observed, when compared with other plans. EB plans showed the worst conformity at upper outer quadrants of tumor bed site. Conclusion: 3DHT plans offer more favorable dose distributions to LAD, as well as improved target coverage in comparison with EB plans.

Comparison of the Oral Health Education Effect of Air Force Personnel according to the Use of Disclosing Solution (치면 착색제 사용 유무에 따른 공군장병의 구강 보건 교육 효과 비교)

  • Lee, Hye-Rim;Jung, Gyu-Un;Pang, Eun-Kyoung
    • The Journal of the Korean dental association
    • /
    • v.54 no.1
    • /
    • pp.57-66
    • /
    • 2016
  • This study was to evaluate the effects of oral health education conducted on air force personnel according to the use of disclosing solution. They were divided into 3 groups: Group A: oral health education was not conducted, Group B: oral health education was conducted without using disclosing solution, and Group C: oral health education was conducted using disclosing solution. The subjects who had not participated in the education at least once were excluded, and the remaining 83 subjects received oral health education four times and one time each week. The probing depth, plaque index, gingival index, and bleeding on probing were measured one week before the implementation of the first oral health education and one week after the implementation of the fourth oral health education. The results of verifying the homogeneity of the clinical indices before the oral health education showed statistically significant differences in bleeding on probing among the three groups. The results of comparing the clinical indices among the three groups after the oral health education exhibited statistically significant differences in the plaque and gingival indices among the three groups. Groups B and C showed lower values than Group A. The comparison of the clinical indices before and after the oral health education showed statistically significant improvements in all clinical indices after the education in Group C. The results suggested that the oral health education using disclosing solution could maximize that visual effects and encourage self-motivation, consequently improve the oral hygiene of the patients.

  • PDF

Comparisons of Quality of Life, Sexual Function, and Depression in Sexually Active or Inactive Groups of Women with Mastectomy (유방암 생존자의 삶의 질, 성기능 및 우울: 성생활 집단과 비성생활 집단 간의 비교)

  • Kim, Hae-Young;So, Hyang-Sook;Chae, Myeong-Jeong;Kim, Kyoung-Mi
    • Asian Oncology Nursing
    • /
    • v.8 no.2
    • /
    • pp.77-85
    • /
    • 2008
  • Purpose: This study was to compare quality of life, sexual function, and depression between a group with sexually active women and the other with sexually inactive women who undertaken mastectomy. Methods: Participants were 106 breast cancer patients who had spouse and participated in self-help group in Gwangju, Korea. The questionnaires were consisted of Quality of Life Index-Cancer Version (Q.L.I.-C), self-rating depression scale, and Female Sexual Function Index (FSFI). Data were analyzed using the SPSS Win 14.0 K+ for descriptive statistics, t-test, ANCOVA, and MANOVA. Results: There were no homogeneity at age, job, educational years between sexually active vs. inactive groups. In sexually active group, mean age was 46.1, having job 34.5%, bachelor's degree 38.2%, and pre-menopause 79.2%; for the inactive group 49.6, 10.4%, 12.5%, and 52.7% seperately. There were significant differences in quality of life, sexual function, and depression between two groups when four covariates were controlled. The quality of life and sexual function in sexually active group were significantly higher than inactive group(p<0.001). The depression in sexually active group was significantly lower than inactive group(p<0.001). Conclusion: This study indicates that nurses are needed to counsel and intervene psychosexual approach especially sexually inactive women with breast cancer during the recovery period.

  • PDF

Radiotherapy for gastric mucosa-associated lymphoid tissue lymphoma: dosimetric comparison and risk assessment of solid secondary cancer

  • Bae, Sun Hyun;Kim, Dong Wook;Kim, Mi-Sook;Shin, Myung-Hee;Park, Hee Chul;Lim, Do Hoon
    • Radiation Oncology Journal
    • /
    • v.35 no.1
    • /
    • pp.78-89
    • /
    • 2017
  • Purpose: To determine the optimal radiotherapy technique for gastric mucosa-associated lymphoid tissue lymphoma (MALToma), we compared the dosimetric parameters and the risk of solid secondary cancer from scattered doses among anterior-posterior/ posterior-anterior parallel-opposed fields (AP/PA), anterior, posterior, right, and left lateral fields (4_field), 3-dimensional conformal radiotherapy (3D-CRT) using noncoplanar beams, and intensity-modulated radiotherapy composed of 7 coplanar beams (IMRT_co) and 7 coplanar and noncoplanar beams (IMRT_non). Materials and Methods: We retrospectively generated 5 planning techniques for 5 patients with gastric MALToma. Homogeneity index (HI), conformity index (CI), and mean doses of the kidney and liver were calculated from the dose-volume histograms. Applied the Biological Effects of Ionizing Radiation VII report to scattered doses, the lifetime attributable risk (LAR) was calculated to estimate the risk of solid secondary cancer. Results: The best value of CI was obtained with IMRT, although the HI varied among patients. The mean kidney dose was the highest with AP/PA, followed by 4_field, 3D-CRT, IMRT_co, and IMRT_non. On the other hand, the mean liver dose was the highest with 4_field and the lowest with AP/PA. Compared with 4_field, the LAR for 3D-CRT decreased except the lungs, and the LAR for IMRT_co and IMRT_non increased except the lungs. However, the absolute differences were much lower than <1%. Conclusion: Tailored RT techniques seem to be beneficial because it could achieve adjacent organ sparing with very small and clinically irrelevant increase of secondary solid cancer risk compared to the conventional techniques.

Influence of jaw tracking in intensity-modulated and volumetric-modulated arc radiotherapy for head and neck cancers: a dosimetric study

  • Mani, Karthick Raj;Upadhayay, Sagar;Das, K.J. Maria
    • Radiation Oncology Journal
    • /
    • v.35 no.1
    • /
    • pp.90-100
    • /
    • 2017
  • Purpose: To Study the dosimetric advantage of the Jaw tracking technique in intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for Head and Neck Cancers. Materials and Methods: We retrospectively selected 10 previously treated head and neck cancer patients stage (T1/T2, N1, M0) in this study. All the patients were planned for IMRT and VMAT with simultaneous integrated boost technique. IMRT and VMAT plans were performed with jaw tracking (JT) and with static jaw (SJ) technique by keeping the same constraints and priorities for a particular patient. Target conformity, dose to the critical structures and low dose volumes were recorded and analyzed for IMRT and VMAT plans with and without JT for all the patients. Results: The conformity index average of all patients followed by standard deviation (${\bar{x}}{\pm}{\sigma}_{\bar{x}}$) of the JT-IMRT, SJ-IMRT, JT-VMAT, and SJ-VMAT were $1.72{\pm}0.56$, $1.67{\pm}0.57$, $1.83{\pm}0.65$, and $1.85{\pm}0.64$, and homogeneity index were $0.059{\pm}0.05$, $0.064{\pm}0.05$, $0.064{\pm}0.04$, and $0.064{\pm}0.05$. JT-IMRT shows significant mean reduction in right parotid and left parotid shows of 7.64% (p < 0.001) and 7.45% (p < 0.001) compare to SJ-IMRT. JT-IMRT plans also shows considerable dose reduction to thyroid, inferior constrictors, spinal cord and brainstem compared to the SJ-IMRT plans. Conclusion: Significant dose reductions were observed for critical structure in the JT-IMRT compared to SJ-IMRT technique. In JT-VMAT plans dose reduction to the critical structure were not significant compared to the SJ-IMRT due to relatively lesser monitor units.