• Title/Summary/Keyword: Home Indoor Air Quality

Search Result 35, Processing Time 0.021 seconds

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Evaluation of Ventilation Deficiecy in Elementary, Middle, and High Schools using Monte Carlo Simulation (Monte-Carlo 모의실험을 이용한 초·중·고등학교의 환기부족 평가)

  • Choe, Youngtae;Park, Jinhyeon;Kim, Eunchae;Ryu, Hyoensu;Kim, Dong Jun;Min, Kihong;Jung, Dayoung;Woo, Byung Lyul;Cho, Mansu;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.627-635
    • /
    • 2020
  • Objectives: Indoor air quality has become more important aspeople spend most of their times indoors. Since students spend most of their times at home or at school, they are more likely to be exposed to indoor air pollutants. Ventilation in school classrooms can affect health and learning performance. In this study, ventilation deficiency was evaluated in school classrooms using Monte Carlo simulation. Methods: This study used sensor-based monitoring for six months to measure carbon dioxide (CO2) concentrations in classrooms in elementary, middle, and high schools. The volume of the classroom and the number of students were investigated, and the students' body surface area was used to calculate the CO2 emission rate. The distribution of ventilation rates was estimated by measured CO2 concentration and a mass-balance model using Monte Carlo simulation. Results: In the elementary, middle, and high schools, the average CO2 concentrations exceeded 1000 ppm, indicating that the ventilation rates were insufficient. The ventilation rates were deficient from July to August and in December, but showed relatively high ventilation rates in October. Forty-three percent of elementary schools, 56% of middle schools, and 62% of high schools showed insufficient ventilation rates. Conclusions: The ventilation rates calculated in elementary, middle and high schools were found to be quite insufficient. Therefore, proper management is needed to overcome the lack of ventilation and improve air quality.

A Study of Case Analysis on Green Building Certification Criteria for Advanced Methods (사례분석을 통한 친환경 건축물 인증제도 개선방향 연구)

  • Mo, Ji-Sun;Kim, Chul;Lim, Tae-Sub;Kang, Youn-Do;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.178-183
    • /
    • 2008
  • Recently, sick house syndrome caused by pollutants and contamination of buildings crops out in residential environment of buildings. According to price increase of global oil, comfort of occupants in indoor air quality is required with reduction of energy consumption and environmental load. So, building performance certification criteria come into effect for improvement of building energy efficiency and performance in environment at home and abroad. GBCC(Green Building Certification Criteria) of domestic country as a Criteria is managed Korea Green Building Council(KGBC) for green building. Thus, purpose of this study is to design a direction of Green Building Certification Criteria for improvement through analysis of GBCC application elements and selected building.

  • PDF

Measurement of Residential Volatile Organic Compound Exposure Through A Participant-Based Method (연구참여자에 의한 주택실내 휘발성 유기화합물 농도의 측정)

  • Hwang, Yun-Hyung;Lee, Ki-Young;Kim, Seo-Jin;Hong, Yun-Chul;Jun, Jong-Kwan;Cho, Soo-Hun
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.5
    • /
    • pp.369-375
    • /
    • 2011
  • Objectives: Exposure to hazardous chemicals during pregnancy may result incritical reproductive health outcomes. Indoor residential levels are significant component of personal exposure. The collection of residential exposure data has been hampered by the cost and participant burden of health studies of indoor air pollution. This study utilized a participant-based approach to collect volatile organic compounds concentration from homes. Methods: Four hundred thirteen women were recruited from three major hospitals in Seoul and Gyeongi Provence and 411 agreed to participate. A passive sampler (OVM 3500, 3M, USA) with instructions were given to the participants, as well as a questionnaire. They were asked to deploy the sampler in their homes for three to five days and return them viapre-stamped envelope. Results: Three hundred forty six participants returned the sampler. Among the returned samplers, three hundred samplers satisfied our monitoring quality criteria. The success rate of the monitoring method was 73%. The geometric mean of TVOC level was 429(2) ${\mu}g/m^3$. The TVOC guideline of 500 ${\mu}g/m^3$ was exceeded in 38% of the houses. The residential VOC levels were significantly associated with remodeling of the house. Conclusions: The results suggested that a participant-based sampling approach may be a feasible and costeffective alternative to exposure assessment involving home visits by a field technician.

An Experimental Study on Performance of Energy Recovery Ventilation System (폐열회수 환기시스템의 성능에 관한 실험적 연구)

  • Kim, Young-Soo;Choi, Kwan-Soo;Kim, Il-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.445-450
    • /
    • 2012
  • At the limited space, the air conditioning may have difficult to control temperature or humidity for home use. Nowdays, the people reponse to temperature or humidity sensitively. This becomes the Indoor Air Quality (IAQ) is an important factor for comfortably. Heat recovery ventilator (HRV) is used for the solution of inconsistency between IAQ and power-saving. Also, the thermoelectric element is applied to HRV and compared with temperature efficiency and verifying the capacity of the system. To improve the temperature efficiency a single motor and thermoelectric element with the conductive guide vane is experimented. The results shows that it can save 23 W by using the single motor. The developed system of 250 CMH capacities with the thermoelectric element reveals the temperature efficiency improvement of 4.01% in cooling period and 2.98% in heating period compared to the conventional system.