• Title/Summary/Keyword: Hollow Fiber

Search Result 631, Processing Time 0.024 seconds

Extraction/Separations of Cobalt by Supported Liquid Membrane: A Review

  • Swain, Basudev;Shim, Hyun-Woo;Lee, Chan Gi
    • Korean Chemical Engineering Research
    • /
    • v.57 no.3
    • /
    • pp.313-320
    • /
    • 2019
  • Extraction/separation of cobalt by supported liquid membrane has been reviewed. The review discusses various directions associated with the supported liquid membrane process, such as the kind of supported liquid membrane, the principle of supported liquid membrane, transport mechanism involved, and the advantages and disadvantages of the supported liquid. Finally, extraction and separation of cobalt from other metals using extractant through supported liquid membrane have been reviewed. Separation of cobalt using various reagents and cobalt recovery from scrap using commercial extractant can be a potential perspective from the application of supported liquid membrane application.

동시획득 $T_{1}T_{2}^{*}$ 강조 경사 자장 펄스열을 사용한 관류량과 투과도 측정

  • 김은주;김대홍;이희조;허용민;이상훈;이삼현;서진석
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.103-103
    • /
    • 2002
  • 목적:자화율 대조법을 사용한 관류 영상에서 동시획득 $T_{1}T_{2}^{*}$ 강조 경사 자장 펄스열을 사용하여 Gd-DTPA에 의한 $T_{1}T_{2}^{*}$ 감소 효과를 동시에 획득하여 종양의 치료 효과, 판정에 중요한 기준을 제시할 수 있는 정확한 관류 정보를 얻고자 한다. 대상 및 방법: Gd-DTPA에 의한 $T_{1}T_{2}^{*}$ 감소 효과를 동시에 획득하기 위하여 기존의 이중 경사자장 펄스열을 수정, 동시획득 $T_{1}T_{2}^{*}$ 강조 경사자장 펄스열을 개발하였고, 시간 해상도를 높이기 위하여 key-hole 방법을 사용하였다. 고정 phantom으로 Sephadex를 다양한 농도의 Gd-DTPA 용액에 swelling하여 사용하였고, 관류 phantom으로는 Sephadex와 Dialyzer를 사용하였다. Sephadex는 swelling 하였을 때 $T_1$, $T_2$값이 생체 조직의 값과 비슷하고, 물을 관류시킬 수 있어 생체 모형에 적합한 phantom이다 .관류 phantom은 정량 펌프에 연결하여 사용하였다. Sephadex 관류 phantom에서는 분당 약 4$m\ell$ 속도로 관류시키면서 25 mM Gd-DTPA을 0.1$m\ell$ 일시 주입하여 관류 방향에 수직인 coronal 영상을 약 15분 동안 얻었다. 투과도를 구하기 위한 phantom으로는 hollow fiber type Dialyzer를 사용하였고, in vivo에서 1차 관류 이후에 현관 밖에서의 Gd농도가 높고 혈관 내부의 농도가 낮은 상태를 만들기 위하여 fiber 바깥쪽으로 500 mM Gd-DTPA 2 ml를 미리 넣어두고 fiber 내부로 이보다 낮은 농도의 Gd 용액을 관류시키면서 약 1시간동안 영상을 얻었다. 관류 영상에서 $T_1$/$T_{2}^{*}$ 감소 효과를 구분하여 구한 $\DeltaR_1$, $\DeltaR_2$ 곡선의 적분값으로부터 관류량을 구하고, 2 구획 모델을 적용하여 투과도를 구했다.

  • PDF

동시획득 $T_{1}{/}T_{2}^{*}$강조 경사 자장 펄스열을 사용한 관류량과 투과도 측정

  • 김은주;김대홍;이희조;허용민;이상훈;이삼현;서진석
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.127-127
    • /
    • 2002
  • 목적: 자화율 대조법을 사용한 관류 영상에서 동시획득 $T_{1}{/}T_{2}^{*}$ 강조 경사 자장 펄스열을 사용하여 Gd-DTPA에 의한 $T_{1}{/}T_{2}^{*}$ 감소 효과를 동시에 획득하여 종양의 치료 효과, 판정에 중요한 기준을 제시할 수 있는 정확한 관류 정보를 얻고자 한다. 대상 및 방법: Gd-DTPA에 의한 $T_{1}{/}T_{2}^{*}$ 감소 효과를 동시에 획득하기 위하여 기존의 이중 경사자장 펄스열을 수정, 동시획득 $T_{1}{/}T_{2}^{*}$ 강조 경사자장 펄스열을 개발하였고, 시간 해상도를 높이기 위하여 key-hole 방법을 사용하였다. 고정 phantom으로 Sephadex를 다양한 농도의 Gd-DTPA 용액에 swelling하여 사용하였고, 관류 phantom으로는 Sephadex와 Dialyzer를 사용하였다. Sephadex는 swelling 하였을 때 $T_1$, $T_2$값이 생체 조직의 값과 비슷하고, 물을 관류시킬 수 있어 생체 모형에 적합한 phantom이다. 관류 phantom은 정량 펌프에 연결하여 사용하였다. Sephadex 관류 phantom에서는 분당 약 4$m\ell$ 속도로 관류시키면서 25 mM Gd-DTPA을 0.1$m\ell$ 일시 주입하여 관류 방향에 수직인 coronal 영상을 약 15분 동안 얻었다. 투과도를 구하기 위한 phantom으로는 hollow fiber type Dialyzer를 사용하였고, in vivo에서 1차 관류 이후에 혈관 밖에서의 Gd 농도가 높고 혈관 내부의 농도가 낮은 상태를 만들기 위하여 fiber 바깥쪽으로 500mM Gd-DTPA 2$m\ell$를 미리 넣어두고 fiber 내부로 이보다 낮은 농도의 Gd 용액을 관류시키면서 약 1시간동안 영상을 얻었다. 관류 영상에서 $T_{1}{/}T_{2}^{*}$ 감소 효과를 구분하여 구한 $\Delta{R}_{1}$, $\Delta{R}_{2}^{*}$ 곡선의 적분값으로부터 관류량을 구하고, 2 구획 모델을 적용하여 투과도를 구했다.

  • PDF

Fabrication of Various Carbides with Fibrous and Particulate Shapes by Self-Propagating High Temperature Synthesis Method (자전연소합성법에 의한 여러 가지 섬유상 및 입상 탄화물의 제조)

  • Bang, Hwan-Cheol;Yun, Jon-Do
    • Korean Journal of Materials Research
    • /
    • v.10 no.5
    • /
    • pp.343-349
    • /
    • 2000
  • Fabrication of various carbide fibers from carbon fibers and elementary powders of Ti, Zr, Nb, Zi, W, B, and Mo by self-propagating high temperature synthesis was attempted. It was found the almost pure phase of TiC, ZrC, NbC, SiC, $B_4$C, and $Mo_2$C carbides were successfully produced. The three types of morphologies were ob-served, TiC, ZrC, NbC, and $B_4$C had a hollow-type fibrous shape. SiC had fiber shape consisting of smaller particles and fine whiskers. WC and $Mo_2$C had non-fibrous shapes. The reason for the different morphologies was explained. The formation mechanism of hollow fibers was suggested.

  • PDF

Microstructural changes of polyacrylonitrile-based carbon fibers (T300 and T700) due to isothermal oxidation (1): focusing on morphological changes using scanning electron microscopy

  • Oh, Seong-Moon;Lee, Sang-Min;Kang, Dong-Su;Roh, Jae-Seung
    • Carbon letters
    • /
    • v.18
    • /
    • pp.18-23
    • /
    • 2016
  • Polyacrylonitrile (PAN)-based carbon fibers have high specific strength, elastic modulus, thermal resistance, and thermal conductivity. Due to these properties, they have been increasingly widely used in various spheres including leisure, aviation, aerospace, military, and energy applications. However, if exposed to air at high temperatures, they are oxidized, thus weakening the properties of carbon fibers and carbon composite materials. As such, it is important to understand the oxidation reactions of carbon fibers, which are often used as a reinforcement for composite materials. PAN-based carbon fibers T300 and T700 were isothermally oxidized in air, and microstructural changes caused by oxidation reactions were examined. The results showed a decrease in the rate of oxidation with increasing burn-off for both T300 and T700 fibers. The rate of oxidation of T300 fibers was two times faster than that of T700 fibers. The diameter of T700 fibers decreased linearly with increasing burn-off. The diameter of T300 also decreased with increasing burn-off but at slower rates over time. Cross-sectional observations after oxidation reactions revealed hollow cores in the longitudinal direction for both T300 and T700 fibers. The formation of hollow cores after oxidation can be traced to differences in the fabrication process such as the starting material and final heat treatment temperature.

Experimental and numerical investigation of strengthened deficient steel SHS columns under axial compressive loads

  • Shahraki, Mehdi;Sohrabi, Mohammad Reza;Azizyan, Gholam Reza;Narmashiri, Kambiz
    • Structural Engineering and Mechanics
    • /
    • v.67 no.2
    • /
    • pp.207-217
    • /
    • 2018
  • In past years, numerous problems have vexed engineers with regard to buckling, corrosion, bending, and overloading in damaged steel structures. This article sets out to investigate the possible effects of carbon fiber reinforced polymer (CFRP) and steel plates for retrofitting deficient steel square hollow section (SHS) columns. The effects of axial loading, stiffness, axial displacement, the position and shape of deficient region on the length of steel SHS columns, and slenderness ratio are examined through a detailed parametric study. A total of 14 specimens was tested for failure under axial compression in a laboratory and simulated using finite element (FE) analysis based on a numerical approach. The results indicate that the application of CFRP sheets and steel plates also caused a reduction in stress in the damaged region and prevented or retarded local deformation around the deficiency. The findings showed that a deficiency leads to reduced load-carrying capacity of steel SHS columns and the retrofitting method is responsible for the increase in the load-bearing capacity of the steel columns. Finally, this research showed that the CFRP performed better than steel plates in compensating the axial force caused by the cross-section reduction due to the problems associated with the use of steel plates, such as in welding, increased weight, thermal stress around the welding location, and the possibility of creating another deficiency by welding.

Post-fire test of precast steel reinforced concrete stub columns under eccentric compression

  • Yang, Yong;Xue, Yicong;Yu, Yunlong;Gong, Zhichao
    • Steel and Composite Structures
    • /
    • v.33 no.1
    • /
    • pp.111-122
    • /
    • 2019
  • This paper presents an experimental work on the post-fire behavior of two kinds of innovative composite stub columns under eccentric compression. The partially precast steel reinforced concrete (PPSRC) column is composed of a precast outer-part cast using steel fiber reinforced reactive powder concrete (RPC) and a cast-in-place inner-part cast using conventional concrete. Based on the PPSRC column, the hollow precast steel reinforced concrete (HPSRC) column has a hollow column core. With the aim to investigate the post-fire performance of these composite columns, six stub column specimens, including three HPSRC stub columns and three PPSRC stub columns, were exposed to the ISO834 standard fire. Then, the cooling specimens and a control specimen unexposed to fire were eccentrically loaded to explore the residual capacity. The test parameters include the section shape, concrete strength of inner-part, eccentricity ratio and heating time. The test results indicated that the precast RPC shell could effectively confine the steel shape and longitudinal reinforcements after fire, and the PPSRC stub columns experienced lower core temperature in fire and exhibited higher post-fire residual strength as compared with the HPSRC stub columns due to the insulating effect of core concrete. The residual capacity increased with the increasing of inner concrete strength and with the decreasing of heating time and load eccentricity. Based on the test results, a FEA model was established to simulate the temperature field of test specimens, and the predicted results agreed well with the test results.

Enzymatic Hydrolysis of Yellowfin Sole Skin Gelatin in a Continuous Hollow Fiber Membrane Reactor (연속식 중공사막 반응기를 이용한 각시가자미피 젤라틴의 가수분해)

  • KIM Se-Kwon;BYUN Hee-Guk;KANG Tae-Jung;SONG Dae-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.26 no.2
    • /
    • pp.120-132
    • /
    • 1993
  • A continuous hollow fiber membrane reactor(CHFMR) was developed and optimized for the production of yellowfin sole(Limanda aspera) skin gelatin hydrolysates using trypsin. The results were summerized as follows: The $K_m$ value of the CHFMR was 2.4 times higher than that of the batch reactor, indicating reduced enzyme affinity for the substrate. The $K_2$ value of the CHFMR was 8.5 times lower than that of the batch process, showing a significant reduction in trypsin activity in the CHFMR. The optimum operating conditions for the CHFMR process were $55^{\circ}C$, pH 9.0, flux 7.79 ml/min, residence time 77min, and trypsin to substrate ratio, 0.01(w/w) After operating for 60min under the above conditions, $79\%$ of the total amount of initial gelatin was hydrolysed. Enzyme leakage was observed through the 10,000 MWCO membrane after the 20min of reactor operation, while none occurred after 5hr. Total enzyme leakage was about $12.95\%$ at $55^{\circ}C$ for 5hrs. However, there was no apparent correlation between enzyme leakage and substrate hydrolysis. The membrane has a significant effect on trypsin activity loss for 60min of the CHFMR operation. The CHFMR operating with the membrane lost $34\%$ of the initial activity versus a $23\%$ loss of activity after 3hr in the continuous reactor lacking the hollow fiber membrane. The measurement of fouling property showed that relative flux reduction was $91\%$ and flux recover rate was $92\%$ at $10\%$ substrate solution. The productivity(378.85mg product/mg enzyme) of the CHFMR was more than 4 times higher than that of the batch reactor at $55^{\circ}C$.

  • PDF

Preparation of Composite Membranes Via PVA/PAM Solution Coating onto Hydrophilized PVDF Hollow Fiber Membrane and Their Pervaporation Separation of Water-ethanol Mixture (PVDF 중공사막의 표면친수화 후 PVA/PAM 용액의 코팅을 통한 복합막제조와 이의 물-에탄올계의 투과증발 분리)

  • Kim, Ji Seon;Park, Chae Young;Park, Hun Whee;Seo, Chang Hee;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.23 no.4
    • /
    • pp.312-318
    • /
    • 2013
  • Poly vinylidene fluoride (PVDF) hollow fiber membranes were hydrophilized using polyethylenimine (PEI) and p-xylylene dichloride (XDC), and poly(vinyl alcohol) (PVA) and poly (acrylic acid -co- maleic acid) (PAM) mixed solutions by varying the concentration of PAM were coated onto PVDF membrane surface. The surface coating was verified by the observation of scanning electron microscope (SEM) and the permselective characteristcs of the resulting composite membranes were tested for 90 wt% aqueous ethanol solution by the pervaporation technique. The effects of the corsslinking agent concentraion, the temperature of feed solution, and the reaction temperature on the flux and separation factors were measured. Typically, the flux, $1,480g/m^2hr$ at the reaction temperature $100^{\circ}C$, PAM 3 wt%, feed temperature $70^{\circ}C$ was obtained, on the other hand, for the separation factor, ${\alpha}_{W/E}=82$ at the conditions of the reaction temperature $100^{\circ}C$, PAM 15 wt% and feed temperature $25^{\circ}C$ was shown.

Characterization of Ceramic Membranes by Gas-Liquid Displacement Porometer and Liquid-Liquid Displacement Porometer (Gas-Liquid Displacement Porometer와 Liquid-Liquid Displacement Porometer를 이용한 세라믹 분리막 특성 분석)

  • Kim, Yeo-Jin;Kim, Seong-Joong;Kim, Jeong;Jo, Yeong-Hoon;Park, Hosik;Lee, Pyung-Soo;Park, You-In;Park, Ho-Bum;Nam, Seung-Eun
    • Membrane Journal
    • /
    • v.27 no.3
    • /
    • pp.263-272
    • /
    • 2017
  • There are several different methods to characterize membrane pore size distribution, however, it is yet difficult to accurately measure pore size range of 10-50 nm. In this work, we employed gas-liquid displacement porometer (GLDP) and liquid-liquid displacement porometer (LLDP) to characterize in-house alumina hollow fiber membrane (K-100) and commercial membranes (A-100, A-20) that exhibit pore sizes between 10-100 nm. GLDP method was more suitable for measuring the maximum pore size, and the measured mean pore size of the membranes by LLDP were better correlated with water permeability and solute rejection. It was determined that LLDP is effective for measuring pore sizes between 10-50 nm; however, the method holds intrinsic disadvantages such as low precision and high sensitivity compared to that of GLDP. Nevertheless, it is expected that the recently commercialized LLDP technique can provide useful data that other methods cannot.