• Title/Summary/Keyword: Hollow

Search Result 2,260, Processing Time 0.025 seconds

Development of Hollow-fiber Reactor System for the Production of Chiral 1,2-epoxy-7-octene by Microbial Enantioselective Hydrolysis Reaction (미생물 입체선택성 가수분해반응을 이용한 광학활성 1,2-epoxy-7-octene 생산을 위한 Hollow-fiber 반응기 시스템 개발)

  • 이은열;김희숙
    • KSBB Journal
    • /
    • v.16 no.3
    • /
    • pp.259-263
    • /
    • 2001
  • The development of hollow fiber reactor system for the production of chiral 1,2-epoxy-7-octence by epoxide hydrolase for Rhodotorula glutinis was investigated. Dodecane with high solubility of the racemic substrate passed through the lumen side of the hollow fiber reactor and cell suspension was recirculated through the shell side. The 2nd hollow fiber reactor was coupled to the production reactor to extract the diol byproduct which was the inhibitor of epoxide hydrolase. Optically pure (S)-1,2-epoxy-7-octene (0.6 M in dodecane) could be obtained using hollow-fiber reactor system.

  • PDF

A Study on Die Forging of a Hollow T-shaped Part (중공 T형상의 형단조에 관한 연구)

  • 김현수;김용조
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.1
    • /
    • pp.32-39
    • /
    • 2004
  • Traditional forging of a hollow T-shaped part has been applied to forge a solid T-shaped product from a solid billet and then to machine the hollow in that. In a case, a hollow T-shaped part can be forged by backward-extruding from a solid billet. In this study, four types of forging were suggested for manufacture of hollow T-shaped parts. Forging simulations for each of these forging methods were carried out to investigate folding defect, metal flow pattern, effective strain, and forging loads. Experimental works were carried out to be compared with the simulation results. Here, the ratio of the thickness of the hollow tube to that of the flange was selected to investigate a forging defect like folding.

Comparative Activity of Medicinal Herbs Between Hollow Fiber Assay and Xenographic Animal Assay (Hollow Fiber 검색법과 Xenographic Animal Assay를 이용한 생약재의 암세포 저해활성 비교)

  • Cho, Choa-Hyung;Yoon, Won-Ho;Lee, Keyong-Ho
    • Korean Journal of Pharmacognosy
    • /
    • v.34 no.4 s.135
    • /
    • pp.288-292
    • /
    • 2003
  • We compared the antitumor activity between hollow fiber assay and xenographic animal assay on thirty herbal plants. It is evaluated that the antitumor activity of above 30% is regarded as 'positive response', and its of below 30% is regarded as 'negative response'. The two herbal plants extracts (Ulmus davidiana Hedyotis diffusa) among thirty herbal plants show to be positive in xenographic animal assay and they were also correctly identified as positive by the hollow fiber assay. The correlation of the hollow fiber assay data with xenographic animal assay would suggest that hollow fiber assay presents a potentially unique tool to develop the herbal medicine for cancer.

Effect of moisture on the compressive strength of low-strength hollow concrete blocks

  • Syiemiong, Hopeful;Marthong, Comingstarful
    • Computers and Concrete
    • /
    • v.23 no.4
    • /
    • pp.267-272
    • /
    • 2019
  • In order to study the effect of moisture on the compressive strength of low-strength hollow concrete blocks, an experimental study was carried out on 96 samples of locally manufactured hollow concrete blocks collected from three different locations. Uniaxial compression tests were conducted on dry specimens and three types of saturated specimens with moisture contents of 30%, 50% and 80% respectively. The range of moisture content adopted covered the range within which the concrete block samples are saturated in the dry and monsoon seasons. The compressive strength of low-strength hollow concrete blocks decreases with increase in moisture content and the relationship between compressive strength of hollow concrete blocks and their moisture content can be considered to be linear. However, the strength degradation of 30% moist concrete blocks with respect to dry blocks is relatively low and can be considered to be comparable to dry concrete blocks. A formula indicating the relationship between the moisture content and compressive strength of low-strength hollow concrete blocks is also proposed.

A study of the hollow cathode discharge (HOLLOW CATHODE DISCHARGE의 방전 특성 연구)

  • Cho, S.M.;Seo, Y.W.;Kim, M.J.;Whang, K.W.
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.139-141
    • /
    • 1989
  • The characteristics of the hollow cathode discharge were investigated. Temperature distribution of the hollow cathode was investigated and I-V curves of the hollow cathode discharge were obtained. In this paper variables are chamber pressure, Ar gas flow rate injected through the cathode tube and the gap distance between cathode and anode. The inter electrode electron temperature and density were measured by Langmuir probe.

  • PDF

Electrorheology of Hollow Polyaniline Pimelate Suspension by Conduction Model

  • Choi Ung-Su
    • KSTLE International Journal
    • /
    • v.7 no.1
    • /
    • pp.1-4
    • /
    • 2006
  • The electro rheological behavior of the hollow polyaniline pimelate suspension in silicone oil was investigated. Hollow polyaniline pimelate suspension showed a typical ER response (Bingham flow behavior) upon application of an electric field. The shear stress for the suspension exhibited the dependence with a factor equals to 0.84 power on the electric field. The experimental results for the hollow polyaniline pimelate suspension correlated with the conduction models of Tang et al., and this suspension behaved as an ER fluid.

Rheology of Hollow Polyaniline Gutarate Suspension Under DC Electric Field

  • Choi, Ung-Su
    • KSTLE International Journal
    • /
    • v.9 no.1_2
    • /
    • pp.36-38
    • /
    • 2008
  • The electrical and rheological behavior of the hollow polyaniline glutarate suspension in silicone oil was investigated. Hollow polyaniline glutarate suspension showed a typical ER response (Bingham flow behavior) under a DC electric field. The shear stress for the suspension exhibited the dependence with a factor equals to 0.95 power on the electric field. The experimental results for the hollow polyaniline glutarate suspension behaved as an ER fluid.

One-Way Shear Strength of Donut Type Biaxial Hollow Slab Considered Hollow Shapes and Materials (중공형상 및 재료의 영향을 고려한 도넛형 이방향 중공슬래브의 일방향 전단강도)

  • Chung, Joo-Hong;Lee, Seung-Chang;Choi, Chang-Sik;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.4
    • /
    • pp.391-398
    • /
    • 2012
  • This paper presents the shear capacities of biaxial hollow slab with donut type hollow sphere. Recently, various types of slab systems which can reduce self-weight of slabs have been studied for increasing constructions of taller and larger building structures. A biaxial hollow slab system is widely known as one of the effective slab system, which can reduce self-weight of slab. According to previous studies, the hollow slab has low shear strength, compared to solid slab. Also, the shear capacities of biaxial hollow slab are influenced by the shapes and materials of hollow spheres. However, the current code does not provide a clear computation method for the shear strength of hollow slab. To verify the shear capacities of this hollow slab, one-way shear tests were performed. Four test specimens were used for test parameters. One was conventional RC slab and others were hollow slabs. The test parameters included two different shapes and materials of plastic balls. The shape parameters were donut and non-donut forms and the material parameters were general plastic and glass fiber plastic. The results showed that the shear strengths varied depending on hollow shapes and materials used in the slab.

A Study on the Displacement Behavior Safety of Cylindrical Hollow Rollers (원통형 중공롤러의 변형거동 안전성에 관한 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.1
    • /
    • pp.41-45
    • /
    • 2014
  • This paper presents an analytical study on the displacement behavior safety of cylindrical hollow rollers. Using the finite element method, the hollow roller with Y-shaped column structures between three tubes has been developed to analyze the displacement behavior safety. For the same dimension and weight of two hollow roller models, the displacement behavior safety of a typical hollow roller is lower 4~6.6% than that of the newly designed hollow roller with Y-shaped column structures between three tubes. Thus, this paper recommends Y-shaped hollow roller for increasing the roller strength safety and decreasing a total roller weight, which may save a consuming electrical energy.

Fabrication and Photocatalytic Activity of TiO2 Hollow Structures using One-pot Wet Chemical Process (One-pot 습식화학공정을 이용한 TiO2 중공 구조체 제조 및 광촉매 활성 연구)

  • Lee, Duk-Hee;Park, Kyung-Soo;Park, Jae-Ryang;Lee, Chan-Gi
    • Journal of Powder Materials
    • /
    • v.27 no.2
    • /
    • pp.132-138
    • /
    • 2020
  • A facile one-pot wet chemical process to prepare pure anatase TiO2 hollow structures using ammonium hexafluorotitanate as a precursor is developed. By defining the formic acid ratio, we fabricate TiO2 hollow structures containing fluorine on the surface. The TiO2 hollow sphere is composed of an anatase phase containing fluorine by various analytical techniques. A possible formation mechanism for the obtained hollow samples by self-transformation and Ostwald ripening is proposed. The TiO2 hollow structures containing fluorine exhibits 1.2 - 2.7 times higher performance than their counterparts in photocatalytic activity. The enhanced photocatalytic activity of the TiO2 hollow structures is attributed to the combined effects of high crystallinity, specific surface area (62 ㎡g-1), and the advantage of surface fluorine ions (at 8%) having strong electron-withdrawing ability of the surface ≡ Ti-F groups reduces the recombination of photogenerated electrons and holes.