• Title/Summary/Keyword: Holding Voltage

Search Result 174, Processing Time 0.024 seconds

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.

Effect of Different Stunning Time on Meat Quality of Broiler (육계 도축 시 전기 실신 시간이 육질에 미치는 영향)

  • Chae, H.S.;Ahn, C.N.;Yoo, Y.M.;Ham, J.S.;Jeong, S.G.;Lee, J.M.;Choi, Y.I.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.6
    • /
    • pp.1017-1024
    • /
    • 2005
  • This study was investigated the effect of the length of stunning time on pH, water holding capacity(WHC), cooking loss(CL), meat color and incidence rate of blood spot in broiler carcass. One-hundred and forty broiler chickens were slaughtered by three different length of stunning times(5 sec., 8 sec., 11 sec.) with the same electrical frequency(255Hz) and 50 voltage in a commercial abattoir. The WBS values and cooking loss of breast muscle were increased with increasing the stunning time, while WHC of breast muscle were decreased. Lightness(L* value) and yellowness(b* value) scores of leg muscle and skin stunned with 50V, 255Hz, 8 sec, 11 sec. were higher than those of broilers stunned with 50V, 255Hz, 5sec(P<0.05). But, there was no significant difference in color on breast and wing muscle. In subjective evaluation, frequence of the first grade had a trend of being increased by extending the stunning time. There was only a few cases of PSE chicken with 0.02%, while blood spot was observed at the highest rate for the 5 sec. treatment. TBARS indicated that a longer length of stunning resulted in a higher rate of fat oxidation. This experiment demonstrated that the length of stunning time has a significant effect on meat quality and its stability during chiller storage.

Ionic currents elicited by the hypotonic solution in hamster eggs (저장성 용액에 노출된 햄스터 난자에 관찰되는 이온전류의 변화)

  • Choi, Won-yeong;Kim, Yang-mi;Haan, Jae-hee;Huh, Il-oh;Park, Choon-ok;Hong, Seong-geun;Pyu, Pan-dong;Kim, Jong-shu
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.2
    • /
    • pp.305-312
    • /
    • 1996
  • Cell volume regulatory mechanisms are usually disclosed by exposure of cell to anisotonic media. If a cell is suddenly exposed to hypotonic media, it swells initially like an osmometer but within minutes regains its original cell volume. This behavior has been labelled as regulatory cell volume decrease(RVD). RVD is believed to result from the loss of permeable ions through the membrane. In this study, we examined hypotonically induced changes in the membrance currents involved in RVD by using whole cell voltage clamp technique in the unfertilized hamster egg. At -40mV of the holding potential, the stationary current was maintained in the hamster egg exposed to isotonic solution composed of, mainly, 115mM NaCl and 40mM mannitol. Hypotonic solution was prepared by removing mannitol. Therefore, the concentrations of $Na^+$ and $Cl^-$ in this hypotonic media were the same as those in the isotonic solution. Following 30 to 60 sec after applying the hypotonic media to the egg, the inward current was evoked. This inward current was eliminated by $100{\mu}M$ 4-acetamido-4'-isothiocyanostil-bene-2,2'-disulfonic acid(SITS), an anion channel blocker, leaving the small outward current component. Further addition of 2mM $Ba^{2+}$, a broad $K^+$ channel blocker, completely abolished the small outward current left even in the presence of SITS during hypotonic stress. These results suggest that $K^+$ and $Cl^-$ move out of cells, resulting in RVD. To test the involvement of $Na^+$ in RVD, 20mM Na-isethionate was substituted for mannitol in isotonic media(135mM $Na^+$) and Na-isethionate (20mM) was freed the hypotonic solution. Only $Cl^-$ concentration in both isotonic and hypotonic media was kept constant at 115mM, whereas concentration of $Na^+$ was lowered in hypotonic solution to 115mM from 135mM in isotonic solution. Hypotonic medium induced the outward current in the egg equilibrated isotonically. This current was reduced by $100{\mu}M$ SITS but was augmented by 2 mM $Ba^{2+}$. In terms of RVD, these results imply that $Cl^-$ efflux is coupled with $K^+$, maybe for electroneutrality during hypotonic stress and/or with $Na^+$ via unknown transport mechanism(s). From the overall results, the hypotonic stress facilitates the movement of $Cl^-$ and $K^+$ out of the hamster egg to regain cellular volume with electroneutrality. If there exist a difference in $[Na^+]_0$ between isotonic and hypotonic solution, another transport mechanism concerned with $Na^+$ may, at least partly, participate in regulatory volume decrease.

  • PDF

The role of $Na^+-Ca^{2+}$ exchange on calcium activated chloride current in single isolated cardiac myocyte in pulmonary vein of rabbit.

  • Kim, Won-Tae;Lee, Yoon-Jin;Ha, Jeong-Mi;Han Choe;Jang, Yeon-Jin;Park, Chun-Sik;Lee, Chae-Hun m
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 2003.06a
    • /
    • pp.37-37
    • /
    • 2003
  • We have shown the $Ca^{2+}$-activated chloride current is present in cardiac myocyte in rabbit pulmonary vein (Kim et al., 2002). This current amplitude was increased as [N $a^{+}$]$_{i}$ was increased and we suggested this chloride current may be involve in the spontaneous action potential frequency change. Since this current is activated by the increase of intracellular $Ca^{2+}$, we would like to test what is the inducer of the increase of [C $a^{2+}$]$_{i}$ between a L-type $Ca^{2+}$-current or a reverse mode of N $a^{+}$-C $a^{2+}$ exchange current. White rabbit (1.5 kg) was used and anesthetized with Ketamin (100 mg/kg). Pulmonary vein (PV) was isolated and sleeve area between left atrium and PV was dissected. Using collagenase (Worthington 0.7 mg/cc), single cardiac myocytes were isolated. In the presence of 15 mM of N $a^{+}$, three steps of voltage pulses were applied (holding potential : -40 ㎷, -80 ㎷ for 50 msec, 30 ㎷ for 5 msec, 10 ㎷ steps from -70 ㎷ to 60 ㎷). The inward and outward tail current was activated after brief 5 msec prepulse. The outward tail current was blocked by the removal of extracellular chloride substituted by glucuronic acid or by a chloride channel blocker, 5 mM 9-AC. But the inward tail current was still remained even though the amplitude was decreased. The reversal potentials were changed to the direction of the change of chloride equilibrium potential ( $E_{Cl}$ ) but the shift of equilibrium potential was not enough to match to the theoretical equilibrium potential shift. In the presence of L-type $Ca^{2+}$ channel blocker, nifedipine 1 uM, inward tail currents were greatly reduced but the outward current tail currents were still remained. In the presence of N $a^{+}$-C $a^{2+}$ exchange current blocker, 10 uM KB-R7943, the inward and outward tail currents were blocked almost completely. We tried to test the $Ca^{2+}$sensitivity of the chloride current with various [C $a^{2+}$]$_{i}$ in pipette solution from 100 nM to 1 uM but we failed to activate $Ca^{2+}$-activated chloride currents even though the cell became contracted in the presence of 1 uM $Ca^{2+}$. From these results, we could conclude that the increase of [C $a^{2+}$]$_{i}$ to activate the outward $Ca^{2+}$-activated chloride current was mainly induced by the activation of the reverse mode of N $a^{+}$-C $a^{2+}$ exchanger, But for the increase of [C $a^{2+}$]$_{i}$ to activate the inward tail current, L-type $Ca^{2+}$ current may be the major provoking current. Since the cytosolic increase of [C $a^{2+}$]$_{i}$ through pipette solution have failed to activate $Ca^{2+}$-activated chloride current, this chloride current may have very low $Ca^{2+}$ sensitivity or a comparmental increase $Ca^{2+}$ such as in subsarcolemmal space may activate the chloride current. Since there are several reports and models that the increase of $Ca^{2+}$ in subsarcolemmal space would be over several to tens of uM, both possibility may be valid together.uM, both possibility may be valid together.

  • PDF