• Title/Summary/Keyword: Hip support

Search Result 126, Processing Time 0.022 seconds

EMS Application Effect of Lower Extremities to Improve Static Balance Capability (정적 균형능력 향상을 위한 하지 의류의 EMS 적용 효과)

  • Hwang, Sunkyu;Park, Jinhee;Kim, Jooyong
    • Journal of Fashion Business
    • /
    • v.25 no.4
    • /
    • pp.151-160
    • /
    • 2021
  • The purpose of this study was to investigate whether there were improvements on balance when both ankle-jointed calf muscles and hip muscles, which affect balance capabilities, were activated through taping techniques and EMS. In this study, the One Leg Standing Test, a static balance test, was conducted by experimenting on a flat floor, foam pad, and a stretching board with a gradient of 20 degrees, respectively, to study static balance capabilities in different situations. Nine healthy men in their 20s were measured five times every five minutes considering muscle fatigue, and the difference between each variable was analyzed through post-test using nonparametric statistical analysis. Our results showed an equal increase in static balance capability was similar when EMS was applied only to calf muscles and only to hip muscles. Notably most improvements were seen when wearing calf supporters and taping technology pants, and applying EMS together. It was also found that the difference between EMS electric stimulation and balance capability was greater when wearing and applying supporters and taping technology pants. Based on the results of the present study, a muscle support band and EMS of taping techniques can improve balance capabilities. These findings are expected to form a basis for solutions Improving the balance capabilities

Compression Wear Design for Women's Soccer Players (여자 축구선수를 위한 컴프레션 웨어 설계)

  • Park, Sanghee
    • Journal of Fashion Business
    • /
    • v.25 no.2
    • /
    • pp.127-142
    • /
    • 2021
  • This study aims to organize the prototype design method of compression wear for women professional soccer players. Despite the excellent performance of female soccer players in world competition, most functional wear has been developed mainly for men, so professional female athletes have fewer choices. Soccer is a sport requiring core and lower body muscle strength, and muscular endurance for long periods of playing or walking on the field. Female soccer players did not differ much in upper body compared to other women, but their lower body had a smaller hip circumference than waist circumference and a larger thigh circumference, requiring compilation considering the physical characteristics and movement of athletes. Female soccer players wear sports bras while playing but regular bras and compression wear during normal exercise because they sweat on under their breast, which irritates sensitive skin. For core muscles in the upper body and to support for thigh and hip muscles in the lower body, the uniform in this study was designed by reducing the body size of a professional female soccer player in her 20s and the actual measurements of commercial compilation software to 81% of the chest circumference, 95% of the waist circumference, and 78% of the hip circumference. The design experiment in this study was a simple exercise and did not produce produce results for long-term exercise and performance improvement, but can be used to design a composition pattern system for other professional female athletes.

Contributions of the Lower Extremity Joint on the Support Moment in Normal Walking and in Unexpected Step-down Walking

  • Kim Young-Ho;Kim Han Sung;Hwang Sung-Jae;Myeong Seong-Sik;Keum Young-Kwang
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.spc1
    • /
    • pp.371-376
    • /
    • 2005
  • Relative contributions of lower extremity joints on the support moment were investigated in this study. Three-dimensional gait analyses were performed in normal walking and in unexpected step-down walking. For both gait studies, inverse dynamics were performed to obtain each joint moment of the lower extremity, which was applied to the forward dynamics simulation to determine the contributions on the support moment at different phases of walking. The forward dynamic simulation results showed that, in normal walking, the ankle plantar flexors contributed significantly during single-limb-support. However, the ankle plantar flexors, knee extensors and hip extensors worked together during double-limb-support. In unexpected step-down walking, the important contributors on the support of the body during single-limb-support were not only ankle plantar flexors but also knee extensors. This study, analyzing the relative contributions of the lower limb joint moments for the body support, would be helpful to understand different unexpected walking conditions and compensatory mechanisms for various pathological gaits.

Shape deformation and wear sensation in wearing on support type panty stocking (고탄력 팬티스타킹 착용에 의한 형태변형 및 착용감)

  • 류현혜;성수광
    • Journal of the Ergonomics Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.37-57
    • /
    • 1995
  • The purpose of this study was to investigate the elastic effect of deformation and restriction in wearing a support type panty stocking (PS). The study investigated deformation rate in all surface area, deformation rate in local area, length deformation rate, changes in slip and feeling of restriction under the standard laboratory condition. Two healthy adult females in twenties wore four types of PS. The result were as follows : The deformation rate in all surface area was 117 .approx. 132% in wearing support type PS, 157% in wearing mono type PS, due to the intensities of restriction. The deformation rate in local area was in order, course > oblique > wale direction. The largest deformation rate was observed in hip girth. Between the deformation rates in all surface and local areas was a high correlation acknowledged, especially the course direction showed a high correlation. Support type PSs showed more deformation and changes of slip than wool and mono type PS. Especially, changes of slip at the knee appeared greatly. The responses of restriction evaluated from a paired comparison method were in order, JS 2 > KS 4 > KS 9 > KS 5 > KS 1 > KM 3.

  • PDF

Gait Analysis of Patients with Tumor Prosthesis around the Knee (인공 종양대치물을 이용한 사지구제술후의 보행 분석)

  • Lee, Sang-Hoon;Chung, Chin-Youb;Kim, Han-Soo;Kim, Byung-Sung;Lee, Han-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.3 no.1
    • /
    • pp.18-25
    • /
    • 1997
  • Prosthetic replacement is one of the most common methods of reconstruction after resection of malignant tumor around the knee. Gait analysis provides a relative objective data about the gait function of patients with prosthesis. The purpose of this study was to compare the gait pattern of the patients who underwent limb salvage surgery with prosthesis for distal femur and that of patients with prosthesis for proximal tibia. This study included ten patients (4 males, 6 females, mean age 22.7 years, range 14-36) who underwent a wide resection and Kotz hinged modular reconstruction prosthesis replacement and six normal adult(Control). The site of bone tumor was the distal femur (Group 1) in six patients and proximal tibia (Group 2) in 4 patients. The follow-up period ranged from 15 to 82 months (mean : 33 months). The evaluation consisted of clinical assessment, radiographic assessment, gait analysis using VICON 370 Motion Analysis System. The gait analysis included the linear parameters such as, walking velocity, cadence, step length, stride length, stance time, swing time, single support and double support time and the three-dimensional kinematics (joint rotation angle, velocity of joint rotation) of ankle, knee, hip and pelvis in sagittal, coronal and transverse plane. For the kinetic evaluation, the moment of force (unit: Nm/kg) and power (unit: Watt/kg) of ankle, knee and hip joint in sagittal, coronal and transverse plane. In the linear parameters, cadence, velocity, step time and single support were decreased in both group 1 and group 2 compared with control. Double support decreased in group 2 compared with control significantly(p<.05). In contrast to our hypothesis, there was no significant difference between group 1 and group 2. In Kinematics, we observed significant difference (p<.05) of decreased knee flexion in loading response (G2

  • PDF

Properties Variation According to Heat Treatment for Gas Turbine Blade(Bucket) Material of GTD-111DS (GTD-111DS 가스터빈 블레이드 재질의 열처리에 따른 재질 특성변화)

  • Park Sang-Yeal;Yang Sung-Ho;Kim Moon-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.3 s.246
    • /
    • pp.349-355
    • /
    • 2006
  • The gas turbine components is used on high temperature conditions which under severely circumstance with start-up and stop several times. Therefore, it is used nickel-base superalloys like and GTD-111DS. Damaged buckets on the t긴ade tip during operating are repaired per 24,000 hr to three times according to repair specification of manufacture. It is applied pre-heat, HIP(hot isostatic pressing) and post-heat treatment to support welding repair on blade tip effectively. On this study, It is utilize of $WRAP^{TM}$ (welding repair advanced process) method to make tension test specimens for this study, And then, material strength and characteristic for GTD-111DS was analyzed.

The Effects of Clothing Styles and Colors on a Body Image Perception (의복스타일과 색이 신체이미지 지각에 미치는 영향)

  • Kim, Hyo-Sook;Choi, Chang-Seok;Lee, Eun-Sil
    • Journal of the Korean Home Economics Association
    • /
    • v.41 no.9
    • /
    • pp.135-148
    • /
    • 2003
  • The purpose of this study was to examine the effect of clothing colors, clothing styles on women's body image perception. The experimental design was 2${\times}$2${\times}$9(perceiver's gender ${\times}$clothing styles${\times}$clothing colors) factorial design with between-subjects design. Subjects were 320 college students in the metropolitan area of Seoul. Perceiver's gender, clothing styles, and clothing colors gave a significant influence on the 3 variables of shoulder, the upper half of the body, and bust. Shoulder and the upper half of the body had an interaction effect by clothing styles and clothing color. Perceiver's gender gave a significant influence on hip size, length of leg, height, clothing styles did a significant influence on hip size, length of leg, height, and slender figure. Clothing colors gave a significant influence on length of leg, height, and slender figure. Length of leg and slender figure had an interaction effect by perceiver's gender and clothing styles. Hip size had an interaction effect by perceiver's gender and clothing color. Hip size had an interaction effect by clothing styles and clothing color. The results of this study support that coloration of clothing and clothing style affects perception of stimulus persons wearing apparel.

Postoperative Irradiation for Prevention of Heterotopic Bone Formation after Total Hip Replacement Arthroplasty (고관절전치환 성형술 후 관절주위 골형성 예방을 위한 수술 후 방사선 요법)

  • Park Woo Yoon;Kim Il Han;Ha Sung Whan;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.4 no.1
    • /
    • pp.75-80
    • /
    • 1986
  • Heterotopic bone formation is a complication which occurs in 0.6 to $61.7\%$ of patients after total hip replacement arthroplasty. We reviewed 4 patients (8 hips) who received postoperative irradiation on their hi ps for prevention of heterotopic bone formation in the Department of Therapeutic of Therapeutic Radiology, Seoul National University versify Hospital from January 1981 through August 1985. Radiation therapy was started 6 to 10 days postoperatively with the dosage of 2,000 cGy given in 10 fractions. As a result, 7 hips had Grade 0 and 1 hip had Grade 1 heterotopic ossification according to modified Blocker system. Our result and review of the literatures strongly support that the postoperative radiotherapy is effective for prevention of heterotopic bone formation in high risk group.

  • PDF

Feature Extraction and Evaluation for Classification Models of Injurious Falls Based on Surface Electromyography

  • Lim, Kitaek;Choi, Woochol Joseph
    • Physical Therapy Korea
    • /
    • v.28 no.2
    • /
    • pp.123-131
    • /
    • 2021
  • Background: Only 2% of falls in older adults result in serious injuries (i.e., hip fracture). Therefore, it is important to differentiate injurious versus non-injurious falls, which is critical to develop effective interventions for injury prevention. Objects: The purpose of this study was to a. extract the best features of surface electromyography (sEMG) for classification of injurious falls, and b. find a best model provided by data mining techniques using the extracted features. Methods: Twenty young adults self-initiated falls and landed sideways. Falling trials were consisted of three initial fall directions (forward, sideways, or backward) and three knee positions at the time of hip impact (the impacting-side knee contacted the other knee ("knee together") or the mat ("knee on mat"), or neither the other knee nor the mat was contacted by the impacting-side knee ("free knee"). Falls involved "backward initial fall direction" or "free knee" were defined as "injurious falls" as suggested from previous studies. Nine features were extracted from sEMG signals of four hip muscles during a fall, including integral of absolute value (IAV), Wilson amplitude (WAMP), zero crossing (ZC), number of turns (NT), mean of amplitude (MA), root mean square (RMS), average amplitude change (AAC), difference absolute standard deviation value (DASDV). The decision tree and support vector machine (SVM) were used to classify the injurious falls. Results: For the initial fall direction, accuracy of the best model (SVM with a DASDV) was 48%. For the knee position, accuracy of the best model (SVM with an AAC) was 49%. Furthermore, there was no model that has sensitivity and specificity of 80% or greater. Conclusion: Our results suggest that the classification model built upon the sEMG features of the four hip muscles are not effective to classify injurious falls. Future studies should consider other data mining techniques with different muscles.

Comparative Analysis of Gait Parameters and Symmetry between Preferred Walking Speed and Walking Speed by using the Froude Number

  • Yoo, Si-Hyun;Kim, Jong-Bin;Ryu, Ji-Seon;Yoon, Suk-Hoon;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.2
    • /
    • pp.221-228
    • /
    • 2016
  • Objective: The purpose of this study was to investigate differences in gait parameters and symmetry between walking speed by using the Froude number and preferred walking speed. Method: Fifty adults (age: $21.0{\pm}1.7years$, body weight: $71.0{\pm}9.2kg$, height: $1.75{\pm}0.07m$, leg length: $0.89{\pm}0.05m$) participated in this study. Leg length-applied walking speed was calculated by using the Froude number, defined as Fr = ${\upsilon}^2$/gL, where v is the velocity, g is the gravitational acceleration, and L is the leg length. Video data were collected by using eight infrared cameras (Oqus 300, Qualysis, Sweden) and the Qualisys Track Manager software (Qualisys, Sweden), with a 200-Hz sampling frequency during two-speed walking (preferred walking speed [PS] and leg length-applied walking speed [LS]) on a treadmill (Instrumented Treadmill, Bertec, USA). The step length, stride length, support percentage, cadence, lower joint angle, range of motion (ROM), and symmetry index were then calculated by using the Matlab R2009a software. Results: Step and stride lengths were greater in LS than in PS (p < 0.05). The right single-support percentage was greater in LS than in PS (p < 0.05). The hip joint angle at heel contact and toe-off were greater in LS than in PS (p < 0.05). The hip and knee joint ROM were greater in LS than in PS (p < 0.05). Conclusion: Based on our findings, we suggest that increased walking speed had a significant effect on step length, stride length, support percentage, and lower joint ROM.