• Title/Summary/Keyword: Hip prosthesis

Search Result 54, Processing Time 0.023 seconds

Structural Analysis and Design of Artificial Hip Joint by Using Finite Element Method (유한요소법을 이용한 인공 고관절의 역학적 거동 해석 및 설계)

  • 정재연;황운봉;하성규
    • Composites Research
    • /
    • v.12 no.5
    • /
    • pp.98-109
    • /
    • 1999
  • An investigation has been performed to develop a nonlinear finire element method for the analysis of the long-term behavior of an artificial hip joint. The three dimensional multi-layered brick element is used to analyze the design performances of hip prodtheses with various materials and the thick laminated composite hip prostheses with various layup sequences. The used element can accommodate the varying material properties of the element and allow the ply-drop-off along the eleement edge. The nonlinear finite element analysis program has been verified by the comparison with the exact solution of the bean problem subjected to uniaxial loading. By using the program, the density changes and strength ratios of artificial hip joint are calculated according to the hip prosthesis materials and the layers of composite hip prosthesis. The numerical results are easily applied to evaluate design performances of a hip prosthesis, and decrease the difficulty and time of hip prosthesis design.

  • PDF

Comparative study by the finite element method of three activities of a wearer of total hip prosthesis during the postoperative period

  • Abdelmadjid Moulgada;Mohammed El Sallah Zagane;Murat Yaylaci;Ait Kaci Djafar;Sahli Abderahmane;Sevval Ozturk;Ecren Uzun Yaylaci
    • Structural Engineering and Mechanics
    • /
    • v.87 no.6
    • /
    • pp.575-583
    • /
    • 2023
  • The postoperative period for a carrier of total hip prosthesis (THP), especially in the first months, remains the most difficult period for a patient after each operation, even if traumatologist surgeons want the relief and success of their operations. In this investigation, selected three of the daily activities for a wearer of total hip replacement (THR), such as sitting in a chair, lifting a chair, and going downstairs, and was performed a numerical simulation by finite elements based on experimental data by Bergmann (Bergmann 2001) in terms of effort for each activity. Different stresses have been extracted, and a detailed comparison between two activities with different induced stresses such as normal, tensile, and compressive shear stresses.

Hip Arthroplasty Using the Bencox® Hip System: An Evaluation of a Consecutive Series of One Thousand Cases

  • Lee, Joong-Myung;Sim, Young-Suk;Choi, Dae-Sung
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.210-218
    • /
    • 2018
  • Purpose: This is a report on the outcomes associated with a consecutive series of 1,000 cementless hip arthroplasties utilizing the $Bencox^{(R)}$ hip stem-the first Korean-developed hip prosthesis. Materials and Methods: A consecutive series of 1,000 hip arthroplasties using the $Bencox^{(R)}$ hip stem were analyzed, starting from its initial release (September 2006) until June 2014. Patients in this consecutive series underwent surgery for fractures (n=552), arthritis (n=155), avascular necrosis (n=209), and revisions (n=84). Of these 1,000 cases, patients with a minimum follow-up of at least 1 year (n=616) were retrospectively analyzed for radiographic and clinical outcomes (i.e., Harris hip score). The stability of the prosthesis was evaluated by examining subsidence. Results: During the follow-up period (mean follow-up period of 54.8 months), there were 2 cases requiring revision of the femoral stem-both were caused by periprosthetic fractures and neither involved stem loosening. The mean Harris hip score during follow-up was 95.5. Bone ongrowth occurred in 95% of patients; no cases of subsidence or aseptic loosening of the stem were detected, and no cases of postoperative complications such as ceramic breakage were observed. Conclusion: Clinical and radiographic evaluations of hip arthroplasty using the $Bencox^{(R)}$ hip stem revealed excellent outcomes with an average of 54.8 month follow-up in a consecutive series of 1,000 cases.

Optimal Design of Stem Shape for Artificial Hip Prosthesis with Unbonded Cement Mantle (시멘트 비접착 인공 고관절의 주대 형상 최적 설계)

  • Choi, Don-Ok;Yoon, Yong-San
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.932-938
    • /
    • 2001
  • This study is concerned with the shape optimization of stem for the artificial hip prosthesis with unbonded cement mantle. The artificial hip prosthesis with unbonded cement mantle allows a stem to slip on cement mantle because of polished stem surface. Unbonded cement mantle type has several advantages compared with bonded cement mantle type, for example, small micro motion, preventing stress shielding and so on. In this study, 2-dimensional axisymmetric model was developed with considering characteristics of unbonded cement mantle. Moreover, optimal shape of stem was obtained by using feasible direction method. The objective of this optimization is maximizing supported vertical loading. The slip motion and stresses of stem, cement mantle and bone is used for constraints. The optimal shape which obtained by this study has slope of 0.15 in proximal part and maintains the width about 5mm in distal part In addition, simplified 3-dimensional analysis which applying optimal shape is carried out. The result of 3-dimensional analysis showed that optimal shape has some advantages for cement mantle stress. However, more realistic 3-dimensional analysis which including bending effect, complex geometries etc. is needed in further research.

  • PDF

Numerical simulation of the total hip prosthesis under static and dynamic loading (for three activities)

  • Mohammed El Sallah Zagane;Abdelmadjid Moulgada;Murat Yaylaci;Sahli Abderahmen;Mehmet Emin Ozdemir;Ecren Uzun Yaylaci
    • Structural Engineering and Mechanics
    • /
    • v.86 no.5
    • /
    • pp.635-645
    • /
    • 2023
  • This study aims to simulate the mechanical behavior of the total prosthesis model of Charnley (CMK3) by the 3D finite element method and to determine the state of the stresses in the femoral components (prosthesis, cement, and bone). The components are subjected to a dynamic load due to three activities (normal walking, climbing stairs, and standing up a chair). Static loading is by selecting the maximum load for the same activities mentioned. The results show that the maximum stresses in the proximal part of the cement are very important. Moreover, new results obtained for different parameters were discussed in detail. It is understood that current research provides important lessons for the surgeon to contribute to the clinical diagnosis of durable implantations and a better understanding of the process of bone remodeling and bone prosthesis.

Behavior Analysis of the Treated Femur and Design of Composite Hip Prosthesis (대퇴부 거동 해석 및 복합재료 보철물 설계)

  • 임종완;하성규
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.119-130
    • /
    • 2002
  • The nonlinear finite element program has been developed to analyze the design performance of an artificial hip prosthesis and long term behavior of a treated femur with stems made of composite material after cementless total hip arthroplasty(THA). The authors developed the three dimentional FEM models of femoral bone with designed composite stem which was taken with elliptic cross section of 816 brick elements under hip contact load and muscle farce in simulating single leg stand. Using the program, density changes, stress distributions and micromotions of the material femoral bone were evaluated by changing fiber orientation of stems for selected manufacturing method such as plate cut and bend mold. The results showed that the composite materials such as AS4/PEEK and T300/976 gave less bone resorption than the metallic material such as cobalt chrome alloy, titanium alloy and stainless steal. It was found that increasing the long term stability of the prosthesis in the femur could be obtained by selecting the appropriate ply orientation and stacking sequence of composite.

Dental Prosthesis Causing Pneumonia in a Delirious Elderly Patient after Hip Fracture Surgery (고관절 골절 수술후 발생한 섬망환자의 치과보철물에 의한 폐렴)

  • Lee, Young-Kyun;Ha, Yong-Chan;Koo, Kyung-Hoi
    • Journal of Trauma and Injury
    • /
    • v.25 no.3
    • /
    • pp.97-100
    • /
    • 2012
  • We report a case of delayed diagnosed pneumonia due to an aspirated metallic crown, which had been detached from a molar tooth. Dental prosthesis should be checked and a careful review of the chest radiograph is mandatory when an elderly patient with delirium after hip fracture surgery develops pneumonia postoperatively.

Modeling and Posture Control of Lower Limb Prosthesis Using Neural Networks

  • Lee, Ju-Won;Lee, Gun-Ki
    • Journal of information and communication convergence engineering
    • /
    • v.2 no.2
    • /
    • pp.110-115
    • /
    • 2004
  • The prosthesis of current commercialized apparatus has considerable problems, requiring improvement. Especially, LLP(Lower Limb Prosthesis)-related problems have improved, but it cannot provide normal walking because, mainly, the gait control of the LLP does not fit with patient's gait manner. To solve this problem, HCI((Human Computer Interaction) that adapts and controls LLP postures according to patient's gait manner more effectively is studied in this research. The proposed control technique has 2 steps: 1) the multilayer neural network forecasts angles of gait of LLP by using the angle of normal side of lower limbs; and 2) the adaptive neural controller manages the postures of the LLP based on the predicted joint angles. According to the experiment data, the prediction error of hip angles was 0.32[deg.], and the predicted error of knee angles was 0.12[deg.] for the estimated posture angles for the LLP. The performance data was obtained by applying the reference inputs of the LLP controller while walking. Accordingly, the control performance of the hip prosthesis improved by 80% due to the control postures of the LLP using the reference input when comparing with LQR controller.