• Title/Summary/Keyword: Hip Fracture

Search Result 178, Processing Time 0.024 seconds

Stress Analysis of Femoral Stems on Non-Cemented Total Hip Replacement - A Three-Dimensional Finite Element Analysis -

  • Kim, Sung-Kon;Chae, Soo-Won;Jeong, Jung-Hwan
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.263-266
    • /
    • 1997
  • Three dimensional numerical model based on the finite element method(FEM) were developed to predict the mechanical behavior of hip implants. The purpose of this study is to investigate the stress distribution of two types of cementless total hip replacement femoral component -a straight stem and a curved stem, and to compare their effect on the stress shielding between two types by three dimensional finite element method. The authors analyzed von Mises stress in the cortex & stem and compared the stress between the straight and the curved stem. In comparison of stresses between two different design of femoral stem, there was 25% more decrease of stress in straight stem than curved stem in the medial cortex at proximal region. The straight stem had consistently much lower stresses than the curved stem throughout the whole medial cortex with maximum 70% reduction of stress. However, there was little change in stress between nature and 2 implanted femur throughout the lateral cortex. Stress of femoral stem was much higher in the straight stem than the curved stem up to 60%. The straight stem had more chance of stress shielding and a risk of fatigue fracture of the stem compared with the curved stem in noncement hip arthroplasty. In design of femoral stem still we have to consider to develop design to distribute more even stress on the proximal medial cortex.

  • PDF

Finite element analysis of the femur fracture for a different total hip prosthesis (Charnley, Osteal, and Thompson)

  • Mohammed El Sallah Zagane;Moulgada Abdelmadjid;Murat Yaylaci;Sahli Abderahmen;Ecren Uzun Yaylaci
    • Structural Engineering and Mechanics
    • /
    • v.88 no.6
    • /
    • pp.583-588
    • /
    • 2023
  • Total hip replacement is a crucial intervention for patients with fractured hips who face challenges in natural recovery. The design of durable prostheses requires a comprehensive understanding of the natural processes occurring in bone. This article focuses on static loading analysis, specifically during stumbling activity, aiming to enhance the longevity of prosthetic implants. Three distinct implants, Charnley, Osteal, and Thompson, were selected for a detailed study to determine the most appropriate model. The results revealed critical insights into the distribution of Von Mises stresses on the components of femoral arthroplasty, including the cement, implant, and cortical bone. Furthermore, the examination of shear stress within the cement emerged as a pivotal aspect for all three implants, playing a crucial role in evaluating the performance and durability of hip prostheses. The conclusions drawn from this study strongly suggest that the Thompson model stands out as the most suitable choice for hip joint implants.

Effect of Microstructure on Evaluation of Fracture Toughness and Hardness of Cutting Tool Ceramics (절삭 공구용 세라믹의 소결조직에 따른 파괴인성과 경도의 평가)

  • 안동길;윤명진
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.6
    • /
    • pp.170-177
    • /
    • 2000
  • Dense $Al_2$O$_3$-30%TiC and Si$_3$N$_4$ ceramic tool materials with various grain size were produced by sintering-HIP treatment and by gas-pressure sintering. The fracture toughness was measured by indentation fracture and indentation strength method for both ceramics with various grain size. The effect of the grain size on the fracture toughness was evaluated, and the correlation between fracture toughness and mechanical properties such as hardness, Young\`s modulus and flexural strength of these ceramic were also investigated. The highest fracture toughness of around 6.7 MPa.m(sup)1/2 was obtained in Si$_3$N$_4$ ceramics with grain size of 1.58${\mu}{\textrm}{m}$. With a larger grain size of $Al_2$O$_3$-30%TiC and Si$_3$N$_4$ ceramics, the fracture toughness was generally increased. The increased fracture toughness of these ceramic also improved the flexural strength although the hardness decreased considerably. Similar results were obtained in grain size and mechanical properties on both $Al_2$O$_3$-30%TiC and Si$_3$N$_4$ ceramic tool materials.

  • PDF

Prevention of Venous Thromboembolism in Patients Undergoing Hip Fracture Surgery: A Survey of the Korean Hip Society

  • Chang Hyun Kim;Je-Hyun Yoo;Young-Kyun Lee;Ye-Yeon Won;Jong-Seok Park
    • Hip & pelvis
    • /
    • v.35 no.3
    • /
    • pp.200-205
    • /
    • 2023
  • Purpose: The aim of this study was to assess the current status of venous thromboembolism (VTE) prevention in Korean patients with hip fractures. Materials and Methods: A survey using a questionnaire on the experiences and protocols of VTE prevention was conducted among 570 members of the Korean Hip Society. Results: A total of 97 surgeons responded, with a response rate of 17.0%. Of the 97 participants, 61.9% answered that they had encountered one or more cases of symptomatic VTE in the past year. Mechanical prophylaxis was applied most often (30.9%) until the point of ambulation in standard-risk patients and most often (34.0%) extended until discharge in high-risk patients. Chemical prophylaxis was most often prescribed for a particular period of time rather than for recovery of walking ability (24.7% in standard-risk patients and 26.8% in high-risk patients). Dual prophylaxis was administered in the standard-risk group by 58.8% of the participants and in the high-risk group by 83.5%. Among the participants, 73.2% answered that they had been attentive to wound complications during chemical prophylaxis. More than half of the participants (59.8%) reported that they did not perform routine screening for VTE after surgery. Conclusion: The results of our survey provided information regarding the current status of VTE prevention for patients undergoing surgery for treatment of hip fractures in Korea as well as a baseline for establishment of educational programs and guidelines in the future.

$^{99m}Tc-Tin$ Colloid Uptake Ratio of Femoral Head in Healthy Korean (정상 한국인 대퇴골두의 $^{99m}Tc-Tin$ Colloid 섭취율)

  • Zhi, Won-Hee;Sohn, Hyung-Sun;Kim, Choon-Yul;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.215-218
    • /
    • 1989
  • Tc-99m-tin colloid distribution in the hip is studied in 76 patients with no hepatic and hip disorder, because knowledge of normal uptake pattern in the hip is important in evaluation of femoral head vasculature after a fracture. The uptake in femoral head is decreased or disappeared with increasing age due to conversion of red marrow to white marrow.

  • PDF

Mechanical Properties of Carbon/Carbon Composites Densified by HIP Technique

  • Manocha, L.M.;Warrier, Ashish;Manocha, S.;Banerji, S.;Sathiyamoorthy, D.
    • Carbon letters
    • /
    • v.6 no.1
    • /
    • pp.6-14
    • /
    • 2005
  • The study of mechanical properties and fracture behaviour of carbon/carbon composites is significant to its application and development. These are dependent on microstructure and properties of reinforcing fibers and matrix, fiber/matrix interface and porosity/cracks present in the composites. In the present studies high-density carbon/carbon composites have been prepared using PAN and various pitch based carbon fibers as reinforcements and pitch as matrix with repeated densification cycles using high-pressure impregnation and carbonization technique. Scanning electron microscopy has been used to study the fracture behaviour of the highly dense composites and correlated with structure of the composites. The geometry of reinforcement and presence of unfilled voids/cracks was found to influence the path of crack propagation and thereby the strength of composites. The type of stresses (tensile or compressive) accumulated also plays an important role in fracture of composites.

  • PDF

Outcomes of Internal Fixation with Compression Hip Screws in Lateral Decubitus Position for Treatment of Femoral Intertrochanteric Fractures

  • Park, Cheon-Gon;Yoon, Taek-Rim;Park, Kyung-Soon
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.254-259
    • /
    • 2018
  • Purpose: Internal fixation using compression hip screws (CHS) and traction tables placing patients in the supine position is a gold standard option for treating intertrochanteric fractures; however, at our institution, we approach this treatment with patients in a lateral decubitus position. Here, the results of 100 consecutive elderly (i.e., ${\geq}45$ years of age) patients who underwent internal fixation with CHS in lateral decubitus position are analyzed. Materials and Methods: Between March 2009 and May 2011, 100 consecutive elderly patients who underwent internal fixation with CHS for femoral intertrochanteric fracture were retrospectively reviewed. Clinical outcomes (i.e., Koval score, Harris hip score [HHS]) and radiographic outcomes (i.e., bone union time, amount of sliding of lag screw, tip-apex distance [TAD]) were evaluated. Results: Clinical assessments revealed that the average postoperative Koval score decreased from 1.4 to 2.6 (range, 0-5; P<0.05); HHS was 85 (range, 72-90); and mean bone union time was 5.0 (range, 2.0-8.2) months. Radiographic assessments revealed that anteroposterior average TAD was 6.95 (range, 1.27-14.63) mm; lateral average TAD was 7.26 (range, 1.20-18.43) mm; total average TAD was 14.21 (range, 2.47-28.66) mm; average lag screw sliding was 4.63 (range, 0-44.81) mm; and average angulation was varus $0.72^{\circ}$(range, $-7.6^{\circ}-12.7^{\circ}$). There were no cases of screw tip migration or nonunion, however, there were four cases of excessive screw sliding and six cases of varus angulation at more than $5^{\circ}$. Conclusion: CHS fixation in lateral decubitus position provides favorable clinical and radiological outcomes. This technique is advisable for regular CHS fixation of intertrochanteric fractures.

Mechanical safety evaluation of ceramic ball head for total hip replacement using finite element method (인공고관절 전치환술에서 세라믹 볼 헤드의 기계적 안정성 평가를 위한 유한요소 해석)

  • Han, Sung-Min;Chu, Jun-Uk;Chun, Heoung-Jae;Kim, Jung-Sung;Choi, Kui-Won;Youn, In-Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.6
    • /
    • pp.449-455
    • /
    • 2010
  • A ceramic articulating system in total hip replacement thought to be superior to metal-on-polyethylene due to its extremely low coefficient of friction and potential for high resistance to wear. But ceramic is brittle, which makes it mechanically and theoretically susceptible to fracture under certain mechanical conditions. In the current study, nine different models of ceramic ball heads were mechanically evaluated using 3D finite element(FE) analyses. It was found that the maximum stress in all ceramic models was lower than ceramic flexural strength, and it satisfied the requirements of the FDA Gaudience for artificial hip implant. Thus, ceramic ball head models introduced in the current study could be mechanically safe for clinical applications.

Comparison between Cementless and Cemented Bipolar Hemiarthroplasty for Treatment of Unstable Intertrochanteric Fractures: Systematic Review and Meta-analysis

  • Yoo, Jun-Il;Cha, Yong-Han;Kim, Kap-Jung;Kim, Ha-Yong;Choy, Won-Sik;Hwang, Sun-Chul
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.241-253
    • /
    • 2018
  • Purpose: This study was conducted to compare cemented and cementless bipolar hemiarthroplasty in elderly patients with unstable intertrochanteric fractures via meta-analysis and systematic review of relevant studies. Materials and Methods: Systematic review and meta-analysis were performed on 31 available clinical studies; 19 of these studies used cemented stems, 12 used cementless stems, one used both types of stems, and two studies involved a comparative analysis of both stem types. Results: There were statistically significant differences in rates of leg length discrepancy (LLD) greater than 1 cm between the cemented (event rate, 0.089) and cementless groups (event rate, 0.015 and 0.047; P=0.03). Conclusion: Cemented bipolar hemiarthroplasty and cementless bipolar hemiarthroplasty performed on elderly patients with unstable intertrochanteric fracture revealed similar mortality and complication rates; however, the rate of LLD greater than 1 cm was significantly higher in the cemented group compared with the cementless group.