References
- Y. S. Park, J. H. Kim, Y. H. Kim, and K. C. Park, "Osteonecrosis of Femoral Head after Pelvic Fracture," J Korean Orthop Assoc, vol. 44, pp. 495-498, 2009. https://doi.org/10.4055/jkoa.2009.44.4.495
- M. J. Fagan, and A. J. C. Lee, " Material selection in the design of the femoral component of cemented total hip replacements," Clinical Materials, vol. 1, no. 3, pp. 151-167, 1986. https://doi.org/10.1016/S0267-6605(86)80029-4
- B. Latham, and T. Goswami, "Effect of geometric parameters in the design of hip implants paper IV," Materials & Design, vol. 25, no. 8, pp. 715-722, 2004 . https://doi.org/10.1016/j.matdes.2004.01.012
- A. Ramos, and J. A. Simoes, "Tetrahedral versus hexahedral finite elements in numerical modelling of the proximal femur,", Medical Engineering & Physics, vol. 28, no. 9, pp. 916-924, 2005.
- B. Weisse, M. Zahner, W. Weber, and W. Rieger, "Improvement of the reliability of ceramic hip joint implants," Journal of Biomechanics, vol. 36, pp. 1633-1639, 2003. https://doi.org/10.1016/S0021-9290(03)00186-6
- V.C. Mow, and W. C. Hayes, "Basic Orthopaedic Biomechanics Second Edition," Lippincott-Raven, 1997.
- P. Helwig, C. Faust, U. Hindenlang, A. Hirschmuller, L. Konstantinidis, C. Bahrs, N. Sudkamp, and R. Schneider, "Finte element analysis of four different implants inserted in different positions to stabilize an idealized trochanteric femoral fracture," Injury, vol. 40, pp. 288-295, 2008.
- J. R. T. Jeffers, M. Browne, A. B. Lennon, P. J. Prendergast, and M. Taylor "Cement mantle fatigue in total hip replacement : Experimental and computational testing," Journal of Biomechanics, vol. 40, pp. 1525-1533, 2007. https://doi.org/10.1016/j.jbiomech.2006.07.029
- H. J. Kim, J. S. Lim, S. M. Han, J. H. You, K. W. Choi, and I. C. Yoon, "Evaluation of mechanical stability in development of customized hip implant," Jouranl of the Korean society of precision engineering, vol. 26, no. 7, pp. 1-2, 2009.
- Gudance document for the preparation of premarket notifications of ceramic ball hip systems.
- F. Higuchi, N. Shiba, A. Inoue and I. Wakebe, "Fracture of an Alumina Ceramic Head in Total Hip Arthroplasty," The Journal of Arthoplasty, vol. 10, no. 6, 1995.
- S. Y. Kim, Y. G. Kim, J. Y. Yeo, D. H. Kim, and J. C. Ihn "Ceramic-on-Ceramic Bearing Total Hip Athroplasty in Young Patients with Osteonecrosis of Femoral Head," J.of Korean Orthop. Assoc. vol. 39, pp. 233-8, 2004. https://doi.org/10.4055/jkoa.2004.39.3.233
- A, Arenas, A. Tejero, A. Garbayo, C. Arias, J. Barbadillo, and J. Lecumberri "Ceramic femoral heal fractures I total hip replacement," International Orthopaedics, vol. 23, pp. 351-352, 1999. https://doi.org/10.1007/s002640050390