• Title/Summary/Keyword: Highly plastic

Search Result 375, Processing Time 0.021 seconds

Highly Sensitive Cholesterol Sensors Using Mixture of Cholesterol Oxidase and ZnO Nanoparticles on Plastic

  • Park, Sukhyung;Cho, Kyoungah;Kim, Sangsig
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.3
    • /
    • pp.136-138
    • /
    • 2014
  • In this study, cholesterol sensors consisting of a mixture of cholesterol oxidase (ChOx) and zinc oxide (ZnO) nanoparticles (NPs) are constructed on plastic substrates and their sensing characteristics are examined in air. The current of the ChOx-ZnO NP film decreases in magnitude as cholesterol molecules are adsorbed on the film, due to the resulting increase in the number of electrons generated by the reaction between the cholesterol and the ChOx. The cholesterol sensor shows a high sensitivity of $1.08{\mu}A/mM$ and a wide detection range from 10 nM to 1 mM.

Thermal Residual Stress Relaxation Behavior of Alumina/SiC Nanocomposites (Alumina/SiC 나노복합재료에서의 잔류 열응력 완화거동에 관한 연구)

  • Choa, Y.H.;Niihara, K.;Ohji, T.;Singh, J.P.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2002.04b
    • /
    • pp.11-11
    • /
    • 2002
  • Plastic deformation was observed by TEM around the intragranular SiC particles in the $Al_2O_3$ matrix for $Al_2O_3/SiC$ nanocomposite system. The dislocations are generated at selected planes and there is a tendency for the dislocations to form a subgrain boundary structure with low-angel grain boundaries and networks. In this study, dislocation generated in the $Al_2O_3$ matrix during cooling down from sintering temperatures by the highly localized thermal stresses within and/or around SiC particles caused from the thermal expansion mismatch between $Al_2O_3$ matrix and SiC particle was observed. In monolithic $Al_2O_3$ and $Al_2O_3/SiC$ microcomposite system. These phenomena is closely related to the plastic relaxation of the elastic stress and strain energy associated with both thermal misfitting inclusions and creep behaviors. The plastic relaxation behavior was explained by combination of yield stress and internal stress.

  • PDF

Usefulness of V-Y Advancement Flap for Defects after Skin Tumor Excision

  • Kwon, Ki Hyun;Lee, Dong Gwan;Koo, Su Han;Jo, Myoung Soo;Shin, Heakyeong;Seul, Jung Hyun
    • Archives of Plastic Surgery
    • /
    • v.39 no.6
    • /
    • pp.619-625
    • /
    • 2012
  • Background After skin tumor excision on the face, extremities, or trunk, the choice of treatment for a skin defect is highly variable. Many surgeons prefer to use a local flap rather than a skin graft or free flap for small- or moderately-sized circular defects. We have used unilateral or bilateral V-Y advancement flaps, especially on the face. Here we evaluated the functional and aesthetic results of this technique. Methods All of the patients were pathologically diagnosed with squamous cell carcinoma (SCC), basal cell carcinoma (BCC), or malignant melanoma or premalignant lesion (Bowen's disease). Thirty-two patients underwent V-Y advancement flap repair (11 unilateral and 21 bilateral) from January 2007 to June 2011. We analyzed the patients' age and satisfaction, and location and size of defect. The patients were followed up for 6 months or more. Results There were 22 women and 10 men. The ages ranged from 47 to 93 years with a mean age of 66 years. The causes were SCC in 15 cases, BCC in 13 cases, malignant melanoma in 1 case, Bowen's disease in 2 cases, and another cause in 1 case. The tumor locations were the face in 28 patients, and the scalp, upper limb, and flank each in one patient. All of the flaps survived and the aesthetic results were good. Postoperative recovery was usually rapid, and no complication or tumor recurrence was observed. Conclusions The V-Y advancement flap is often used not only for facial circular defects but also for defects of the trunk and extremities. Its advantages are less scarring and superior aesthetic results as compared with other local flap methods, because of less scarification of adjacent tissue and because it is an easy surgical technique.

Transaxillary Subpectoral Placement of Cardiac Implantable Electronic Devices in Young Female Patients

  • Oh, Joo Hyun;Kim, Chae Min;Song, Seung Yong;Uhm, Jae Sun;Lew, Dae Hyun;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.44 no.1
    • /
    • pp.34-41
    • /
    • 2017
  • Background The current indications of cardiac implantable electronic devices (CIEDs) have expanded to include young patients with serious cardiac risk factors, but CIED placement has the disadvantage of involving unsightly scarring and bulging of the chest wall. A collaborative team of cardiologists and plastic surgeons developed a technique for the subpectoral placement of CIEDs in young female patients via a transaxillary approach. Methods From July 2012 to December 2015, subpectoral CIED placement via an axillary incision was performed in 10 young female patients, with a mean age of 25.9 years and mean body mass index of $20.1kg/m^2$. In the supine position, with the patient's shoulder abducted, an approximately 5-cm linear incision was made along one of the deepest axillary creases. The submuscular plane was identified at the lateral border of the pectoralis major, and the dissection continued over the clavipectoral fascia until the subpectoral pocket could securely receive a pulse generator. Slight upward dissection also exposed an entrance to the subclavian vein, allowing the cardiology team to gain access to the vein. One patient with dilated cardiomyopathy underwent augmentation mammoplasty and CIED insertion simultaneously. Results One case of late-onset device infection occurred. All patients were highly satisfied with the results and reported that they would recommend the procedure to others. Conclusions With superior aesthetic outcomes compared to conventional methods, the subpectoral placement of CIEDs via a transaxillary approach is an effective, single-incision method to hide operative scarring and minimize bulging of the device, and is particularly beneficial for young female or lean patients.

Gender Reassignment Surgery in Human Immunodeficiency Virus-Positive Patients: A Report of Two Cases

  • Kim, Seok-Kwun;Choi, Ji-An;Kim, Myung-Hoon;Kim, Min-Su;Lee, Keun-Cheol
    • Archives of Plastic Surgery
    • /
    • v.42 no.6
    • /
    • pp.776-782
    • /
    • 2015
  • It is believed that surgery on human immunodeficiency virus (HIV)-positive patients is dangerous and should be avoided due to the possibility of postoperative infection of the patients or HIV occupational transmission to the medical staff. We discuss here the preparations and measures needed to conduct surgery safely on HIV-positive patients, based on our experience. We performed sex reassignment surgery on two HIV-positive patients from January 2013 to January 2015. Both of them were receiving highly active antiretroviral therapy and were asymptomatic, with a normal CD4 count ($>500cells/{\mu}L$). The HIV-RNA was undetectable within the bloodstream. All the staff wore protective clothing, glasses, and three pairs of protective gloves in the operating room because of the possibility of transmission. Prophylactic antibiotics were administered to the patients, and antiviral therapy was performed during their perioperative course. Neither of the patients had postoperative complications, and none of the medical staff experienced accidental exposure. Both patients had satisfactory surgery outcomes without complications. HIV-positive patients can undergo surgery safely without increased risk of postoperative complications or HIV transmission to the staff through the proper use of antibiotics, active antiretroviral therapy, and supplemental protective measures with post-exposure prophylaxis for the staff in case of HIV exposure.

A Hybrid Artificial Neural Network and Genetic Algorithm based Cost Estimation Approach for Feature-based Plastic Injection Products (특징기반 플라스틱 사출제품을 위한 하이브리드 인공신경망과 유전자 알고리즘 기반의 비용 평가 방법)

  • Seo, Kwang-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.2963-2968
    • /
    • 2011
  • Plastic injection products have been widely used in various electronic appliances and high-tech commodities. However, plastic injection product manufacturers have to spare no efforts to shorten new product development period to introduce new products into the market ahead of other competitors, gaining competitiveness and satisfying customers. The manufacturers cannot only get big target market share rapidly but also the advantage of leading the product price in order to survive in highly competitive market. This paper proposes the cost estimation approach of feature-based plastic injection products by using hybrid artificial neural network and genetic algorithm. The proposed method is to dramatically simplify and shorten the complex conventional cost estimation procedures and the requested computation parameters of plastic injection products. The case study demonstrates the efficiency and effectiveness of the proposed model in solving the cost estimation problem of plastic injection products at the development stage.

Photogrammetry Based on Standardized Clinical Photography using Cephalostat: Comparison with Anthropometric Analysis (머리고정기(Cephalostat)를 이용한 표준임상사진술에서 사진계측법: 인체계측법과의 비교)

  • Kwon, Hyuk Joon;Han, Ki Hwan;Kim, Jun Hyung;Son, Dae Gu
    • Archives of Plastic Surgery
    • /
    • v.34 no.1
    • /
    • pp.24-36
    • /
    • 2007
  • Purpose: Direct anthropometry is an ideal method for preoperative planning and postoperative evaluation in plastic surgery, but it requires highly skilled specialty. Indirect anthropometry, especially photogrammetry, is an alternative method. In photogrammetry, standardized clinical photography is essential. Photogrammetry-based standardized clinical photography has several advantages over direct anthropometry. It is easier to measure and has less chance to make errors during measurement. Furthermore, it is possible to repeat measurements, and available for follow up study based on permanent custody. But, it is still different from actual measurement, and inherently less accurate than anthropometry. Methods: The authors revised the standardized clinical photography and then, carried out photogrammetry using Photoshop(Adobe, U.S.A.), and compared each data with those of anthropometry. The subjects were 50 males and 50 females, undergraduate medical students in twenties. Standard head position was obtained from the wire, fixed to cephalostat which indicates the Frankfort horizontal plane. All photographs were taken at the same situation such as fixed position of light, subject and camera, etc. Results: Total 96 measurements, based on 40 landmarks, consist of linear measurements, angular measurements and inclinations include 3 measurements in head, 22 in face, 15 in orbit, 28 in nose, 16 in lip and mouth, and 12 in ear. Conclusion: Normal photogrammetric data of face of Korean in twenties was obtained. Reliable photogrammetric measurements, not significantly different from anthropometric measurement statistically, accounted for 44 in 96 measurements(45.8%). Anthropometric values different from those of photogrammetric values were obtained by multiplying coefficient by photogrammetric value.

Watch One, Do One? A Systematic Review and Educational Analysis of YouTube Microsurgery Videos, and a Proposal for a Quality Assurance Checklist

  • Fernandez-Diaz, Oscar F.;Navia, Alfonso;Berner, Juan Enrique;Ahmad, Fateh;Guerra, Claudio;Ragbir, Maniram
    • Archives of Plastic Surgery
    • /
    • v.49 no.5
    • /
    • pp.668-675
    • /
    • 2022
  • Background Educational resources on the internet are extensively used to obtainmedical information. YouTube is the most accessed video platform containing information to enhance the learning experience of medical professionals. This study systematically analyzed the educational value of microsurgery-related videos on this platform. Methods A systematic review was conducted on YouTube from April 18 to May 18, 2020, using the following terms: "microsurgery," "microsurgical," "microsurgical anastomosis," "free flap," and "free tissue transfer." The search was limited to the first 100 videos, and two independent reviewers screened for eligible entries and analyzed their educational value using validated scales, including a modified version of the DISCERN score (M-DISCERN), Journal of the American Medical Association (JAMAS) benchmark criteria, and the Global Quality Score (GQS). Evaluation of video popularity was also assessed with the video power index (VPI). Results Of 356 retrieved videos, 75 (21%) were considered eligible. The educational quality of videos was highly variable, and the mean global scores for the M-DISCERN, JAMAS, and GQS for our sample were consistent with medium to low quality. Conclusions A limited number of videos on YouTube for microsurgical education have high-educational quality. The majority scored low on the utilized criteria. Peer-reviewed resources seem to be a more reliable resource. Although the potential of YouTube should not be disregarded, videos should be carefully appraised before being usedas an educational resource.

Lipoinjection with Adipose Stem Cells for Nasal Modeling: Rhino Cell, a Highly Versatile Alternative

  • Yanko Castro-Govea;Jorge A. Garcia-Garza;Sergio E. Vazquez-Lara;Cynthia M. Gonzalez-Cantu;Hernan Chacon-Moreno;Víctor H. Cervantes-Kardasch
    • Archives of Plastic Surgery
    • /
    • v.50 no.4
    • /
    • pp.335-339
    • /
    • 2023
  • It is undeniable that a significant number of patients who want to improve their facial appearance is increasingly interested in nonsurgical procedures. Without a doubt, the use of autologous fat could not be left out as a magnificent alternative for nasal modeling simply because of four influential factors: ease of collection, compatibility, the temporality of the results, and safety. This work describes an innovative alternative technique for nasal modeling using micrografts enriched with adipose-derived mesenchymal stem cells (ASCs). With this technique, fat was collected and divided into two samples, nanofat and microfat. Nanofat was used to isolate the ASCs; microfat was enriched with ASCs and used for nasal modeling. Lipoinjection was performed in a supraperiosteal plane on the nasal dorsum. Through a retrolabial access, the nasal tip and base of the columella were lipoinjected. We consider that nonsurgical nasal modeling using micrografts enriched with ASCs can be an attractive and innovative alternative. This technique will never be a substitute for surgical rhinoplasty. It can be performed in a minor procedure area with rapid recovery and return to the patient's daily activities the next day. If necessary, the procedure can be repeated.

Microarray Analysis of Extracranial Arteriovenous Malformation Endothelial Cells

  • Lee, Joon Seok;Oh, Eun Jung;Kim, Hyun Mi;Kwak, Suin;Lee, Seok-Jong;Lee, Jongmin;Huh, Seung;Kim, Ji Yoon;Chung, Ho Yun
    • Journal of Interdisciplinary Genomics
    • /
    • v.4 no.2
    • /
    • pp.31-34
    • /
    • 2022
  • Background: Arteriovenous malformations (AVMs) are rare diseases comprising abnormally dilated arteries and veins with an absence of a capillary network. Since these diseases are intractable after diagnosis, various treatment strategies have been examined, with continuous efforts to identify target genes. Here, we report relevant new target genes selected via gene microarray. Methods: Endothelial cells were isolated from samples collected from three patients with AVM and three healthy individuals, followed by microarray analysis. Additionally, quantitative PCR was performed to select genes highly relevant to AVM. Results: In the vascular endothelial cells derived from the tissues of patients with AVM, the expression of ANGPT1, ANGPT2, DLL4, IL6, NRG1, TGFBR1, and VEGFA was typically higher compared to those derived from normal tissues. Conclusion: Seven candidate genes were selected to analyze the pathophysiological mechanism of AVM. These results may aid in future directions of diagnosis and treatment.