Calculation of Outdoor Air Fraction through Economizer Control Types during Intermediate Season

  • Hong, Goopyo;Hong, Jun;Kim, Byungseon Sean
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose: In this study, we examined outdoor air fraction using historical data of actual Air Handling Unit (AHU) in the existing building during intermediate season and analyzed optimal outdoor air fraction by control types for economizer. Method: Control types for economizer which was used in analysis are No Economizer(NE), Differential Dry-bulb Temperature(DT), Diffrential Enthalpy(DE), Differential Dry-bulb Temperature+Differential Enthalpy(DTDE), and Differential Enthalpy+Differential Dry-bulb Temperature (DEDT). In addition, the system heating and cooling load were analyzed by calculating the outdoor air fraction through existing AHU operating method and control types for economizer. Result: Optimized outdoor air fraction through control types was the lowest in March and distribution over 50% was shown in May. In case of DE control type, outdoor air fraction was the highest of other control types and the value was average 63% in May. System heating load was shown the lowest value in NE, however, system cooling load was shown 1.7 times higher than DT control type and 5 times higher than DE control type. For system heating load, DT and DTDE is similar during intermediate season. However, system cooling load was shown 3 times higher than DE and DEDT. Accordingly, it was found as the method to save cooling energy most efficiently with DE control considering enthalpy of outdoor air and return air in intermediate season.

왕겨 및 왕겨재의 화학적 조성 성분과 열적 특성 (Chemical Compositions and Thermal Characteristics of Rice Husk and Rice Husk Ash in Korea)

  • 박승제;김명호;신현명
    • Journal of Biosystems Engineering
    • /
    • 제30권4호
    • /
    • pp.235-241
    • /
    • 2005
  • For better and large utilization of rice husk, the production and consumption status, differences in chemical composition and heating value due to region and variety, and thermogravimetric characteristic of rice husk were studied. In addition, the differences in chemical composition due to region and variety and the crystallization characteristic of rice husk ash were also studied. Approximately 800,000 M/T of rice husk was produced per year in Korea, which is about $18\%$ of the paddy production by weight. Noticeable varietal and regional difference pattern in chemical composition was not found among the domestic rice husk samples. Their average ash content and higher heating value were $16.4\%$ and 16,660 kJ/kg by dry basis, respectively. A relation seemed to exist between the carbon content and higher heating value. Noticeable difference pattern in chemical composition was not found among the domestic rice husk ash samples. The $SiO_2$ contents were a little low, the maximum being $92.9\%,$ and the contents of major components such as CaO, MgO, and $K_2O$ were also lower compared with foreign rice husk ash due to the deficiency of compost matters in domestic soils. Thermogravimetry study showed the thermal decomposition of rice husk started at about $250^{\circ}C,$ followed by relatively fast combustion of combustible gas until the temperature rose to $350^{\circ}C.$ After $350^{\circ}C,$ combustion of the carbon component proceeded relatively slowly as the temperature increased. Therefore, the ignition temperature of the rice husk could be estimated around $300^{\circ}C$. Crystallization of $SiO_2$ in the rice husk ash was found from the combustion temperature of $750^{\circ}C$ and became distinctly when the combustion temperature exceeded $900^{\circ}C$. The ash became darker with $SiO_2$ crystallization.

알칼리 정제(精製)와 에스테르화에 의한 미강유의 열안정성(熱安定性)의 비교(比較) (Comparison of Thermal Stability of Alkali Refined and Esterified Rice Bran Oils)

  • 김현구;신동화;신효선
    • 한국식품과학회지
    • /
    • 제17권3호
    • /
    • pp.180-185
    • /
    • 1985
  • 알칼리 처리와 글리세린으로 에스테르화 반응을 시킨 탈산공정에 의하여 정제한 각 미강유의 열안정성을 비교하였다. 가열중 산 값의 변화는 알칼리정제 미강유에서는 가열시간에 따라서 증가하였으나, 글리세린처리 미강유의 일부는 완만한 증가추세를, 또 일부는 가열시간이 경과함에 따라서 산 값이 감소하였다. 과산화물 값의 변화는 가열중 증가와 감소의 반복추세를 나타냈으며 알칼리 정제 미강유와 글리세린처리 미강유의 과산화물 값이 13.3 mgq/kg하였다. TBA값의 변화는 가열 10시간까지 급격하게 증가하고 그후 완만한 감소추세를 나타낸다. 가열중 글리세린처리 미강유는 착색현상이 심하였다. 알칼리정제 미강유와 글리세린 미강유의 90시간 가열 후 TG의 감소율은 $150^{\circ}C$에서는 처리방법에 따라 큰 차이가 없었으나, $150^{\circ}C$에서는 글리세린처리미강유가 알칼리정제 미강유보다 TC의 감소율이 약 2${\sim}$7% 높았다. AOM 시험에서 알칼리 정제미강유는 글리세린처리미강유보다 약 2배의 산화 안정성이 있었다.

  • PDF

초음파 개질 경유의 점도 및 표면장력 측정을 이용한 발열량 직접 계산 (A Direct Calculation of Higher Heating Values of Ultrasonic Reformed Diesel Fuels by Using Their Viscosity and Surface Tension Measurements)

  • 이병오;류정인
    • 한국분무공학회지
    • /
    • 제6권4호
    • /
    • pp.22-30
    • /
    • 2001
  • The objective of this study is to develop the new equations for the calculation of higher heating values(HHVs) of reformed diesel fuels by ultrasonic treatment. Therefore, higher heating values of reformed diesel fuels by ultrasonic treatment are determined experimentally and calculated from their viscosity and surface tension measurements. The HHVs of the fuels are supposed to be a function of viscosity(Pa s) and surface tension(N/cm). The equations developed for the samples represent the correlation obtained by means of regression analysis. The HHVs calculated by developing new equations using viscosities showes the differences from the measured values ranging from -0.66 to 1.19 % and the correlation coefficient was -0.9411. The HHVs calculated by developing new equations using surface tensions showed the differences from the measured values ranging from -0.70 to 1.51 % and the correlation coefficient was 0.9999. The viscosity and the surface tension are characteristic properties of ultrasonic reformed diesel fuels for developing new formulae.

  • PDF

원소분석을 통한 바이오매스에 도시형 유기성 폐기물을 혼합한 신연료의 고위발열량 예측 (Estimating the Higher Heating Value of Eco-fuel mixed Biomass with Municipal Organic Wastes from Ultimate Analysis Data)

  • 오송열;김래현;한희준;문장수;김희준
    • 에너지공학
    • /
    • 제16권4호
    • /
    • pp.194-201
    • /
    • 2007
  • 바이오매스계 연료의 고위발열량(HHV) 예측을 성분원소분석 데이터와 제안된 대표적인 상관관계식을 이용하여 수행하였고, 각 상관식에 대한 그 타당성을 실측 HHV와 비교하여 검토하였다. 실험에 사용된 샘플들은 산림계 바이오매스인 노송나무의 톱밥과, 농업계 바이오매스인 왕겨, 그리고 여기에 유기성 폐기물인 polystyrene, waste paper, polypropylene을 각각 10, 30, 50wt%로 혼합하여 제작하였다. 성분원소의 측정과 HHV의 측정은 각각 KS 표준방법에 따랐으며, 예측된 HHV값의 평균 오차는 약 880 kJ/kg으로 이는 측정된 HHV의 약 3.8%에 해당하였다. 실험을 통한 값과 예측된 HHV 값 사이의 대응 상관계수의 곱($R^2$)은 $0.957{\sim}0.996$의 값을 나타내었다.

지중가온이 온실의 난방부하에 미치는 영향 (The Effect of Soil Warming on the Greenhouse Heating Load)

  • 남상운
    • 한국농공학회논문집
    • /
    • 제48권5호
    • /
    • pp.51-60
    • /
    • 2006
  • In order to examine the heat transfer characteristic of a soil warming system and effects of soil warming on the greenhouse heating load, control experiments were performed in two greenhouses covered with double polyethylene film. One treated the soil warming with an electric heat wire and the other treated a control. Inside and outside air temperature, soil temperature and heat flux, and heating energy consumption were measured under the set point of heating temperature of $5,\;10,\;15,\;and\;20^{\circ}C$, respectively. Soil temperatures in a soil warming treatment were observed $4.1\;to\;4.9^{\circ}C$ higher than a control. Heating energy consumptions decreased by 14.6 to 30.8% in a soil warming treatment. As the set point of heating temperature became lower, the rate of decrease in the heating energy consumptions increased. The percentage of soil heat flux in total heating load was -49.4 to 24.4% and as the set point of heating temperature became higher, the percentage increased. When the set point of heating temperature was low in a soil warming treatment, the soil heat flux load was minus value and it had an effect on reducing the heating load. Soil heat flux loads showed in proportion to the air temperature difference between the inside and outside of greenhouse but they showed big difference according to the soil warming treatment. So new model for estimation of the soil heat flux load should be introduced. Convective heat transfer coefficients were in proportion to the 1/3 power of temperature difference between the soil surface and the inside air. They were $3.41\;to\;12.42\;W/m^{2}^{\circ}C$ in their temperature difference of $0\;to\;10^{\circ}C$. Radiative heat loss from soil surface in greenhouse was about 66 to 130% of total heating load. To cut the radiation loss by the use of thermal curtains must be able to contribute for the energy saving in greenhouse.

돈지와 대두유를 이용한 바이오디젤 제조에서 메탄올과 에탄올의 혼합효과 (The Mixing Effect of Methanol and Ethanol in Lard and Soybean Oil Based Biodiesel Production)

  • 이승범;김형진
    • 공업화학
    • /
    • 제25권5호
    • /
    • pp.515-519
    • /
    • 2014
  • 대두유와 돈지를 이용한 에스테르교환반응실험에서 메탄올과 에탄올의 혼합비율을 조절하여 제조된 바이오디젤의 연료특성을 평가하였다. 메탄올보다는 에탄올에 대한 유지의 용해도가 높았으며 에탄올의 몰비가 증가함에 따라 균질한 바이오디젤 제조가 가능함을 확인하였다. 반응온도 $60^{\circ}C$에서 메탄올과 에탄올의 혼합몰비가 6 : 6일 때 돈지의 경우 가장 우수한 바이오디젤 전환특성을 나타내었다. 또한 대두유의 경우 3 : 3일 때 가장 우수한 바이오디젤 전환특성을 나타내었다. 대두유와 돈지를 원료로 하여 제조된 바이오디젤의 동점도는 $40^{\circ}C$에서 각각 4.17~4.35 cSt, 4.69~4.93 cSt로 측정되었으며, 에탄올의 첨가비가 증가함에 따라 산화안정성과 고위발열량은 증가하였다. 산화안정성은 바이오디젤의 품질기준인 6 h 이상을 만족하였고, 고위발열량은 약 40 MJ/kg으로 나타났다.

경량전철 시스템 선로 결빙방지에 관한 연구 (A study on the anti-freezing of light weight electric traction system testing road)

  • 우재호;한규일;김종수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2256-2261
    • /
    • 2008
  • The electric snow melting and deicing system by electric heating cable which is adopted in this study is a part of road facilities to keep surface temperature of the road higher than freezing point of water for melting the snow or ice accumulated on it. The electric heating cables are buried under paved road at a certain depth and a certain pitch and operated automatically and manually. Design theory, amount of heating, and installation standard vary according to economic situation, weather condition, and installation place. A main purpose of this study is figuring out the appropriate range of required heat capacity and installation depth and pitches for solving snowdrifts and freezing problems with minimum electric power consumption. This study was performed under the ambient air temperature($-2^{\circ}C$, $-5^{\circ}C$), the pitches of the electric heating cables (200 mm, 300 mm), heating value ($250\;W/m^2$, $300\;W/m^2$, $350\;W/m^2$).

  • PDF

오스테나이트계 스테인레스강의 마찰압접시 압접조직과 열적거동에 관한 연구 (A study on welding structure and thermal behavior in friction welding of austenitic stainless steel)

  • 강춘식;정태용
    • Journal of Welding and Joining
    • /
    • 제8권1호
    • /
    • pp.43-53
    • /
    • 1990
  • The transient temperature distribution in the continuous friction welding 304 stainless steel bars is investigated by experimental and analytical methods. It is calculated by F.D.M. (finite difference method). The heating pressure, the rotational speed and friction coefficient obtained from experiment are used to determine the heat input at the contacting surface. Thermal properties of the workpiece are the function of temperature. The calculated temperature is well coincided with the measured value. The grain size at weld interface is extremely small due to the severe plastic deformation at high temperature, and result of this refined zone reveals higher hardness value. Because the HAZ is very narror about 2-3 mm, welding defects do not occure.

  • PDF

공동주택의 관리비 추정모델 연구 (A Study on the Maintenance Cost Estimation Model of the Apartment Housing)

  • 이강희;양재혁;채창우
    • 한국주거학회논문집
    • /
    • 제21권2호
    • /
    • pp.59-67
    • /
    • 2010
  • The maintenance cost plays a important role to plan the scale of the apartment housing such as a number of household, building area and building type. Therefore, it is required to forecast the cost considering various maintenance characteristics. The maintenance characteristics are floor area, number of household, heating type, site area and etc.. In addition, the maintenance cost are classified into 5 area. These are a personal expense, facility maintenance cost, energy and water cost, insurance and sanitary cost. These five cost area are related with various characteristics and brought up the estimation model using the stepwise multiple regression analysis. The energy and heating cost share over the 50% in the total cost and the personal expense cost shares about 40%. The personal expense cost per area is 5,272 won/$m^2{\cdot}yr$ irregardless of heating type and the district heating type is a higher cost than other type. In facility maintenance cost, the central heating type is 2,015 won/$m^2{\cdot}yr$ and higher than other type. The estimation models have good statistics in each model. Most of the model have a determination coefficient over 0.7 and Durbin Watson value between 1.5 and 2.5.