• Title/Summary/Keyword: Higher Concentration

Search Result 14,137, Processing Time 0.045 seconds

[ $Gd(DTPA)^{2-}$ ]-enhanced, and Quantitative MR Imaging in Articular Cartilage (관절연골의 $Gd(DTPA)^{2-}$-조영증강 및 정량적 자기공명영상에 대한 실험적 연구)

  • Eun Choong-Ki;Lee Yeong-Joon;Park Auh-Whan;Park Yeong-Mi;Bae Jae-Ik;Ryu Ji Hwa;Baik Dae-Il;Jung Soo-Jin;Lee Seon-Joo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.100-108
    • /
    • 2004
  • Purpose : Early degeneration of articular cartilage is accompanied by a loss of glycosaminoglycan (GAG) and the consequent change of the integrity. The purpose of this study was to biochemically quantify the loss of GAG, and to evaluate the $Gd(DTPA)^{2-}$-enhanced, and T1, T2, rho relaxation map for detection of the early degeneration of cartilage. Materials and Methods : A cartilage-bone block in size of $8mm\;\times\;10mm$ was acquired from the patella in each of three pigs. Quantitative analysis of GAG of cartilage was performed at spectrophotometry by use of dimethylmethylene blue. Each of cartilage blocks was cultured in one of three different media: two different culture media (0.2 mg/ml trypsin solution, 1mM Gd $(DTPA)^{2-}$ mixed trypsin solution) and the control media (phosphate buffered saline (PBS)). The cartilage blocks were cultured for 5 hrs, during which MR images of the blocks were obtained at one hour interval (0 hr, 1 hr, 2 hr, 3 hr, 4 hr, 5 hr). And then, additional culture was done for 24 hrs and 48 hrs. Both T1-weighted image (TR/TE, 450/22 ms), and mixed-echo sequence (TR/TE, 760/21-168ms; 8 echoes) were obtained at all times using field of view 50 mm, slice thickness 2 mm, and matrix $256\times512$. The MRI data were analyzed with pixel-by-pixel comparisons. The cultured cartilage-bone blocks were microscopically observed using hematoxylin & eosin, toluidine blue, alcian blue, and trichrome stains. Results : At quantitation analysis, GAG concentration in the culture solutions was proportional to the culture durations. The T1-signal of the cartilage-bone block cultured in the $Gd(DTPA)^{2-}$ mixed solution was significantly higher ($42\%$ in average, p<0.05) than that of the cartilage-bone block cultured in the trypsin solution alone. The T1, T2, rho relaxation times of cultured tissue were not significantly correlated with culture duration (p>0.05). However the focal increase in T1 relaxation time at superficial and transitional layers of cartilage was seen in $Gd(DTPA)^{2-}$ mixed culture. Toluidine blue and alcian blue stains revealed multiple defects in whole thickness of the cartilage cultured in trypsin media. Conclusion : The quantitative analysis showed gradual loss of GAG proportional to the culture duration. Microimagings of cartilage with $Gd(DTPA)^{2-}$-enhancement, relaxation maps were available by pixel size of $97.9\times195\;{\mu}m$. Loss of GAG over time better demonstrated with $Gd(DTPA)^{2-}$-enhanced images than with T1, T2, rho relaxation maps. Therefore $Gd(DTPA)^{2-}$-enhanced T1-weighted image is superior for detection of early degeneration of cartilage.

  • PDF

The relationships between lead exposure indicies and urinary δ-ALA by HPLC and colorimetric method in lead exposure workers (연노출근로자에 있어서 흡광광도법과 HPLC법에 의한 요중 δ-ALA 배설량과 연노출지표들 간의 관련성)

  • Ahn, Kyu-Dong;Lee, Sung-Soo;Hwangbo, Young;Lee, Gab-Soo;Yeon, You-Yong;Kim, Yong-Bae;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.77-87
    • /
    • 1996
  • In order to compare the difference of the measurement of delta aminolevulinic acid(${\delta}$-ALA) in urine between HPLC method(HALA) and colorimetric method(CALA), and also to provide useful information for the new diagnostic criteria of ${\delta}$-ALA in urine in lead poisoning, if at all possible in the future, authors studied 234 male lead workers who were selected from 7 storage battery factories, 3 secondary smelting industries, and 2 litharge making industries. Study subjects were selected on the basis of blood Zinc protoporphyrin(ZPP) level from low to high concentration to cover wide range of lead exposure. Study variables for this study were ${\delta}$-ALA measured by two different methods, blood lead(PbB), and blood ZPP. The results were as follows: 1. There was very high correlation between ${\delta}$-ALA measured by two method(r = 0.989 : HALA = -0.8194 + 0.8110 ${\times}$ CALA), but the value of CALA was measured about 2mg/L greater than HALA. 2. While the correlations of ${\delta}$-ALA by two method with blood lead and blood ZPP were 0.46 and 0.37 respectively, they were increased to 0.63 and 0.57 if ${\delta}$-ALA values were log-transformed. 3. Simple linear regression of ${\delta}$-ALA measured by two method on ZPP were as follows: CALA = 2.0421 + 0.0341 ${\times}$ ZPP ($R^2=0.1385$ p = 0.0001) HALA = 0.8006 + 0.0280 ${\times}$ ZPP ($R^2=0.1389$ p = 0.0001) 4. Simple linear regression of ${\delta}$-ALA measured by two method on PbB were as follows: CALA = - 0.4134 + 0.1545 ${\times}$ PbB ($R^2=0.2085$ p = 0.0001) HALA = -1.2893 + 0.1287 PbB ($R^2=0.2154$ p = 0.0001), 5. Simple linear regression of log-transformed ${\delta}$-ALA by two method on ZPP and PbB were as follows: logHALA = 0.3078 + 0.0060 ZPP ($R^2=0.3329$ p = 0.0001) logCALA = 1.0189 + 0.0044 ZPP ($R^2=0.3290$ p = 0.0001) logHALA = -0.0221 + 0.0246 PbB ($R^2=0.4046$ p = 0.0001) logCALA = 0.7662 + 0.0184 PbB ($R^2=0.4108$ p = 0.0001) 6. The cumulative percent of colorimetric method to detect lead workers whose value of PbS and ZPP were over screening level such as $40{\mu}/dl$ and $100{\mu}/dl$ respectively was higher than HPLC method if cut-off level of ${\delta}$-ALA for screening of lead poisoning was 5 mg/L. But if cut-off level of ${\delta}$-ALA measured by HPLC was reduced to 3 mg/L which is compatible to 5 mg/L of ${\delta}$-ALA measured by colorimetric method, there were good agreement between two methods and showed dose-response relationship with other lead exposure indices such as PbB and ZPP.

  • PDF

Factors Related to Serum Level of Carbohydrate Antigen 19-9 and Cancer Antigen 125 in Healthy Rural Populations in Korea (일부 농촌지역 주민에서 혈청 CA19-9 및 CA125 농도에 영향을 미치는 인자에 관한 연구)

  • Lee, SK;Yoo, KY;Park, SK;Kang, DH;Kim, JQ;Chung, JK;Lee, MC
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.71-80
    • /
    • 1998
  • This study examines the levels of carbohydrate antigen 19-9(CA19-9) and cancer antigen 125(CA125) in serum and its related factors in healthy Korean population. Although CA19-9 and CA125 have been widely used tumor markers for gastroenteric cancers and ovarian cancer in Western countries, there are no information available on the serum levels of CA19-9 and CA125 in healthy population and the factors affecting the levels of these tumor markers in Korea. A cross-sectional study was performed to measure CA19-9 and CA125 among 76 healthy males and 95 healthy females in Korea. CA19-9 and CA125 were quantitated using solid-phase radioimmunoassay kits. Informations on the factors which might be related to the levels of these markers were collected by questionnaire(e.g., smoking, alcohol consumption, menstruation, oral pill use, breast-feeding history, etc.). There was no statistically significant difference in the mean of CA19-9 concentration between men(10.4 u/ml) and women(10.1 u/ml), whereas the mean of CA125 levels(11.2 u/ml) was higher in women than that(2.5 u/ml) in men. Although there was a statistically significant association between CA19-9 and average number of cigarette consumed per day(r=0.59, p=0.026) and total number of cigarettes consumed in women(r=0.74, p=0.003), the significance disappeared by multiple regression analysis after adjusting age and body mass index. Later age of menopause(p=0.035) and longer duration of breast-feeding(p=0.050) were significant predictors for CA125 levels in women by multiple regression analysis after adjusting age and body mass index. In conclusion, CA19-9 can be used as a stable tumor marker in clinical practices, however, menstruation and breast-feeding should be considered when CA125 is used in women.

  • PDF

Chemical Characteristics of Ground Water for Hydroponics and Waste Nutrient Solution after Hydroponics in Chungbuk Area (충북지역 양액 재배용 지하수 및 폐양액의 화학적 특징)

  • Lee, Gyeong-Ja;Kang, Bo-Goo;Lee, Ki-Yeol;Yun, Tae;Park, Seong-Gyu;Lee, Cheol-Hee
    • Korean Journal of Environmental Agriculture
    • /
    • v.26 no.1
    • /
    • pp.42-48
    • /
    • 2007
  • This survey has been conducted to obtain basic data of the quality of ground water for hydroponics and waste nutrient solution after hydroponics in hydroponic farms in Chungbuk area. Ground water samples were collected and analyzed at 19 sites of hydroponic farms. Waste nutrient solution samples were analyzed at 15 sites selected of them. The values of several components in ground water for hydroponics were as follows. pH range was shown from 6.2 to 7.7 and the average was 6.8. EC range was shown from 0.10 to 0.45 dS $m^{-1}$ and the average 0.23 dS $m^{-1}$. $NO_3-N$ concentrations was ranged from 0.12 to 13.77 mg $L^{-1}$, $SO_4^{2-}$ concentrations was ranged from 1.84 to 63.01 mg $L^{-1}$ and $Cl^-$ concentrations were ranged from 10.46 to 72.09 mg $L^{-1}$. Average values of $NO_3-N$, $SO_4^{2-}$ and $Cl^-$ were 4.00 mg $L^{-1}$, 12.70 mg $L^{-1}$ and 27.57 mg $L^{-1}$, respectively. $Ca^{2+}$, $Mg^{2+}$ and $Na^+$ concentrations were ranged from 3.24 to 36.99 mg $L^{-1}$, 1.44 to 14.93 mg $L^{-1}$ and 6.12 to 25.25 mg $L^{-1}$, respectively. Average concentrations were 13.06 mg $L^{-1}$ in $Ca^{2+}$, 6.02 mg $L^{-1}$ $Mg^{2+}$ and 12.08 mg $L^{-1}$ in $Na^+$. In waste nutrient solution after hydroponics, pH range was shown from 4.3 to 8.8 and the average was 6.7. EC range was shown from 0.44 to 2.37 dS $m^{-1}$ and the average 1.15 dS $m^{-1}$. Range of $NO_3-N$, $PO_4-P$, $K^+$, $Ca^{2+}$, $Mg^{2+}$ and $Na^+$ in waste nutrient solution were $10{\sim}212$, $0.56{\sim}26.1$, $10{\sim}295$, $16{\sim}215$, $9{\sim}54$ and $10{\sim}53$ mg $L^{-1}$ respectively. Average concentration were 100 mg $L^{-1}$ in $NO_3-N$, 12.15 mg $L^{-1}$ in $PO_4-P$, 99 mg $L^{-1}$ in $K^+$, 78 mg $L^{-1}$ in $Ca^{2+}$, 26 mg $L^{-1}$ in $Mg^{2+}$ and 26 mg $L^{-1}$ in $Na^+$. Inorganic matters in waste nutrient solution after hydroponics was higher than that of ground water for hydroponics.

Evaluation of the Parameters of Soil Potassium Supplying Power for Predicting Yield Response, K2O Uptake and Optiumum K2O Application Levels in Paddy Soils (수도(水稻)의 가리시비반응(加里施肥反応)과 시비량추정(施肥量推定)을 위한 가리공급력(加里供給力) 측정방법(測定方法) 평가(評価) -I. Q/I 관계(関係)에 의(依)한 가리(加里) 공급력측정(供給力測定)과 시비반응(施肥反応))

  • Park, Yang-Ho;An, Soo-Bong;Park, Chon-Suh
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.16 no.1
    • /
    • pp.42-49
    • /
    • 1983
  • In order to find out the possibility of predicting fertilizer K requirement from the K supplying capacity of soil, the relative K activity ratio, Kas/kai, the potential buffering capacity of $K^+$ ($PBC^k$ ; the liner regression coefficient) and its activity ratio ($AR^k_o$ ; $^{k+}$/${\sqrt{Ca^{+2}+Mg^{+2}}}$ in mol/l) at ${\delta}K$ = O, in the Q/I relationships of Beckett(1964), were determined for the soils before flooding and the samples taken at heading stage of transplanted rice in pot experiment. These parameters assumed as the K supplying capacity of soils were subjected for the investigation through correlation stady between themselves and other factors such as grain yield or the amounts of $K_2O$ uptake by rice plant at harvest. The results may be summarized as follows; 1. The potassium supplying power of the flooded soil was considered to be ruled by the amounts of exchangeable K before flooding, since there was little change in exchangeable K concentration from no-exchangeable K during the incubation periods of 67 days. 2. The $PBC^k$ values, in soils before flooding were 0.027, 0.014 and 0.009, where as the $AR^k_o{\times}10^{-3}$ values were 9.1, 7.6, and 15.4, respectively, in clay, loamy and sandy loam soils. 3. The $PBC^k$ values, determined in the soil samples taken at heading stage, varied little compared with the values of orignal soil, regardless of those different fertilizer treatments and textures, showing the possibility of using them as a factor for the improvement of soil to increase the efficiency of fertilizer K. 4. The significant yield responses to potassium fertilizer application were observed wherever the $AR^k_o$ values in soil at heading stage drop down to the original $AR^k_o$ values, regardless of any levels of fertilizer application. 5. The higher correlations between the gain yield or the amounts of $K_2O$ uptake and by the use of both soil factors of $PBC^k$ and $AR^k_o$ at heading stage were observed compared with the use of any single factor. 6. The Kas/Kai value in the soil, estimated prior to the experiment, had high possitive correlation with the $AR^k_o$ determined in the soil at heading stage and could be used as a soil factor for predicting potassium fertilizer requirement.

  • PDF

Effect of Sulfur Dioxide Gas and Abscisic Acid Pretreatment on Physiological Susceptibility and Growth Damages of Coniferous Seedlings (아황산(亞黃酸)가스 및 ABA 전처리(前處理)가 침엽수(針葉樹) 유묘(幼苗)의 생장피해(生長被害)와 생리적(生理的) 감수성(感受性)에 미치는 영향(影響))

  • Lee, Im Kyun;Kim, Young Chai
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.3
    • /
    • pp.331-343
    • /
    • 1994
  • This study was conducted to find out the effect of $SO_2$ gas on growth of tree species and the effect of pretreatment of ABA to Pinus koraiensis. Abies holophylla and Taeus cuspidata on the susceptibility for $SO_2$ gas damage. The survey was carried out on the water contents of leaf and shoot, and the acidities of bark and leaf, and the chlorophyll and water soluble sulfur contents, and the changes of transpiration rates on selected seedlings exposed to $SO_2$ gas at seven levels : 0ppm, 0.5ppm, 1ppm, 2ppm, 4ppm, 26.4ppm ABA, 56.8ppm ABA. The results obtained from this research are as follows : 1. The water contents of leaf and shoot of the three tree species decreased with increasing concentrations of $SO_2$ gas and the relative susceptibility of Abies holophylla was larger than those of Taxus cuspidata and Pinus koraiensis because moisture diminution rates were higher in leaves and shoots of Abies holophylla than those of other species. 2. The acidities of bark and leaf of the three tree species increased with increasing concentrations of $SO_2$ gas. The relative susceptibility of Pinus koraiensis in bark acidity was larger than those of Abies holopfaylla and Toxus cuspidata. Abies holophylla was more susceptive than Pinus koraiensis and Taxus cuspidata. 3. Water soluble sulfur contents of the three tree species increased with increasing concentration of $SO_2$ gas. The relative susceptibility of Taxus cuspidata in water soluble sulfur contents was lager than those of Pinus koraiensis and Abies holophylla. 4. Leaf chlorophyll contents of the three tree species decreased with increasing concentrations of $SO_2$ gas. The order of the relative susceptibility in leaf chlorophyll contents was Taxus cuspidata, Abies holophylla and Pinus koraiensis. 5. Correlation coefficients among the measurement were highly significant for $SO_2$ treatment in all three tree species. 6. The transpiration rates of Abies holophylla and Taxus cuspidata did not change until up to 220 minutes after initiation of $SO_2$ gas fumigation, and changed a little during the time between 220 minutes and 270 minutes. On the other hand, Pinus koraiensis continued to change in transpiration rates little by little from the start of $SO_2$ gas treatment up to 270 minutes, meaning that Pinus koraiensis is less sensitive to ABA. 7. When 2ppm of $SO_2$ was treated. ABA pretreatment effect was detected on the six measurement parameters. ABA affected the resistance of plants by inducing stomata closure. 8. The order of relative susceptibility of the three tree species to $SO_2$ gas fumigation was Abies holophylla, Taxus cuspidata and Pinus koraiensis. Pinus koraiensis was more resistant to $SO_2$ gas than Abies holophylla and Taxus cuspidata.

  • PDF

Studies for Antibiotic Free Chicken Production Using Water Extracts from Artemisia capillaris and Camellia sinensis (인진쑥 및 녹차 추출물을 이용한 무항생제 닭고기 생산 연구)

  • Kim, Dong-Wook;Kim, Ji-Hyuk;Kang, Geun-Ho;Kang, Hwan-Ku;Park, Sung-Bok;Park, Jae-Hong;Bang, Han-Tae;Kim, Min-Ji;Na, Jae-Cheon;Chae, Hyun-Suk;Choi, Hee-Chul;Suh, Ok-Suk;Kim, Sang-Ho;Kang, Chang-Won
    • Food Science of Animal Resources
    • /
    • v.30 no.6
    • /
    • pp.975-988
    • /
    • 2010
  • Two experiments were conducted to determine whether water extracts from Artemisia capillaries (A. capillaries) and Camellia sinensis (C. sinensis) could be used as alternatives to antibiotic growth promoters in broiler feed. The experiment 1 was verified their chemical composition, extracts yields, total phenolic compounds concentration, antioxidant activity, antimicrobial activity, and chicken splenocytes proliferation through in vitro test. The extract yields of A. capillaries and C. sinensis were 26.5 and 16.8%, respectively. Total phenolic compounds concentrations of them expressed as gallic acid equivalent were 15.28 and 26.74 mg/mL, respectively. Electron donating abilities of them expressed as $SC_{50}$ showing 50% DPPH radical scavenging were 0.30 and 0.06 mg, respectively. Bacterial inhibitory rates of them against Escherichia coli, Staphylococcus aureus, and Salmonella Typhimurium were ranged from 42.1 to 52.3% and from 21.6 to 33.7%, respectively. And, these extracts increased proliferation of chicken splenocytes. Especially, A. capillaris was more excellent than Echinacea and Concanavalin A known as T-cell stimulator. The experiment 2 was investigated their effects on growth performance, relative organ weight, cecal microflora, blood biochemical parameters, and splenic cytokines mRNA expression in broiler chicks. Four hundred eighty 1-day-old male broiler chicks (Ross 308) were divided in to 4 treatment groups with 4 replicates of 30 birds in each group: NC (control, no antibiotics), PC (avilamycin, 10 ppm; salinomycin, 60 ppm), AC (A. capillaries, 100 ppm), and CS (C. sinensis, 100 ppm); treatments were administered through water supplementation. Final body weight was significantly higher in all treated groups than in NC (p<0.05). Cecal Salmonella numbers were significantly or somewhat decreased in all treated groups than in NC (p<0.05). The relative weights and lengths of the small intestine were more significantly decreased in the PC and AC groups than in the other groups. Cecal Salmonella numbers were significantly or somewhat decreased in all treated groups than in the NC group (p<0.05). The contents of total cholesterol, aspatate aminotransferase, and alanine aminotransferase in blood serum were more significantly decreased in all treated groups than in NC (p<0.05). In conclusion, these results suggested the possibility that these extracts could serve as alternatives for antibiotic growth promoters.

Studies on the Derivation of the Instantaneous Unit Hydrograph for Small Watersheds of Main River Systems in Korea (한국주요빙계의 소유역에 대한 순간단위권 유도에 관한 연구 (I))

  • 이순혁
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.19 no.1
    • /
    • pp.4296-4311
    • /
    • 1977
  • This study was conducted to derive an Instantaneous Unit Hydrograph for the accurate and reliable unitgraph which can be used to the estimation and control of flood for the development of agricultural water resources and rational design of hydraulic structures. Eight small watersheds were selected as studying basins from Han, Geum, Nakdong, Yeongsan and Inchon River systems which may be considered as a main river systems in Korea. The area of small watersheds are within the range of 85 to 470$\textrm{km}^2$. It is to derive an accurate Instantaneous Unit Hydrograph under the condition of having a short duration of heavy rain and uniform rainfall intensity with the basic and reliable data of rainfall records, pluviographs, records of river stages and of the main river systems mentioned above. Investigation was carried out for the relations between measurable unitgraph and watershed characteristics such as watershed area, A, river length L, and centroid distance of the watershed area, Lca. Especially, this study laid emphasis on the derivation and application of Instantaneous Unit Hydrograph (IUH) by applying Nash's conceptual model and by using an electronic computer. I U H by Nash's conceptual model and I U H by flood routing which can be applied to the ungaged small watersheds were derived and compared with each other to the observed unitgraph. 1 U H for each small watersheds can be solved by using an electronic computer. The results summarized for these studies are as follows; 1. Distribution of uniform rainfall intensity appears in the analysis for the temporal rainfall pattern of selected heavy rainfall event. 2. Mean value of recession constants, Kl, is 0.931 in all watersheds observed. 3. Time to peak discharge, Tp, occurs at the position of 0.02 Tb, base length of hlrdrograph with an indication of lower value than that in larger watersheds. 4. Peak discharge, Qp, in relation to the watershed area, A, and effective rainfall, R, is found to be {{{{ { Q}_{ p} = { 0.895} over { { A}^{0.145 } } }}}} AR having high significance of correlation coefficient, 0.927, between peak discharge, Qp, and effective rainfall, R. Design chart for the peak discharge (refer to Fig. 15) with watershed area and effective rainfall was established by the author. 5. The mean slopes of main streams within the range of 1.46 meters per kilometer to 13.6 meter per kilometer. These indicate higher slopes in the small watersheds than those in larger watersheds. Lengths of main streams are within the range of 9.4 kilometer to 41.75 kilometer, which can be regarded as a short distance. It is remarkable thing that the time of flood concentration was more rapid in the small watersheds than that in the other larger watersheds. 6. Length of main stream, L, in relation to the watershed area, A, is found to be L=2.044A0.48 having a high significance of correlation coefficient, 0.968. 7. Watershed lag, Lg, in hrs in relation to the watershed area, A, and length of main stream, L, was derived as Lg=3.228 A0.904 L-1.293 with a high significance. On the other hand, It was found that watershed lag, Lg, could also be expressed as {{{{Lg=0.247 { ( { LLca} over { SQRT { S} } )}^{ 0.604} }}}} in connection with the product of main stream length and the centroid length of the basin of the watershed area, LLca which could be expressed as a measure of the shape and the size of the watershed with the slopes except watershed area, A. But the latter showed a lower correlation than that of the former in the significance test. Therefore, it can be concluded that watershed lag, Lg, is more closely related with the such watersheds characteristics as watershed area and length of main stream in the small watersheds. Empirical formula for the peak discharge per unit area, qp, ㎥/sec/$\textrm{km}^2$, was derived as qp=10-0.389-0.0424Lg with a high significance, r=0.91. This indicates that the peak discharge per unit area of the unitgraph is in inverse proportion to the watershed lag time. 8. The base length of the unitgraph, Tb, in connection with the watershed lag, Lg, was extra.essed as {{{{ { T}_{ b} =1.14+0.564( { Lg} over {24 } )}}}} which has defined with a high significance. 9. For the derivation of IUH by applying linear conceptual model, the storage constant, K, with the length of main stream, L, and slopes, S, was adopted as {{{{K=0.1197( {L } over { SQRT {S } } )}}}} with a highly significant correlation coefficient, 0.90. Gamma function argument, N, derived with such watershed characteristics as watershed area, A, river length, L, centroid distance of the basin of the watershed area, Lca, and slopes, S, was found to be N=49.2 A1.481L-2.202 Lca-1.297 S-0.112 with a high significance having the F value, 4.83, through analysis of variance. 10. According to the linear conceptual model, Formular established in relation to the time distribution, Peak discharge and time to peak discharge for instantaneous Unit Hydrograph when unit effective rainfall of unitgraph and dimension of watershed area are applied as 10mm, and $\textrm{km}^2$ respectively are as follows; Time distribution of IUH {{{{u(0, t)= { 2.78A} over {K GAMMA (N) } { e}^{-t/k } { (t.K)}^{N-1 } }}}} (㎥/sec) Peak discharge of IUH {{{{ {u(0, t) }_{max } = { 2.78A} over {K GAMMA (N) } { e}^{-(N-1) } { (N-1)}^{N-1 } }}}} (㎥/sec) Time to peak discharge of IUH tp=(N-1)K (hrs) 11. Through mathematical analysis in the recession curve of Hydrograph, It was confirmed that empirical formula of Gamma function argument, N, had connection with recession constant, Kl, peak discharge, QP, and time to peak discharge, tp, as {{{{{ K'} over { { t}_{ p} } = { 1} over {N-1 } - { ln { t} over { { t}_{p } } } over {ln { Q} over { { Q}_{p } } } }}}} where {{{{K'= { 1} over { { lnK}_{1 } } }}}} 12. Linking the two, empirical formulars for storage constant, K, and Gamma function argument, N, into closer relations with each other, derivation of unit hydrograph for the ungaged small watersheds can be established by having formulars for the time distribution and peak discharge of IUH as follows. Time distribution of IUH u(0, t)=23.2 A L-1S1/2 F(N, K, t) (㎥/sec) where {{{{F(N, K, t)= { { e}^{-t/k } { (t/K)}^{N-1 } } over { GAMMA (N) } }}}} Peak discharge of IUH) u(0, t)max=23.2 A L-1S1/2 F(N) (㎥/sec) where {{{{F(N)= { { e}^{-(N-1) } { (N-1)}^{N-1 } } over { GAMMA (N) } }}}} 13. The base length of the Time-Area Diagram for the IUH was given by {{{{C=0.778 { ( { LLca} over { SQRT { S} } )}^{0.423 } }}}} with correlation coefficient, 0.85, which has an indication of the relations to the length of main stream, L, centroid distance of the basin of the watershed area, Lca, and slopes, S. 14. Relative errors in the peak discharge of the IUH by using linear conceptual model and IUH by routing showed to be 2.5 and 16.9 percent respectively to the peak of observed unitgraph. Therefore, it confirmed that the accuracy of IUH using linear conceptual model was approaching more closely to the observed unitgraph than that of the flood routing in the small watersheds.

  • PDF

Temporal Variations of Ore Mineralogy and Sulfur Isotope Data from the Boguk Cobalt Mine, Korea: Implication for Genesis and Geochemistry of Co-bearing Hydrothermal System (보국 코발트 광상의 산출 광물종 및 황동위원소 조성의 시간적 변화: 함코발트 열수계의 성인과 지화학적 특성 고찰)

  • Yun, Seong-Taek;Youm, Seung-Jun
    • Economic and Environmental Geology
    • /
    • v.30 no.4
    • /
    • pp.289-301
    • /
    • 1997
  • The Boguk cobalt mine is located within the Cretaceous Gyeongsang Sedimentary Basin. Major ore minerals including cobalt-bearing minerals (loellingite, cobaltite, and glaucodot) and Co-bearing arsenopyrite occur together with base-metal sulfides (pyrrhotite, chalcopyrite, pyrite, sphalerite, etc.) and minor amounts of oxides (magnetite and hematite) within fracture-filling $quartz{\pm}actinolite{\pm}carbonate$ veins. These veins are developed within an epicrustal micrographic granite stock which intrudes the Konchonri Formation (mainly of shale). Radiometric date of the granite (85.98 Ma) indicates a Late Cretaceous age for granite emplacement and associated cobalt mineralization. The vein mineralogy is relatively complex and changes with time: cobalt-bearing minerals with actinolite, carbonates, and quartz gangues (stages I and II) ${\rightarrow}$ base-metal sulfides, gold, and Fe oxides with quartz gangues (stage III) ${\rightarrow}$ barren carbonates (stages IV and V). The common occurrence of high-temperature minerals (cobalt-bearing minerals, molybdenite and actinolite) with low-temperature minerals (base-metal sulfides, gold and carbonates) in veins indicates a xenothermal condition of the hydrothermal mineralization. High enrichment of Co in the granite (avg. 50.90 ppm) indicates the magmatic hydrothermal derivation of cobalt from this cooling granite stock, whereas higher amounts of Cu and Zn in the Konchonri Formation shale suggest their derivations largely from shale. The decrease in temperature of hydrothermal fluids with a concomitant increase in fugacity of oxygen with time (for cobalt deposition in stages I and II, $T=560^{\circ}C-390^{\circ}C$ and log $fO_2=$ >-32.7 to -30.7 atm at $350^{\circ}C$; for base-metal sulfide deposition in stage III, $T=380^{\circ}-345^{\circ}C$ and log $fO_2={\geq}-30.7$ atm at $350^{\circ}C$) indicates a transition of the hydrothermal system from a magmatic-water domination toward a less-evolved meteoric-water domination. Sulfur isotope data of stage II sulfide minerals evidence that early, Co-bearing hydrothermal fluids derived originally from an igneous source with a ${\delta}^{34}S_{{\Sigma}S}$ value near 3 to 5‰. The remarkable increase in ${\delta}^{34}S_{H2S}$ values of hydrothermal fluids with time from cobalt deposition in stage II (3-5‰) to base-metal sulfide deposition in stage III (up to about 20‰) also indicates the change of the hydrothermal system toward the meteoric water domination, which resulted in the leaching-out and concentration of isotopically heavier sulfur (sedimentary sulfates), base metals (Cu, Zn, etc.) and gold from surrounding sedimentary rocks during the huge, meteoric water circulation. We suggest that without the formation of the later, meteoric water circulation extensively through surrounding sedimentary rocks the Boguk cobalt deposits would be simple veins only with actinolite + quartz + cobalt-bearing minerals. Furthermore, the formation of the meteoric water circulation after the culmination of a magmatic hydrothermal system resulted in the common occurrence of high-temperature minerals with later, lower-temperature minerals, resulting in a xenothermal feature of the mineralization.

  • PDF

Effects of Fire Retardant Treatment on Mechanical Properties and Fire Retardancy of Particleboard and Complyboard (내화처리(耐火處理)가 파아티클보오드와 콤플라이보오드의 기계적성질(機械的性質) 및 내화도(耐火度)에 미치는 영향(影響))

  • Kwon, Jin-Heon;Lee, Phll-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.3-57
    • /
    • 1985
  • This research was conducted to examine the feasibility of developing fire retardant particleboard and complyboard. Particleboard were manufactured using meranti particle(Shorea spp.)made with Pallmann chipper, and complyboard meranti particle and apitong veneer (Dipterocarpus spp.). Particles were passed through 4mm (6 mesh) and retained on 1mm (25 mesh). Urea formaldehyde resin was added 10 percent on ovendry weight of particle. Face veneer for complyboard was 0.9, 1.6 and 2.3mm in thickness and spread with 36 g/(30.48 cm)$^2$ glue on one side. Veneers were soaked with 10 percent solution of five fire retardant chemicals (diammonium phosphate, ammonium sulfate, monoammonium phosphate, Pyresote and Minalith), and particles with 5, 10, 15 and 20 percent solution of five chemicals. Particleboard and complyboard were evaluated on physical and mechanical properties, and fire retardancy. The results obtained were summarized as follows. 1. Among five fire retardant chemicals treated to particleboard and complyboard, the retention of ammonium sulfate in 5 percent solution showed the lowest as 1.39 kg/(30.48 cm)$^3$ exceeding the minimum retention of 1.125 kg/(30.48 cm)$^3$ recommended by Forest Products Laboratory and Koch. 2. Particleboard and complyboard treated with diammonium phosphate showed higher modulus of rupture (MOR), modulus of elasticity (MOE), internal bond strength and screw holding power than those with the other chemicals. 3. MOR and MOE of complyboard treated with fire retardant chemicals were greater than those of fire retardant particleboard. 4. Thickness swelling of fire retardant complyboard was lower than that of fire retardant particleboard. 5. The moisture content of the boards treated with Pyresote and Minalith increased and with monoammonium phosphate reduced. 6. Fire retardant particleboard showed no ignition, and fire retardant complyboard started ignition, but time required to ignite was prolonged comparing the controlboard. Complyboard with only shell veneer treated showed ignition and lingering flame, but lingering flame time was shorter than controlboard. Complyboard with treated both core and veneer showed ignition but not lingering flame. 7. Flame length, carbonized area and weight loss were smaller than controlboard but had no significant difference among chemicals treated. 8. Temperature of unexposed surface of fire retardant particleboard was lowered with the increasing concentration of five chemicals. 9. Temperature of unexposed surface of fire retardant particleboard was lowered with the highest in Pyresote and the lowest in Minalith. 10. Temperature of unexposed surface of fire retardant complyboard was lower than that of controlboard.

  • PDF