• Title/Summary/Keyword: High-volume

Search Result 6,458, Processing Time 0.036 seconds

Esophageal tolerance to high-dose stereotactic radiosurgery

  • Lee, Bo Mi;Chang, Sei Kyung;Ko, Seung Young;Yoo, Seung Hoon;Shin, Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.31 no.4
    • /
    • pp.234-238
    • /
    • 2013
  • Purpose: Esophageal tolerance is needed to guide the safe administration of stereotactic radiosurgery (SRS). We evaluated comprehensive dose-volume parameters of acute esophageal toxicity in patients with spinal metastasis treated with SRS. Materials and Methods: From May 2008 to May 2011, 30 cases in 27 patients with spinal metastasis received single fraction SRS to targets neighboring esophagus. Endpoints evaluated include length (mm), volume (mL), maximal dose (Gy), and series of dose-volume thresholds from the dose-volume histogram (volume of the organ treated beyond a threshold dose). Results: The median time from the start of irradiation to development of esophageal toxicity was 2 weeks (range, 1 to 12 weeks). Six events of grade 1 esophageal toxicity occurred. No grade 2 or higher events were observed. $V_{15}$ of external surface of esophagus was found to predict acute esophageal toxicity revealed by multivariate analysis (odds radio = 1.272, p = 0.047). Conclusion: In patients with spinal metastasis who received SRS for palliation of symptoms, the threshold dose-volume parameter associated with acute esophageal toxicity was found to be $V_{15}$ of external surface of esophagus. Restrict $V_{15}$ to external surface of esophagus as low as possible might be safe and feasible in radiosurgery.

Spatial Data Structure for Efficient Representation of Very Large Sparse Volume Data for 3D Reconstruction (3차원 복원을 위한 대용량 희소 볼륨 데이터의 효율적인 저장을 위한 공간자료구조)

  • An, Jae Pung;Shin, Seungmi;Seo, Woong;Ihm, Insung
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.3
    • /
    • pp.19-29
    • /
    • 2017
  • When a fixed-sized memory allocation method is used for sparse volume data, a considerable memory space is in general wasted, which becomes more serious for a large volume of high resolution. In this paper, in order to reduce such unnecessary memory consumption, we propose a volume representation method to store mostly voxels that represent valid information rather than all voxels in a fixed volume space. Then our method is compared with the conventional static memory allocation method, an octree-based representation, and a voxel hashing method in terms of memory usage and computation speed. In particular, we compare the proposed method and the voxel hashing method with respect to implementation of the GPU-based Marching Cubes algorithm.

Effect of Rice Protein on the Network Structure of Jeung-Pyun (증편 구조에 미치는 쌀 단백질의 영향)

  • 이해은;이아영;박주연;우경자;한영숙
    • Korean journal of food and cookery science
    • /
    • v.20 no.4
    • /
    • pp.396-402
    • /
    • 2004
  • The aim of this study was to examine the effect of rice protein on the network structure of the Jeung-Pyun. The major component of Jeung-Pyun rice protein was extracted, the change of rice protein during the Jeung-Pyun fermentation was assessed, and the effect on the viscosity and volume of adding protease to Jeung-Pyun was investigated. In addition, the result of adding protein to rice starch on the viscosity and volume of Jeung-Pyun was that the rice protein mediated the volume and expansion ability. The results were as follows. In rice and dough of Jeung-Pyun, the SDS soluble protein content was higher than that of wheat flour and no change was detected in the amount of extracted protein with the fermentation time. However, in the FPLC pattern, low molecular weight peaks were decreased with the fermentation time, which indicates the increase in the ratio of high molecular weight substances. In contrast, the addition of protease substantially decreased, the viscosity and volume of Jeung-Pyun, whereas the viscosity and volume were increased by adding protein to rice starch in order to reconstitute Jeung-Pyun. This suggested that rice protein in Jeung-Pyun had a mediating effect on both the volume and the formation of the texture.

Research on the characteristics of noise exposure on worker wearing acoustic devices (음향도구 착용 근로자의 소음노출 실태에 관한 연구)

  • Kim, Kab-Bae;Yoo, Kye-Mook;Lee, In-Seop;Chung, Kwang-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.808-813
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset Noise exposure measurements of 17 operators were performed in 7 call centers and Head and Torso Simulator method in compliance with the ISO Standard 11904-2 was used for the measurement of noise transmitted from the headset Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of Pearson Correlation Analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

  • PDF

Partial Breast Reconstruction Using Various Oncoplastic Techniques for Centrally Located Breast Cancer

  • Park, Hyo Chun;Kim, Hong Yeul;Kim, Min Chul;Lee, Jeong Woo;Chung, Ho Yun;Cho, Byung Chae;Park, Ho Yong;Yang, Jung Dug
    • Archives of Plastic Surgery
    • /
    • v.41 no.5
    • /
    • pp.520-528
    • /
    • 2014
  • Background As the breast cancer incidence has increased, breast-conserving surgery has replaced total mastectomy as the predominant procedure. However, centrally located breast cancers pose significant challenges to successful breast-conserving surgeries. Therefore, we performed partial mastectomy and oncoplastic procedures on centrally located breast cancer as a means of partial breast reconstruction. The authors examined and evaluated the functional and aesthetic usefulness of this reconstruction method. Methods From January 2007 to June 2011, 35 patients with centrally located breast cancers who underwent various oncoplastic procedures based on the breast size and resection volume. The oncoplastic procedures performed included volume displacement surgical techniques such as purse-string suture, linear suture, and reduction mammaplasty. Other oncoplastic procedures included volume replacement procedures with an adipofascial, thoracoepigastric, intercostal artery perforator, thoracodorsal artery perforator, or latissimus dorsi flap. Results Mean patient age was 49 years, and mean follow-up period was 11 months. In cases of small to moderate-sized breasts and resection volumes <50 g, volume displacement procedures were performed. In cases of resection volumes >50 g, volume replacement procedures were performed. In cases of larger breasts and smaller resection volumes, glandular reshaping was performed. Finally, in cases of larger breasts and larger resection volumes, reduction mammaplasty was performed. This reconstruction method also elicits a high patient satisfaction rate with no significant complications. Conclusions In centrally located breast cancer, oncoplastic surgery considering breast size and resection volume is safe and provides appropriate aesthetic outcomes. Therefore, our method is advisable for breast cancer patients who elect to conserve their breasts and retain a natural breast shape.

A Mapping Method for a Logical Volume Manager in SAN Environment (SAN 논리볼륨 관리자를 위한 매핑 기법)

  • 남상수;송석일;유재수;김창수;김명준
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.6
    • /
    • pp.718-731
    • /
    • 2003
  • SAN(Storage Area Network) was developed in response to the requirements of high availability of data, scalable growth, and system performance. In order to use the SAN more efficiently, most of the SAN operating software supports storage virtualization concepts that allow users to view physical storage devices of the SAN as a large volume. A logical volume manager plays a key role in storage virtualization. It realizes the storage virtualization by mapping logical addresses to physical addresses. In this paper, we design and implement an efficient and flexible mapping method for the logical volume manager. Additionally we also design and implement a free space management method for flexible mapping. Our mapping method supports a snapshot that preserves a volume image at certain time and on-line reorganization to allow users to add or remove storage devices to and from the SAN even while the system is running. To justify our mapping method, we compare it with the mapping method of the GFS (Global File System) through various experiments.

Batter and Product Characteristics of Sponge Cake Containing Sugar Alcohols (당알코올을 첨가한 스펀지 케이크 반죽 및 제품 특성)

  • Chung, Woul-Gye;Lee, Jeong-Hoon
    • Culinary science and hospitality research
    • /
    • v.16 no.4
    • /
    • pp.305-311
    • /
    • 2010
  • This study was carried out to investigate the availability of sorbitol and maltitol as alternative sweeteners for replacement of sucrose in sponge cake. Physical characteristics of batter such as specific gravity, pH of cake batter and volume, texture of sponge cake were analyzed lst specific gravities of batters contained 10~40% of sorbitol and maltitol were lower than that of the sucrose. 2nd specific gravity of batters showed the same results as the lst specific gravity. pH of the cake batters contained sorbitol and maltitol revealed high value compared to the control. As the amount of replacement increased, pH value showed higher. In terms of cake volume, as the amounts of sorbitol and maltitol were increased, the volume was larger than that of the control. Up to 20% of replacement, the cake contained sorbitol showed higher volume than that containing maltitol, but the cake contained maltitol showed higher volume in above 30% In terms of texture of sponge cake, the control showed the highest in hardness, as the amounts of sorbitol and maltitol were increased, hardness value has lowered compared to the control on the same storage day. In this study, addition of sorbitol and maltitol to sponge cake showed good results.

  • PDF

Research on the Characteristics and Measures of Noise Exposure on Worker Wearing Acoustic Devices (음향도구 착용 근로자의 소음노출 실태에 관한 연구)

  • Kim, Kab-Bae;Yoo, Kye-Mook;Lee, In-Seop;Chung, Kwang-Jae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.7
    • /
    • pp.615-621
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset. Noise exposure measurements of 17 operators were performed in 7 call centers and head and Torso simulator method in compliance with the ISO standard 11904-2 was used for the measurement of noise transmitted from the headset. Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of pearson correlation analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

Complication After Gastrectomy for Gastric Cancer According to Hospital Volume: Based on Korean Gastric Cancer Association-Led Nationwide Survey Data

  • Sang-Ho Jeong;Moon-Won Yoo ;Miyeong Park ;Kyung Won Seo ;Jae-Seok Min;Information Committee of the Korean Gastric Cancer Association
    • Journal of Gastric Cancer
    • /
    • v.23 no.3
    • /
    • pp.462-475
    • /
    • 2023
  • Purpose: This study aimed to analyze the incidence and risk factors of complications following gastric cancer surgery in Korea and to compare the correlation between hospital complications based on the annual number of gastrectomies performed. Materials and Methods: A retrospective analysis was conducted using data from 12,244 patients from 64 Korean institutions. Complications were classified using the Clavien-Dindo classification (CDC). Univariate and multivariate analyses were performed to identify the risk factors for severe complications. Results: Postoperative complications occurred in 14% of the patients, severe complications (CDC IIIa or higher) in 4.9%, and postoperative death in 0.2%. The study found that age, stage, American Society of Anesthesiologists (ASA) score, Eastern Cooperative Oncology Group (ECOG) score, hospital stay, approach methods, and extent of gastric resection showed statistically significant differences depending on hospital volumes (P<0.05). In the univariate analysis, patient age, comorbidity, ASA score, ECOG score, approach methods, extent of gastric resection, tumor-node-metastasis (TNM) stage, and hospital volume were significant risk factors for severe complications. However, only age, sex, ASA score, ECOG score, extent of gastric resection, and TNM stage were statistically significant in the multivariate analysis (P<0.05). Hospital volume was not a significant risk factor in the multivariate analysis (P=0.152). Conclusions: Hospital volume was not a significant risk factor for complications after gastric cancer surgery. The differences in the frequencies of complications based on hospital volumes may be attributed to larger hospitals treating patients with younger age, lower ASA scores, better general conditions, and earlier TNM stages.

Evaluation of the Accuracy of Distance Measurements on 3D Volume-rendered Image of Human Skull Using Multi-detector CT: Effects of Acquisition Section Thickness and Reconstruction Section Thickness

  • Haijo Jung;Kim, Hee-Joung;Lee, Sang-Ho;Kim, Dong-Wook;Soonil Hong;Kim, Dong-Hyeon;Son, Hye-Kyung;Wonsuk Kang;Kim, Kee-Deog
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.457-460
    • /
    • 2002
  • The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.

  • PDF