• Title/Summary/Keyword: High-volume

Search Result 6,458, Processing Time 0.031 seconds

Estimation of Representative Mechanical Property of Porous Electrode for Secondary Batteries with Homogenization Method (균질화 기법을 이용하여 기공이 있는 이차전지 극판의 대표 기계 물성 도출을 위한 연구)

  • Pyo, Changmin;Kim, Jaewoong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.9
    • /
    • pp.85-91
    • /
    • 2022
  • The demand for electric vehicles has increased because of environmental regulations. The lithium-ion battery, the most widely used type of battery in electric vehicles, is composed of a cathode, an anode, and an electrolyte. It is manufactured according to the pole plate, assembly, and formation processes. To improve battery performance and increase manufacturing efficiency, the manufacturing process must be optimized. To do so, simulation can be used to reduce wasted resources and time, and a finite-element method can be utilized. For high simulation quality, it is essential to reflect the material properties of the electrode by considering the pores. However, the material properties of electrodes are difficult to derive through measurement. In this study, the representative volume element method, which is a homogenization method, was applied to estimate the representative material properties of the electrode considering the pores. The representative volume element method assumes that the strain energy before and after the conversion into a representative volume is conserved. The method can be converted into one representative property, even when nonhomogeneous materials are mixed in a unit volume. In this study, the material properties of the electrode considering the pores were derived. The results should be helpful in optimizing the electrode manufacturing process and related element technologies.

A Study on the Growth of Air Cargo Volume and the Development Plan for Regional Airport Focusing on Cheonng-Ju Int'l Airport (항공화물 활성화를 위한 정책분석과 지방공항 발전방안 연구: 청주국제공항을 중심으로)

  • Won-Tae Park;Yeon-Young Sung;Sung-Sik Park
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.32 no.2
    • /
    • pp.112-123
    • /
    • 2024
  • Responding to rapid changes of global supply chain and fast increasing air cargo volume and demand for e-commerce market, this paper researched the development plans for regional airport specially focused on air cargo logostics through policy research. According to this research, political implications and development plans for Cheong Ju airport (CJJ) to become a part of global supply chain, a regional air cargo hub. Firstly, it is necessary to increase the length of the existing runway from 2,744m to 3,200m or to develop 3rd runway only for a civil aircraft use. Secondly, it is inevitable to develop new air cargo terminal to handle and export such high value-added products as semi-conductor or rechargeable battery through airport. In addition, facing re-shoring trends among global supply chain, CJJ can increase its air cargo volume and also provide feeder service to Incheon airport, inducing global distribution center near airport site.

Optimization and Mathematical Modeling of the Transtubular Bioreactor for the Production of Monoclonal Antibodies from a Hybridoma Cell Line

  • Halberstadt, Craig R.;Palsson, Bernhanrd O.;Midgley, A.Rees;Curl, Rane L.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.3
    • /
    • pp.163-170
    • /
    • 2002
  • This report describes the use of a transtubular bioreactor to study the relative effects of diffusion versus perfusion of medium on antibody production by a hybridoma cell line. The study was performed with a high-density cell culture maintained in a serum-free, low-protein medium for 77 days. It was determined that the reactor possessed a macro-mixing pattern residence time distribution similar to a continuous stirred tank reactor (CSTR), However, due to the arrangement of the medium lines in the reactor, the flow patterns for nutrient distribution consist of largely independent medium path lengths ranging from short to long. When operated with cyclic, reversing, transtubular medium flow, some regions of the reactor (with short residence times) are more accessible to medium than others (with long residence times). From this standpoint, the reactor can be divided into three regions: a captive volume, which consists of medium primarily delivered via diffusion; a lapped volume, which provides nutrients through unilateral convection; and a swept volume, which operates through bilateral convection. The relative sizes of these three volumes were modified experimentally by changing the period over which the direction of medium flow was reversed from 15 min (larger captive volume) to 9 h (larger swept volume). The results suggest that antibody concentration increases as the size of the diffusion-limited (captive) volume is increased to a maximum at around 30 min with a sharp decrease thereafter. As reflected by changes in measured consumption of glucose and production of lactate, no significant difference in cellular metabolism occurred as the reactor was moved between these different states. These results indicate that the mode of operation of the transtubular bioreactor may influence antibody productivity under serum-free, low-protein conditions with minimal effects on cellular metabolism.

Dosimetric Evaluation of 3-D Conformal and Intensity-modulated Radiotherapy for Breast Cancer after Conservative Surgery

  • Mansouri, Safae;Naim, Asmaa;Glaria, Luis;Marsiglia, Hugo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4727-4732
    • /
    • 2014
  • Background: Breast cancers are becoming more frequently diagnosed at early stages with improved long term outcomes. Late normal tissue complications induced by radiotherapy must be avoided with new breast radiotherapy techniques being developed. The aim of the study was to compare dosimetric parameters of planning target volume (PTV) and organs at risk between conformal (CRT) and intensity-modulated radiation therapy (IMRT) after breast-conserving surgery. Materials and Methods: A total of 20 patients with early stage left breast cancer received adjuvant radiotherapy after conservative surgery, 10 by 3D-CRT and 10 by IMRT, with a dose of 50 Gy in 25 sessions. Plans were compared according to dose-volume histogram analyses in terms of PTV homogeneity and conformity indices as well as organs at risk dose and volume parameters. Results: The HI and CI of PTV showed no difference between 3D-CRT and IMRT, V95 gave 9.8% coverage for 3D-CRT versus 99% for IMRT, V107 volumes were recorded 11% and 1.3%, respectively. Tangential beam IMRT increased volume of ipsilateral lung V5 average of 90%, ipsilateral V20 lung volume was 13%, 19% with IMRT and 3D-CRT respectively. Patients treated with IMRT, heart volume encompassed by 60% isodose (30 Gy) reduced by average 42% (4% versus 7% with 3D-CRT), mean heart dose by average 35% (495cGy versus 1400 cGy with 3D-CRT). In IMRT minimal heart dose average is 356 cGy versus 90cGy in 3D-CRT. Conclusions: IMRT reduces irradiated volumes of heart and ipsilateral lung in high-dose areas but increases irradiated volumes in low-dose areas in breast cancer patients treated on the left side.

An Efficient Anisotropic Volume Rendering using an Intensity Interpolation and Adaptive Intermediate Voxel Insertion Method (광도 보간과 적응형 중간복셀 삽입법을 이용한 효율적인 비균등 볼륨 렌더링)

  • 김태영;신병석
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.30 no.11
    • /
    • pp.655-662
    • /
    • 2003
  • In some volume visualization fields such as medical imaging, anisotropic volume data are more common than isotropic ones. In this paper, we propose an efficient rendering method for anisotropic volume data, which directly computes the intensity of intermediate samples by interpolating the intensity of two corresponding voxels on consecutive slices. Unlike density interpolation method, it does not require a preprocessing step for generating intermediate slices or additional memory for storing them. Additionally, we propose an adaptive intermediate voxel insertion method that avoids overblurring on object surfaces. This may occur when we render high frequency areas using the intensity interpolation method. Using these methods, we can improve the rendering speed without sacrificing image quality.

Long-term Outcomes of Gamma Knife Stereotactic Radiosurgery of Vestibular Schwannomas

  • Kim, Kang-Min;Park, Chul-Kee;Chung, Hyun-Tai;Paek, Sun-Ha;Jung, Hee-Won;Kim, Dong-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.286-292
    • /
    • 2007
  • Objective : Gamma Knife Stereotactic Radiosurgery (GK SRS) has become an important treatment modality for vestibular schwannomas. We evaluated the tumor control rate, patterns of tumor volume change and preservation of hearing following low-dose radiation for vestibular schwannomas in a homogeneous cohort group in which the mean marginal dose was 12 Gy. Methods : A total of 59 patients were enrolled in this study. All enrolled patients were followed-up for at least 5 years and the radiation dose was 11-13 Gy. Regular MRI, audiometry and clinical evaluations were done and tumor volumes were obtained from MRI using the OSIRIS program. Results : The tumor control rate was 97%. We were able to classify the patterns of change in tumor volume into three categories. Transient increases in tumor volume were detected in 29% of the patients and the maximum transient increase in tumor volume was identified at 6 to 30 months after GK SRS. The transient increases in tumor volume ranged from 121% to 188%. Hearing was preserved in 4 of the 12 patients who had serviceable hearing prior to treatment. There were no other complications associated with GK SRS. Conclusion : Low-dose GK SRS was an effective and safe mode of treatment for vestibular schwannomas in comparison to the previously used high-dose GK SRS. Transient increases in tumor volume can be identified during the follow-up period after low-dose GK SRS for vestibular schwannomas. Physicians should be aware that these increases are not always indicative of treatment failure and that close observation is required following treatments. Unfortunately, a satisfactory hearing preservation rate was not achieved by reducing the radiation dose. It is thought that hearing preservation is a more sophisticated problem and further research is required.